ML061000237: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:FENOC, FirstEnergy Nuclear Operating Company 5501 North State Route 2 Oak Hsrbor, Ohio 43449 Mark B. Bezilla 419-321-7676 Vice President  
{{#Wiki_filter:FENOC,                                                                                             5501 North State Route 2 FirstEnergy Nuclear Operating Company                                                              Oak Hsrbor, Ohio 43449 Mark B. Bezilla                                                                                               419-321-7676 Vice President - Nuclear                                                                               Fax: 419-321-7582 Docket Number 50-346 License Number NPF-3 Serial Number 3246 April 6,       2006 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555-0001
-Nuclear Fax: 419-321-7582 Docket Number 50-346 License Number NPF-3 Serial Number 3246 April 6, 2006 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555-0001


==Subject:==
==Subject:==
Technical Specification 4.4.5.5(a)
Technical Specification 4.4.5.5(a) Report of Steam Generator Tube Plugging Ladies and Gentlemen:
Report of Steam Generator Tube Plugging Ladies and Gentlemen:
This letter is submitted in accordance with the requirements of the Davis-Besse Nuclear Power Station (DBNPS) Unit Number I, Operating License, Appendix A, Technical Specifications.
This letter is submitted in accordance with the requirements of the Davis-Besse Nuclear Power Station (DBNPS) Unit Number I, Operating License, Appendix A, Technical Specifications.
Technical Specification 4.4.5.5(a) requires FirstEnergy Nuclear Operating Company (FENOC) to report to the Nuclear Regulatory Commission (NRC) the number of tubes plugged in each steam generator (SG) following each inservice inspection of steam generator tubes.As a result of the Cycle 14 Refueling Outage SG tube inservice inspection findings and outage activities, 7 tubes were newly plugged in SG I -B and 10 tubes were newly plugged in SG 2-A.No regulatory commitments are made in this letter. If there are any questions or if additional information is required, please contact Mr. Gregory A. Dunn, Manager -FENOC Fleet Licensing, at (330) 315 -7243.Very truly yours, TSC/X 0n\
Technical Specification 4.4.5.5(a) requires FirstEnergy Nuclear Operating Company (FENOC) to report to the Nuclear Regulatory Commission (NRC) the number of tubes plugged in each steam generator (SG) following each inservice inspection of steam generator tubes.
Docket Number 50-346 License Number NPF-3 Serial Number 3246 Page 2 cc: Regional Administrator, NRC Region III NRCINRR Project Manager NRC Senior Resident Inspector Utility Radiological Safety Board Docket Number 50-346 License Number NPF-3 Serial Number 3246 Attachment COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station (DBNPS) in this document.
As a result of the Cycle 14 Refueling Outage SG tube inservice inspection findings and outage activities, 7 tubes were newly plugged in SG I-B and 10 tubes were newly plugged in SG 2-A.
Any other actions discussed in the submittal represent intended or planned actions by the DBNPS. They are described only for information and are not regulatory commitments.
No regulatory commitments are made in this letter. If there are any questions or if additional information is required, please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330) 315 -7243.
Please contact Mr. Gregory A. Dunn, Manager -FENOC Fleet Licensing, at (330-315-7243) of any questions regarding this document or any associated regulatory commitments.
Very truly yours,
[OMMITMENT DUE DATE one N/A}}
                                        /X TSC 0n\
 
Docket Number 50-346 License Number NPF-3 Serial Number 3246 Page 2 cc:   Regional Administrator, NRC Region III NRCINRR Project Manager NRC Senior Resident Inspector Utility Radiological Safety Board
 
Docket Number 50-346 License Number NPF-3 Serial Number 3246 Attachment COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station (DBNPS) in this document. Any other actions discussed in the submittal represent intended or planned actions by the DBNPS. They are described only for information and are not regulatory commitments. Please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330-315-7243) of any questions regarding this document or any associated regulatory commitments.
[OMMITMENT                                       DUE DATE one                                             N/A}}

Latest revision as of 21:09, 23 November 2019

Technical Specification 4.4.5.5(a) Report of Steam Generator Tube Plugging
ML061000237
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 04/06/2006
From: Bezilla M
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
3246
Download: ML061000237 (3)


Text

FENOC, 5501 North State Route 2 FirstEnergy Nuclear Operating Company Oak Hsrbor, Ohio 43449 Mark B. Bezilla 419-321-7676 Vice President - Nuclear Fax: 419-321-7582 Docket Number 50-346 License Number NPF-3 Serial Number 3246 April 6, 2006 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555-0001

Subject:

Technical Specification 4.4.5.5(a) Report of Steam Generator Tube Plugging Ladies and Gentlemen:

This letter is submitted in accordance with the requirements of the Davis-Besse Nuclear Power Station (DBNPS) Unit Number I, Operating License, Appendix A, Technical Specifications.

Technical Specification 4.4.5.5(a) requires FirstEnergy Nuclear Operating Company (FENOC) to report to the Nuclear Regulatory Commission (NRC) the number of tubes plugged in each steam generator (SG) following each inservice inspection of steam generator tubes.

As a result of the Cycle 14 Refueling Outage SG tube inservice inspection findings and outage activities, 7 tubes were newly plugged in SG I-B and 10 tubes were newly plugged in SG 2-A.

No regulatory commitments are made in this letter. If there are any questions or if additional information is required, please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330) 315 -7243.

Very truly yours,

/X TSC 0n\

Docket Number 50-346 License Number NPF-3 Serial Number 3246 Page 2 cc: Regional Administrator, NRC Region III NRCINRR Project Manager NRC Senior Resident Inspector Utility Radiological Safety Board

Docket Number 50-346 License Number NPF-3 Serial Number 3246 Attachment COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station (DBNPS) in this document. Any other actions discussed in the submittal represent intended or planned actions by the DBNPS. They are described only for information and are not regulatory commitments. Please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330-315-7243) of any questions regarding this document or any associated regulatory commitments.

[OMMITMENT DUE DATE one N/A