{{#Wiki_filter:TO DEEPWELL PUMP MOTOR CONTROLS P-q VENT RECYCLE LINE VENT FROM PLANT WATE R WE L Ls LS I I LG I L LS WELL WATER TANK 0 VE R F LOW QHS T I PS ACTIVATED CARBON FILTERS LC HYPOCHLORITE MIXING TEE FC LG SERVICE WATER AND CHLORINE CONTACT TANK LAHL I LS--I I I I~LS PSV (FILTER REVERSE OSMOSIS Y CONCENTRATE WEI L WATER BOOSTER PUMPS ATM BACK-FLUSH TO WASTE PACKAGE UNITS WITH HIGH PRESSURE PUMPS TO WASTE PSV SERVICE AIR ATM H Y POOH LO R IT E TANK LG QHS I HS SERVICE COLD WATER SUPPLY TO UTILITY STATIONS, AIR CONDITIONING 5 MISC SERVICES PSV PC LG HYDROPNEUMATIC TANK I UNIT-I)LC QHS HYPOCHLORITE METERING PUMPS PSV TO DISTRIBUTION SYSTEM TYPICAL FOR EACH UNIT I I I SERVICE WATER PUMPS Hs 3 L PS TO UNIT I SERVICE HOT WATER SUPPLY Ts I I L OTHER SERVICES SIMILAR TO UNIT I DISTRIBUTION SYS TO UNIT 2 TO UNIT 3 BACKFLOW PREVENTOR TYPICAL SERVICE WATER STORAGE HEATER Arizona Nuclear Power Project Palo Verde Nuclear Generating Station Units 1, 2&3 10401.U A 2 2 A P 4-A 2 0 NOTE: SYSTEM IS NON NUCLEAR SAFETY BASIC FLOW DIAGRAM SERVICE WATER SYSTEM Figure 9.2-6}}
{{#Wiki_filter:RECYCLE TO DEEPWELL PUMP MOTOR CONTROLS   q                                                                                                        LINE P
VENT VENT LS QHS T
I FROM PLANT WATE R WE L Ls                                                                                                                                                                                                                               LAHL I             WELL WATER                                                                                                                                             LC I              TANK I
LG                                                                                                                                                HYPOCHLORITE MIXING TEE               SERVICE LS  I I
L                                                                                                                                                                                  WATER LS                                                            PS  ACTIVATEDCARBON FILTERS                                                                                              AND                           I CHLORINE                         I CONTACT I
TANK FC            LG                                ~LS 0 VE R F LOW WEI L WATER PSV       ( FILTER BACK-FLUSH REVERSE OSMOSIS       Y PACKAGE UNITS WITH HIGH CONCENTRATE TO BOOSTER PUMPS                               TO WASTE         PRESSURE PUMPS         WASTE ATM PSV ATM H Y POOH LO R IT E TANK             LG SERVICE AIR                                                                                        QHS I
HS PC HYDROPNEUMATIC LG          TANK      LC I UNIT-I)
PSV                                            I I
SERVICE COLD WATER SUPPLY QHS I        SERVICE WATER TO UTILITY                                                                                                                                                                                                                   PUMPS Hs        3 STATIONS, AIR CONDITIONING                                                                                                                                   HYPOCHLORITE 5 MISC SERVICES                                             PSV                                                                                 METERING PUMPS                                                       L                          PS TO DISTRIBUTION SYSTEM TYPICAL FOR EACH UNIT             TO UNIT I SERVICE HOT WATER SUPPLY TO Ts                                                                                                                                                     SIMILAR TO   UNIT 2 UNIT I DISTRIBUTION SYS   TO I
UNIT 3 I
L                                                                                                                OTHER SERVICES BACKFLOW PREVENTOR TYPICAL SERVICE WATER                                                                                                                                                                   Arizona Nuclear Power Project STORAGE HEATER Palo Verde Nuclear Generating Station Units 1, 2 & 3 NOTE:                                                      BASIC FLOW DIAGRAM SYSTEM IS NON NUCLEAR SAFETY                            SERVICE WATER SYSTEM 10401.U A 2 2 A P 4- A 2 0                                                                                                                                                                                                                                     Figure 9.2-6}}

Latest revision as of 20:33, 20 October 2019

Figure 9.2-6, Basic Flow Diagram Service Water System.
ML18193A062
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 07/12/2018
From:
Arizona Nuclear Power Project
To:
Office of Nuclear Reactor Regulation
References
9.2-6
Download: ML18193A062 (1)


Text

RECYCLE TO DEEPWELL PUMP MOTOR CONTROLS q LINE P

VENT VENT LS QHS T

I FROM PLANT WATE R WE L Ls LAHL I WELL WATER LC I TANK I

LG HYPOCHLORITE MIXING TEE SERVICE LS I I

L WATER LS PS ACTIVATEDCARBON FILTERS AND I CHLORINE I CONTACT I

TANK FC LG ~LS 0 VE R F LOW WEI L WATER PSV ( FILTER BACK-FLUSH REVERSE OSMOSIS Y PACKAGE UNITS WITH HIGH CONCENTRATE TO BOOSTER PUMPS TO WASTE PRESSURE PUMPS WASTE ATM PSV ATM H Y POOH LO R IT E TANK LG SERVICE AIR QHS I

HS PC HYDROPNEUMATIC LG TANK LC I UNIT-I)

PSV I I

SERVICE COLD WATER SUPPLY QHS I SERVICE WATER TO UTILITY PUMPS Hs 3 STATIONS, AIR CONDITIONING HYPOCHLORITE 5 MISC SERVICES PSV METERING PUMPS L PS TO DISTRIBUTION SYSTEM TYPICAL FOR EACH UNIT TO UNIT I SERVICE HOT WATER SUPPLY TO Ts SIMILAR TO UNIT 2 UNIT I DISTRIBUTION SYS TO I

UNIT 3 I

L OTHER SERVICES BACKFLOW PREVENTOR TYPICAL SERVICE WATER Arizona Nuclear Power Project STORAGE HEATER Palo Verde Nuclear Generating Station Units 1, 2 & 3 NOTE: BASIC FLOW DIAGRAM SYSTEM IS NON NUCLEAR SAFETY SERVICE WATER SYSTEM 10401.U A 2 2 A P 4- A 2 0 Figure 9.2-6