FENOC, 5501 North State Route 2 FirstEnergy Nuclear Operating Company Oak Hsrbor, Ohio 43449 Mark B. Bezilla 419-321-7676 Vice President - Nuclear Fax: 419-321-7582 Docket Number 50-346 License Number NPF-3 Serial Number 3246 April 6, 2006 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555-0001

Subject:

Technical Specification 4.4.5.5(a) Report of Steam Generator Tube Plugging Ladies and Gentlemen:

This letter is submitted in accordance with the requirements of the Davis-Besse Nuclear Power Station (DBNPS) Unit Number I, Operating License, Appendix A, Technical Specifications.

Technical Specification 4.4.5.5(a) requires FirstEnergy Nuclear Operating Company (FENOC) to report to the Nuclear Regulatory Commission (NRC) the number of tubes plugged in each steam generator (SG) following each inservice inspection of steam generator tubes.

As a result of the Cycle 14 Refueling Outage SG tube inservice inspection findings and outage activities, 7 tubes were newly plugged in SG I-B and 10 tubes were newly plugged in SG 2-A.

No regulatory commitments are made in this letter. If there are any questions or if additional information is required, please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330) 315 -7243.

Very truly yours,

/X TSC 0n\

Docket Number 50-346 License Number NPF-3 Serial Number 3246 Page 2 cc: Regional Administrator, NRC Region III NRCINRR Project Manager NRC Senior Resident Inspector Utility Radiological Safety Board

Docket Number 50-346 License Number NPF-3 Serial Number 3246 Attachment COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station (DBNPS) in this document. Any other actions discussed in the submittal represent intended or planned actions by the DBNPS. They are described only for information and are not regulatory commitments. Please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330-315-7243) of any questions regarding this document or any associated regulatory commitments.