05000287/LER-1978-010-03, /03L-0:on 780322,no Flow Found Through B LPIS Cooler During Performance Test.Caused by Broken Valve Position Indicator.Valve Opened & Indicator Repaired

From kanterella
(Redirected from ML19340A136)
Jump to navigation Jump to search
/03L-0:on 780322,no Flow Found Through B LPIS Cooler During Performance Test.Caused by Broken Valve Position Indicator.Valve Opened & Indicator Repaired
ML19340A136
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 04/21/1978
From: Ken Wilson
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19340A133 List:
References
LER-78-010-03L, LER-78-10-3L, NUDOCS 8001100601
Download: ML19340A136 (2)


LER-1978-010, /03L-0:on 780322,no Flow Found Through B LPIS Cooler During Performance Test.Caused by Broken Valve Position Indicator.Valve Opened & Indicator Repaired
Event date:
Report date:
2871978010R03 - NRC Website

text

.

' h' a.u: ponu ans E

u. s.tucLsAn cucut.Arony commission m

LICENSEE EVENT REPORT EXHlBIT A CONTROL ELoCC l l

l l

l l jh (PLEASE PRINT oR TYPt ALL REQutREO INFoAMAnoM ITTil I s I C IN is l e 13 l@lo 10 l -l o ro 10 I o l 01 -101 ol@l 4 I i i lit I i l@l., c.I,,.l @

.uca.... coo.

i.

i.

uc.. u-e.a 2..

=

uco. rv,..

con'T lotiI 7$ lL @lofs 10loIolg IRl7 @ln I,b l 9f 7 I g @l0 14 ! ? l1 I7 l8 l@

8 00 65 occzg7NumetR es es tvt47 0 ATE 7.

is

  • EPCAT OArg se svtNT otscairnca Ano paosAsts cousscusNess @

lo t 2l l Durine a performance test on the LPSW system, it was discovered that no l

l"3TTl I flow was indicated through the B LPI Cooler.

Investigation revealed that I

f'o"TT1 I valve 3LPSW-78 was closed, preventing the flow. This valve is normally I

eI open. The valve was returned to its open condition. The inoperability of t o is 11 LPI Cooler B did not prevent the system f rom performing its de:ay heat io ;i; l removal requirements; if needed, because only one cooler is required and io,eil Cooler A was available.

l SCIE" TSE stfe$e l W I A l@ [3_j@ l B l@ II I N ! S T l R l U l@ ue."o'c's[.I j @ l_zj @

su'NUr ceumaswT:coe s

loisi I

r 8

to 11 12 12 is I.

20 StoutNTIAL

% A ttact 4tPCMT AEVi$3ose.

EvimT vtAn maronf No.

cCct ft t No,

@,"q,g pino1 718 I l-1 I o f 1101 1A lo'J.J.

IL I L--J U

f,gr 2i

2 a

2.

a 21

s 2a ai 22 EN "S!,!

o!!,' der

. =sTr$"

cuas@10l 'U'f"r"rE' da'E.

'"s'u",'87' uf=*u",'*E".Ian lE l@l B l@

l,z!@

lZ j@

l ofI !o u

s a

as

[],.j @

(Y_,,j@

lL l@

l All l8 l 0l@

i ar

.a

\\

cAuss cesemipncu Axoccanaenvs Acncus @

iiioi l The cause of the valve closure was the fact that the valve opens " backwards",

i,,,jl (clockwise-to-open) and its position indicator was broken.

':he valve was l

gi noticed to be partially open earlier the same day during a valve lineup gl check and when the operator " opened" the valve he, in fact, closed it.

,,,.i; Corrective actions included opening the valve and repairing the indicator.

r ae A

% 8CY

.TMEASTATV3 0,5Co MY li_L5 l l.f j@ l 11 o'.4lol@l NA l' l B I@l During performance test I

043coVERY oE3cMirTICN e g.ny,y g,m u

u a

l i I s I LZJ @o,.. m.Lz.JOl_ou T o,.,,,,, @ l to.An

....,,A., @

..< m.

NA l

NA l

' ' m e,,,'.'s x,ess..

a li t r i l o f o f ol@LZ.J@(..,c...,o, @NA

.u....

l me.. A',uuL o.sc.,no @

=

vo...

fTo1IoI010l@l NA l

n b". * "l'",'#o',', '" @

L. aj@l NA l

1 L 2 La.J d. sus @Se"semrnoa@

,s Nac use oNi.y l

NA l

[!!IIIlttlltl i.

.o NAME CF PREPAAER K. R. Wilson

,,cy,;

tynn 27, g197 8 0 01100 b@

3

' DUKE POWER COMPANY OCONEE UNIT 3-Report Number: 'RO-287/78-10 Report Date: April 21, 1978.

Occurrence Date:

March 22, 1978 j-Facility: - Oconee Unit 3, Seneca, South Carolina Identification of Occurrence:

Low Pressure Injection System Cooler B Inoperable Conditions Prior to Occurrence:

100% Full Power Description of Occurrence:

i

- At approximately 0630 on March 22, 1978 during the performance of OP/3/A/1104/10, Low Pressure Service Water (LPSW) System Valve Lineup Check, it was noted that valve 3LPSW-78 was neither fully open or closed. The utility operator was

' directed to open the valve; but, when he attempted to do so, he inadvertently closed the valve.

The valve operates in the unusual clockwise-to-open configuration..The mechanical position indicator was broken so that his error was not immediately detectable. At approximately 0830 during the performance of PT/3/A /025/1, LPSW Performance Test, it-was discovered that no flow could be established through the B cooler. The subsequent investigation indicated the' erroneous valve closure and the valve was opened by 0845.

Apparent Caus' of Occurrence:

l

. The cause.of the occurrence was the broken position indicator coupled with the clockwise-to-coen characteristic of the handwheel.

Analysis of Occurrents:

The closure of valve LPSW-78 removed LP Cooler B'from service. One cooler

^

is necessary for decay heat removal (FSAR Section 6.1.2.7).

Since LP Cooler A was available, the occurrence caused no loss-of-function to the system.

Public health and safety were not endangered.

Corrective Action

i i

The valve was' opened to return LP Cooler-B to service. All clockwise-to-open'valvesfat-the Oconee Station will be identified and tagged and-any.

broken position indicators:will be repaired.