Clarifies Testing Commitment Made Re Insp Rept 50-244/97-201 & Notifies That Appropriate Alternative to Clarified Testing Commitment Has Been Performed During Current Refueling Outage
ML17264B082
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/03/1997
From: MECREDY R C
ROCHESTER GAS & ELECTRIC CORP.
To: VISSING G S
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
50-244-97-201, GL-89-04, GL-89-4, NUDOCS 9711120009
Download: ML17264B082 (5)


See also: IR 05000244/1997201

Text

CATEGORY1REGULATORYINFORMATIONDISTRIBUTIONSYSTEM(RIDS)ACCESSIONNBR:9711120009DOC.DATE:97/11/03NOTARIZED:NODOCKETFACZL:50-244RobertEmmetGinnaNuclearPlant,Unit1,RochesterG05000244AUTH.NAMEAUTHORAFFILIATION'MECREpY,R.C.RochesterGasaElectricCorp.RECIP.NAMERECIPIENTAFFILIATIONVISSING,.G.S.SUBJECT:Clarifiestestingcommitmentmadereinsprept50-244/97-201&notifiesthatappropriatealternativetoclarifiedtestingcommitmenthasbeenperformedduringcurrentrefuelingoutae.gDISTRIBUTION,CODE:IE01DCOPIESRECEIVED:LTRENCLSIZE:TITLE:General(50Dkt)-ZnspRept/NoticeofViolationResponseCNOTES:LicenseExpdateinaccordancewith10CFR2,2.109(9/19/72).05000244EG,RECIPIENTIDCODE/NAMEPD1-1PDINTERNAL:AEOD/SPD/RAB.DEDRONRR/DISP/PIPBNRR/DRPM/PECBNUDOCS-ABSTRACTOGC/HDS3XTERNAL:LZTCOBRYCE,JHNRCPDRCOPIESLTTRENCL1'11111RECIPIENTIDCODE/NAMEVISSING,G.AEODLECENTECH/HHFBNRR/DRPM/PERBOEDIRRGN1FILE01NOACNUDOCSFULLTEXTCOPIESLTTRENCLD0NNOTETOALL"RIDS"RECIPIENTS:PLEASEHELPUSTOREDUCEWASTE.TOHAVEYOURNAMEORORGANIZATIONREMOVEDFROMDISTRIBUTIONLISTSORREDUCETHENUMBEROFCOPIESRECEIVEDBYYOUORYOURORGANIZATION,CONTACTTHEDOCUMENTCONTROLDESK(DCD)ONEXTENSION415-2083TOTALNUMBEROFCOPIESREQUIRED:LTTR18ENCL

0

November3,1997U.S.NuclearRegulatoryCommissionDocumentControlDeskAttn:GuyS.Vissing'rojectDirectorateI-1Washington,D.C.20555Subject:ClarificationofA/EInspectionCommitmentNRCInspectionReportNo.50-244/97-201R.E.GinnaNuclearPowerPlantDocketNo.50-244DearMr.Vissing:DuringtheperiodfromJune9throughAugust15)1997theUS.NuclearRegulatoryCommission(NRC),OfficeofNuclearReactorRegulation(NRR)performedanA/EInspectionoftheR.E.GinnaNuclearPowerPlant.Duringthisinspection,theNRCinferredthatRochesterGas&Electric(RG&E)hadcommittedtoperformingseatleakagetestingfortwoComponentCoolingWater(CCW)Systemcheckvalves.TheintentofthiscorrespondenceistoclarifythetestingcommitmentmadebyRG&E.Also,RG&EwishestonotifytheNRCthatanappropriatealternativetotheclarifiedtestingcommitmenthasbeenperformedduringthecurrentrefuelingoutage.DuetotheshortperiodoftimefromthereceiptofNRCInspectionReport50-244/97-201totheprojectedcompletionofthisrefuelingoutage,RG&EbelievesitisprudenttonotifytheNRCofthecheckvalvetestclarificationandproposedalternativenow,ratherthan60daysafterissuanceoftheinspectionreport.Asrequestedintheinspectionreport,RG&Ewillprovideascheduleforcompletionofcorrectiveactions,whereapplicable,within60daysofissuanceoftheinspectionreport.NRCInspectionReportNo.50-244/97-201,underSectionEl(ConductofEngineering),ItemE1.2.2.2(d)(CCWSystemTesting)lgg]states:"thelicenseestatedthatvalves753AandBwouldbeaddedtothein-serviceinspectionprogramandrequireleaktesting."Itiscorrectthatcheckvalves753Aand753BwillbeaddedtotheGinnaStationInserviceTestingProgram,butwithatestrequirementofcheckvalveclosureverificationtestingandnotseatleakagetesting.II!Ill!(llllll/llllllllllllillfIlla'll

Checkvalves753Aand753BareintheCCWSystemsupplypipingtothereactorcoolantpumpthermalbarriers.Althoughthesevalves'aredesignedaspressureclassboundariesbetweentheReactorCoolantSystemandthelowerpressureCCWSystem,theyarenot,consideredpressureisolationvalves(PIVs)since,shouldathermalbarrierleakoccur,theassociatedCCWpipingisprotectedfromoverpressurebypressurereliefvalvesandtheGinnaStationlicensingbasisconsidersathermalbarrierleakasasmallbreaklossofcoolantaccident.SincethecapacityoftheassociatedpressurereliefvalvesissufficienttoprovideoverpressureprotectionfortheaffectedCCWSystempipingshouldathermalbarrierleakoccur,thesafetyfunctionofcheckvalves753Aand753Bistoclosetomitigatetheconsequencesoftheaccident.Thus,seat,leakageintheclosedpositionisinconsequential.Therefore,RG&Eagreesthatitisprudenttosubjectcheckvalves753Aand753Btoperiodicinservicetestingtoverifyclosurecapability.Inordertoperformclosureverificationtesting,amodificationisrequiredtoinstallsuitabletestconnections.Duetotheshortamountoftimefromwhenthecommitmentforinservicetestingwasmadepriortothecommencementofthecurrentrefuelingoutage,theproperpreparationswerenotabletobemadetoperformthisrequiredmodification.However,RG&Ehasdisassembledcheckvalves753Aand753BduringthisrefuelingoutagetoverifyvalveobturatormovementtotheclosedpositioninaccordancewithOMa-1988,Part10,Section4.3.2.4.ThisactivityisanacceptablealternativepursuanttoPosition2ofNRCGenericLetter89-04and,assuch,doesnotrequirearequestforrelieffromCoderequirements.RG&EintendstomodifytheaffectedpipingsystemtoinstallsuitabletestconnectionsduringtheSpring,1999refuelingoutageandtocommencetheperiodicclosureverificationtestingscheduleinaccordancewiththeGinnaStationInserviceTestingProgramatthattime.Verytrulyyours,/~grq'RobertC.MecredyGJW5482

xc:Mr.GuyS.Vissing(MailStop14B2).ProjectDirectorateI-1Washington,D.C.20555U.S.NuclearRegulatoryCommissionRegionI475AllendaleRoadKingofPrussia,PA19406USNRCGinnaSeniorResidentInspector