{{#Wiki_filter:1NRR-PMDAPEm Resource From:Lingam, Siva Sent:Wednesday, October 14, 2015 3:26 PM To:Soenen, Philippe R (PNS3@pge.com)
{{#Wiki_filter:1 NRR-PMDAPEm Resource From: Lingam, Siva Sent: Wednesday, October 14, 2015 3:26 PM To: Soenen, Philippe R (PNS3@pge.com)
Cc:Markley, Michael; Jackson, Christopher; E lliott, Robert; Krepel, Sco tt; Grover, Ravinder; Schrader, Kenneth (KJSe@pge.com); 'mjrm@pge.com'
Cc: Markley, Michael; Jackson, Christopher; E lliott, Robert; Krepel, Sco tt; Grover, Ravinder; Schrader, Kenneth (KJSe@pge.com); 'mjrm@pge.com'


==Subject:==
==Subject:==
Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical S pecification 3.4.1 (CAC Nos. MF6731 and MF6732)By letter dated September 16, 2015 (Agencywide Documents Access and Management System Accession No. ML15259A576), Pacific Gas and Electric Company (PG&E, the licensee) submitted a license amendment request 15-07 for Diablo Canyon Power Plant (DCPP), Units 1 and 2, requesting an approval to revise the Reactor Coolant System (RCS) minimum flow specified in Technical Specification (TS) 3.4.1, "RCS Pressure,  
Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical S pecification 3.4.1 (CAC Nos. MF6731 and MF6732)By letter dated September 16, 2015 (Agencywide Documents Access and Management System Accession No. ML15259A576), Pacific Gas and Electric Company (PG&E, the licensee) submitted a license amendment request 15-07 for Diablo Canyon Power Plant (DCPP), Units 1 and 2, requesting an approval to revise the Reactor Coolant System (RCS) minimum flow specified in Technical Specification (TS) 3.4.1, "RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits."  The proposed change is necessary to correct a non-conservative TS value for Unit 1. The purpose of this e-mail is to provide the results of the U.S.
 
Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits."  The proposed change is necessary to correct a non-conservative TS value for Unit 1. The purpose of this e-mail is to provide the results of the U.S.
Nuclear Regulatory Commission (NRC) staff's acceptanc e review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical re view. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.  
Nuclear Regulatory Commission (NRC) staff's acceptanc e review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical re view. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.  


Line 46: Line 44:


Options  Priority:    Standard  Return Notification:    No  Reply Requested:    No  Sensitivity:    Normal  Expiration Date:      Recipients Received:
Options  Priority:    Standard  Return Notification:    No  Reply Requested:    No  Sensitivity:    Normal  Expiration Date:      Recipients Received:
1NRR-PMDAPEm Resource From:Lingam, Siva Sent:Wednesday, October 14, 2015 3:26 PM To:Soenen, Philippe R (PNS3@pge.com)
1 NRR-PMDAPEm Resource From: Lingam, Siva Sent: Wednesday, October 14, 2015 3:26 PM To: Soenen, Philippe R (PNS3@pge.com)
Cc:Markley, Michael; Jackson, Christopher; E lliott, Robert; Krepel, Sco tt; Grover, Ravinder; Schrader, Kenneth (KJSe@pge.com); 'mjrm@pge.com'
Cc: Markley, Michael; Jackson, Christopher; E lliott, Robert; Krepel, Sco tt; Grover, Ravinder; Schrader, Kenneth (KJSe@pge.com); 'mjrm@pge.com'


==Subject:==
==Subject:==
Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical S pecification 3.4.1 (CAC Nos. MF6731 and MF6732)By letter dated September 16, 2015 (Agencywide Documents Access and Management System Accession No. ML15259A576), Pacific Gas and Electric Company (PG&E, the licensee) submitted a license amendment request 15-07 for Diablo Canyon Power Plant (DCPP), Units 1 and 2, requesting an approval to revise the Reactor Coolant System (RCS) minimum flow specified in Technical Specification (TS) 3.4.1, "RCS Pressure,  
Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical S pecification 3.4.1 (CAC Nos. MF6731 and MF6732)By letter dated September 16, 2015 (Agencywide Documents Access and Management System Accession No. ML15259A576), Pacific Gas and Electric Company (PG&E, the licensee) submitted a license amendment request 15-07 for Diablo Canyon Power Plant (DCPP), Units 1 and 2, requesting an approval to revise the Reactor Coolant System (RCS) minimum flow specified in Technical Specification (TS) 3.4.1, "RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits."  The proposed change is necessary to correct a non-conservative TS value for Unit 1. The purpose of this e-mail is to provide the results of the U.S.
 
Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits."  The proposed change is necessary to correct a non-conservative TS value for Unit 1. The purpose of this e-mail is to provide the results of the U.S.
Nuclear Regulatory Commission (NRC) staff's acceptanc e review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical re view. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.  
Nuclear Regulatory Commission (NRC) staff's acceptanc e review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical re view. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.  



Revision as of 22:29, 8 July 2018

2015/10/14 NRR E-mail Capture - Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical Specification 3.4.1 (CAC Nos. MF6731 and MF6732)
ML15287A496
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 10/14/2015
From: Lingam S P
Plant Licensing Branch IV
To: Soenen P R
Pacific Gas & Electric Co
References
MF6731, MF6732
Download: ML15287A496 (2)


Text

1 NRR-PMDAPEm Resource From: Lingam, Siva Sent: Wednesday, October 14, 2015 3:26 PM To: Soenen, Philippe R (PNS3@pge.com)

Cc: Markley, Michael; Jackson, Christopher; E lliott, Robert; Krepel, Sco tt; Grover, Ravinder; Schrader, Kenneth (KJSe@pge.com); 'mjrm@pge.com'

Subject:

Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical S pecification 3.4.1 (CAC Nos. MF6731 and MF6732)By letter dated September 16, 2015 (Agencywide Documents Access and Management System Accession No. ML15259A576), Pacific Gas and Electric Company (PG&E, the licensee) submitted a license amendment request 15-07 for Diablo Canyon Power Plant (DCPP), Units 1 and 2, requesting an approval to revise the Reactor Coolant System (RCS) minimum flow specified in Technical Specification (TS) 3.4.1, "RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits." The proposed change is necessary to correct a non-conservative TS value for Unit 1. The purpose of this e-mail is to provide the results of the U.S.

Nuclear Regulatory Commission (NRC) staff's acceptanc e review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical re view. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed your application and concluded that it does provide technical information in

sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed license amendment request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staff's ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please contact me.

Siva P. Lingam U.S. Nuclear Regulatory Commission Project Manager (NRR/DORL/LPL4-1)

Cooper Nuclear Station Diablo Canyon Nuclear Power Plant Location: O8-D5; Mail Stop: O8-B3 Telephone: 301-415-1564; Fax: 301-415-1222 E-mail address: siva.lingam@nrc.gov

Hearing Identifier: NRR_PMDA Email Number: 2450 Mail Envelope Properties (Siva.Lingam@nrc.gov20151014152600)

Subject:

Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical Specification 3.4.1 (CAC Nos. MF6731 and MF6732)

Sent Date: 10/14/2015 3:26:21 PM Received Date: 10/14/2015 3:26:00 PM From: Lingam, Siva Created By: Siva.Lingam@nrc.gov

Recipients: "Markley, Michael" <Michael.Markley@nrc.gov> Tracking Status: None "Jackson, Christopher" <Christopher.Jackson@nrc.gov> Tracking Status: None "Elliott, Robert" <Robert.Elliott@nrc.gov> Tracking Status: None "Krepel, Scott" <Scott.Krepel@nrc.gov>

Tracking Status: None "Grover, Ravinder" <Ravinder.Grover@nrc.gov> Tracking Status: None "Schrader, Kenneth (KJSe@pge.com)" <KJSe@pge.com> Tracking Status: None "'mjrm@pge.com'" <mjrm@pge.com>

Tracking Status: None "Soenen, Philippe R (PNS3@pge.com)" <PNS3@pge.com> Tracking Status: None Post Office: Files Size Date & Time MESSAGE 2277 10/14/2015 3:26:00 PM

Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: Recipients Received:

1 NRR-PMDAPEm Resource From: Lingam, Siva Sent: Wednesday, October 14, 2015 3:26 PM To: Soenen, Philippe R (PNS3@pge.com)

Cc: Markley, Michael; Jackson, Christopher; E lliott, Robert; Krepel, Sco tt; Grover, Ravinder; Schrader, Kenneth (KJSe@pge.com); 'mjrm@pge.com'

Subject:

Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical S pecification 3.4.1 (CAC Nos. MF6731 and MF6732)By letter dated September 16, 2015 (Agencywide Documents Access and Management System Accession No. ML15259A576), Pacific Gas and Electric Company (PG&E, the licensee) submitted a license amendment request 15-07 for Diablo Canyon Power Plant (DCPP), Units 1 and 2, requesting an approval to revise the Reactor Coolant System (RCS) minimum flow specified in Technical Specification (TS) 3.4.1, "RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits." The proposed change is necessary to correct a non-conservative TS value for Unit 1. The purpose of this e-mail is to provide the results of the U.S.

Nuclear Regulatory Commission (NRC) staff's acceptanc e review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical re view. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed your application and concluded that it does provide technical information in

sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed license amendment request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staff's ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please contact me.

Siva P. Lingam U.S. Nuclear Regulatory Commission Project Manager (NRR/DORL/LPL4-1)

Cooper Nuclear Station Diablo Canyon Nuclear Power Plant Location: O8-D5; Mail Stop: O8-B3 Telephone: 301-415-1564; Fax: 301-415-1222 E-mail address: siva.lingam@nrc.gov

Hearing Identifier: NRR_PMDA Email Number: 2450 Mail Envelope Properties (Siva.Lingam@nrc.gov20151014152600)

Subject:

Diablo Canyon, Units 1 and 2 - Acceptance Review of LAR 15-07 to Revise Reactor Coolant Minimum Flow Specified in Technical Specification 3.4.1 (CAC Nos. MF6731 and MF6732)

Sent Date: 10/14/2015 3:26:21 PM Received Date: 10/14/2015 3:26:00 PM From: Lingam, Siva Created By: Siva.Lingam@nrc.gov

Recipients: "Markley, Michael" <Michael.Markley@nrc.gov> Tracking Status: None "Jackson, Christopher" <Christopher.Jackson@nrc.gov> Tracking Status: None "Elliott, Robert" <Robert.Elliott@nrc.gov> Tracking Status: None "Krepel, Scott" <Scott.Krepel@nrc.gov>

Tracking Status: None "Grover, Ravinder" <Ravinder.Grover@nrc.gov> Tracking Status: None "Schrader, Kenneth (KJSe@pge.com)" <KJSe@pge.com> Tracking Status: None "'mjrm@pge.com'" <mjrm@pge.com>

Tracking Status: None "Soenen, Philippe R (PNS3@pge.com)" <PNS3@pge.com> Tracking Status: None Post Office: Files Size Date & Time MESSAGE 2277 10/14/2015 3:26:00 PM

Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: Recipients Received: