Category:INSPECTION REPORT
MONTHYEARML20217B4801999-09-21021 September 1999
[Table view]Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment ML20154R7901988-09-22022 September 1988 Insp Rept 70-1201/88-10 on 880915-16.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Plant Operations,Training & Followup on Operational Safety Assessment ML20151K1361988-07-18018 July 1988 Insp Rept 70-1201/88-08 on 880613-15.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Exposure Controls,Staffing,Radwaste Mgt, Transportation & Followup on Previous Enforcement Issues ML20195H9901988-06-15015 June 1988 Insp Rept 70-1201/88-06 on 880518-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid Gaseous Radwaste,Environ Monitoring & Confirmatory Measurements ML20154A7001988-04-22022 April 1988 Insp Rept 70-1201/88-03 on 880411-15.No Violations & Deviations Noted.Major Areas Inspected:Followup on Inspector Identified Items & Measurement Controls ML20148F6191988-03-0808 March 1988 Insp Rept 70-1201/88-01 on 880201-03.Violation Noted.Major Areas Inspected:Areas of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & IE Info Notices ML20150B1371988-03-0202 March 1988 Insp Rept 70-1201/88-02 on 880210-12.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Monitoring ML20238F6021987-09-0404 September 1987 Insp Rept 70-1201/87-06 on 870819-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20215A5431987-05-29029 May 1987 Insp Rept 70-1201/87-05 on 870518-21.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & Info Notices ML20205Q1941987-03-25025 March 1987 Partially Withheld Insp Rept 70-1201/87-03 on 870223-27 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Measurement,Training Records,Receipts of SNM & Followup on Inspector Identified Items ML20207U0721987-02-27027 February 1987 Operational Safety Assessment Insp Rept 70-1201/87-02 on 870202-06.No Violations Identified.Four Weaknesses & 32 Improvement Items Re Emergency Contingency Planning,Fire Protection,Maint & Nuclear Criticality Safety Identified 1999-09-21 Category:MANUFACTURER/VENDOR/ENGINEER MONTHYEARML20062F7731990-11-16016 November 1990
[Table view]Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment ML20154R7901988-09-22022 September 1988 Insp Rept 70-1201/88-10 on 880915-16.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Plant Operations,Training & Followup on Operational Safety Assessment ML20151K1361988-07-18018 July 1988 Insp Rept 70-1201/88-08 on 880613-15.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Exposure Controls,Staffing,Radwaste Mgt, Transportation & Followup on Previous Enforcement Issues ML20195H9901988-06-15015 June 1988 Insp Rept 70-1201/88-06 on 880518-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid Gaseous Radwaste,Environ Monitoring & Confirmatory Measurements ML20154A7001988-04-22022 April 1988 Insp Rept 70-1201/88-03 on 880411-15.No Violations & Deviations Noted.Major Areas Inspected:Followup on Inspector Identified Items & Measurement Controls ML20148F6191988-03-0808 March 1988 Insp Rept 70-1201/88-01 on 880201-03.Violation Noted.Major Areas Inspected:Areas of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & IE Info Notices ML20150B1371988-03-0202 March 1988 Insp Rept 70-1201/88-02 on 880210-12.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Monitoring ML20238F6021987-09-0404 September 1987 Insp Rept 70-1201/87-06 on 870819-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20215A5431987-05-29029 May 1987 Insp Rept 70-1201/87-05 on 870518-21.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & Info Notices ML20205Q1941987-03-25025 March 1987 Partially Withheld Insp Rept 70-1201/87-03 on 870223-27 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Measurement,Training Records,Receipts of SNM & Followup on Inspector Identified Items ML20207U0721987-02-27027 February 1987 Operational Safety Assessment Insp Rept 70-1201/87-02 on 870202-06.No Violations Identified.Four Weaknesses & 32 Improvement Items Re Emergency Contingency Planning,Fire Protection,Maint & Nuclear Criticality Safety Identified ML20210U0951987-02-0909 February 1987 Partially Withheld Insp Rept 70-1201/87-01 on 870120-21 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Facility Organization & Mgt Controls ML20210C1101987-01-0707 January 1987 Partially Withheld Insp Rept 70-1201/86-09 on 861207-11 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Facility Operations & Internal Controls & Records & Repts ML20214L3751986-08-22022 August 1986 Insp Rept 70-1201/86-07 on 860806.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Protection ML20209G2401986-08-22022 August 1986 Insp Rept 70-1201/86-05 on 860708-10 & 16.Violation Noted: Failure to Brace Radioactive Matl Container to Prevent Shifting Under Conditions Normally Incident to Transport ML20206S7651986-06-20020 June 1986 Partially Withheld Insp Rept 70-1201/86-04 on 860604 (Ref 10CFR2.790 & 73.21).No Noncompliance Noted.Major Areas Reviewed:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20199H7821986-06-16016 June 1986 Insp Rept 70-1201/86-03 on 860602-03.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization & Controls,Training,Nuclear Criticality Safety,Operations Review & Maint & Surveillance ML20155A1431986-03-26026 March 1986 Insp Rept 70-1201/86-01 on 860310-14.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection, Solid Radwaste Mgt & Transportation of Radioactive Matls ML20136C2181985-11-0606 November 1985 Insp Rept 70-1201/85-10 on 851015-18.No Violations or Deviations Noted.Major Areas Inspected:Measurement Control & Statistics.Details Withheld (Ref 10CFR2.790 & 73.21) ML20132B3991985-09-18018 September 1985 Insp Rept 70-1201/85-08 on 850903-06.No Violations or Deviations Identified.Major Areas Inspected:Measurement Control & Statistics.Details Withheld (Ref 10CFR2.790 & 73.21) ML20137F6241985-08-20020 August 1985 Insp Rept 70-1201/85-07 on 850715-18.No Violations or Deviations Noted.Major Areas Inspected:Facility Operations & Internal Controls,Measurements,Records & Repts.Details Withheld (Ref 10CFR2.790 & 73.21) ML20133P8721985-07-31031 July 1985 Insp Rept 70-1201/85-06 on 850717-19.No Violation or Deviation Noted.Major Areas Inspected:Mgt Organization & Controls,Nuclear Criticality Safety,Procedures,Operations Review & Audits ML20133E6181985-07-12012 July 1985 Insp Rept 70-1201/85-05 on 850611-14.Violation Noted: Individual Allowed to Wear Respirator More than 12 Months After Last Physical & SNM Shipped to Another Licensee W/O Ensuring Type of SNM Authorized to Receive ML20132D7811985-06-28028 June 1985 Insp Rept 70-1201/85-04 on 850612-14.Violation Noted:Failure to Submit Semiannual Effluent Rept Specifying Quantity of Radionuclides Actually Released During Second Half 1984 ML20128M0981985-06-18018 June 1985 Insp Rept 70-1201/85-03 on 850606.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness ML20132B0991985-05-0606 May 1985 Insp Rept 70-1201/85-02 on 850424-26.No Violation or Deviation Noted.Major Areas Inspected:Mgt Organization & Controls Training,Nuclear Criticality Safety,Procedures & Operations Review & Audits ML20128L9451985-04-17017 April 1985 Insp Rept 70-1201/85-01 on 850401-05.No Violation or Deviation Noted.Major Areas Inspected:Measurement Control & Statistics & Inspector Followup Items.Proprietary Details Withheld (Ref 10CFR2.790(d) & 73.21) ML20058H2281982-07-27027 July 1982 IE Safeguards Insp Rept 70-1201/82-10 on 820628-0701.No Noncompliance Noted.Major Areas Inspected:Physical Inventory Observation & Records & Repts.Details Withheld (Ref 10CFR2.790) ML20058C3041982-07-16016 July 1982 IE Safeguards Insp Rept 70-1201/82-09 on 820615-18.No Noncompliance Noted.Major Areas Inspected:Program of Accounting for SNM Shipped & Received.Details Withheld (Ref 10CFR2.790) ML20058G4321982-07-13013 July 1982 IE Insp Rept 70-1201/82-08 on 820616-18.No Noncompliance Noted.Major Areas Inspected:Organization,Facility Changes & Mods,Safety Committees,Operations & Previously Identified Items ML20150E2891978-11-30030 November 1978 IE Inspec Rept 70-1201/78-16 on 781114-16 During Which No Items of Noncompliance Were Noted.Major Areas Inspected: Measurements,Mgt of Nuc Matls Control Sys & Independent Inspec Efforts.Details Withheld (Ref 10CFR2.790) ML20148R3961978-11-0606 November 1978 IE Inspec Rept 70-1201/78-13 on 781010-12 During Which No Items of Noncompliance Were Noted.Major Areas Inspected: Safety Comm,Procedures Control,Oper review,follow-up on Items of Noncompliance,Observation of Emergency Drill ML20148G2881978-09-19019 September 1978 IE Inspec Rept 70-1201/78-12 on 780814-17 During Which 1 Item of Noncompliance Was Noted:Failure to Follow Posted Nuc Criticality Safety Instru 1990-09-11 Category:INSPECTION REPORT MONTHYEARML20217B4801999-09-21021 September 1999
[Table view]Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment ML20154R7901988-09-22022 September 1988 Insp Rept 70-1201/88-10 on 880915-16.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Plant Operations,Training & Followup on Operational Safety Assessment ML20151K1361988-07-18018 July 1988 Insp Rept 70-1201/88-08 on 880613-15.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Exposure Controls,Staffing,Radwaste Mgt, Transportation & Followup on Previous Enforcement Issues ML20195H9901988-06-15015 June 1988 Insp Rept 70-1201/88-06 on 880518-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid Gaseous Radwaste,Environ Monitoring & Confirmatory Measurements ML20154A7001988-04-22022 April 1988 Insp Rept 70-1201/88-03 on 880411-15.No Violations & Deviations Noted.Major Areas Inspected:Followup on Inspector Identified Items & Measurement Controls ML20148F6191988-03-0808 March 1988 Insp Rept 70-1201/88-01 on 880201-03.Violation Noted.Major Areas Inspected:Areas of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & IE Info Notices ML20150B1371988-03-0202 March 1988 Insp Rept 70-1201/88-02 on 880210-12.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Monitoring ML20238F6021987-09-0404 September 1987 Insp Rept 70-1201/87-06 on 870819-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20215A5431987-05-29029 May 1987 Insp Rept 70-1201/87-05 on 870518-21.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & Info Notices ML20205Q1941987-03-25025 March 1987 Partially Withheld Insp Rept 70-1201/87-03 on 870223-27 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Measurement,Training Records,Receipts of SNM & Followup on Inspector Identified Items ML20207U0721987-02-27027 February 1987 Operational Safety Assessment Insp Rept 70-1201/87-02 on 870202-06.No Violations Identified.Four Weaknesses & 32 Improvement Items Re Emergency Contingency Planning,Fire Protection,Maint & Nuclear Criticality Safety Identified 1999-09-21 Category:NRC-GENERATED MONTHYEARML20217B4801999-09-21021 September 1999
[Table view]Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment ML20154R7901988-09-22022 September 1988 Insp Rept 70-1201/88-10 on 880915-16.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Plant Operations,Training & Followup on Operational Safety Assessment ML20151K1361988-07-18018 July 1988 Insp Rept 70-1201/88-08 on 880613-15.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Exposure Controls,Staffing,Radwaste Mgt, Transportation & Followup on Previous Enforcement Issues ML20195H9901988-06-15015 June 1988 Insp Rept 70-1201/88-06 on 880518-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid Gaseous Radwaste,Environ Monitoring & Confirmatory Measurements ML20154A7001988-04-22022 April 1988 Insp Rept 70-1201/88-03 on 880411-15.No Violations & Deviations Noted.Major Areas Inspected:Followup on Inspector Identified Items & Measurement Controls ML20148F6191988-03-0808 March 1988 Insp Rept 70-1201/88-01 on 880201-03.Violation Noted.Major Areas Inspected:Areas of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & IE Info Notices ML20150B1371988-03-0202 March 1988 Insp Rept 70-1201/88-02 on 880210-12.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt & Environ Monitoring ML20238F6021987-09-0404 September 1987 Insp Rept 70-1201/87-06 on 870819-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20215A5431987-05-29029 May 1987 Insp Rept 70-1201/87-05 on 870518-21.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Solid Radwaste Mgt,Transportation of Radioactive Matls & Info Notices ML20205Q1941987-03-25025 March 1987 Partially Withheld Insp Rept 70-1201/87-03 on 870223-27 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Measurement,Training Records,Receipts of SNM & Followup on Inspector Identified Items ML20207U0721987-02-27027 February 1987 Operational Safety Assessment Insp Rept 70-1201/87-02 on 870202-06.No Violations Identified.Four Weaknesses & 32 Improvement Items Re Emergency Contingency Planning,Fire Protection,Maint & Nuclear Criticality Safety Identified 1999-09-21 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARML20217B4801999-09-21021 September 1999
[Table view]Insp Rept 70-1201/99-03 on 990823-27.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Training ML20211F7051999-08-19019 August 1999 Insp Rept 70-1201/99-02 on 990726-27.No Violations Noted. Major Areas Inspected:Decommissioning Activities Associated with Wet Weather Stream ML20210G0141999-07-28028 July 1999 Insp Rept 70-1201/99-202 on 990716.No Violations Noted. Major Areas Inspected:Plant Activities,Administrative & Engineered Controls,Ncs Function & Chemical Safety ML20196H9311999-06-25025 June 1999 Insp Rept 70-1201/99-01 on 990524-28.Violations Noted.Major Areas Inspected:Operations,Maint,Training,Transportation & Mgt Programs ML20196H9201999-06-25025 June 1999 Notice of Violation from Insp on 990524-28.Violation Noted: on 990525,inspector Observed That Gate 6 Was Not Closed & Locked & Was Not Attended or in Use ML20206A5791999-04-23023 April 1999 Partially Withheld Insp Rept 70-1201/99-201 (Ref 10CFR2.790) on 990323-26.Details Withheld ML20198L1801998-12-28028 December 1998 Partially Withheld Insp Rept 70-1201/98-203 on 981130-1203. Details Withheld,Per 10CFR2.790 ML20154C2341998-09-18018 September 1998 Insp Rept 70-1201/98-06 on 980824-28.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Solid Radwaste Mgt & Housekeeping ML20239A5041998-08-21021 August 1998 Insp Rept 70-1201/98-04 on 980727-31.No Violations Noted. Major Areas Inspected:Review Licensee Fire Protection Program ML20236H1931998-06-12012 June 1998 Insp Rept 70-1201/98-03 on 980518-22.No Violations Noted. Major Areas Inspected:Review of Licensee Radiation Protection Program ML20249A2141998-06-0404 June 1998 Insp Rept 70-1201/98-02 on 980511-15.Violations Noted.Major Areas Inspected:Plant Operations,Waste Mgt,Transportation, Maint/Surveillance & Training ML20249A2131998-06-0404 June 1998 Notice of Violation from Insp on 980511-15.Violation Noted: from 1993 Until Feb 1998,Framatome Cogema Fuels Did Not Make or Cause to Be Made,Surveys Neccessary to Show Compliance w/10CFR20.2003(a) to Evaluate Concentrations ML20216J3361998-04-15015 April 1998 Insp Rept 70-1201/98-01 on 980309-27.No Violations Noted. Major Areas Inspected:Licensee Actions for Decommissioning of Wet Weather Stream ML20216F1571998-04-10010 April 1998 Partially Withheld Insp Rept 70-1201/98-202 on 980309-12.No Violations Noted.Details Withheld,Per 10CFR2.790(d) ML20217Q3101998-03-0505 March 1998 Partially Withheld Insp Rept 70-1201/98-201 on 980120-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20198Q2021998-01-12012 January 1998 Insp Rept 70-1201/97-205 on 971217.No Violations Noted.Major Areas Inspected:Receiving & Storage Vault Areas,Pellet Loading Room,Fuel Rod Processing Area & Fuel Bundle Assembly & Storage Areas ML20203E5701997-12-15015 December 1997 Insp Rept 70-1201/97-204 on 971117-18.No Violations Noted. Major Areas Inspected:Chemical Safety,Fire Protection Assessment & Sys & Testing & Emergency Response ML20203A0891997-12-0505 December 1997 Insp Rept 70-1201/97-06 on 971103-07.Violations Noted:Major Areas Inspected:Licensee Operations,Mgt Controls,Training, Environ Protection,Transportation & Waste Mgt Programs ML20203A0821997-12-0505 December 1997 Notice of Violation from Insp on 971103-07.Violation Noted: Health Physics Audit Conducted 970128-0203 Only Included Review of RP Procedures in Context of Impact on EP & Did Not Consist of Review of Effectiveness of Procedural Controls ML20149F9101997-07-11011 July 1997 Insp Rept 70-1201/97-05 on 970616-20.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Programs for Operation Safety,Mgt Organization & Controls, Conduct & Control of Maint & Testing of Safety Equipment ML20140E6401997-06-0606 June 1997 Notice of Violation from Insp on 970512-15.Violation Noted: No Fire Safety Insp Was Conducted During 1996 at Facility ML20140E6471997-06-0606 June 1997 Insp Rept 70-1201/97-04 on 970512-15.Violations Noted.Major Areas Inspected:Licensee Fire Protection Program ML20148B5471997-05-0202 May 1997 Notice of Violation from Insp on 970331-0403.Violation Noted:On 970402,approx One Hundred Nylon Straps Were Being Temporarily Stored in Fuel Assembly Storage Area in Anticipation of Future Usage ML20148B5531997-05-0202 May 1997 Insp Rept 70-1201/97-03 on 970331-0403.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls & Matls Control & Accounting ML20140E2871997-04-23023 April 1997 Partially Withheld Insp Rept 70-1201/97-203 on 970325-27 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected: Review of Response to Notice of Violation & Proposed Imposition of Civil Penalty, ML20136J5421997-03-11011 March 1997 Notice of Deviation from Insp on 970224-0306.Deviation Noted:Licensee Failure to Meet Commitment That Procedure Would Be Completed by 960430 ML20136J5651997-03-11011 March 1997 Insp Rept 70-1201/97-02 on 970224 & 970306.Deviation Noted. Major Areas Inspected:Physical Security Plan ML20135D6831997-03-0404 March 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $12,500.Noncompliance Noted:From 960914-25, Procedure MA-587 Not Adhered To,Operators Performing Fuel Assembly Off Loading Operations Failed to Ensure Unloading ML20137M0451997-02-27027 February 1997 EN-97-016:on 970304,notice of Proposed Imposition of Civil Penalty in Amount of $12,500 Issued to Licensee.Action Based on Five Violations Involving Event low-enriched,unirradiated Fuel Assembly Inadvertently Returned in Original Container ML20134N8651997-02-14014 February 1997 Insp Rept 70-1201/97-01 on 970113-17.No Violations Noted. Major Areas Inspected:Radiological Controls,Environmental Protection & Waste Mgt ML20147E5491997-02-14014 February 1997 Insp Rept 70-1201/97-202 on 970213 & 14.No Violations Noted. Major Areas Inspected:Adminstrative Practices for Ncs,Ncs Function,Plant Activities,Ncs Change Control,Ncr Training Activities,Ncs Insp,Audits & Investigations & NCS Er ML20129H0651996-10-23023 October 1996 Notice of Violation from Insp on 960910,13 & 23.Violation Noted:Licensee Failed to Review,Document Results & Take Appropriate Corrective Actions for Vegetation Sample Collected May 1995 That Exceeded Licensee Action Limits ML20129H0901996-10-23023 October 1996 Insp Rept 70-1201/96-04 on 960910,13 & 23.Violations Noted. Major Areas Inspected:Solid Radwaste,Effluents,Environ Monitoring Program,Onsite Storage & Waste Manifests ML20129B0451996-09-0606 September 1996 Partially Withheld Insp Rept 70-1201/96-201 on 960819-21. One Noncited Violation,One Unresolved Item & Four New Ifis Opened.Major Areas Inspected:Resolution,Measurement Control, Inventory & Recordkeeping.Details Withheld (Ref 10CFR2.790) ML20057E3401993-09-29029 September 1993 Insp Rept 70-1201/93-04 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness,Including Maint of Selected Emergency & Fire Protection Equipment,W/Respect to Operational Readiness ML20057E5841993-09-28028 September 1993 Insp Rept 70-1201/93-03 on 930830-0902.No Violations or Deviations Noted.Major Areas Inspected:Organization & Staffing,Audits,Radiation Protection Training,Procedures, External Exposure Control & Control of Radioactive Matl ML20056G8811993-08-26026 August 1993 Insp Rept 70-1201/93-02 on 930809-12.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20127G6651993-01-0808 January 1993 Insp Rept 70-1201/92-09 on 921207-11.No Violations Noted. Major Areas Inspected:Mgt Controls,Training,Nuclear Criticality Safety,Operations & Maint & Surveillance Testing ML20062F7731990-11-16016 November 1990 Insp Rept 70-1201/90-06 on 901015-19.One Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness Program ML20058B2551990-10-16016 October 1990 Insp Rept 70-1201/90-05 on 900917-20.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring, Instrumentation & Audits ML20059K8511990-09-11011 September 1990 Insp Rept 70-1201/90-04 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations & Maint & Surveillance Testing PNO-II-90-036, on 900707,licensee Notified NRC That tractor- Trailer Carrying 6 Containers of New Fuel Assemblies Destined for Power Plant in Arkansas Had Been Involved in Accident.Two Containers Had Damaged Outer Seals1990-07-0909 July 1990 PNO-II-90-036:on 900707,licensee Notified NRC That tractor- Trailer Carrying 6 Containers of New Fuel Assemblies Destined for Power Plant in Arkansas Had Been Involved in Accident.Two Containers Had Damaged Outer Seals ML20248C8191989-09-27027 September 1989 Insp Rept 70-1201/89-06 on 890828-30.No Violations or Deviations Noted.Major Areas Inspected:Radiological Effluent Monitoring & Control,Radiological Environ Monitoring & QC ML20248B7331989-09-22022 September 1989 Insp Rept 70-1201/89-07 on 890911-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review, Maint & Followup on Previous Insp Findings ML20245K7501989-08-0909 August 1989 Insp Rept 70-1201/89-05 on 890717-20.No Violations & Deviations Noted.Major Areas Inspected:Review of Radiation Protection Program,Including Daily Radiation Protection Activities & Transportation of Radioactive Matl ML20245A7601989-05-26026 May 1989 Insp Rept 70-1201/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Implementation of Agreement Between Us & IAEA for Application of Safeguards in Us ML20247H5131989-05-16016 May 1989 Partially Withheld Insp Rept 70-1201/89-04 on 890502 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Requirements for Physical Protection of Low Enriched Nuclear Matl ML20247M2071989-05-12012 May 1989 Insp Rept 70-1201/89-02 on 890412-14 & 0504-05.No Violations or Deviations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents,Radiological Environ Monitoring & Radiological Confirmatory Measurement ML20247E9311989-03-23023 March 1989 Insp Rept 70-1201/89-01 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Plant Operations,Maint & Followup on Previously Identified Items ML20155F0521988-09-28028 September 1988 Partially Withheld Insp Rept 70-1201/88-09 on 880906-09 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Matl Control & Accountability Assessment 1999-09-21 |
Text
- . _ , _ - - - _ _ - -
UNITED STATES
[paafog,#o* .
IUCLEAR REGULATURY COMMISSION
,3 '
',* CEolON11 3 .j 101 MAIIETTA STCEET.ND.
ATL ANTA, otoRot A 30323 W t
- s.,
/ Arp 2 21988 Report No.: 70-1201/88-03 Licensee: Babcock and Wilcox Company Commercial Nuclear Fuel Plant Lynchburg, VA 24505 Docket No.: 70-1201 License No.: SNM-1168 Facility Name: Commercial Nuclear Fuel Plant Inspection Conducted: April 11-15, 1988 Inspector: MC
- 0. W. Jones,' Statisticiah ~1 L 4 [21[8 8 Date Signed Approved by: bW' N O 4[22/ 8 8 E. J. McAlpine, Chief U N
~
Date Signed Material Control and Accountability Section A Nuclear Material Safety and Safeguards Branch Division of Radiation Safety and Safeguards
SUMMARY
Scope: The areas examined during this routine, unannounced inspection included followup on inspector identified items and measurement controls.
Results: In the areas inspected, violations or deviations were not identified.
&% 1 '