MONTHYEARTMI-10-079, Submittal of Relief Requests Associated with the Fourth Inservice Inspection Interval2010-08-10010 August 2010 Submittal of Relief Requests Associated with the Fourth Inservice Inspection Interval Project stage: Request ML1026402792010-09-21021 September 2010 Non-Acceptance, with Opportunity to Supplement, for TMI-1 RR-I4R-02, TAC No. ME4519 Project stage: Other ML1026406132010-09-23023 September 2010 Supplemental Information Needed for Acceptance of Requested Licensing Action Request for Relief l4R-02, Fourth Inservice Inspection Interval, Alternate Risk Informed Selection and Examination Criteria for Project stage: Acceptance Review TMI-10-101, Three Mile, Unit 1, Supplemental Information Request - Fourth Inservice Inspection (ISI) Interval Relief Request I4R-022010-10-0808 October 2010 Three Mile, Unit 1, Supplemental Information Request - Fourth Inservice Inspection (ISI) Interval Relief Request I4R-02 Project stage: Supplement ML1029303472010-10-21021 October 2010 Acceptance of Requested Licensing Action Request for Relief l4R-02, Fourth Inservice Inspection Interval, Alternate Risk Informed Selection and Examination Criteria for Pressure Retaining Welds Project stage: Acceptance Review TMI-10-111, Submittal of Relief Requests Associated with the Fourth Inservice Inspection (ISI) Interval - Relief Request I4R-012010-10-29029 October 2010 Submittal of Relief Requests Associated with the Fourth Inservice Inspection (ISI) Interval - Relief Request I4R-01 Project stage: Request ML1034405552010-12-10010 December 2010 Electronic Transmission, Draft Request for Additional Information Regarding Relief Request 14R-02 Project stage: Draft RAI ML1034001582010-12-20020 December 2010 Request for Additional Information Regarding Fourth Inservice Inspection Interval Relief Requests l4R-02 and l4R-04 Project stage: RAI TMI-11-007, Response to Request for Additional Information Concerning Relief Requests Associated with the Fourth Inservice Inspection Interval2011-01-25025 January 2011 Response to Request for Additional Information Concerning Relief Requests Associated with the Fourth Inservice Inspection Interval Project stage: Response to RAI ML1111804942011-04-28028 April 2011 Electronic Transmission, Draft Request for Additional Information Regarding Fourth Interval Inservice Inspection Relief Request I4R-04 Project stage: Draft RAI ML1111806402011-05-0606 May 2011 Request for Additional Information Regarding Fourth Inservice Inspection Interval Relief Request I4R-04 Project stage: RAI TMI-11-084, Response to Request for Additional Information Concerning Relief Requests Associated with the Fourth Inservice Inspection (ISI) Interval2011-05-11011 May 2011 Response to Request for Additional Information Concerning Relief Requests Associated with the Fourth Inservice Inspection (ISI) Interval Project stage: Response to RAI ML1117304752011-07-20020 July 2011 Fourth Inservice Inspection Interval Relief Requests I4R-02, I 4R-03, I4R-04, I4R-05, and I4R-06 Project stage: Other 2010-09-21
[Table View] |
|
---|
Category:Inservice/Preservice Inspection and Test Report
MONTHYEARNMP2L2700, Co. - Submittal of Proposed Alternative to Utilize Code Case N-879 for Plants2019-04-30030 April 2019 Co. - Submittal of Proposed Alternative to Utilize Code Case N-879 for Plants ML18085A1682018-03-19019 March 2018 Inspection Report for End of Cycle 21 Refueling Outage ML18009A4342018-01-0808 January 2018 Submittal of T1R22 Refueling Outage Lnservice Inspection Owner'S Activity Report ML17087A0822017-03-28028 March 2017 Submittal of the Update to the Fifth Ten-Year Interval Lnservice Testing Program ML16144A7912016-05-21021 May 2016 Inspection Report for Refueling Outage T1R21 TMI-16-023, T1R21 Refueling Outage Inservice Inspection (Isli) Owner'S Activity Report and Attachments2016-02-22022 February 2016 T1R21 Refueling Outage Inservice Inspection (Isli) Owner'S Activity Report and Attachments TMI-15-048, Submittal of the Update to the Fifth Ten-Year Interval Lnservice Testing Program2015-04-13013 April 2015 Submittal of the Update to the Fifth Ten-Year Interval Lnservice Testing Program TMI-14-058, (TMI-1) - Steam Generator Tube Inspection Report2014-05-22022 May 2014 (TMI-1) - Steam Generator Tube Inspection Report TMI-14-069, Submittal of the Fifth Ten-Year Interval Inservice Testing Program2014-05-16016 May 2014 Submittal of the Fifth Ten-Year Interval Inservice Testing Program TMI-14-029, T1R20 Refueling Outage Inservice Inspection (ISI) Owner'S Activity Report and Attachments2014-02-25025 February 2014 T1R20 Refueling Outage Inservice Inspection (ISI) Owner'S Activity Report and Attachments TMI-13-048, Response to Request for Additional Information - Submittal of End of Interval Relief Request RR-12-012013-03-18018 March 2013 Response to Request for Additional Information - Submittal of End of Interval Relief Request RR-12-01 TMI-13-043, Response to Request for Additional Information - Relief Request VR-01 Associated with the Fifth Inservice Testing (IST) Interval2013-03-15015 March 2013 Response to Request for Additional Information - Relief Request VR-01 Associated with the Fifth Inservice Testing (IST) Interval TMI-13-038, Relief Request RR-12-02 Concerning the Installation of a Full Structural Weld Overlay on the Lower Cold Leg Letdown Nozzle Dissimilar Metal Welds and Alloy 600 Safe-End2013-03-11011 March 2013 Relief Request RR-12-02 Concerning the Installation of a Full Structural Weld Overlay on the Lower Cold Leg Letdown Nozzle Dissimilar Metal Welds and Alloy 600 Safe-End TMI-12-071, Transmittal of Steam Generator Tube Inspection Report2012-05-15015 May 2012 Transmittal of Steam Generator Tube Inspection Report TMI-12-016, T1R19 Refueling Outage Inservice Inspection (ISI) Owner'S Activity Report and Attachments2012-02-20020 February 2012 T1R19 Refueling Outage Inservice Inspection (ISI) Owner'S Activity Report and Attachments TMI-11-158, Submittal of Relief Request PR-05 Associated with the Fourth Inservice Testing (IST) Interval2011-10-28028 October 2011 Submittal of Relief Request PR-05 Associated with the Fourth Inservice Testing (IST) Interval ML11105A1602011-04-0505 April 2011 2010 Augmented Reactor Building (Iwl) In-Service Inspection, Topical Report 204, Rev. 0 TMI-11-060, Response to a Request for Additional Information - Relief Request RR-10-01 Concerning Control Rod Drive Housing Examinations Associated with the Third Inservice Inspection Interval2011-04-0505 April 2011 Response to a Request for Additional Information - Relief Request RR-10-01 Concerning Control Rod Drive Housing Examinations Associated with the Third Inservice Inspection Interval TMI-11-061, ISI Program Plan, Fourth Ten-Year Inspection Interval2011-03-15015 March 2011 ISI Program Plan, Fourth Ten-Year Inspection Interval TMI-11-007, Response to Request for Additional Information Concerning Relief Requests Associated with the Fourth Inservice Inspection Interval2011-01-25025 January 2011 Response to Request for Additional Information Concerning Relief Requests Associated with the Fourth Inservice Inspection Interval TMI-10-101, Three Mile, Unit 1, Supplemental Information Request - Fourth Inservice Inspection (ISI) Interval Relief Request I4R-022010-10-0808 October 2010 Three Mile, Unit 1, Supplemental Information Request - Fourth Inservice Inspection (ISI) Interval Relief Request I4R-02 TMI-10-079, Submittal of Relief Requests Associated with the Fourth Inservice Inspection Interval2010-08-10010 August 2010 Submittal of Relief Requests Associated with the Fourth Inservice Inspection Interval TMI-10-069, Supplement to Cycle 17 Refueling (T1R18) Inservice Inspection (ISI) Summary Report2010-07-0707 July 2010 Supplement to Cycle 17 Refueling (T1R18) Inservice Inspection (ISI) Summary Report TMI-10-033, TMI Unit 1 T1 R18 Outage ASME Code Section XI Inservice Inspection (ISI) Form NIS-1 Owner'S Report for Inservice Inspections, Part I, TMI Unit 1 Form NIS-2 Owner'S Report for Repairs or Replacements, and Topical Report Number 203, Part 22010-04-21021 April 2010 TMI Unit 1 T1 R18 Outage ASME Code Section XI Inservice Inspection (ISI) Form NIS-1 Owner'S Report for Inservice Inspections, Part I, TMI Unit 1 Form NIS-2 Owner'S Report for Repairs or Replacements, and Topical Report Number 203, Part 2 ML1014002732010-04-21021 April 2010 TMI Unit 1 T1 R18 Outage ASME Code Section Xi Inservice Inspection (ISI) Form NIS-1 Owner'S Report for Inservice Inspections, Part I, TMI Unit 1 Form NIS-2 Owner'S Report for Repairs or Replacements, and Topical Report Number 203, Part 1 TMI-09-101, Submittal of the Fourth Ten-Year Interval Inservice Testing Program, Revision 1, for September 23, 2004 Through September 22, 20142009-08-14014 August 2009 Submittal of the Fourth Ten-Year Interval Inservice Testing Program, Revision 1, for September 23, 2004 Through September 22, 2014 TMI-09-086, Submittal of Concerning Unsatisfactory Laboratory Performance Tests2009-07-30030 July 2009 Submittal of Concerning Unsatisfactory Laboratory Performance Tests ML0605404122006-02-15015 February 2006 Cycle 16 Refueling (T1R16) Inservice Inspection (ISI) Summary Report ML0529403472005-10-14014 October 2005 Additional Information Regarding Kinetic Expansion Inspection and Repair Criteria ML0325213752003-08-27027 August 2003 TMI, Unit 1 - Third Ten-Year Inservice Inspection (ISI) Program, Supplemental Information, Risk-Informed Inservice Inspection Program Alternative to the ASME Boiler & Pressure Vessel Code, Section XI Requirements for Class 1 & 2 Piping Weld ML0227701442002-10-0808 October 2002 (TMI-1), Amergen Energy Company, LLC (Amergen), March 5, 2002, Cycle 14, Inservice Inspection (ISI) Summary Report ML0228302112002-10-0101 October 2002 Third Ten-Year Interval Inservice Inspection (ISI) Program Risk-Informed Inservice Inspection Program Alternative to the ASME Boiler and Pressure Vessel Code Section XI Requirements for Class 1 and 2 Piping Welds 2019-04-30
[Table view] Category:Letter
MONTHYEARML24256A0422024-10-0404 October 2024 Updated Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24242A3032024-09-0909 September 2024 Letter - Three Mile Island Station, Unit 2, Issuance of Amendment No. 68, Historic and Cultural Resources IR 05000320/20240012024-08-28028 August 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report Nos. 05000320/2024001 and 05000320/2024002 ML24240A2222024-08-27027 August 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24220A2742024-08-15015 August 2024 Request for Additional Information Clarification Call Regarding Three Mile Island Station, Unit 2, Amended Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24135A3292024-08-0909 August 2024 Amendment No 68, Historic and Cultural Resources Cover Letter IR 07200077/20240012024-06-18018 June 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 07200077/2024001 ML24157A3672024-06-13013 June 2024 Updated Post-Shutdown Decommissioning Activities Report Request for Additional Information Transmittal Letter ML24135A1972024-06-13013 June 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0091 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24120A3242024-05-24024 May 2024 TMI-2 Email to Fws RS-24-055, 2023 Corporate Regulatory Commitment Change Summary Report2024-05-17017 May 2024 2023 Corporate Regulatory Commitment Change Summary Report ML24121A2472024-04-29029 April 2024 and Three Mile Island, Unit 2 - 2023 Occupational Radiation Exposure Annual Report ML24120A2552024-04-29029 April 2024 Annual Radiological Environmental Operating Report ML24113A0212024-04-18018 April 2024 (TMI-2), Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-24-002, Constellation Energy Generation, LLC - Annual Property Insurance Status Report2024-04-0101 April 2024 Constellation Energy Generation, LLC - Annual Property Insurance Status Report ML24088A0122024-03-28028 March 2024 Notification of Amended Post-Shutdown Decommissioning Activities Report (PSDAR) in Accordance with 10 CFR 50.82(a)(7), Revision 6 ML24065A0042024-03-28028 March 2024 Submittal of 2023 Aircraft Movement Data Annual Report ML24092A0012024-03-28028 March 2024 (TMI-2), Decommissioning Trust Fund Annual Report ML24085A2152024-03-25025 March 2024 (TMI-2) - Annual Notification of Property Insurance Coverage RS-24-023, Report on Status of Decommissioning Funding.2024-03-22022 March 2024 Report on Status of Decommissioning Funding. ML24052A0602024-03-20020 March 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0061 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24075A0062024-03-14014 March 2024 List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML24074A3922024-03-14014 March 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML24073A2312024-03-13013 March 2024 and Three Mile Island Nuclear Station, Unit 2 - Management Change ML24044A0092024-02-12012 February 2024 License Amendment Request – Three Mile Island, Unit 2, Historic and Cultural Resources Review, Response to Request for Additional Information IR 05000320/20230042024-02-0707 February 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023004 ML24038A0222024-02-0505 February 2024 Achp Letter on Section 106 Programmatic Agreement Participation IR 05000289/20230062024-01-29029 January 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 05000289/2023006 ML23342A1242024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23325A1092024-01-0505 January 2024 Review of the Management Plan for Three Mile Island Station, Unit No. 2, Debris Material ML23354A2062023-12-20020 December 2023 (TMI-2), Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23354A2112023-12-20020 December 2023 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 IR 05000320/20230032023-11-28028 November 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report No. 05000320/2023003 ML23243A9082023-08-29029 August 2023 Shpo Letter to TMI-2 Regarding Section 106 Activities IR 05000320/20230022023-08-17017 August 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023002 ML23216A1732023-08-14014 August 2023 Consultation Letter to Christine Turner for TMI-2 ML23216A1752023-08-14014 August 2023 Consultation Letter to Joanna Cain for TMI-2 ML23216A1772023-08-14014 August 2023 Consultation Letter to Rebecca Countess for TMI-2 IR 05000289/20230052023-08-14014 August 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report 05000289/2023005 ML23216A1742023-08-14014 August 2023 Consultation Letter to David Morrison for TMI-2 ML23216A1782023-08-14014 August 2023 Consultation Letter to Steve Letavic for TMI-2 ML23221A1402023-08-0808 August 2023 (TMI-2), Response to Requests for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML23200A1882023-07-31031 July 2023 TMI-2 Correction Letter Amendment 67 ML23209A7632023-07-28028 July 2023 Letter from PA Shpo to TMI-2 Solutions on Cultural and Historic Impacts of Decommissioning ML23192A8272023-07-10010 July 2023 TMI-2 Solutions, LLC - Response to Shpo Request for Additional Information for Er Project 2021PR03278.006, TMI-2 Decommissioning Project ML23167A4642023-07-0505 July 2023 Letter - TMI-2- Exemption 10 CFR Part 20 Append G Issuance ML23167A0312023-06-28028 June 2023 Acceptance Review and Schedule for the Request for Exemption from a Requirement from 10 CFR 20, Appendix G, Section Iii.E, EPID L-2023-LLE-0016 ML23171B0222023-06-19019 June 2023 (TMI-2) - Notification Pursuant to 10 CFR 72.140(d) Regarding Application of Previously Approved TMI-2 Quality Assurance Program to Independent Spent Fuel Storage Installation Activities 2024-09-09
[Table view] |
Text
10 CFR 50.55a TMI-10-101 October 8, 2010 U.S.Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Three Mile Island Nuclear Station, Unit 1 Renewed Facility Operating License No.DPR-50 NRC Docket No.50-289
Subject:
Supplemental Information Request-Fourth Inservice Inspection (lSI)Interval Relief Request 14R-02
References:
1)Letter from P.B.Cowan (Exelon Generation Company, LLC)to U.S.Nuclear Regulatory Commission,"Submittal of Relief Requests Associated with the Fourth Inservice Inspection (lSI)Interval," dated August 10, 2010 2)Letter from P.Bamford (U.S.Nuclear RegUlatory Commission) to M.J.Pacilio (Exelon Generation Company, LLC),"Three Mile Island Nuclear Station, Unit 1-Supplemental Information Needed for Acceptance of Requested Licensing Action RE: Request for Relief 14R-02, Fourth Inservice Inspection Interval, Alternate Risk Informed Selection and Examination Criteria for Pressure Retaining Welds (TAC NO.ME4519)," dated September 23,2010 In the Reference 1 letter, Exelon Generation Company, LLC submitted relief requests associated with the fourthInserviceInspection (lSI)interval for Three Mile Island Nuclear Station (TMI), Unit 1.The fourth interval of the TMI, Unit 1 lSI program complies with the 2004 Edition, no Addenda, of the American Society of Mechanical Engineers(ASME)Boiler and Pressure Vessel (B&PV)Code.In the Reference 2 letter, the U.S.Nuclear Regulatory Commission requested supplemental information concerning Relief Request 14R-02.Attached is our response to this supplemental request.There are no regulatory commitments in this letter.
Relief Requests Associated with the Fourth Inservice Inspection Interval October 8,2010 Page 2 If you have any questions concerning this letter, please contact Tom Loomis at (610)765-5510.Respectfully, Pamela B.Cow n Director-Licensing&Regulatory Affairs Exelon Generation Company, LLC
Attachment:
Supplemental Information Concerning Relief Request 14R-02 cc: Regional Administrator, Region I, USNRC D.M.Kern, USNRC Senior Resident Inspector, TMI P.J.Bamford, USNRC Project Manager, TMI ATTACHMENT Supplemental Information Concerning Relief Request 14R-02 Supplemental Information Request Fourth Inservice Inspection (lSI)Interval Relief Request 14R-02 Page 1 of 4 Supplemental Information Request: 1.Relief Request 14R-02 neither discusses the technical adequacy of its fire, seismic, and external events probabilistic risk assessment (PRA)nor provides a justification that these hazard groups are insignificant to the application'sinformed decision making, and therefore is not demonstrated to be consistent with Regulatory Guide (RG)1.200, Revision 2 and RG 1.174, Revision 1, both of which are referenced in the application.
Without this information, the NRC staff does not have sufficient information to begin its review.Relief Request 14R-02 must be modified to provide a discussion confirming that either RG 1.200, Revision 2, guidelines on the technical adequacy have been evaluated and satisfied, or provide ajustificationthat these hazard groups are insignificant to the application's risk-informed decision making consistent with RG 1.174, Revision 1, guidelines.
Response: In response to the request, a justification is provided that the fire, seismic and external events hazard groups are insignificant to the risk-informed inservice inspection (RI-ISI)evaluation and results.From Draft Regulatory Guide DG-1226 1 (Proposed Revision 2 of Regulatory Guide 1.174)[AS]:qualitative treatment of the missing modes and hazard groups may be sufficient when the licensee can demonstrate that those risk contributions would not affect the decision;that is, they do not alter the results of the comparison with the acceptance guidelines in Section 2.4 of this guide." Section 2.2 of EPRI 1021467, Nondestructive Evaluation:
Probabilistic Risk Assessment Technical Adequacy Guidance for Risk-Informed In-Service Inspection Programs[A4], provides justification for RI-ISI supporting analyses being based only on internal events PRAs.Fire, seismic and external hazard groups are determined to not affect the decision for the TMI, Unit 1 RI-ISI assessment.
Each of these hazard groups are discussed:
Internal Fire Events The following from EPRI 1021467[A4]applies to TMI, Unit 1: 1 Although draft, DG-1226 is applicable since it refers to Regulatory Guide 1.200, Revision 2 (the current revision that addresses PRA for external hazards).
Supplemental Information Request Fourth Inservice Inspection (lSI)Interval Relief Request 14R-02 Page 2 of 4"The potential contribution of piping failure to internal fire risk is insignificant as the failure probability of piping is insignificant compared to the failure probability of other systems, structures and components (SSCs), such as pumps, valves and power supplies.Fire events are also not likely to present significantly different challenges to the piping in the scope of this application.
Meeting defense in depth and safety margin principles provides additional assurance that this conclusion will remain valid.lSI is an integral part of defense in depth, and the RIISI process will maintain the basic intent of lSI (i.e., identifying and repairing flaws)and thus provide reasonable assurance of an ongoing substantive assessment of piping condition.
In addition, there are no changes to design basis events and thus Safety Margins are maintained.
" Seismic Events The following from EPRI 1021467[A4]applies to TMI, Unit 1: "Well engineered systems and structures (e.g., piping systems)are seismically rugged.IPEEE and other industry and NRC studies (e.g., EPRI TR-1000895, NUREG/CR-5646) have shown piping systems to have seismic fragility capacities greater than the screening values typically used in seismic assessment and are not considered likely to fail during a seismic event.lSI is not considered in establishing fragilities of such SSCs.Meeting defense in depth and safety margin principles provides assurance that this conclusion will remain valid.lSI is an integral part of defense in depth, and the RI lSI process will maintain the basic intent of lSI (i.e., identifying and repairing flaws)and thus provide reasonable assurance of an ongoing substantive assessment of piping condition.
In addition, there are no changes to design basis events and thus Safety Margins are maintained." The NRC has recently published documents that involve seismic capabilities of the reactor coolant system (DG-1216 and NUREG-1903), and the risk impact of updated seismic hazard estimates (GI-199).DG-1216[A2]and NUREG-1903
[A6]provided no indication that seismic events would have an impact on the RI-ISI process.GI-199[A3]was reviewed specifically for the seismic risk impact at TMI, Unit 1.The TMI, Unit 1 seismic risk is estimated to be lower, based on the 2008 USGS Seismic Hazard Curves, when compared to the risk calculated using the previous 1994 LLNL Seismic Hazard Curves[Appendix D of Reference A3].Finally, the TMI, Unit 1 IPEEE[A8]was reviewed;no seismic vulnerabilities were identified and seismic pipe failures were not important contributors.
Supplemental Information Request Fourth Inservice Inspection (lSI)Interval Relief Request 14R-02 Page 3 of 4 Other External Events The following from EPRI 1021467[A4]applies to TMI, Unit 1: "...the purpose of developing a RI-ISI program is to define an alternativeservice inspection strategy for piping systems.Other hazards (e.g.high wind, external floods)are not considered in the development of an in-service inspection program for piping.The reasons include: the structural ruggedness of the piping systems, location, as relevant systems are typically inside well engineered structure, and the consequence assessment for internal events already includes the consideration of spatial impacts.In addition, the substantial industry experience with plants implementing RI-ISI programs has not identified changes based upon insight from the evaluation of these other external hazards.The very small potential impact on the potential for piping failure of a RI lSI process, and the approaches to maintaining defense in depth and safety margins summarized above, provide confidence in this conclusion.
" The EPRI 1018427[A7]guidance on meeting Regulatory Guide 1.200, Revision 1 and Regulatory Guide 1.174 is sufficient for developing the RI-ISI program at TMI, Unit 1.The additional requirements imposed by Regulatory Guide 1.200, Revision 2 do not change the conclusions of the RHSI analysis at TMI because the quantification of the fire, seismic and other external events hazard groups has an insignificant impact on the RI-ISI analysis.Therefore, quantification of the fire, seismic and other external events hazard groups will not change the conclusions derived from the RI-ISI process.REFERENCES A 1.NRC Letter to M.J.Pacilio, Three Mile Island Nuclear Station, Unit 1Supplemental Information Needed for Acceptance of Requested Licensing Action RE: Request for Relief 14R-02, Fourth Inservice Inspection Interval, Alternate Risk Informed Selection and Examination Criteria for Pressure Retaining Welds (TAC No.ME4519), September 23,2010.A2.Draft Regulatory Guide DG-1216, Plant-Specific Applicability of Transition Break Size Specified in 10 CFR 50.46a, June 2010.A3.Generic Issue 199 (GI-199), Implications of Updated Probabilistic Seismic Hazard Estimates in Central and Eastern United States on Existing Plants, Safety/Risk Assessment, August 2010.A4.Nondestructive Evaluation:
Probabilistic Risk Assessment Technical Adequacy Guidance for Risk-Informed In-Service Inspection Programs.EPRI, Palo Alto, CA: 2010.1021467.
Supplemental Information Request Fourth Inservice Inspection (lSI)Interval Relief Request 14R-02 Page 4 of 4 AS.Draft Regulatory Guide DG-1226 (Proposed Revision 2 of Regulatory Guide 1.174, dated November 2002), An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis, August 2009.A6.NUREG-1903, Seismic Considerations For the Transition Break Size, February 2008.A7.Nondestructive Evaluation:
Probabilistic Risk Assessment Technical Adequacy Guidance for Risk-Informed In-Service Inspection Programs.EPRI, Palo Alto, CA: 2008.1018427.A8.TMI Unit 1 Individual Plant Examination for External Events Submittal Report, December 1994.