Category:INSPECTION REPORT
MONTHYEARML20217B4801999-09-21021 September 1999 Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment ML20154R7901988-09-22022 September 1988 Insp Rept 70-1201/88-10 on 880915-16.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Plant Operations,Training & Followup on Operational Safety Assessment ML20151K1361988-07-18018 July 1988 Insp Rept 70-1201/88-08 on 880613-15.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Exposure Controls,Staffing,Radwaste Mgt, Transportation & Followup on Previous Enforcement Issues ML20195H9901988-06-15015 June 1988 Insp Rept 70-1201/88-06 on 880518-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid Gaseous Radwaste,Environ Monitoring & Confirmatory Measurements ML20154A7001988-04-22022 April 1988 Insp Rept 70-1201/88-03 on 880411-15.No Violations & Deviations Noted.Major Areas Inspected:Followup on Inspector Identified Items & Measurement Controls ML20148F6191988-03-0808 March 1988 Insp Rept 70-1201/88-01 on 880201-03.Violation Noted.Major Areas Inspected:Areas of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & IE Info Notices ML20150B1371988-03-0202 March 1988 Insp Rept 70-1201/88-02 on 880210-12.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Monitoring ML20238F6021987-09-0404 September 1987 Insp Rept 70-1201/87-06 on 870819-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20215A5431987-05-29029 May 1987 Insp Rept 70-1201/87-05 on 870518-21.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & Info Notices ML20205Q1941987-03-25025 March 1987 Partially Withheld Insp Rept 70-1201/87-03 on 870223-27 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Measurement,Training Records,Receipts of SNM & Followup on Inspector Identified Items ML20207U0721987-02-27027 February 1987 Operational Safety Assessment Insp Rept 70-1201/87-02 on 870202-06.No Violations Identified.Four Weaknesses & 32 Improvement Items Re Emergency Contingency Planning,Fire Protection,Maint & Nuclear Criticality Safety Identified 1999-09-21
[Table view] Category:NRC-GENERATED
MONTHYEARML20217B4801999-09-21021 September 1999 Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment ML20154R7901988-09-22022 September 1988 Insp Rept 70-1201/88-10 on 880915-16.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Plant Operations,Training & Followup on Operational Safety Assessment ML20151K1361988-07-18018 July 1988 Insp Rept 70-1201/88-08 on 880613-15.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Exposure Controls,Staffing,Radwaste Mgt, Transportation & Followup on Previous Enforcement Issues ML20195H9901988-06-15015 June 1988 Insp Rept 70-1201/88-06 on 880518-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid Gaseous Radwaste,Environ Monitoring & Confirmatory Measurements ML20154A7001988-04-22022 April 1988 Insp Rept 70-1201/88-03 on 880411-15.No Violations & Deviations Noted.Major Areas Inspected:Followup on Inspector Identified Items & Measurement Controls ML20148F6191988-03-0808 March 1988 Insp Rept 70-1201/88-01 on 880201-03.Violation Noted.Major Areas Inspected:Areas of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & IE Info Notices ML20150B1371988-03-0202 March 1988 Insp Rept 70-1201/88-02 on 880210-12.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Monitoring ML20238F6021987-09-0404 September 1987 Insp Rept 70-1201/87-06 on 870819-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20215A5431987-05-29029 May 1987 Insp Rept 70-1201/87-05 on 870518-21.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & Info Notices ML20205Q1941987-03-25025 March 1987 Partially Withheld Insp Rept 70-1201/87-03 on 870223-27 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Measurement,Training Records,Receipts of SNM & Followup on Inspector Identified Items ML20207U0721987-02-27027 February 1987 Operational Safety Assessment Insp Rept 70-1201/87-02 on 870202-06.No Violations Identified.Four Weaknesses & 32 Improvement Items Re Emergency Contingency Planning,Fire Protection,Maint & Nuclear Criticality Safety Identified 1999-09-21
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20217B4801999-09-21021 September 1999 Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20196H9201999-06-25025 June 1999 Notice of Violation from Insp on 990524-28.Violation Noted: on 990525,inspector Observed That Gate 6 Was Not Closed & Locked & Was Not Attended or in Use ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20249A2131998-06-0404 June 1998 Notice of Violation from Insp on 980511-15.Violation Noted: from 1993 Until Feb 1998,Framatome Cogema Fuels Did Not Make or Cause to Be Made,Surveys Neccessary to Show Compliance w/10CFR20.2003(a) to Evaluate Concentrations ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20203A0821997-12-0505 December 1997 Notice of Violation from Insp on 971103-07.Violation Noted: Health Physics Audit Conducted 970128-0203 Only Included Review of RP Procedures in Context of Impact on EP & Did Not Consist of Review of Effectiveness of Procedural Controls ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6401997-06-0606 June 1997 Notice of Violation from Insp on 970512-15.Violation Noted: No Fire Safety Insp Was Conducted During 1996 at Facility ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5471997-05-0202 May 1997 Notice of Violation from Insp on 970331-0403.Violation Noted:On 970402,approx One Hundred Nylon Straps Were Being Temporarily Stored in Fuel Assembly Storage Area in Anticipation of Future Usage ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5421997-03-11011 March 1997 Notice of Deviation from Insp on 970224-0306.Deviation Noted:Licensee Failure to Meet Commitment That Procedure Would Be Completed by 960430 ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20135D6831997-03-0404 March 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $12,500.Noncompliance Noted:From 960914-25, Procedure MA-587 Not Adhered To,Operators Performing Fuel Assembly Off Loading Operations Failed to Ensure Unloading ML20137M0451997-02-27027 February 1997 EN-97-016:on 970304,notice of Proposed Imposition of Civil Penalty in Amount of $12,500 Issued to Licensee.Action Based on Five Violations Involving Event low-enriched,unirradiated Fuel Assembly Inadvertently Returned in Original Container ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20129H0651996-10-23023 October 1996 Notice of Violation from Insp on 960910,13 & 23.Violation Noted:Licensee Failed to Review,Document Results & Take Appropriate Corrective Actions for Vegetation Sample Collected May 1995 That Exceeded Licensee Action Limits ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing PNO-II-90-036, on 900707,licensee Notified NRC That tractor- Trailer Carrying 6 Containers of New Fuel Assemblies Destined for Power Plant in Arkansas Had Been Involved in Accident.Two Containers Had Damaged Outer Seals1990-07-0909 July 1990 PNO-II-90-036:on 900707,licensee Notified NRC That tractor- Trailer Carrying 6 Containers of New Fuel Assemblies Destined for Power Plant in Arkansas Had Been Involved in Accident.Two Containers Had Damaged Outer Seals ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment 1999-09-21
[Table view] |
Text
_-
1 U. S. NUCLEAR REGULATORY COMMISSION REGION II Docket No.: 70 1201 License No.: SNM 1168 Report No.: 70-1201/97-04 Licensee: Babcock and Wilcox Commercial Fuel d/b/a Framatome Cogema Fuels Facility: Commerical Nuclear Fuel Plant Location: Lynchburg, VA Dates: May 12-15, 1997 Inspectors: W. J. Tobin, Senior Safeguards Inspector Approved by: E. J. McAlpine. Chief Fuel Facilities Branch Division of Nuclear Materials Safety l
l Enclosure 2 i
I ~
9706120167 970606 PDR ADOCK 07001201 C PDR l
4 EXECUTIVE
SUMMARY
B&W COMMERCIAL FUEL COMPANY d/b/a FRAMATONE FUELS COMPANY NRC INSPECTION REPORT N0. 70-1201/97-04 The focus of this announced routine inspection was to observe, quantify, and evaluate the licensee's fire protection program. Specifically, the primary areas of inspection dealt with the licensee's efforts to prevent, detect and suppress fires. The inspection resulted in the following assessment. )
FIRE PROTECTION Based upon the results of this inspection, it appears that the licensee's fire protection program is meeting the goals and intent of NRC criteria. Except as noted below, the licensee was complying with its License Conditions.
Strengths were identified in the licensee's practice of protecting zirconium from fire in the Machine Shop, the fire safety analysis of the NUKEM project prior to start-up, and the cooperative relationship with the local fire department.
l A violation was identified for failure to conduct audits of the fire protection program in 1996, and a Non Cited Violation was identified for failure to conduct the fourth quarter Safety Review Board meeting in 1996.
The licensee's plans to update the Pre Fire Plan (including the hazard analysis), add several pieces of equipment to the monthly inspection checklist, and evaluate the need for redundant communication capabilities to the Campbell County Emergency Center from the Guard House.
Attachments:
Partial List of Persons Contacted .
Inspection Procedures Used !
List of Items Opened Closed and Discussed List of Acronyms l
l I
l
t 1 .
I REPORT DETAILS I
I. SAFETY OPERATIONS i t
l FIRE PROTECTION OF FUEL FACILITIES (IP 88055) f
- 1. Fire Prevention Detection and Suppression !
- a. Insoection Sc.pgt f The licensee's program to prevent, detect, and suppress fires was '
inspected vis a vis License Conditions 2.3, " Safety Review Board,"
2.7, " Audits " 6.2, " Fire Protection,".and 6.3, " Emergency .
Utilities." In addition to these performance standards, other ;
criteria utilized by the inspector included the NRC Generic j Letter 95 01, titled "NRC Staff Technical Position on Fire ;
Protection for Fuel Cycle Facilities" and the licensee's response l
< dated March 8, 1995.
.l The inspector reviewed the following licensee procedures:
AS 1106 Emergency Procedure. Revision 20 '
AS 1116 LMF Fire Equipment Control, Revision 10 AS 1120 Safety Review Board, Revision 5 !
AS 1122-Storage of Flammable Liquid, Revision 0 >
AS 1130 LMF Equipment Maintenance, Revision 11 i AS 1138 Ignition Source Permit, Revision 4 i 1
The inspector reviewed the following drawings: l FA 96024-Hydrant and Valve Locations October 5,1996 l PE 1439ED1 LMF Offices. July 21, 1993 !
PE 1439ED12-SERF 3. July 21,1993 The inspector toured the following areas:
Service Equipment Refurbishment Facility (SERF) 1, 2, and 3 i S1 Storage Building I Dry Chemical Storage Shed Maintenance Garage Emergency Operations Facility Laser Welding Shop Records Storage Facility Com) uter Room Mac11ne Shop.
Guard House c
Electrical Shop l
Fuel Bundle Assembly Room i
.- .. ~ ~, ___, __ , _- __ . . _ _ . . . _ . . __
l .
i 2
Guidance found in the NRC Branch Technical Position on Fire l Protection for Fuel Facilities, published in the Federal Register
- on August 10, 1992, was also relied upon during this inspection.
I b. Observations and Findinas I (1) Fire Prevention j
! To perform the functions of a fire safety committee, the '
licensee has established a Safety Review Board (SRB) which is tasked with management oversight for plant safety cnd for compliance with State and Federal regulations. The MB is i chaired by the Manager of Safety and Licensing. Mem!ership :
includes managers from manufacturing, engineering, yoduct '
quality, material control, health physics, and reguatory compliance. Other delegates attend the SRB meetir93 as appropriate. The inspector reviewed the SRB mee' ;ng reports for 1996 and noted that ALARA concerns, qualit': assurance I
audits, NRC inspection results, American Nuc'.ar Insurance !
(ANI) audit results, personnel accident reN rts, industrial i safety tours and housekeeping were topic.s of discussion. In l accordance with Procedure AS 1120. " Safety Review Board," l Revision 5, dated December 8, 1993, the SRB is responsible l for evaluating additions and modifications to facilities and l conducting pre-operational safety analysis with the specific j concern of flammable liquids, combustible solids, sparks, flames and hazardous chemicals. At the direction of the SRB, a s)ecial pre operational inspection was conducted of the NUKEi project. As a result of that effort extra fire extinguishers were installed, G-1 powder was placed at each lathe operation, ventilation filters were replaced more often and housekeeping was improved.
1 The inspector noted that the fourth quarter meeting of the SRB was not conducted in 1996 as is required by License Condition 2.3 and Procedure AS 1120. The Chairperson of the !
SRB had documented her efforts to hold the meeting but was not able to do so because of the, "... numerous conflicts of I members ... and aggressive implementation of corrective actions resulting from the VVER incident..." The inspector further found that no safety issues were left unaddressed until the first meeting in 1997. To correct this failure, the licensee's management emahasized to members the importance of rescheduling t1eir duties to attend the SRB ,
required meetings. In accordance with the NRC Enforcement l Policy the failure to conduct the fourth quarter of 1996 SRB-meeting is considered a Non Cited Violation (NCV) (NCV 70-
- 1201/97 04 01).
l t
i .
! I
{
I 3 I i
Regarding NRC Generic Letter 95 01, the licensee has a " Fire Plan" dated August 23, 1993, which reveals the presence of :
emergency lights and electric power panels, location of G 1 !
powder buckets, and the location of extinguishers and i detectors for each work place. Also as a part of this Plan are Material Safety Data Sheets relative to the chemicals and health hazards found in these work areas. The Plan furnishes the reader specific safety precautions, ,
l fire / explosion data, reactivity stability warnings and other !
pertinent information. The Plan was prepared with the
~
! assistance of the local fire responders and is used as a training document. It addresses such items as ,
,. access / egress, ventilation, suppression systems, preventing j l the use of water in moderation areas and occupancy. The <
! inspector toured several work areas using the Plan and found !
l several examples where the location of fire safety equipment !
was not current. The licensee stated that the Plan will be l L revised. i During the tour of the facility, the inspector observed i numerous Hazardous Liquid Storage Containers used to store j flammable gas, paint and solvents. Housekeeping was l adequately enforced. The inspector noticed that the >
portable welding carts had fire extinguishers pre positioned i on the cart to assure extinguishers were readily available. 1 The inspector did not observe any welding in process, _ i however, Procedure AS 1138 titled " Ignition Source Permits" l l requires a permit issued by an area supervisor.
Additionally, the inspector reviewed permits issued to date in 1997, and determined that a 35 foot radius is required i around such welding and that surveillance is also required for 30 minutes after the completion of the job.
Security patrol clock stations were also found to be serving i
an additional purpose of >roviding fire watches in that the-clock stations required tie watchman to tour remote locations on a random schedule.
! The inspector reviewed the most recent (January 1997) audit performed by the fire insurer. Findings were relative to adding to the sprinkler system, removing combustible materials from ceilings and walls, sensitivity testing of smoke detectors and procedure revision. The licensee agreed to correct all of the findings except to adding sprinklers to the office areas which are "No Smoking" areas where fire extinguishers are conveniently located.
l !
l l l l i
4 -
License Condition 2.7, Audits and Inspections, requires that independent auditors shall conduct semi annual audits of the i fire safety program. During 1996, there were no fire safety :
audits conducted. The failure to conduct the required semi- '
annual fire safety audits in 1996 is a Violation (VIO) of License Condition 2.7 (VIO 70-1201/97 04-02).
(2) Fire Detection '
Theinspectortouredthefacilityandnotedthe!resenceof smoke and heat detectors appro the ;
ceilings and over work areas. priately located along These detectors i with !
radiation detectors, fire alarm pull boxes and water :
-pressure flow detectors annunciated both audibly and !
. visually in the Guard House. It is the responsibility of i the watchperson to telephone the Campbell County Emergency Center for offsite assistance. There was some confusion l among the security force as to what to do in the unlikely i l- loss of telephone service. The licensee will formalize a redundant communication capability to clarify that contingency.
Battery operated smoke detectors, which alarm locally, are l located in kitchens.
) Inside the zirconium grinding machines in the Machine Shop there are light or " flash" detectors which shutdown the air vacuum system and annunciate in the Guard House. The i inspector was present for the annunciation of a radiation I detector being tested by the technicians and verified that the audible alarm was loud enough to attract the attention
! of the watchperson who normally sits facing away from the visual read out on the face of the wall mounted alarm panel.
The inspector located one flame detector in the Cleaning Room which was not listed on the licensee's monthly test l record. This detector was one of several such detectors and
! was immediately added to the monthly test sheet. The licensee stated the operability of this detector would be verified promptly.
The inspector-observed the licensee test the uninterruptable power supply to the fire detection system and noted no spurious alarms. The watchperson in the Guard House received an alarm that the system was on backup power. The j insmetor randomly verified the operability of emergency
- lig1 ting by pressing the " Test" button which activated the i
local batteries.
4 i
.. . . . -.---- --- .= - - _ - .- . - - -
I During this inspection, the inspector verified that the i public address system was loud enough to be heard throughout l the work places, including the cafeteria. Pull boxes and strobe lights were adequate in number and location. ,
(3) Fire Suppression ;
Wet sprinkler systems are provided in SERF 3 and 4 Records !
Storage Trailer, North Offices, most of the Machine Shop, Shipping and Receiving, Furnace and Laser Welding areas. A 1 dry system is located at the Chemical Storage Building. The inspector accompanied the technicians and witnessed the ;
monthly test of the sprinkler system in SERF 3 and the 1
. Shipping and Receiving areas. The test included discharging water into the relief drain, thus exercising the loss of pressure water flow alarm, and opening the end of line drain which simulated activating the sprinklers and that ,
associated alarm. These tests were successful. l Fire extinguishers (A, B, C, and D) were conviently located at strategic locations. The presence of G 1 Powder was also
. noted to be in proper locations. Of particular interest, in the Machine Shop, were G-1 powder reservoirs placed above zirconium collection drums such that in the event of a flash fire the powder was already located to automatically drop down onto the collection drum and suppress the fire.
Fire hydrants, hose reels and Position Indicator Valves were found to be clear of obstructions and effectively in service.
The inspector observed that between the Manufacturing Facility and the North Offices there is a metal door, at the t foot of the adestrian ramp, which is equipped with a "U.L. ;
Combination )oor Closer and Holder with Integral Smoke Detector." A red light in the top of the door jamb is energized from a cable that extends out of the wall. The inspector could find no one who could speak authoritatively about the operability of Unis door. No drawings or ;
specifications could be locatea regarding the door. The door is not on the monthly test records and consequently is not tested. It is the licensee's intent to test this door, determine its function and, if the door serves a fire protection purpose then test it monthly.
The licensee has established a seven wrson Fire Brigade !
which is present on the day shift. T1e ins metor toured the l Emergency Operation Facility which houses tie Brigade's equipment and vehicle. Training records were reviewed. '
Discussions with the Fire Chief were positive. Equipment and supplies were appropriate.The inspector visited with the ;
offsite volunteer fire department and learned of the l
l
! 6 training and site visits recently conducted. Equipment was !
found to be well suited to respond to this facility. l l Members were familiar with the physical layout of the l licensee's buildings and with the role of the Fire Brigade. l
- c. Conclusion The licensee is meeting the intent and goals of the NRC's fire protection criteria. With the exce)tions as noted above, the licensee is in compliance with its icense Conditions. The ,
response to Generic Letter 95 01 was acceptable. l II. HANAGEMENT MEETINGS Exit Meeting The scope and findings of this inspection were summarized on May 15. 1997, with those persons so indicated in the Attachment. The potential violations were discussed with the senior licensee manager present. No dissenting i comments were expressed. No proprietary information was identified.
l l
p b
l
_-. _ _ . . - . . _ ~ _ . _ _ -_ _ _ . . _ . - _ _ .
i I
e 7 ,
ATTACHMENT l '
! LIST OF PERSONS CONTACTED l
Licensee Personnel
- T. Allsop, Senior Health Physicist R. Canody. Process Supervisor '
- C. Carr, Plant Vice President
- G. Elliott, Health and Safety Manager i D. Gordon, Senior Health Physicist
- A. Jenkins. Facility Manager R. Joseph. Electrical Supervisor D. Mabry, Safety Technician M. Moore. Facilities Engineer i
- L. Morrell. Compliance Officer l T. Self, Electrician .
C. Vandergrift. Mechanical Supervisor
- D. White, Safety Monitor '
- J. Whitt, Facility Manager Other Personnel '
D. Cam > bell, Fireman
- R. Gralam, Wackenhut Security C. Toller, County Fire Commissioner
- Denotes attendance at Exit Meeting INSPECTION PROCEDURES USED ,
IP 88055 Fire Protection at Fuel Facilities IP 92702 Follow Up to Prior Item l
i LIST OF ITEMS OPEED, CLOSED, AND DISCUSSED ,
OPENED Item Number Status Description 70-1201/97 04 01 Opened NCV - Failure to conduct quarterly meeting of SRB.
70 1201/97 04 02 Opened VIO Failure to audit fire safety program semi-annually.
. .- . - _ - _ - . .. - . -. _-. . . . . . . . . . - . = . .
i 8
I CLOSED l
Item Number Status Descriotion l
70 1201/97 02 01 Closed DEV By letter dated April 4,1997, the !
licensee responded to this Deviation. The i inspector verified training has been conducted in Administrative Procedure 1703 01. The Deviation was also part of Team Leader Meetings -
topics in March 31 and April 1 sessions. The inspector witnessed two examples of response inputs being furnished to the Safety Manager on May 15.
LIST OF ACRONYMS ALARA As low As Reasonably Achievable !
ANI American Nuclear Insurer SERF Support Equipment Refurbishment Facility -
SRB Safety Review Board UL Underwriters Laboratory )
1 l
l l