Acceptance Review - Relief Request 1B3-4, Comanche Peak Nuclear Power Plant, Unit 1
ML15147A173
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 05/27/2015
From: Balwant Singal
Plant Licensing Branch IV
To: Hope T
Luminant Generation Co
References
TAC MF6132
Download: ML15147A173 (2)


Text

NRR-PMDAPEm Resource From: Singal, Balwant Sent: Wednesday, May 27, 2015 9:07 AM To: 'Hope, Timothy' (Timothy.Hope@luminant.com)

Cc: 'Jack.Hicks@luminant.com' (Jack.Hicks@luminant.com)

Subject:

Acceptance Review - Relief Request 1B3-4, Comanche Peak Nuclear Power Plant, Unit 1 (TAC No. MF6132)

Tim, By letter dated April 22, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15120A038), Luminant Generation Company LLC, requested approval for alternative to the reactor pressure vessel head penetration weld inspection frequency from 10 to 15 years for Comanche Peak Nuclear Power Plant, Unit 1.

The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please contact me.

Balwant K. Singal Senior Project Manager, Comanche Peak and Columbia Balwant.singal@nrc.gov 301-415-3016 1

Hearing Identifier: NRR_PMDA Email Number: 2109 Mail Envelope Properties (192BB59294514E41B5305C3C82867608018BDBE5A04E)

Subject:

Acceptance Review - Relief Request 1B3-4, Comanche Peak Nuclear Power Plant, Unit 1 (TAC No. MF6132)

Sent Date: 5/27/2015 9:07:23 AM Received Date: 5/27/2015 9:07:00 AM From: Singal, Balwant Created By: Balwant.Singal@nrc.gov Recipients:

"'Jack.Hicks@luminant.com' (Jack.Hicks@luminant.com)" <Jack.Hicks@luminant.com>

Tracking Status: None

"'Hope, Timothy' (Timothy.Hope@luminant.com)" <Timothy.Hope@luminant.com>

Tracking Status: None Post Office: HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 1893 5/27/2015 9:07:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:

Recipients Received: