Three Mile Island Unit 1 Route 441 South, P.O. Box 480 Middletown, PA 17057 Telephone 717-948-8000 March. 19, 2018 TMl-18-016 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Three Mile Island Nuclear Station, Unit 1 Renewed Facility Operating License No. DPR-50 NRC Docket No. 50-289

Subject:

TMl-1 Steam Generator Inspection Report for End of Cycle 21 Refueling Outage Exelon Generation Company, LLC (Exelon) completed an examination of the tubing in the Three Mile Island Unit 1 (TMl-1) steam generators during Refueling Outage T1R22. TMl-1 Technical Specification 6.9.6 requires a report of the inspection results be submitted within 180 days after reactor coolant temperature exceeds 200°F. The attachment to this letter documents the results of the examinations.

No new regulatory commitments are established by this submittal. If any additional information I

is needed, please contact Michael Fitzwater at 717-948-8228.

Respectfully, c!),.)0 JM--J E.W. Callan, Jr.

Site Vice President, Three Mile Island Unit 1 Exelon Generation Co., LLC EWC/mdf Attachments cc: NRC Senior Resident lnspector-TMl-1 NRC Project Manager, NRR-TMl-1 NRC Administrator - Region I (w/o attachment)

R. R. Janati, Commonwealth of Pennsylvania S. L. Martin, PA Department of Environmental Protection, Bureau of Radiation Protection -

Nuclear Safety Division

THREE MILE ISLAND UNIT 1 STEAM GENERATOR TUBE INSPECTION REPORT END OF CYCLE 21 REFUELING OUTAGE OCTOBER 2017

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Contents:

Page 2 of 16 List of Figures:.............................................................................................................................................. 2 List of Tables:............................................................................................................................................... 2 Introduction............................................ :...................................................................................................... 3 Information Required by Technical Specification {T.S.) 6.9.6:.................................................................... 3 (TS 6.9.6.a.) The Scope of inspections performed on each Steam Generator:............................................. 3

{TS 6.9.6.b.) Degradation mechanisms found:....................................................... ~..................................... 5

{TS 6.9.6.c.) Nondestructive examination techniques utilized for each degradation mechanism:............... 6

{TS 6.9.6.d.) Location, orientation (iflinear), and measured sizes (if available) of service induced indications:.................................................................................................................................................... 6

{TS 6.9.6.e.) Number of tubes plugged during the inspection outage for each degradation mechanism:..... 9

{TS 6.9.6.f.) The number and percentage of tubes plugged to date, and the effective plugging percentage in each steam generator:................................................................................................................................ 9

{TS 6.9.6.g.) The results of condition monitoring, including the results of tube pulls and in-situ testing:.11 Summary:.................................................................................................................................................... 16 Exhibits:....................................................................................... :.............................................................. 16 List of Figures:

Figure 1: T1R22 - SG B - TSP Wear Support and Depth Distribution......................................................... 7 Figure 2: T1R22 - SG B - Tube-to-Tube {TTW) Wear Depth Distributions................................................ 9 Figure 3: TlR22 - SG B - Condition Monitoring Limit Plot for Broached TSP Wear (Bobbin)............... 12 Figure 4: T1R22 - SG B - Condition Monitoring Limit Plot for Broached TSP Wear (Array).................. 13 Figure 5: T1R22 - SG B - Condition Monitoring Limit Plot for Drilled TSP Wear (+PointTM ETSS 27901.1)...................................................................................................................................................... 14 Figure 6: T1R22 - SG B - Condition Monitoring Limit for T1R22 Tube-to-Tube Wear........................... 15 List of Tables:

Table 1: TMI-1 Replacement SG EFPY History.......................................................................................... 3 Table 2: TIR22 ECT Inspection Summary................................................................................................... 5 Table 3: TMI-1 Tube Plugging History...................................................................................................... 10

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Introduction Page 3 of 16 The TMI-1 replacement steam generators are AREVA Enhanced Once-Through Steam Generators, which are vertically mounted once-through heat exchangers with a counter-flow design. The EOTSGs have 15597 Alloy 690 thermally treated tubes, 0.625" nominal outer diameter (OD) with a 0.0368" wall thickness. The two steam generators are designated SG A and SG B. The tubes are supported by 15 tube support plates (TSPs) that are made of stainless steel, are 1.18" thick, and have trefoil broached holes. The uppermost TSP (15S) has 1740 drilled holes for the tubes at the outer periphery of the tube bundle.

During the period of9/18/2017 to 10/7/2017, TMI-1 was shut down for Refueling Outage T1R22.

While the unit was shut-down, Exelon performed examinations of the alloy 690TT tubing in the "B" Enhanced Once-Through Steam Generator (Henceforth referred to as "SG B").

The examinations were performed in accordance with Technical Specification (T.S.) 4.19 and 6.19.

The SGs, at the start of TlR22 (End of Cycle 21), have operated for a cumulative 7.266 Effective Full Power Years (EFPY) since their replacement in the fall of 2009 (T1Rl8). The EFPY history for the SGs is presented below in Table 1.

Table 1: TMI-1 Replacement SG EFPY History Cycle Effective Full Power Inspection Outage Years (EFPY) 18 1.720 TlRl 9 (Fall 2011) 19 1.876 TlR20 (Fall 2013) 20 1.890 T1R21 (Fall 2015) 21 1.780 T1R22 (Fall 2017)

Note: TMI-1 Replacement SGs were installed in TIRI8 (Fall 2009) and began operation in cycle 18.

Technical Specification 6.9.6 requires a report be submitted within 180 days after the average

. reactor coolant temperature exceeds 200°F following completion of an inspection performed in accordance with TS 6.19, Steam Generator (SG) Program.

The average reactor coolant temperature exceeded 200°F on 10/6/2017.

Information Required by Technical Specification (T.S.) 6.9.6:

The following Information is required to be submitted per T.S. 6.9.6. The applicable T.S.

paragraph is shown in parenthesis followed by the T.S. reporting requirement.

(TS 6.9.6.a.) The Scope of inspections performed on each Steam Generator:

The T1R22 examinations of SG B were the fourth in-service inspection following replacement of the steam generators during outage T1RI8. Per TMI Plant Technical Specifications, the TMI-1

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Page4 of 16 SGs, having operated 87.192 EFPM at T1R22, are in the first 144 effective full power month (EFPM) inspection period. During TlR22 visual and eddy current inspections were performed in the 'B' steam generator only.

Visual inspections were performed on: (1) 100% of installed tube plugs (Hot & Cold Leg) in SG B and (2) the channel head and tubesheet cladding (Hot & Cold Leg) in SG B. No conditions adverse to quality (i.e. degradation) were found during the Visual Inspections. All tube plugs were found to be in the as-installed configuration with no evidence of degradation or leakage.

During TIR22, all in-service tubes in each steam generator were examined over their entire length using the bobbin coil probe. A combination bobbin/array coil probe was used to examine a two-tube deep periphery tube population in the 'B' steam generator. The data from the array probe was evaluated for the detection of foreign objects in the span between the lower tubesheet and the first support plate. In addition, array probes and/or rotating probes were used to examine tubes with indications identified during the TIR22 bobbin coil examinations. This population of tubes was referred to as special interest (SI) tubes (See Table 2 for additional information). Table 2 illustrates the total scope for TIR22 eddy current examinations.

Steam Generator Tube Inspection Report EOG 21 Refueling Outage Page 5 of 16 Table 2: T1R22 ECT Inspection Summary

'/<~ s

':tondition 'o(Qegra(J.ation

'-fype.

  • . **.t:x:tent
  • ~~ope
    • Meclianis111:&sessed.

" Notes WearatTSPs Full Length Tube-to-Tube Wear Bobbin Lower Tube End {L TE) to 100% In-service tubes Dents/Dings Coil Upper Tube End (UTE)

Possible wear due to foreign objects (object not identified)

Lower Tubesheet {LTS) to 2 tube-deep periphery Foreign objects, Possible wear pt TSP (OlS) due to foreign objects Growth >=12%TW SGB Repeat Wear >=25%TW TSP Wear Only Special Interest (SI) for New wear >=20%TW SGA X-probe analysis - Tubes with new Inspection (Array) and prior TSP and TTW Deepest 6 new and deepest 6 Skipped repeat TTW Special Interest (SI) Line-Select TSP wear ( e.g.,

by-Line {LxL) Sizing

>=30% bobbin, TSP Wear multiple lands, flat, deep, etc)

RPC Special Interest (SI) Line-TSP wear at drilled support TSP Wear

(+Point')

by-Line {LxL) Sizing locations Notes:

Tube supports are identified as OlS (lower) to 15S (upper)

Full length examinations are from the lower tube end {L TE) to the upper tube end (UTE).

Array data for periphery tubes was evaluated in the span from the lower tube sheet {LTS) to the 1st TSP (OlS) for detection of foreign material or loose oarts.

(TS 6.9.6.b.) Degradation mechanisms found:

The eddy current examinations identified two active degradation mechanisms.

The first mechanism is tube-to-tube support plate (TSP) wear. The second mechanism is tube-to-tube wear (TTW). Both degradation mechanisms were identified previously during T1Rl9, TIR20, and TlR21 examinations.

Steam Generator Tube Inspection Report EOC 21 Refueling Outage (TS 6.9.6.c.) Nondestructive examination techniques utilized for each degradation mechanism:

Page 6 of 16 Multiple EPRI Examination Technique Specification Sheets (ETSSs) were used during TIR22.

Tube-to-Tube Support Plate (TSP) Wear:

ETSS 96043.1 (Rev. 2; Bobbin) was used for all detection and depth sizing of tube wear at the Broached TSP intersections.

ETSS 11956.3 (Rev. 2; Array) was used for special interest characterization of select flaws (See Table 2) and to size.flaws detected outside the bounds of the bobbin wear calibration.

ETSS 27901.1 (Rev. 1; +Point') was used for depth sizing of wear indications located at Drilled TSP intersections (This is RPC exam type listed in Table 2). Note: Only the 15th support plate periphery has Drilled TSP intersections Tube-to-Tube (TTW) Wear:

All TTW wear was detected and sized using bobbin ETSS 13091.1 Rev. 0.

(TS 6.9.6.d.) Location, orientation (if linear), and measured sizes (if available) of service induced indications:

The following information is provided to aid in understanding the location of indications within the SGs. The TMI-1 SGs have 15 tube support plates (TSPs), numbered OIS through 15S with 01 S being the bottom TSP. Exhibit 1 includes a listing of all service induced indications for "B" Steam Generator (SG B).

Tube-to-Tube Support Plate Wear:

The TSP wear is located primarily at or above the 7th TSP with the highest number of indications occurring at the 8th TSP. The deepest indications were primarily located at the 10th through 14th TSPs. The radial location of the TSP wear indications is more towards the periphery at the higher tube support plate locations.

In SG B, 6729 broached TSP wear indications were identified in the TIR22 inspection using the bobbin probe (see Exhibit 1). Most of these indications were located at or above the gth TSP. The deepest indications were primarily located at the 1 oth through the 14th TSPs. The deepest bobbin indication (59%TWD in tube 105-3) consisted of 2 flaws at 2 lands at the same tube support; one had a maximum depth of 44%TWD and a structural depth of 40.4%TWD and the other a maximum depth of25%TWD and structural depth of24.3%TWD as measured with the array coil. The second deepest bobbin indication (58%TWD in tube 5-14) also consisted of2 flaws at 2 lands at the same tube support; one had a maximum depth of 49% TWD and a structural depth of 40.9%TWD and the other a maximum depth of 18%TWD and structural depth of 15.8%TWD as measured with the array coil. Array sizing rather than bobbin was used because the qualification and calibration curve for the bobbin technique (ETSS 96043.1 Rev 2) is limited to

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Page 7 of 16 sizing wear at a single broached TSP land. Since there were indications at 2 different lands at that TSP elevation, bobbin sizing of the indications was not accurate and provided an overestimated indication depth. Therefore, the array coil was used for depth and length sizing these indications individually since the calibration curve for this technique is not affected by wear at multiple lands.

Additionally, SG B had 13 indications of Drilled TSP wear with the largest being 28% through wall, the same indication was sized at 25%TWD in T1R21. No tubes were plugged in SG B for Drilled TSP wear.

Figure 1 shows the distribution of broached TSP wear indications by depth.

2000 1800 11'1 C

1600 0

(II 1400 "t:I C:

1200 (II 1000

~

'o 800 QI 600

.0 E

s 400 z

200 0

1R22 Repeat 1R22 New 1R21 Repea1 1R21 New

<5 12 0

6 0

Distribution of Broached TSP Wear Indications by Depth TMl-1 SG B Sept-2017 1R22

  • 1R22 Repeat a 1R22 New

, 1R21 Repeat

~~ 1R21 New 5-9 10-14 15-19 20-24 30-34 35-39 40-44 45-49 50-54 55-59 1722 1705 764 302 134 62 17 3

2 0

1 "'

961 732 145 44 10 5

3 1

0 1"'

l "'

1080 1272 541 203 100 37 19 11 8

3 2

1220 705 154 36 11 3

3 0

0 0

0 Depth bin in Percent Throughwall Figure 1: T1R22 - SG B - TSP Wear Support and Depth Distribution

>=60 0

0 1

0

(* Note table lists 3 indications above 50% TWD initially sized by bobbin which were actually due to wear at 2 lands at the same support and therefore, had their actual depth overestimated by bobbin sizing)

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Tube-to-Tube Wear:

Page 8 of 16 During the TIR22 inspection, there were 288 indications of TTW reported in SG B. All of these indications were relatively shallow with the deepest measuring 19%TWD The majority of TTW indications are located between the 8th and the 9th TSPs, fourteen indications were located between the 7th and 8th TSPs, six other indications were located between the 4th and 5th TSPs, and one indication was between the 3rd and 4th TSPs.

Most of the tubes with TTW indications are located between 30"-45" from the center of the bundle. Generally speaking, there is a ring of tubes with indications.

The wear indications are essentially centered axially between the tube support plates and are typically in pairs with similar through wall depths. In some cases, there is a cluster of three or more affected tubes.

Tube-to-tube wear has been reported and sized by different techniques since its initial discovery.

Array probe, +Point', and bobbin probe have been used for sizing. Array and +Point' are capable of distinguishing multiple wear indications at the same axial location, but bobbin is not.

Because the bobbin technique tends to conservatively oversize tube-to-tube wear and this degradation mechanism has not challenged the TMI Operational Assessments, bobbin ETSS 13091.1 was developed and qualified for detection and sizing of all TTW beginning in Tl R2 l.

To allow depth comparisons for growth rate calculations, TIR20 bobbin data were re-analyzed for TTW and sized with ETSS 13091.1, with the results recorded into AREVA's FDMS database for comparison with future results. As such, counts of TTW wear indications may seem to decrease from TIR20 to TIR21 because the bobbin probe does not distinguish multiple wear indications at the same axial location.

Figure 2 shows the distribution of the TTW indications by percent through-wall.

Steam Generator Tube Inspection Report EOC 21 Refueling Outage 100 -- -

_§ 80

~

C i 60 +--------

'?5

.E E i 40 +--------,

O +----~

<=4 Sto 6 7to 8 9 to 10 11 to 12 13 to 14 Depth in PercentThroughwall 121 New I ndi::ations

  • Repeat lndic.itlons 15 lo 16 1710 18 1910 20 Figure 2: TlR22 - SG B -Tube-to-Tube (TTW) Wear Depth Distributions Page 9 of 16

>20 (TS 6.9.6.e.) Number of tubes plugged during the inspection outage for each degradation mechanism:

During the Tl R22 outage 52 tubes were plugged in SG B. Nine tubes were plugged based on indications at or above the Tech Spec limit of 40% TWD. 42 tubes were plugged to support the operational assessment plugging limits. One tube was plugged based on engineering judgment due to flaw morphology and proximity to nearby tubes being plugged for similar but deeper indications. In the course of plugging tubes based on flaw depths that met the screening criteria, numerous smaller flaws in the same tubes were also removed from service.

(TS 6.9.6.f.) The number and percentage of tubes plugged to date, and the effective plugging percentage in each steam generator:

There were no tubes plugged prior to T1R19. Table 3 shows the number of tubes plugged during each of the four steam generator inspections and the cumulative number of tubes plugged to date.

Steam Generator Tube Inspection Report EOG 21 Refueling Outage Page 10 of 16 PSI T1R19 T1R20 T1R21 T1R22 Total (Tubes)

Total(%)

Limit(%)

Limit (Tubes)

Table 3: TMl-1 Tube Plugging History 0

0 0

0 0

0 0

0 0

0 4

0 4

30 3

0 33 37 1

0 0

1 31 0

0 31 32 3

0 0

3 131 0

0 131 134 4

No inspection or plmH in~

52 0

0 52 52 4

0 8

244 0.051%

5.00%

779 of 15597 3

0 1.58%

5.00%

779 of 15597 247 255 0.82%

5.00%

1558 of 31194 Note: There are 15,597 tubes per Steam Generator.

There are no sleeves or repairs other than plugs with stabilizers installed in the steam generators.

The effective plugging percentage is the same as the actual plugged tube percentage. Following TIR22, the effective plugging percentage for SG B was 1.58%.

Steam Generator Tube Inspection Report EOG 21 Refueling Outage Page 11 of 16 (TS 6.9.6.g.) The results of condition monitoring, including the results of tube pulls and in-situ testing:

The observed degradation in the TMI-1 SG Bat the end of Cycle 21 (T1R22) was evaluated to determine if structural and leakage integrity requirements were met. The evaluation was consistent with NEI 97-06, and the applicable EPRI Guidelines. The observed degradation was shown not to present challenges to the structural integrity at the end of the operating interval or challenge required leakage integrity limits under postulated accident conditions.

No primary-to-secondary leakage occurred during Cycle 21. No tubes were pulled during the TlR22 steam generator inspections and no tubes required or were in-situ pressure tested in T1R22.

Tube-to-Tube Support Plate Wear:

A total of 6729 indications of tube wear at the broached tube support plates and 13 indications at drilled tube support plates were reported during the T1R22 inspection in SG B. The Condition Monitoring (CM) limit for TSP wear is a function of the depth, length, and shape (taper) of the wear profile.

Figure 3 and Figure 4 show the CM limit as a function of length and depth for the bobbin coil (ETSS 96043.1) and array coil (ETSS 11956.3) techniques, respectively. As shown in Figure 3, the CM limit for an indication with a structural length of 1.18" is -54% TWD when sized by the bobbin technique. Assuming a bounding flaw structural length equal to the entire thickness of the TSPs ( 1.18"), all indications except two met the structural integrity performance criteria by analysis based on bobbin sizing (ETSS 96043.1). The largest indications detected and sized by bobbin were 59%TWD in tube 105-3 at 14S and 58%TWD in tube 5-14 at l lS. Since the indications, as sized by bobbin, were not shown by analysis to meet the bobbin CM limit, the indications were line-by-line profiled using an array probe and ETSS 11956.3 to obtain a structurally equivalent length and depth, which was compared to the CM limit for the array technique. The tubes were each found to have two distinct wear indications on different lands of the same support plate, a condition for which the bobbin technique ETSS 96043.1 is not qualified to size. This is because the bobbin probe is incapable of distinguishing multiple indications at the same elevation and generally sums the depths of the indications, leading to an overestimation of the measured indication depth. ETSS 11956.3, using an array probe, is a qualified technique capable of resolving multiple indications at the same elevation and accurately sizing each indication at each land. As shown in Figure 4, using array probe data for the structural equivalent depth and length for the largest indication in each tube, tubes 105-3 and 5-14 also met structural integrity performance criteria by analysis. For reference, these values were 40.4 % TWD structural equivalent depth and 1.10 in. structural equivalent length for tube 105-3 and 40.9%TWD structural equivalent depth and 0.37 in. structural equivalent length for tube 5-14.

Other than tubes 105-3 and 5-14, the next deepest indication reported by bobbin was 51 % TWD (105-4 at 15S) Therefore, as a conservative measure this indication and numerous others in the upper range of the bobbin depth distribution were sized with array and evaluated for CM compliance. The array evaluation of the 51 %TWO indication initially sized by bobbin also

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Page 12 of 16 showed wear at 2 lands at the same TSP, measuring maximum depths of 34% and 32%TWD.

The 34% and 32%TWD values were obtained from the "line-by-line" sizing data. Therefore, this indication and all remaining TSP wear indications passed condition monitoring analytically with no need for in situ pressure testing.

TMI 1R22 SG B TSP Wear and CM Limit 100 90 80 70 0 ! 60

~

\\

\\

Ari assumed boundi~ length equal Two flaws with mul

  • land wear required to Iha support plate thickness must

\\

sizir,g by arra,y.

V be us.ed for bobbin exams

~

~

u

.s:;

50 Q.

~

~ 40 t--1 CM Limit at 1.1 a-= -54% TWO I

0 I

Iii u:

30

-- Bounding Bobbin n~w Let111lh -

CM limlt ElSS 96043.l 20

  • SG B Bobbin TSP Wear 10 0

0 0.2 0.4 0.6 0.8 1

1.2 1.4 1.6 1.8 2

Flaw length (In.)

Figure 3: T1R22 - SG B - Condition Monitoring Limit Plot for Broached TSP Wear (Bobbin)

It should also be noted that axial loading acting on the circumferential extent of the wear scar was also considered and is not limiting. Large Break Loss of Coolant Accident (LBLOCA) conditions were also considered during the CM evaluation. For LBLOCA events, the limiting load is the axial load created by the large tube-to-shell temperature differential that develops as the tubes cool faster than the shell. Structural integrity is satisfied with 100%TW wear indications with a total circumferential extent of I 07 degrees. Converting this to a PDA gives a PDA of 29.7%. Since none of the detected indications approached I 00% TWO, structural integrity under postulated LBLOCA conditions is satisfied.

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Page 13 of 16 TMI 1R22 SG B TSP Wear and CM Limit for Array Technique 11956.3 100 90 o

~ 80 e

.r; 70 C.

~ 60

\\

\\

~ "---

C

~

iv 50 C"

w 40 iv

~

30 u

2...

V'l

-J Tube 5-14 @11S I

! Tube 105-3 @14S I I

I "CM Limit ETSS 11956.3"

~ 20 RI

10 With Arrav 0

0 0.2 0.4 0.6 0.8 1

1.2 1.4 1.6 1.8 2

Flaw Structural Equivalent Length (in.)

Figure 4: TIR22 - SG B - Condition Monitoring Limit Plot for Broached TSP Wear (Array)

Thirteen tubes in SO B confirmed wear at the 1 SS drilled tube support plate locations. The deepest indication detected (tube 46-118) had a measured depth of28%TWD. As shown in Figure 5 this is well below the CM limit of 53%TWD for a 360 degree, uniform thinning indication with a length of 1.2", which are extremely conservative bounds. A structural profile was performed and a structural equivalent length of 0.3" and a structural equivalent depth of 18%TWD. This CM limit was determined using methodology defined by the EPRI Flaw Handbook Calculator.

The indications at the drilled TSP locations were also evaluated for structural integrity at LBLOCA conditions. Measured circumferential extents varied from 0.23 to 0.89 inches. The max Percent Degraded Area PDA of any drilled TSP indication was 10%, satisfying the 29.7 PDA criterion discussed above. Since none of the indications approached this depth, the LBLOCA criterion is also met for this mechanism.

Steam Generator Tube Inspection Report EOC 21 Refueling Outage 100.0 TMI 1R22 Drilled TSP Wear and CM Limit 0

~

I-e

.z:...

Q.

Qj 0

==

u.

90.0 80.0 70.0 60.0 50.0 40.0 -

30.0 -

20.0 -

10.0 0.0 0.000 cM Limit (ETSS 27901.1)

-- Bounding Length

  • 1R22 Drilled TSP Wear at Bounding Length I

I I

I I

0.200 0.400 0.600 0.800 1.000 Flaw Length (in.)

Page 14 of 16 0

j I

!f I

1.200 1.400 Figure 5: TIR22 - SG B - Condition Monitoring Limit Plot for Drilled TSP Wear (+PointTM ETSS 27901.1)

Tube-to-Tube Wear:

A total of288 indications of tube-to-tube wear (TTW) in 280 tubes were reported during the Tl R22 inspection. More indications were reported in TIR19 and TIR20 because TTW was evaluated with an array coil, which distinguishes multiple indications at the same axial location, while bobbin does not. Bobbin ETSS 13091. 1 was used for detection and sizing of TTW in Tl R21 and T 1 R22.

Bobbin data from Tl R20 were re-analyzed with ETSS 13091.1 and bobbin depths recorded in the TIR20 database to facilitate growth rate calculations for TTW. When re-analyzed with bobbin ETSS 13091.1 before Tl R2 l, SG B had 276 TTW indications.

Most (270) of the TTW indications identified in SG B TIR22 were located between the 8th and the 9th TSPs. 12 indications were located between the 7th and 8th TSPs, 6 indications were located between the 4th and 5th TSPs. The freespan length between the 8th - 9th and 4th - 5th TSPs is 37.82" between the edges of the two TSPs. The freespan length between the edges of the 7th - 8th TSPs is 38.82". Therefore, a bounding structural length of 39" for all TTW indications was used in the CM evaluation. The NOE lengths of these indications were not measured in TIR21 or T1R22 because of the slowly-changing nature ofTTW and the fact that the longest indication measured in Tl R20 was less than 8.2" long Therefore, using a structural length of 39" (i.e., assuming a completely flat wear shape along the entire TSP span) is extremely conservative. Using this bounding structural length, all indications of tube-to-tube wear met the structural integrity performance criteria with ample margin.

Figure 6 shows the CM limits as a function of length and depth for the bobbin coil TTW technique. As shown in the figures, the CM limit for an indication with a bounding structural

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Page 15 of 16 length of 39" is approximately 56%TWD. Since the deepest NDE depths were I 9%TWD in SO B tubes 22-63 and 46-84 (which were also 19% TWD in Tl R2 l ), all tube-to-tube wear indications passed condition monitoring analytically with no need for in situ pressure testing.

Screening for in situ pressure test candidates was performed in accordance with the EPRI In Situ Pressure Test Guidelines.

100 1R22 Tube-Tube Wear and CM Limit ETSS 13091.1 90 80 70

\\.

60 50 A conservative bounding length equal to the longest 40 span between TSPs is used.

30 20 -

  • 1R22 SG B Tube-Tube Wear

~

CM Limit 10 -

-- Bounding Length 0

0 5

10 15 20 25 30 35 40 45 50 Figure 6: T1R22 - SG B - Condition Monitoring Limit for T1R22 Tube-to-Tube Wear The indications of tube to tube wear were also evaluated for structural integrity at LBLOCA conditions. During the Tl R 19 inspection (2011 ), all the tube-to-tube wear indications were measured for circumferential extent. The Tl Rl 9 indications generally had circumferential extents of 50 to 70 degrees. During TI R20, there was one tube with four tube-to-tube wear indications in the same span. These indications had a combined circumferential extent of 147 degrees. Based on the allowable PDA of 29.7%, an allowable depth of 59.4%TWD is obtained for a postulated bounding 180-degree circumferential extent (29.7% x 360 I 180). Since none of the measured depths in Tl R22 approached this value, structural integrity under postulated LBLOCA conditions is satisfied.

Steam Generator Tube Inspection Report EOC 21 Refueling Outage Summary:

Page 16 of 16 This report meets the reporting requirements for Technical Specification 6.9.6. Exhibit 1 contained herein provides a complete list of service-induced indications for TMI-1 SG B Exhibits:

Exhibit 1 - SG B Indications Report - SG B, Broached TSP Wear Indications Sized by Bobbin Probe

~

J LJ Exhibit 1 TIR22 - SG B, Drilled Support TSP Wear Indications Sized by +Point Probe

~

Exhibit 1 attachment 2 Drilled - SG B, Tube-to-Tube Wear Indications Sized by Bobbin Probe

~~

l?:J Exhibit 1 TIR22

TMl-1 Steam Generator Tube Inspection Report (J'JR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Cpmm~nt 3

2 105 0.37 11 5

3 145 0.24 12 3

2 115

-0.73 9

5 4

105

-0.75 22 3

2 125

-0.73 37 5

4 125

-0.7 12 3

2 125 0.34 16 5

4 12S 0.39 11 3

2 13S

-0.76 23 5

5 10S

-0.68 6

3 2

13S 0.27 22 5

5 135

-0.75 8

3 35 125

-0.68 10 5

5 14S

-0.72 9

3 35

  • 135 0.29 26 5

6 10S * -0.68 9

3 35 145

-0.75 26 5

6 11S

-0.68 22 3

35 145 0.29 13 5

6 11S 0.41 15 3

36 125

-0.73 li 5

6 125

-0.68 15 3

36 135 0.36 11 5

6 125 0.39 26 3

36 145

-0.78 16 5

6 13S 0.27 6

4 1

075

-0.68 10 5

7 10S

-0.7 17 4

1 08S

-0.68 11 5

7 115

-0.7 10 4

1 105 0.39 12 5

7 115 0.4 9

4 1

12S

-0.73 10 5

7 125

-0.76 17 4

1 125 0.42 22 5

7 12S 0.38 25 4

1 13S

-0.81 11 5

8 10S

-0.7 18 4

1 13S 0.29 10 5

8 115

-0.68 19 4

2 11S

-0.78 15 5

8 115 0.39 12 4

2 125

-0.75 10 5

8 125 0.39 23 4

3 105

-0.73 25 5

9 105

-0.77 6

4 3

115

-0.75 14 5

9 11S

-0.7 20 4

3 12S

-0.71 18 5

9 115 0.38 14 4

3 135

-0.76 19 5

9 125

-0.75 14 4

3 135 0.22 15 5

9 12S 0.31 15 4

3 145 0.24 12 5

10 105

-0.74 11 4

37 125 0.32 10 5

10 11S

-0.7 28 4

38 105 0.4 8

5 10 115 0.39 12 4

38 145

-0.83 10 5

10 12S

-0.7 14 4

38 145 0.29 9

5 10 125 0.34 16 5

1 10S 0.39 8

5 11 105

-0.72 16 5

1 14S

-0.75 10 5

11.

11S

-0.68 39 5

1 145 0.22 22 5

11 115 0.38 13 5

2 105

-0.75 21 5

11 125

-0.72 25 5

2 105 0.34 12 5

11 125 0.34 19 5

2 135

-0.76 14 5

12 105

-0.74 9

5 2

135 0.27 10 5

12 11S

-0.71 32 5

3 145

-0.75 16 5

12 115 0.35 18 Page 1 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 5

12 125 0.35 14 5

20 155 0.23 7

5 13 105

-0.72 13 5

21 115

-0.7 36 5

13 115

-0.71 22 5

21 115 0.34 12 5

13 115 0.37 24 5

21 125

-0.75 9

5 13 125

-0.72 9

5 21 125 0.3 15 5

13 125 0.33 10 5

21 155

-0.79 8

5 14 115

-0.7 58 Array 49% Max 5

21 155 0.18 9

5 14 115 0.36 15 5

23 105

-0.83 12 5

14 125

-0.7 17 5

23 115

-0.76 12 5

14 125 0.32 17 5

23 125

-0.74 15 5

14 145

-0.83 8

5 23 125 0.29 22 5

14 145 0.2 13 5

23 135 0.29 9

5 15 115

-0.7 48 5

23 145 0.22 15 5

15 11S 0.34 26 5

23 15S

-0.83 9

5 15 125

-0.74 7

5 24 12S

-0.72 14 5

15 12S 0.32 19 5

24 12S 0.27 17 5

16 115

-0.71 39 5

25 11S

-0.76 9

5 16 12S

-0.67 13 5

25 12S

-0.72 8

5 16 12S 0.28 13 5

25 12S 0.29 20 5

17 11S

-0.7 30 5

25 13S 0.29 7

5 17 115 0.34 8

5 25 14S 0.23 12 5

17 125

-0.72 8

5 26 11S

-0.72 11 5

17 12S 0.29 15 5

26 115 0.34 7

5 17 13S 0.25 8

5 26 12S

-0.7 29 5

18 11S

-0.72 22 5

26 12S 0.3 22 5

18 11S 0.32 13 5

26 13S 0.25 9

5 18 12S 0.32 11 5

26 15S

-0.84 8

5 19 11S

-0.74 34 5

  • 27 11S

-0.7 9

5 19 11S 0.36 19 5

27 12S

-0.77 26 5

19 12S 0.32 20 5

27 125 0.3 11 5

19 135

-0.68 10 5

27 13S 0.25 7

5 19 13S 0.25 13 5

28 10S

-0.74 12 5

19 14S

-0.85 15 5

28 11S

-0.76 10 5

19 14S 0.23 15 5

28 115 0.32 8

5 19 15S

-0.86 9

5 28 12S

-0.79 12 5

19 15S 0.23 11 5

28 12S 0.32 13 5

20 11S

-0.69 26 5

28 135 0.29 13 5

20 11S 0.36 11 5

29 11S

-0.7 19 5

20 12S 0.32 14 5

29 11S 0.36 24 5

20 15S

-0.86 8

5 29 125

-0.72 13 Page 2 of 85

TMI-1 Steam Generator Tube Inspection Report (Tl R22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 5

29 12S 0.32 14 5

39 10S 0.41 13 5

31 10S

-0.72 16 5

39 14S 0.32 11 5

31 11S 0.29 10 5

40 10S

-0.71 10 5

31 12S

-0.7 10 5

40 14S

-0.78 27 5

31 12S 0.34 15 5

41 10S 0.34 17 5

31 13S 0.32 9

5 41 12S 0.29 13 5

31 14S

-0.86 14 5

41 14S

-0.76 21 5

31 14S 0.25 10 5

41 14S 0.27 10 5

32 11S 0.29 15 5

42 13S 0.34 17 5

32 12S

-0.72 8

5 42 14S 0.29 30 5

32 12S 0.32 21 6

1 11S

-0.71 8

5 32 13S 0.29 10 6

1 13S 0

19 5

32 14S

-0.81 15 6

1 14S

-0.75 14 5

33 11S

-0.7 6

6 1

14S 0.17 21 5

33 11S 0.34 11 6

3 10S

-0.73 7

5 33 12S

-0.7 14 6

3 11S

-0.71 16 5

33 12S 0.34 19 6

3 14S

-0.78 15 5

33 13S 0.29 10 6

3 14S 0.17 14 5

33 14S

-0.81 14 6

4 10S

-0.75 9

5 34 11S

-0.68 22 6

5 10S

-0.75 25 5

34 11S 0.35 25 6

7 10S

-0.7 29 5

34 12S

-0.68 16 6

8 10S

-0.67 24 5

34 12S 0.35 24 6

9 10S

-0.66 23 5

34 13S 0.31 11 6

9 12S 0.32 12 5

34 14S

-0.84 15 6

9 14S

-0.84 7

5 35 11S

-0.67 18 6

10 10S

-0.7 12 5

35 11S 0.43 17 6

10 11S 0.3 6

5 35 12S

-0.67 11 6

10 12S 0.39 11 5

35 12S 0.39 15 6

11 10S

-0.7 20 5

35 14S

-0.77 14 6

11 11S

-0.7 22 5

36 11S

-0.7 20 6

11 11S 0.39 13 5

36 11S 0.41 17 6

11 14S

-0.86 11 5

36 12S

-0.68 12 6

12 10S

-0.68 13 5

36 12S 0.36 23 6

12 125 0.36 17 5

36 145

-0.77 10 6

12 135

-0.77 9

5

37. 105

-0.67 12 6

12 145

-0.84 19 5

37 125

-0.7 12 6

12 145 0.16 11 5

37 145

-0.75 14 6

13 10S

-0.72 11 5

38 105

-0.65 11 6

13 115

-0.68 37 5

38 10S 0.38 15 6

13 115 0.36 11 Page3 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment I, Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 6

13 12S

-0.7 11 6

23 10S

-0.72 8

6 13 12S 0.34 16 6

23 10S 0.36 10 6

13 13S

-0.86 16 6

23 11S 0.32 10 6

13 13S 0.2 12 6

23 12S 0.32 11 6

13 14S

-0.84 10 6

23 14S

-0.81 12 6

13 14S 0.16 11 6

23 15S

-0.9 7

6 13 15S

-0.9 11 6

24 11S 0.34 14 6

14 11S

-0.68 37 6

24 12S 0.23 14 6

14 12S

-0.75 16 6

24 14S

-0.81 12 6

14 12S 0.27 17 6

24 15S

-0.9 13 6

14 13S

-0.75 11 6

25 10S

-0.76 19 6

14 13S 0.23 7

6 25 11S 0.32 19 6

14 14S 0.18 9

6 25 12S 0.23 20 6

15 10S

-0.77 6

6 25 13S 0.22 10 6

15 11S

-0.72 31 6

25 14S 0.13 10 6

15 12S 0.36 15 6

26 11S

-0.67 8

6 16 11S

-0.72 23 6

26 11S 0.34 18 6

16 12S

-0.7 16 6

26 12S 0.29 14 6

16 12S 0.34 11 6

26 14S

-0.85 10 6

17 10S

-0.77 13 6

26 15S 0.11 7

6 17 12S

-0.79 16 6

27 11S 0.36 18 6

17 14S 0.2 9

  • 6 27 12S 0.29 13 6

18 10S

-0.72 24 6

27 14S 0.16 6

6 18 11S

-0.7 19 6

28 10S

-0.71 9

6 18 12S 0.36 9

6 28 11S

-0.72 14 6

19 10S

-0.72 19 6

28 11S 0.34 18 6

19 11S

-0.7 18 6

29 11S

-0.69 14 6

19 12S 0.32 13 6

29 11S 0.36 19 6

19 14S

-0.88 9

6 29 12S 0.34 8

6 20 10S

-0.72 19 6

29 13S 0.27 8

6 20 11S

-0.7 20 6

29 14S

-0.91 8

6 20 13S, -0.88 9

6 30 11S

-0.71 18 6

21 10S

-0.74 15 6

30 11S 0.38 18 6

21 11S 0.29 6

6 30 12S 0.32 15 6

21 12S 0.3 12 6

30 14S

-0.87 11 6

21 14S

-0.88 6

6 31 11S

-0.69 20 6

22 10S

-0.74 7

6 31 11S 0.38 20 6

22 11S

-0.72 14 6

31 12S 0.25 16 6

22 13S

-0.84 12 6

31 13S 0.2 6

6 22 15S

-0.95 9

6 31 14S

-0.81 8

Page 4 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 6

31 15S

-0.81 6

7 2

14S

-0.78 14 6

32 11S

-0.65 19 7

2 14S 0.24 15 6

32 11S 0.34 31 7

4 13S

-0.78 14 6

32 14S 0.18 14 7

4 14S

-0.9 6

6 33 11S

-0.71 17 7

4 14S 0.2 14 6

33 11S 0.31 33 7

5 10S

-0.7 11 6

33 12S 0.34 23 7

5 12S 0.27 9

6 33 14S 0.27 9

7 6

10S 0.41 9

6 34 11S

-0.67 13 7

6 14S 0.21 15 6

34 11S 0.38 29 7

8 12S 0.27 6

6 35 11S

-0.69 18 7

8 14S 0.2 13 6

35 11S 0.38 30 7

9 10S

-0.71 13 6

35 12S

-0.74 9

7 10 14S

-0.81 8

6 35 12S 0.29 20 7

11 10S

-0.71 16 6

35 13S 0.29 7

7 11 10S 0.36 12 6

35 15S

-0.85 11 7

11 11S

-0.75 21 6

37 12S

-0.7 7

7 11 11S 0.32 16 6

37 14S

-0.79 13 7

11 12S 0.39 8

6 38 14S

-0.75 13 7

11 14S 0.25 9

6 39 10S 0.43 9

7 11 15S 0.23 7

6 39 14S

-0.79 11 7

12 10S

-0.68 15 6

40 10S 0.38 11 7

12 10S 0.37 6

6 41 14S

-0.81 11 7

12 13S

-0.87 12 6

42 10S

-0.69 11 7

12 14S

-0.86 8

6 43 10S

-0.71 20 7

13 10S

-0.7 14 6

44 10S 0.39 22 7

13 10S 0.34 11 6

45 10S 0.34 26 7

13 11S

-0.7 12 6

45 14S

-0.73 25 7

13 12S

-0.75 10 6

45 14S 0.32 17 7

13 12S 0.27 13 6

46 10S 0.39 16 7

13 15S

-0.86 10 6

46 14S

-0.78 26 7

14 11S

-0.75 21 6

46 14S 0.29 17 7

14 11S 0.34 13 6

47 13S 0.32 11 7

14 12S 0.34 15 7

1 11S

-0.71 14 7

14 15S

-0.86 19 7

1 13S

-0.73 12 7

14 15S 0.18 11 7

1 13S 0.17 11 7

15 10S 0.34 10 7

2 07S 0.46 11 7

15 11S

-0.73 16 7

2 11S

-0.73 17 7

15 11S 0.34 20 7

2 13S

-0.78 16 7

15 12S 0.32 16 7

2 13S 0.22 10 7

15 14S

-0.79 10 Page 5 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe 1 Outage T1R22 Location Location Row Tube TSP Offset TW

.comment Row Tube TSP Offset TW Comment 7

16 11S

-0.75 15 7

27 15S

-0.84 14 7

16 11S 0.32 19 7

28 11S 0.36 18 7

16 12S 0.32 9

7 28 15S

-0.84 11 7

17 11S

-0.73 13 7

29 11S 0.34 17 7

17 11S 0.36 12 7

30 11S

-0.75 7

7 17 12S 0.32 11 7

30 11S 0.38 10 7

17 14S

-0.91 6

7 31 10S

-0.72 9

7 17 14S 0.23 9

7 31 11S

-0.7 11 7

17 15S

-0.77 19 7

31 11S 0.34 12 7

17 15S 0.18 12 7

31 15S

-0.83 6

7 18 10S

-0.72 16 7

32 11S

-0.72 7

7 18 11S

-0.7 14 7

32 11S 0.36 18 7

18 12S 0.3 9

7 32 14S

-0.79 9

7 19 10S

-0.7 16 7

33 10S

-0.69 11 7

19 11S

-0.72 12 7

33 11S 0.36 25 7

19 11S 0.36 11 7

33 14S

-0.79 13 7

20 10S

-0.68 25 7

33 15S 0.18 6

7 20 11S

-0.75 11 7

34 10S

-0.67 13 7

20 12S 0.27 8

7 34 11S

-0.67 13 7

21 10S

-0.7 25 7

34 11S 0.38 32 7

21 11S

-0.75 14 7

34 12S 0.34 14 7

21 11S 0.32 7

7 34 14S

-0.81 11 7

22 10S

-0.68 14 7

35 10S

-0.78 7

7 22 11S

-0.75 9

7 35 11S

-0.7 15 7

23 10S

-0.68 10 7

35 11S 0.36 21 7

23 11S

-0.7 12 7

35 12S 0.34 16 7

23 11S 0.34 8

7 35 14S 0.11 10 7

24 10S

-0.68 12 7

38 11S 0.25 7

7 24 11S

-0.7 16 7

39 11S 0.25 12 7

24 11S 0.32 18 7

39 14S

-0.83 16 7

24 14S

-0.77 14 7

40 10S 0.36 14 7

25 10S

-0.68 12 7

40 14S

-0.9 11 7

25 11S 0.29 11 7

41 10S 0.38 16 7

25 14S 0.25 8

7 41 14S 0.2 13 7

26 10S

-0.72 13 7

42 10S 0.4 10 7

26 11S

-0.72 11 7

42 14S

-0.79 11 7

26 11S 0.34 16 7

43 10S 0.42 19 7

26 15S

-0.77 13 7

43 14S

-0.79 11 7

27 11S

-0.77 7

7 43 14S 0.27 11 7

27 11S 0.32 14 7

44 10S 0.43 10 Page 6 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row. Tube TSP Offset TW Comment 7

44 135 0.32 8

8 13 105

-0.7 8

7 45 105 0.43 12 8

13 115 0.36 8

7 45 145

-0.85 7

8 14 145

-0.75 9

7 46 135

-0.73 11 8

14 145 0.25 7

7 46 145

-0.78 19 8

15 105

-0.61 8

7 46 145 0.27 21 8

15 115 0.36 15 7

47 145

-0.78 16 8

16 10S

-0.7 8

7 47 145 0.29 12 8

16 115

-0.73 16 7

48 105 0.39 24 8

16 115 0.32 23 7

48 145

-0.88 17 8

17 105

-0.7 11 7

48 145 0.24 32 8

17 115 0.39 11 7

so 135 0.37 12 8

17 155

-0.86 9

7 so 145

-0.78 20 8

18 145

-0.75 9

8 1

115

-0.73 8

8 19 105

-0.7 8

8 1

125

-0.71 19 8

20 105 0.41 8

8 1

125 0.39 23 8

20 115 0.3 16 8

1 135

-0.76 13 8

20 145 0.2 9

8 1

135 0.27 12 8

20 155 0.23 7

8 2

075

-0.66 9

8 21 105

-0.68 23 8

2 075 0.49 12 8

21 115 0.34 8

8 2

115

-0.78 9

8 22 105

-0.68 24 8

2 135

-0.78 15 8

22 115 0.36 12 8

2 135 0.29 10 8

22 155

-0.88 7

8 2

145

-0.78 29 8

23 105

-0.68 15 8

2 145 0.17 31 8

24 145 0.25 14 8

3 105 0.39 9

8 25 105

-0.7 13 8

3 115

-0.78 19 8

25 115 0.34 17 8

3 135

-0.24 29 8

25 145

-0.79 12 8

3 145

-0.8 32 8

26 115 0.32 14 8

3 145 0.2 28 8

27 155

-0.81 11 8

4 115

-0.78 6

8 28 105

-0.72 16 8

4 145

-0.75 20 8

28 115 0.32 18 8

4 145 0.17 26 8

29 155 0.18 7

8 5

145

-0.78 13 8

30 115 0.34 16 8

8 105

-0.72 23 8

30 155

-0.84 13 8

10 105

-0.73 19 8

31 115 0.34 18 8

10 145

-0.86 16 8

31 155 0.16 9

8 11 105

-0.68 12 8

33 115 0.38 13 8

11 115 0.29 11 8

33 155

-0.83 11 8

12 105

-0.68 11 8

34 115 0.36 12 Page 7 of 85

TMl-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 8

35 115 0.38 13 9

1 105 0.37 12 8

36 115 0.34 25 9

1 135

-0.78 12 8

37 115 0.36 20 9

2 125

-0.68 9

8 37 155

-0.81 16 9

2 125 0.44 8

8 38 095 0.42 7

9 2

135

-0.76 11 8

38 115

-0.67 9

9 3

075

-0.68 9

8 38 115 0.36 20 9

3 105

-0.76 11 8

39 095 0.4 7

9 3

145 0.2 15 8

39 115 0.41 9

9 4

145

-0.73 8

8 39 155

-0.72 8

9 5

105

-0.73 18 8

41 145

-0.85 8

9 5

145 0

36 8

42 145

-0.72 11 9

6 145

-0.78 10 8

43 105 0.38 12 9

8 105

-0.73 12 8

44 145

-0.83 13 9

8 145

-0.84 14 8

45 105 0.38 15 9

8 145 0.25 7

8 45 145

-0.31 26 9

9 105 0.38 10 8

45 155 0.25

.18 9

9 145

-0.86 8

\\

8 46 145

-0.79 22 9

9 155 0.23 7

8 46 145 0.27 10 9

11 105

-0.74 15 8

46 155 0.32 16 9

11 145

-0.86 6

8 48 105 0.42 10 9

13 105

-0.69 30 8

48 125

-0.82 8

9 13 115 0.29 12 8

48 135 0.29 15 9

14 105

-0.68 28 8

48 145

-0.27 36 9

14 115 0.36 27 8

49 145

-0.83 23 9

15 105

-0.68 18 8

49 145 0.29 17 9

15 115

-0.77 13 8

50 105 0.41 16 9

15 115 0.34 29 8

so 145

-0.85 13 9

16 105

-0.73 8

8 so 145 0.24 29 9

16 115

-0.73 12 8

51 105 0.37 22 9

16 115 0.36 26 8

51 135 0.32 23 9

17 105

-0.68 8

8 51 145

-0.78 29 9

18 105

-0.7 11 8

51 145 0.27 29 9

18 115

-0.75 18 8

53 135 0.29 27 9

18 115 0.34 22 8

53 145

-0.8 22 9

19 115 0.36 11 8

53 145 0.27 29 9

20 105

-0.75 7

8 54 135

-0.73 11 9

20 115 0.36 9

8 54 135 0.29 27 9

21 105

-0.73 12 8

54 145

-0.8 22 9

21 115

-0.75 10 8

54 145 0.17 16 9

21 115 0.34 21 Page 8 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 9

22 11S

-0.81 8

9 54 14S

-0.86 12 9

22 11S 0.36 17 9

54 14S 0.34 11 9

22 15S 0.18 9

9 55 12S

-0.73 8

9 23 10S

-0.81 6

9 55 12S 0.34 10 9

23 10S 0.32 9

9 55 13S 0.32 19 9

23 11S 0.34 17 9

55 14S

-0.22 26 9

24 11S 0.34 15 9

56 10S 0.29 24 9

25 10S

-0.7 10 9

56 13S

-0.78 12 9

25 11S 0.32 15 9

56 13S 0.29 20 9

26 10S

-0.68 11 9

56 14S

-0.76 19 9

26 11S 0.34 12 9

56 14S 0.27 33 9

27 10S

-0.72 8

9 57 10S 0.32 28 9

27 11S 0.32 20 9

57 13S

-0.78 9

9 28 11S 0.27 18 9

57 13S 0.32 11 9

30 12S 0.27 7

9 57 14S

-0.88 21 9

31 10S

-0.72 8

9 57 14S 0.24 19 9

31 11S 0.32 14 9

58 10S 0.34 13 9

32 11S 0.34 10 9

58 14S

-0.81 17 9

32 14S 0.25 8

9 58 14S 0.27 18 9

33 11S 0.36 11 9

59 10S 0.39 17 9

33 14S

-0.81 9

9 59 13S 0.34 11 9

34 11S 0.36 16 9

59 14S

-0.8 16 9

35 11S 0.36 12 9

59 14S 0.22 10 9

35 12S 0.32 7

9 60 13S 0.34 14 9

36 11S 0.36 16 9

60 14S 0.17 13 9

36 15S 0.18 10 10 1

10S 0.34 19 9

37 11S 0.38 7

10 2

14S

-0.8 14 9

38 10S

-0.72 7

10 3

10S

-0.71 20 9

38 11S 0.38 17 10 3

14S

-0.8 13 9

39 11S 0.38 12 10 4

14S

-0.78 18 9

40 11S 0.41 11 10 5

10S

-0.75 19 9

49 10S 0.4 13 10 5

14S

-0.75 21 9

so 10S 0.43 12 10 6

14S

-0.75 20 9

51 10S 0.42 12 10 7

10S

-0.77 18 9

51 15S 0.29 15 10 7

14S

-0.82 10 9

52 10S 0.4 13 10 10 15S 0.23 14 9

52 15S 0.29 22 10 11 15S 0.14 16 9

53 13S 0.31 12 10 12 14S

-0.88 7

9 53 14S

-0.83 22 10 15 10S

-0.73 16 9

53 14S 0.31 13 10 15 11S 0.39 20 Page 9 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 10 23 105

-0.65 13 11 1

125

-0.68 8

10 25 115 0.36 9

11 2

105

-0.78 12 10 34 105

-0.72 21 11 3

125

-0.73 19 10 34 115 0.34 17 11 5

105

-0.7 9

10 35 115 0.38 8

11 6

105

-0.73 12 10 36 115 0.34 14 11 6

115

-0.82 8

10 37 115 0.35 8

11 6

145

-0.79 12 10 38 115 0.36 12 11 6

145 0.14 11 10 39 115 0.35 14 11 7

105

-0.7 12 10 40 115 0.36 10 11 8

105

-0.71 14 10 41 115 0.35 11 11 9

105

-0.75 17 10 52 105 0.42 11 11 9

145

-0.78 10 10 53 105 0.38 13 11 9

155

-0.83 14 10 54 155 0.29 13 11 9

155 0.18 29 10 55 135 0.29 7

11 10 155

-0.89 6

10 55 145

-0.83 10 11 10 155 0.16 21 10 56 145

-0.77 21 11 11 115 0.27 16 10 57 135

-0.7 12 11 11 155 0.18 13 10 57 135 0.25 16 11 12 145

-0.79 15 10 57 145

-0.81 16 11 12 145 0.21 7

10 57 145 0.27 25 11 12 155 0.18 17 10 58 135 0.36 15 11 14 115

-0.7 10 10 58 145 0.27 11 11 14 115 0.34 11 10 59 145

-0.84 16 11 14 125 0.32 8

10 59 145 0.29 29 11 14 155

-0.78 9

10 60 105 0.34 15 11 15 105

-0.74 10 10 60 135 0.27 21 11 15 145

-0.84 9

10 60 145

-0.75 19 11 16 105

-0.68 24 10 60 145 0.32 18 11 16 115

-0.79 9

10 62 115

-0.68 12 11 16 115 0.36 20 10 62 115 0.34 11 11 16 155 0.14 11 10 62 135 0.34 14 11 17 105

-0.68 12 10 63 135

-0.73 19 11 17 115 0.34 19 10 64 125

-0.66 9

11 18 105

-0.7 15 10 64 125 0.39 11 11 18 115

-0.76 17 10 64 135 0.29 22 11 18 115 0.37 25 10 65 125

-0.68 32 11 18 125 0.29 10 10 65 125 0.39 20 11 18 155 0.23 12 10 65 135

-0.78 19 11 19 105

-0.7 11 10 65 135 0.34 27 11 19 105 0.36 11 Page 10 of 85

-~~--

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 11 19 11S

-0.77 29 11 66 12S

-0.71 19 11 19 11S 0.34 17 11 66 12S 0.39 39 11 19 15S

-0.86 12 11 66 13S 0.29 21 11 19 15S 0.16 11 11 66 14S 0.2 14 11 21 10S 0.36 10 11 67 12S

-0.71 11 11 21 14S

-0.9 9

11 67 13S 0.34 17 11 21 15S

-0.86 11 11 68 10S 0.37 14 11 23 11S 0.34 17 11 68 11S

-0.68 8

11 23 14S

-0.84 9

11 68 11S 0.49 12 11 23 15S 0.18 9

11 68 12S

-0.71 26 11 24 11S 0.34 9

11 68 12S 0.42 22 11 28 11S 0.36 9

11 68 13S

-0.76 10 11 29 11S 0.31 13 11 68 13S 0.34 26 11 30 11S 0.36 13 12 1

12S

-0.68 10 11 32 11S 0.31 8

12 2

14S

-0.78 10 11 34 11S 0.34 8

12 2

14S 0.17 17 11 42 11S 0.38 12 12 3

14S 0.2 11 11 55 10S

-0.72 8

12 5

095 0.34 8

11 57 14S

-0.84 15 12 5

10S

-0.75 9

11 57 14S 0.29 9

12 5

12S 0.23 8

11 58 11S 0.31 23 12 7

10S

-0.7 22 11 58 13S 0.27 9

12 7

11S

-0.82 8

11 58 14S

-0.81 13 12 7

11S 0.3 10 11 58 15S

-0.76 10 12 8

11S

-0.83 7

11 58 15S 0.32 17 12 8

14S 0.21 17 11 59 14S

-0.77 11 12 9

14S

-0.93 7

11 60 14S

-0.79 19 12 9

15S 0.18 21 11 60 15S

-0.81 19 12 10 14S 0.21 23 11 61 10S 0.43 17 12 11 10S

-0.7 11 11 61 14S

-0.75 17 12 11 11S 0.32 9

11 61 14S 0.29 17 12 13 10S

-0.75 11 11 62 14S

-0.79 11 12 13 11S

-0.82 6

11 62 14S 0.29 27 12 14 10S

-0.79 8

11 63 14S 0.32 8

12 15 11S

-0.79 17 11 64 10S

-0.73 10 12 15 11S 0.36 13 11 64 14S

-0.9 15 12 16 09S

-0.7 22 11 64 14S 0.24 11 12 16 09S 0.34 25 11 66 10S

-0.73 8

12 16 10S

-0.68 20 11 66 11S

-0.68 24 12 16 11S

-0.81 18 11 66 11S 0.34 24 12 16 11S 0.3 17 Page 11 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 12 17 10S

-0.73 12 13 13 10S

-0.64 13 12 17 11S

-0.73 9

13 13 11S

-0.79 7

12 17 11S 0.34 28 13 13 11S 0.34 10 12 17 12S 0.3 8

13 13 14S

-0.86 9

12 17 15S 0.18 11 13 14 09S 0.38 8

12 18 11S 0.34 17 13 14 10S

-0.74 10 12 19 11S 0.34 13 13 14 11S 0.36 15 12 24 11S

-0.74 6

13 15 09S 0.39 7

12 24 11S 0.29 10 13 15 10S

-0.75 6

12 44 09S

-0.73 9

13 16 10S

-0.74 11 12 62 14S

-0.83 13 13 16 11S 0.33 13 12 62 14S 0.34 10 13 16 14S

-0.9 7

12 63 14S

-0.81 7

13 16 15S 0.2 12 12 63 14S 0.29 12 13 18 11S 0.34 18 12 67 11S

-0.63 41 13 18 14S

-0.88 15 12 67 12S

-0.68 22 13 19 09S 0.39 9

12 67 13S

-0.76 13 13 19 11S 0.34 8

12 68 11S

-0.71 11 13 19 12S 0.3 8

12 68 12S

-0.71 31 13 21 11S 0.36 11 12 68 13S

-0.73 15 13 22 09S 0.43 7

12 69 10S 0.37 21 13 60 12S

-0.75 8

12 69 11S

-0.73 10 13 60 12S 0.36 8

12 69 11S 0.39 11 13 62 11S 0.38 11 12 69 12S

-0.76 16 13 66 10S 0.43 7

12 69 12S 0.39 19 13 67 14S

-0.75 13 12 69 13S 0.39 15 13 67 14S 0.32 17 13 2

14S 0.22 12 13 68 10S 0.38 9

13 3

12S

-0.71 10 13 68 14S 0.32 9

13 5

10S

-0.72 20 13 71 12S

-0.71 28 13 5

12S 0.39 16 13 73 11S

-0.73 15 13 6

10S

-0.72 16 13 73 12S

-0.73 31 13 7

10S

-0.7 31 13 73 12S 0.39 28 13 7

14S

-0.79 9

13 73 13S

-0.73 29 13 7

14S 0.16 14 13 73 13S 0.32 24 13 8

10S

-0.7 26 13 74 09S

-0.68 9

13 10 14S

-0.88 9

13 74 10S 0.34 28 13 10 15S 0.16 19 13 74 11S

-0.71 12 13 11 15S 0.16 15 13 74 12S

-0.71 15 13 12 09S 0.38 9

13 74 12S 0.39 22 13 12 11S 0.27 6

13 74 13S 0.32 17 Page 12 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 13 74 145

-0.73 12 14 35 155 0.11 8

14 2

125

-0.73 22 14 37 115 0.32 6

14 2

125 0.39 11 14 so 095 0.42 12 14 2

135

-0.76 10 14 60 115 0.36 9

14 2

145 0.17 16 14 63 115 0.27 11 14 3

115

-0.84 8

14 63 125

-0.7 7

14 4

145

-0.78 12 14 63 125 0.41 13 14 5

.125

-0.71 13 14 65 145

-0.9 12 14 5

125 0.39 10 14 68 115 0.31 25 14 6

105

-0.7 23 14 69 125

-0.7 7

14 6

145

-0.9 11 14 69 155 0.39 12 14 7

105

-0.73 13 14 73 115 0.43 13 14 8

095 0.32 15 14 73 125

-0.63 7

14 8

145

-0.88 11 14 73 125 0.41 14 14 9

145

-0.88 8

14 74 115

-0.63 45 14 9

155 0.21 14 14 74 115 0.44 31 14 10 155 0.18 19 14 74 125

-0.71 24 14 11 155 0.14 14 14 74 135 0.37 12 14 12 155 0.14 7

14 77 125

-0.73 15 14 14 105

-0.72 16 14 77 125 0.34 24 14 15 105

-0.73 13 14 77 135 0.39 11 14 15 115 0.34 24 15 2

115

-0.73 21 14 15 155 0.18 8

15 2

125

-0.73 16 14 16 095 0.41 11 15 2

125 0.27 19 14 16 105

-0.72 22 15 2

135

-0.85 10 14 16 115

-0.79 9

15 2

145

-0.88 7

14 16 115 0.36 19 15 2

145 0.17 15 14 17 095 0.36 10 15 6

125 0.25 13 14 17 105

-0.75 17 15 6

145 0.2 8

14 17 115 0.34 30 15 7

115

-0.77 16 14 18 095 0.41 11 15 7

115 0.36 16 14 18 105

-0.72 34 15 8

095 0.39 9

14 18 115 0.29 16 15 8

105

-0.7 8

14 20 105

-0.72 33 15 8

115

-0.75 14 14 20 115

-0.77 8

15 8

115 0.3 9

14 20 115 0.29 28 15 9

105

-0.7 21 14 21 115 0.32 15 15 9

115

-0.77 10 14 21 145

-0.9 13 15 9

115 0.41 18 14 22 115 0.34 12 15 9

125 0.39 12 14, 35 115 0.29 9

15 9

145

-0.88 7

Page 13 of 85

TMI-1 Steam Generator Tube Inspection Report (Tl R22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 15 9

145 0.18 12 16 6

145 0.14 13 15 10 145

-0.91 7

16 7

105

-0.79 10 15 10 155

-0.91 8

16 7

125 0.34 21 15 10 155 0.18 10 16 8

115

-0.75 12 15 13 155 0.16 9

16 8

11S 0.36 9

15 17 11S 0.36 9

16 8

12S 0.34 27 15 18 115 0.34 14 16 8

155 0.16 13 15 21 09S 0.41 8

16 9

10S

-0.75 25 15 65 12S

-0.77 9

16 9

10S 0.29 10 15 66 115

-0.77 7

16 9

115

-0.77 26 15 66 12S

-0.73 8

16 9

11S 0.36 24 15 66 14S

-0.77 9

16 9

125 0.32 11 15 67 115 0.38 17 16 9

14S

-0.91 6

15 67 12S

-0.72 16 16 10 115

-0.75 10 15 67 12S 0.36 30 16 10 11S 0.36 19 15 67 14S

-0.8 10 16 11 15S 0.18 18 15 70 095 0.45 8

16 12 145 0.14 13 15 70 12S 0.43 8

16 14 14S

-0.95 7

15 72 10S 0.43 10 16 23 11S 0.32 11 15 75 115 0.47 9

16 68 11S 0.41 7

15 75 13S

-0.81 9

16 70 12S

-0.75 7

15 75 145 0.18 12 16 70 12S 0.39 7

15 76 115

-0.68 20 16 70 155

-0.84 6

15 76 125

-0.61 19 16 71 105 0.4 15 15 76 12S 0.41 20 16 74 10S 0.41 12 15 76 13S 0.32 14 16 74 115

-0.7 7

15 78 11S

-0.75 19 16 74 11S 0.45 11 15 78 125

-0.73 25 16 74 145

-0.81 16 15 78 12S 0.29 18 16 75 11S

-0.7 12 15 78 13S

-0.76 13 16 75 11S 0.43 34 15 80 125

-0.73 17 16 76 11S

-0.68 10 15 80 12S 0.34 16 16 76 11S 0.43 16 15 80 13S 0.34 15 16 76 125

-0.7 15 15 80 14S

-0.8 13 16 76 12S 0.34 18 15 80 14S 0.15 7

16 77 12S

-0.67 22 16 1

12S

-0.71 22 16 77 125 0.38 27 16 1

12S 0.37 10 16 77 135 0.34 16 16 2

125

-0.73 12 17 1

11S

-0.79 11 16 5

12S 0.17 15 17 1

12S

-0.79 9

16 6

10S

-0.72 17 17 2

11S

-0.82 9

Page 14 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 17 2

145 0.15 8

18 6

145 0.23 10 17 3

115

-0.73 13 18 7

105

-0.72 21 17 6

115

-0.72 12 18 7

115 0.34 14 17 6

115 0.36 17 18 7

155 0.16 8

17 6

145 0.21 7

18 8

095 0.25 11 17 8

105

-0.75 7

18 8

115

-0.75 13 17 8

115 0.34 19 18 8

115 0.34 20 17 8

155 0.23 8

18 8

125 0.32 13 17 9

115

-0.77

10.

18 9

105

-0.75 23 17 9

115 0.39 23 18 9

115

-0.82 13 17 9

155

-0.87 16 18 9

115 0.32 14 17 9

155 0.14 15 18 9

125 0.34 11 17 10 105

-0.74 11 18 9

145

-0.91 6

17 10 115

-0.79 6

18 10 105

-0.75 14 17 10 115 0.36 17 18 10 115

-0.75 13 17 10 155 0.16 12 18 10 115 0.36 18 17 11 115 0.36 14 18 10 155 0.16 11 17 12 155 0.18 10 18 11 115 0.36 11 17 15 145

-0.84 9

18 11 145

-0.79 12 17 15 155

-0.92 6

18 11 155 0.16 18 17 57 095 0.41 9

18 12 145

-0.88 8

17 76 115 0.43 10 18 12 155 0.18 15 17 77 105

-0.7 8

18 14 105

-0.82 6

17 77 115

-0.7 10 18 16 155 0.16 12 17 77 115 0.41 38 18 21 095

-0.76 14 17 77 145

-0.77 12 18 53 095

  • 0.38 9

17 79 115

-0.7 21 18 67 095

-0.77 9

17 79 115 0.43 11 18 70 085 0.38 7

17 79 125

-0.68 24 18 76 115 0.41 9

17 79 135 0.37 19 18 77 145

-0.73 31 17 80 115

-0.68 24 18 77 145 0.34 16 17 80 115 0.41 17 18 78 115

-0.7 6

17 80 125

-0.68 19 18 78 115 0.38 26 17 80 125 0.39 12 18 79 115

-0.67 22 17 80 135

-0.79 8

18 79 115 0.38 37 17 80 135 0.36 16 18 79 125

-0.7 15 17 84 125

-0.75 13 18 79 125 0.29 24 18 2

125 0.39 13 18 79 145

-0.82 19 18 2

135

-0.83 8

18 79 145 0.16 10 18 3

125 0.32 9

18 80 115

-0.65 12 Page 15 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 18 80 11S 0.43 8

19 11 14S

-0.91 14 18 80 12S 0.41 12 19 12 10S 0.36 11 18 81 11S 0.38 32 19 12 11S

-0.72 13 18 81 12S

-0.7 15 19 12 115 0.34 26 18 81 12S 0.34 29 19 12 155 0.2 7

18 81 13S 0.32 18 19 13 10S

-0.79 9

18 82 11S

-0.65 31 19 13 11S 0.34 12 18 82 11S 0.34 14 19 13 14S

-0.86 10 18 82 12S

-0.68 16 19 15 14S

-0.93 8

18 82 12S 0.41 23 19 15 14S

-0.82 12 18 82 13S

-0.7 7

19 17 095

-0.77 9

18 82 135 0.38 15 19 24 09S

-0.79 7

18 83 10S 0.39 22 19 74 08S 0.38 7

18 83 115

-0.66 41 19 79 11S 0.43 17 18 83 12S

-0.68 25 19 79 14S

-0.79 27 18 83 12S 0.24 14 19 80 115 0.41 19 18 83 13S

-0.75 20 19 80 14S 0.29 17 18 83 13S 0.39 12 19 83 11S

-0.65 13 18 83 14S

-0.76 10 19 83 11S 0.38 28 18 85 10S 0.39 22 19 84 11S

-0.67 18 18 85 12S

-0.71 13 19 84 11S 0.41 21 18 85 12S 0.29 6

19 85 10S 0.43 20 19 3

14S 0.17 13 19 85 115

-0.65 34 19 4

14S 0.18 13 19 85 11S 0.32 12 19 5

115

-0.76 17 19 85 125

-0.7 15 19 5

11S 0.38 13 19 87 11S

-0.73 20 19 5

12S 0.36 9

19 87 12S

-0.75 18 19 5

13S

-0.87 19 19 87 13S

-0.76 13 19 6

12S 0.29 11 19 87 13S 0.19 26 19 7

12S 0.27 11 19 88 10S 0.39 15 19 8

10S

-0.72 13 19 88 11S

-0.75 7

19 8

11S 0.34 6

20 1

11S

-0.73 8

19 9

11S 0.34 25 20 1

14S 0.2 12 19 9

15S 0.09 15 20 2

11S

-0.78 19 19 10 10S

-0.77 9

20 2

14S 0.22 14 19 10 11S

-0.79 10 20 3

14S 0.15 9

19 10 11S 0.34 18 20 4

11S

-0.75 10 19 10 14S

-0.86 10 20 4

11S 0.34 10 19 11 11S

-0.82 8

20 4

14S

-0.91 8

19 11 11S 0.34 22 20 5

11S 0.36 16 Page 16 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 20 6

11S 0.32 11 21 8

11S 0.34 11 20 7

11S 0.36 11 21 9

10S

-0.73 25 20 8

11S 0.34 13 21 9

11S 0.34 18 20 8

15S

-0.87 11 21 9

15S 0.16 11 20 9

09S 0.39 9

21 10 09S 0.36 6

20 9

11S 0.39 12 21 10 11S 0.32 17 20 9

14S

-0.86 8

21 10 14S

-0.95 6

20 10 10S

-0.72 8

21 11 11S 0.32 24 20 10 11S 0.34 14 21 11 15S 0.18 11 20 10 15S 0.14 15 21 12 11S 0.32 8

20 11 10S

-0.73 10 21 14 11S 0.32 17 20 11 11S 0.34 19 21 14 15S 0.18 9

20 12 11S 0.32 16 21 35 08S 0.34 9

20 31 10S

-0.81 7

21 39 08S 0.53 14 20 37 08S 0.54 9

21 43 09S 0.36 7

20 44 08S 0.49 14 21 44 08S 0.52 9

20 48 08S 0.36 14 21 52 07S 0.52 7

20 54 07S 0.58 9

21 52 08S 0.49 15 20 54 09S 0.38 10 21 53 08S 0.38 12 20 56 08S 0.55 12 21 55 07S 0.56 13 20 80 14S

-0.82 10 21 58 07S 0.56 15 20 81 11S 0.39 29 21 58 08S

-0.72 10 20 82 11S

-0.7 19 21 61 08S 0.32 12 20 82 11S 0.38 29 21 61 09S 0.41 10 20 82 14S

-0.75 10 21 63 07S 0.54 9

20 85 11S

-0.71 16 21 81 14S

-0.76 10 20 85 11S 0.43 29 21 82 10S

-0.72 7

20 86 11S

-0.7 12 21 82 11S 0.41 12 20 86 11S 0.41 32 21 82 12S 0.43 8

20 87 11S

-0.75 19 21 86 11S

-0.7 10 20 87 12S

-0.73 12 21 86 11S 0.38 44 21 1

13S

-0.78 12 21 87 11S 0.43 15 21 1

14S 0.2 16 21 90 11S

-0.75 18 21 2

14S 0.22 17 21 90 12S

-0.73 17 21 3

14S

-0.86 8

21 90 12S 0.41 14 21 5

14S 0.16 7

21 90 13S

-0.76 12 21 6

14S 0.21 7

21 90 14S 0.12 19 21 7

12S 0.3 12 22 1

11S

-0.73 9

21 7

15S 0.16 21 22 1

13S

-0.86 9

21 8

10S

-0.79 7

22 2

10S

-0.78 10 Page 17 of BS

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 22 2

115

-0.76 21 22 53 085 0.36 12 22 2

145

-0.76 10 22 57 095 0.38 7

22 2

145 0.17 16 22 58 085 0.38 15 22 3

115

-0.76 18 22 60 075 0.54 17 22 3

145 0.24 7

22 60 085

-0.7 15 22 4

145 0.25 9

22 60 115 0.25 10 22 5

145

-0.89 9

22 62 085 0.54 17 22 5

145 0.13 8

22 62 095 0.38 12 22 6

105

-0.77 8

22 63 075 0.54 16 22 6

115

-0.68 7

22 63 085

-0.72 21 22 6

115 0.34 7

22 63 085 0.36 13 22 6

145 0.16 9

22 63 095

-0.75 8

22 7

115

-0.77 12 22 63 095 0.39 8

22 7

115 0.32 19 22 64 085 0.54 9

22 7

135

-0.91 7

22 65 085 0.54 9

22 8

105

-0.74 27 22 67 075 0.52 7

22 8

125 0.27 10 22 67 085

-0.72 17 22 8

145 0.18 7

22 69 095 0.41 9

22 9

115 0.32 17 22 84 115 0.37 12 22 9

125 0.27 18 22 85 115 0.38 15 22 9

155 0.18 17 22 86 115

-0.7 11 22 10 105

-0.77 13 22 86 115 0.39 35 22 10 115

-0.82 6

22 86 145

-0.72 10 22 10 115 0.34 16 22 87 115 0.38 32 22 11 105

-0.7 11 22 88 115 0.41 20 22 11 115 0.32 18 22 89 115 0.36 33 22 11 125 0.27 9

22 90 115 0.43 29 22 11 155 0.18 17 22 91 115

-0.7 22 22 12 115

-0.75 9

22 91 115 0.29 18 22 12 115 0.32 17 22 92 115

-0.66 13 22 12 155 0.16 16 22 92 125

-0.7 10 22 27 085 0.47 12 22 92 125 0.27 18 22 33 085 0.36 13 23 1

115

-0.73 13 22 45 085 0.54 6

23 1

135

-0.81 9

22 46 075 0.58 10 23 2

115

-0.73 13 22 46 085

-0.75 19 23 2

135

-0.76 13 22 47 085 0.36 14 23 2

145 0.22 12 22 51 085

-0.74 10 23 6

155 0.14 21 22 52 085 0.36 9

23 7

115

-0.79 8

22 53 085

-0.74 10 23 7

115 0.32 11 Page 18 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 23 8

10S

-0.61 33 23 64 08S

-0.65 13 23 8

10S

-0.18 10 23 64 08S 0.38 13 23 8

11S 0.3 14 23 64 09S 0.36 7

23 8

155 0.11 11 23 65 085 0.5 8

23 9

095 0.32 6

23 66 085 0.54 13 23 9

115

-0.7 15 23 68 075 0.54 23 23 9

115 0.29 20 23 68 085

-0.65 14 23 9

155

-0.78 11 23 68 085 0.38 23 23 10 095 0.32 10 23 68 095 0.38 9

23 10 105

-0.77 23 23 69 085 0.36 7

23 10 125 0.25 16 23 69 095 0.41 9

23 10 145

-0.88 10 23 71 085 0.36 8

23 11 115

-0.79 7

23 85 105

-0.68 8

23 11 115 0.32 23 23 85 115 0.39 15 23 12 115

-0.82 7

23 86 115 0.36 27 23 12 115 0.32 11 23 88 105

-0.7 10 23 38 075 0.49 9

23 88 115 0.36 39 23 42 085 0.54 6

23 88 145

-0.73 15 23 43 075 0.56 11 23 89 115 0.41 11 23 43 085

-0.76 18 23 92 115

-0.68 10 23 43 085 0.36 17 23 93 115

-0.68 27 23 43 095

-0.63 8

23

  • 93 125

-0.71 10 23 43 095 0.38 7

23 93 125 0.22 21 23 45 07S 0.56 8

23 93 135

-0.75 9

23 46 085 0.36 12 23 94 125

-0.71 19 23 47 085

-0.76 11 23 94 135

-0.8 17 23 47 085 0.4 21 24 2

115

-0.73 11 23 47 095

-0.8 7

24 4

145 0.18 10 23 50 085 0.38 9

24 5

115

-0.77 8

23 52 085

-0.72 9

24 6

115

-0.77 9

23 52 08S 0.36 11 24 6

155 0.18 8

23 54 075 0.6 11 24 7

115

-0.77 9

23 54 085

-0.76 8

24 7

115 0.29 13 23 54 085 0.38 21 24 7

145 0.21 6

23 60 085 0.43 11 24 8

11S

-0.82 12 23 61 085

-0.74 13 24 8

115 0.27 16 23 61 085 0.38 21 24 8

155 0.18 12 23 61 095

-0.79 8

24 9

095 0.25 11 23 62 085 0.38 9

24 9

115

-0.77 18 23 64 075 0.52 8

24 9

115 0.32 14 Page 19 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 24 10 105

-0.72 10 24 86 115 0.43 9

24 10 115 0.27 12 24 87 115 0.4 8

24 11 115 0.29 15 24 89 115

-0.67 9

24 14 105

-0.79 8

24 90 115

-0.7 27 24 14 115 0.27 15 24 90 115 0.27 11 24 18 095

-0.79 15 24 90 145

-0.93 9

24 35 085 0.34 13 24 91 125

-0.75 11 24 37 075 0.53 9

24 91 125 0.17 9

24 37 085 0.34 19 24 91 135

-0.73 10 24 38 075 0.53 16 25 4

115

-0.77 10 24 38 085

-0.73 11 25 4

145 0.18 11 24 38 085 0.36 24 25 5

115

-0.77 15 24 41 085 0.36 13 25 5

125 0.25 13 24 42 075 0.53 20 25 5

145 0.18 5

24 42 085

-0.69 20 25 7

105

-0.7 13 24 42 085 0.34 22 25 7

115 0.27 10 24 42 095

-0.71 16 25 8

095 0.39 9

24 42 095 0.36 9

25 8

105 0.32 15 24 46 085 0.4 9

25 8

115

-0.84 12 24 47 075 0.58 9

25 8

115 0.3 16 24 47 085

-0.74 7

25 9

095 0.39 6

24 47 085 0.41 23 25 9

105

-0.77 6

24 47 095

-0.81 8

25 9

115 0.3 15 24 51 075 0.54 7

25 9

155 0.18 13 24 51 085

-0.78 9

25 10 115 0.3 12 24 51 085 0.38 13 25 10 155 0.18 10 24 53 075 0.54 13 25 11 145 0.11 9

24 53 085

-0.72 19 25 12 105

-0.75 6

24 53 085 0.4 19 25 12 115 0.23 23 24 53 095

-0.76 7

25 13 115 0.36 6

24 55 075 0.53 9

25 15 105

-0.84 7

24 55 085

-0.74 8

25 31 085

-0.79 8

24 55 085 0.34 14 25 33 075 0.54 13 24 57 085 0.38 9

25 33 085

-0.77 14 24 59 085

-0.76 13 25 33 095

-0.77 5

24 62 085

-0.72 8

25 33 115 0.23 5

24 83 115 0.38 12 25 34 085 0.34 13 24 84 145

-0.75 14 25 35 075 0.52 18 24 84 145 0.41 13 25 35 085

-0.74 14 24 85 145

-0.77 17 25 35 085 0.38 9

Page20 of 85

TM!-I Steam Generator Tube Inspection Report (Tl R22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 25 35 095

-0.79 7

25 60 085

-0.76 13 25 35 095 0.36 8

25 60 085 0.29 16 25 35 105

-0.81 7

25 61 085 0.36 6

25 36 075 0.58 7

25 65 075 0.59 8

25 36 085

-0.76 12 25 65 085 0.36 11 25 36 085 0.38 12 25 67 085

-0.72 9

25 39 085

-0.71 12 25 70 085

-0.74 11 25 39 085 0.38 23 25 88 145

-0.84 17 25 39 095

-0.78 7

25 91 115 0.41 12 25 39 125

-0.85 8

25 94 115

-0.7 11 25 40 075 0.54 6

25 96 115

-0.68 27 25 40 085 0.32 12 25 97 115

-0.73 13 25 41 085 0.34 14 25 98 125 0.41 12 25 42 075 0.54 9

26 2

115

-0.73 19 25 43 085

-0.8 9

26 2

145 0.12 10 25 44 075 0.58 8

26 7

115 0.3 10 25 45 075 0.6 8

26 7

155 0.18 9

25 45 085

-0.69 14 26 8

115 0.27 11 25 45 085 0.36 24 26 9

095 0.36 10 25 46 075 0.54 6

26 9

115 0.3 12 25 46 085

-0.7 13 26 10 095 0.39 6

25 46 085 0.41 9

26 10 115 0.29 15 25 46 095

-0.77 8

26 12 115 0.3 10 25 47 085 0.36 10 26 24 075 0.54 5

25 48 085 0.4 6

26 28 095 0.32 5

25 50 085

-0.78 6

26 29 085 0.38 15 25 50 085 0.38 11 26 30 085 0.52 7

25 51 075 0.56 9

26 30 095 0.39 7

25 51 085

-0.73 15 26 32 075 0.59 8

25 52 085

-0.76 8

26 32 085 0.38 15 25 55 075 0.55 10 26 37 085

-0.78 10 25 55 085

-0.67 12 26 41 085

-0.74 16 25 55 085 0.4 10 26 41 085 0.34 20 25 56 075

-0.61 14 26 41 095 0.36 9

25 56 075 0.56 12 26 42 055 0.49 7

25 56 085 0.38 10 26 43 075 0.56 16 25 58 075 0.38 7

26 43 085

-0.76 15 25 58 085

-0.65 12 26 43 095

-0.69 9

25 58 085 0.36 7

26 47 055 0.49 10 25 60 075 0.53 11 26 47 065

-0.73 9

Page 21 of 85

TM!-! Steam Generator Tube Inspection Report (Tl R22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by,Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 26 47 OBS 0.4 14 27 10 llS 0.29 10 26 54 07S 0.54 7

27 11 09S 0.39 8

26 60 OBS

-0.69 13 27 13 llS 0.27 8

26 60 OBS 0.38 7

27 24 09S 0.39 6

26 61 07S 0.55 15 27 31 OBS

-0.78 10 26 61 OBS

-0.73 26 27 31 OBS 0.38 14 26 61 09S

-0.71 11 27 32 ass 0.47 6

26 62 07S 0.56 9

27 32 OBS

-0.77 14 26 62 OBS

-0.72 12 27 34 OBS

-0.74 13 26 62 OBS 0.34 19 27 40 OBS

-0.76 7

26 64 OBS 0.4 10 27 41 OBS 0.45 8

26 65 07S 0.56 8

27 44 07S 0.54 7

26 65 OBS

-0.74 8

27 45 OBS 0.29 16 26 65 09S

-0.82 7

27 46 OBS

-0.74 6

26 68 OBS 0.4 12 27 48 OBS

-0.72 11 26 69 07S 0.57 16 27 49 OBS

-0.71 17 26 69 OBS

-0.72 9

27 49 OBS 0.38 13 26 69 OBS 0.39 11 27 52 OBS

-0.78 9

26 69 09S

-0.7 10 27 56 OBS

-0.65 8

26 70 06S 0.47 6

27 56 OBS 0.36 11 26 71 OBS 0.36 13 27 63 07S 0.43 8

26 76 OBS 0.38 11 27 63 OBS

-0.7 17 26 77 OBS 0.36 17 27 63 085 0.36 11 26 78 OBS 0.36 7

27 64 07S 0.58 9

26 78 09S 0.4 11 27 64 OBS

-0.72 26 26 87 lOS

-0.72 9

27 64 OBS 0.34 9

26 89 lOS

-0.67 14 27 67 OBS

-0.74 8

26 91 14S

-0.73 10 27 67 OBS 0.39 9

26 92 OBS 0.43 10 27 70 07S 0.56 8

26 97 llS

-0.68 14 27 70 OBS

-0.72 26 26 98 llS

-0.75 23 27 70 -ass 0.38 26 26 98 llS 0.29 11 27 70 09S

-0.7 12 26 98 14S

-0.98 10 27 71 07S 0.54 9

26 98 14S 0.17 10 27 71 OBS

-0.68 19 26 99 12S

-0.73 28 27 71 OBS 0.41 10 27 1

llS

-0.76 10 27 73 07S 0.56 10 27 1

12S

-0.76 13 27 73 OBS

-0.68 18 27 3

llS

-0.75 13 27 73 OBS 0.36 17 27 8

llS 0.32 8

27 74 OBS 0.36 14 27 9

llS 0.27 13 27 74 09S

-0.7 6

Page 22 of 85

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 27 75 08S 0.38 7

28 49 08S 0.33 8

27 76 07S 0.56 12 28 54 08S

-0.72 8

27 76 08S

-0.74 11 28 56 08S

-0.74 7

27 76 08S 0.4 13 28 56 08S 0.38 13 27 77 08S 0.41 7

28 57 07S 0.55 12 27 79 08S 0.52 8

28 57 08S

-0.75 17 27 97 11S 0.45 14 28 57 08S 0.38 19 27 98 12S 0.43 8

28 62 09S 0.41 6

27 99 11S

-0.68 12 28 65 08S

-0.74 12 27 99 11S 0.43 30 28 66 07S 0.49 15 27 100 11S

-0.75 13 28 66 08S

-0.72 12 27 100 11S 0.29 21 28 67 08S 0.54 12 27 100 14S 0.19 8

28 68 07S 0.56 9

27 101 11S

-0.66 11 28 68 08S

-0.7 16 27 101 12S 0.24 15 28 68 08S 0.4 11 27 102 11S

-0.78 11 28 71 07S 0.59 11 28 1

12S

-0.76 8

28 71 08S

-0.74 26 28 1

12S 0.34 13 28 71 08S 0.36 11 28 3

14S

-0.85 9

28 72 08S

-0.69 12 28 4

14S 0.21 12 28 74 08S

-0.74 10 28 5

12S 0.27 10 28 98 10S

-0.67 8

28 6

10S

-0.79 14 28 98 11S 0.41 17 28 7

09S 0.48 10 28 98 12S

-0.7 12 28 7

11S

-0.77 14 28 102 11S

-0.75 16 28 7

11S 0.34 10 28 102 11S 0.29 13 28 7

15S 0.18 7

28 103 14S

-0.93 12 28 8

10S 0.36 9

28 103 14S 0.15 10 28 8

11S

-0.77 21 29 1

11S

-0.76 11 28 8

15S 0.14 10 29 2

11S

-0.73 13 28 10 10S

-0.7 8

29 6

10S

-0.72 13 28 10 14S

-0.93 6

29 7

10S

-0.72 6

28 11 11S 0.27 10 29 7

12S

-0.79 7

28 15 14S

-0.86 8

29 7

13S

-0.91 7

28 28 08S

-0.77 7

29 8

11S 0.32 11 28 44 08S

-0.74 9

29 25 08S

-0.76 7

28 45 07S 0.53 12 29 29 08S

-0.74 6

28 46 07S 0.58 9

29 31 07S 0.58 6

28 46 08S

-0.74 16 29 31 08S

-0.79 7

28 46 09S 0.38 7

29 31 08S 0.34 12 28 49 08S

-0.71 8

29 33 08S 0.38 9

Page 23 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 29 34 085 0.36 12 29 83 085 0.54 8

29 35 085

-0.74 10 29 94 145

-0.79 9

29 35 085 0.38 8

29 94 145 0.32 8

29 36 075 0.58 12 29 103 115

-0.73 12 29 36 085

-0.76 16 29 103 115 0.27 23 29 36 085 0.34 9

29 104 135

-0.75 18 29 36 095

-0.69 15 30 1

115

-0.68 34 29 36 105 0.31 10 30 2

115

-0.78 12 29 36 115 0.27 9

30 2

115 0.37 8

29 38 085 0.36 11 30 2

145 0.17 8

29 39 085 0.38 10 30 4

145 0.18 10 29 39 095

-0.79 5

30 5

105

-0.79 8

29 40 085

-0.76 10 30 6

115 0.3 12 29 41 085

-0.74 8

30 6

145

-0.77 7

29 42 085

-0.78 16 30 7

115

-0.72 11 29 47 085

-0.77 9

30 7

115 0.25 9

29 47 085 0.36 11 30 8

095 0.36 8

29 49 075 0.58 9

30 9

095 0.36 6

29 49 085

-0.74 6

30 34 085 0.53 15 29 49 085 0.34 12 30 35 085

-0.74 9

29 56 085 0.38 10 30 37 085 0.38 10 29 58 075 0.57 7

30 38 085

-0.78 10 29 59 085

-0.67 9

30 40 075 0.51 10 29 59 08S 0.36 6

30 40 085

-0.69 18 29 60 085 0.35 8

30 51 085

-0.74 10 29 67 085

-0.74 20 30 51 085 0.36 11 29 67 085 0.38 10 30 54 085

-0.75 11 29 68 08S 0.54 10 30 54 085 0.33 11 29 70 085 0.52 11 30 55 075 0.54 15 29 72 075 0.56 6

30 55 08S

-0.74 14 29 72 085

-0.68 12 30 55 085 0.31 11 29 72 085 0.39 7

30 56 085 0.38 10 29 73 075 0.51 17 30 60 075 0.55 12 29 73 085

-0.72 23 30 60 085

-0.68 20 29 73 085 0.4 24 30 60 085 0.35 15 29 75 085 0.34 15 30 63 085

-0.71 18 29 76 085 0.38

. 10 30 64 085

-0.73 10 29 78 085 0.5 9

30 65 085

-0.72 12 29 80 085

-0.72 7

30 65 085 0.34 15 29 81 085

-0.74 14 30 68 085

-0.61 9

Page 24 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 30 74 075 0.43 9

31 28 095 0.34 9

30 74 085

-0.72 10 31 29 095 0.36 6

30 74 085 0.41 12 31 34 075

-0.54 13 30 76 085

-0.61 10 31 34 085

-0.78 8

30 77 085 0.36 12 31 38 085 0.38 13 30 78 085 0.39 11 31 49 085

-0.78 9

30 79 075 0.58 8

31 49 085 0.38 12 30 79 085

-0.73 10 31 51 085 0.36 10 30 81 075 0.56 15 31 55 085 0.4 10 30 81 085 0.42 16 31 63 085 0.4 9

30 82 085 0.36 10 31 65 085 0.39 8

30 84 085 0.56 9

31 66 085

-0.76 16 30 100 115 0.43 10 31 67 085

-0.59 13 30 102 115 0.43 8

31 72 085

-0.72 16 30 104 115

-0.75 9

31 73 085 0.5 11 30 104 115 0.29 23 31 76 085 0.34 11 30 105 135

-0.34 18 31 77 085

-0.76 11 30 105 145 0.12 9

31 77 085 0.38 7

31 2

105

-0.71 17 31 96 095

-0.74 17 31 2

145

-0.8 12 31 100 115 0.42 12 31 2

145 0.22 6

31 101 115 0.43 9

31 3

145 0.21 7

31 102 115 0.42 15 31 4

105

-0.77 19 31 105 115 0.27 20 31 5

105

-0.74 12 31 106 115

-0.75 12 31 5

115

-0.77 9

32 2

145 0.2 12 31 5

145

-0.93 16 32 3

135

-0.82 10 31 6

095 0.36 12 32 3

145 0.21 14 31 6

125

-0.82 8

32 4

115

-0.82 10 31 6

145 0.14 10 32 4

125 0.3 8

31 7

095 0.38 8

32 4

145 0.14 14 31 7

105 0.34 8

32 5

115

-0.75 10 31

7. 115

-0.77 11 32 5

115 0.32 7

31 7

115 0.3 9

32 6

115

-0.79 12 31 8

095 0.36 10 32 6

115 0.25 10 31 8

145

-0.91 7

32 6

145 0.23 7

31 8

155 0.18 18 32 7

095 0.38 6

31 10 115 0.2 8

32 7

105

-0.79 6

31 20 075 0.56 10 32 7

105 0.29 11 31 21 095 0.38 6

32 7

115

-0.81 10 31 27 095 0.36 7

32 7

115 0.3 9

Page 25 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 32 8

09S 0.39 9

32 65 08S

-0.74 10 32 9

10S

-0.79 18 32 65 08S 0.36 9

32 9

11S

-0.77 7

32 69 08S

-0.74 11 32 9

11S 0.27 10 32 69 08S 0.4 15 32 16 15S 0.16 12 32 70 08S

-0.77 8

32 22 09S 0.36 9

32 71 08S

-0.65 13 32 24 09S 0.36 12 32 75 08S

-0.72 7

32 25 08S 0.54 14 32 77 08S

-0.71 16 32 25 09S 0.39 7

32 79 08S

-0.72 13 32 26 08S

-0.76 9

32 79 08S 0.4 15 32 26 08S 0.38 12 32 96 14S

-0.75 11 32 28 08S

-0.78 10 32 100 08S 0.58 9

32 29 08S

-0.79 8

32 101 11S 0.43 9

32 29 08S 0.38 6

32 102 11S 0.45 22 32 30 08S

-0.78 9

32 102 12S 0.43 8

32 30 08S 0.34 8

32 105 11S

-0.68 10 32 30 09S 0.36 8

33 1

14S 0.12 10 32 32 08S

-0.78 10 33 2

10S

-0.71 11 32 32 08S 0.36 18 33 3

11S

-0.77 7

32 34 08S

-0.76 9

33 3

14S 0.2 11 32 37 08S 0.36 9

33 4

11S 0.23 11 32 38 08S

-0.75 11 33 5

11S

-0.75 12 32 38 08S 0.4 15 33 5

11S 0.27 14 32 41 08S

-0.76 10 33 5

14S 0.23 8

32 41 08S 0.38 8

33 6

09S 0.38 6

32 52 08S 0.42 14 33 6

11S

-0.75 12 32 55 07S 0.4 10 33 6

11S 0.3 11 32 55 08S

-0.74 9

33 6

14S

-0.82 11 32 55 08S 0.4 9

33 6

14S 0.21 7

32 55 10S

-0.81 7

33 7

11S

-0.77 11 32 56 08S 0.38 10 33 7

11S 0.3 12 32 57 07S 0.56 6

33 8

11S

-0.82 9

32 57 08S

-0.74 6

33 8

11S 0.27 13 32 58 07S 0.55 8

33 8

15S 0.16 10 32 58 08S

-0.73 9

33 9

14S

-0.84 9

32 59 08S

-0.73 9

33 9

14S 0.18 6

32 59 08S 0.31 9

33 14 15S

-0.91 8

32 60 08S

-0.77 8

33 23 08S 0.51 10 32 63 08S

-0.76 10 33 23 09S 0.36 10 32 63 08S 0.36 11 33 24 08S 0.36 9

Page 26 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 33 24 09S 0.36 7

33 99 14S

-0.75 29 33 25 OBS 0.34 13 33 100 14S

-0.77 29 33 27 OBS 0.4 10 33 101 11S 0.4 14 33 44 OBS

-0.78 10 33 102 lOS 0.41 12 33 44 OBS 0.29 16 33 102 11S 0.41 15 33 48 OBS

-0.76 9

33 103 11S 0.43 14 33 so OBS. -0.73 15 33 103 14S

-0.73 21 33 52 OBS 0.4 16 33 104 lOS

-0.67 12 33 58 07S 0.49 15 33 104 11S 0.43 23 33 58 OBS

-0.69 11 33 104 12S

-0.74 8

33 61 ass

-0.66 7

33 105 lOS

-0.67 12 33 61 06S

-0.51 14 33 105 11S 0.43 13 33 61 06S 0.58 8

33 105 12S 0.43 10 33 61 07S

-0.71 10 33 107 11S

-0.75 16 33 61 07S 0.42 15 33 107 11S 0.27 14 33 61 OBS

-0.71 19 34 1

11S

-0.73 21 33 61 OBS 0.36 15 34 3

lOS

-0.73 12 33 61 09S

-0.72 14 34 3

14S 0.17 12 33 61 09S 0.32 16 34 4

14S

-0.86 8

33 64 OBS 0.38 9

34 5

lOS

-0.68 9

33 65 OBS

-0.78 8

34 5

11S 0.27 11 33 65 OBS 0.38 6

34 6

15S 0.18 21 33 67 OBS

-0.74 10 34 7

09S 0.41 8

33 69 085 0.4 16 34 7

11S 0.3 15 33 71 08S

-0.74 8

34 8

095 0.36 6

33 71 08S 0.43 15 34 8

11S

-0.77 17 33 75 07S 0.54 15 34 9

11S

-0.79 9

33 75 08S

-0.72 16 34 9

145

-0.89 7

33 75 08S 0.36 20 34 9

145 0.14 8

33 76 07S 0.59 8

34 13 11S

-0.73 9

33 76 08S

-0.74 10 34 17 135 0.16 9

33 76 08S 0.36 19 34 20 09S 0.38 11 33 78 08S 0.41 9

34 22 09S 0.36 5

33 80 08S

-0.78 9

34 23 07S 0.54 9

33 80 08S 0.38 12 34 24 07S 0.52 6

33 82 OBS 0.4 11 34 25 07S 0.56 11 33 84 08S

-0.74 14 34 25 08S

-0.71 16 33 84 08S 0.38 13 34 25 09S

-0.76 9

33 85 07S 0.56 8

34 25 09S 0.36 9

33 98 145

-0.75 18 34 26 085

-0.74 13 Page 27 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 34 27 07S

-0.59 17 34 85 09S

-0.69 9

34 27 07S 0.56 9

34 87 08S

-0.71 18 34 27 08S

-0.76 16 34 100 14S

-0.81 8

34 28 08S 0.54 13 34 101 10S

-0.79 7

34 29 08S

-0.71 10 34 102 14S

-0.75 18 34 29 08S 0.38 13 34 103 11S 0.43 8

34 30 08S

-0.77 7

34 104 14S

-0.73 17 34 30 085 0.34 9

34 104 14S 0.43 12 34 31 08S

-0.78 10 34 105 14S

-0.77 22 34 31 08S 0.38 10 34 105 145 0.36 23 34 32 085 0.34 11 34 106 10S 0.36 13 34 54 08S

-0.74 8

34 106 11S

-0.72 9

34 54 085 0.41 9

34 106 11S 0.4 24 34 56 08S

-0.76 12 34 106 12S

-0.72 10 34 59 08S

-0.77 9

34 107 11S 0.45 12 34 59 08S 0.38 9

34 110 11S 0.29 13 34 61 08S

-0.73 15 35 2

10S

-0.73 9

34 61 08S 0.38 12 35 2

11S

-0.73 10 34 61 095

-0.8 11 35 3

10S

-0.7 16 34 61 09S 0.4 10 35 4

10S 0.34 7

34 64 075 0.58 10 35 4

11S

-0.72 9

34 64 085 0.36 9

35 4

11S 0.32 12 34 67 08S 0.4 9

35 4

145 0.18 8

34 69 085

-0.74 8

35 5

105

-0.79 7

34 69 08S 0.4 18 35 5

115 0.32 9

34 69 095

-0.79 10 35 6

115 0.3 20 34 71 08S 0.4 18 35 7

09S 0.36 12 34 73 085

-0.76 10 35 7

155 0.16 14 34 73 08S 0.38 16 35 14 15S 0.11 8

34 78 085

-0.74 9

35 21 095 0.36 6

34 78 09S

-0.72 12 35 22 10S

-0.84 6

34 80 08S

-0.76 7

35 23 08S 0.54 8

34 80 08S 0.4 11 35 24 09S 0.36 6

34 81 08S

-0.74 8

35 25 09S 0.36 8

34 81 085 0.4 10 35 29 08S 0.38 12 34 81 09S

-0.71 7

35 33 08S 0.36 18 34 82 07S 0.53 8

35 33 09S

-0.78 6

34 84 08S

-0.69 12 35 33 095 0.34 7

34 85 085

-0.71 14 35 35 085 0.36 11 34 85 085 0.4 23 35 37 08S 0.4 10 Page 28 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1.

SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 35 41 08S

-0.78 7

35 108 11S 0.38 25 35 41 085 0.38 10 35 108 125 0.38 10 35 45 085 0.36 8

35 109 115

-0.68 9

35 53 085

-0.76 7

35 109 115 0.45 13 35 56 085

-0.8 8

35 111 115

-0.7 12 35 56 085 0.4 20 35 111 115 0.32 24 35 60 085 0.4 16 35 112 105 0.27 10 35 60 095

-0.78 9

36 2

125

-0.71 10 35 62 08S 0.42 12 36 4

10S

-0.77 6

35 66 085 0.38 12 36 4

11S

-0.75 11 35 68 08S 0.41 12 36 4

11S 0.32 8

35 68 09S

-0.79 7

36 4

145 0.16 15 35 70 08S 0.41 13 36 5

10S

-0.77 9

35 72 08S 0.38 12 36 6

115

-0.82 11 35 74 085 0.41 17 36 6

115 0.27 16 35 76 08S 0.36 11 36 6

12S 0.6 8

35 81 08S 0.4 7

36 6

15S 0.16 13 35 82 08S

-0.73 16 36 7

09S

-0.7 6

35 82 08S 0.4 22 36 7

09S 0.36 6

35 85 08S

-0.74 8

36 7

14S 0.18 10 35 86 07S 0.56 9

36 8

09S 0.39 9

35 87 08S 0.4 7

36 10 14S 0.18 7

35 99 14S

~o.n 19 36 11 14S 0.14 7

35 100 14S

-0.75 17 36 25 10S

-0.84 5

35 100 145 0.34 16 36 27 07S 0.47 7

35 101 14S

-0.77 24 36 27. 08S

-0.59 13 35 101 14S 0.36 8

36 28 08S 0.34 12 35 102 14S

-0.77 39 36 30 08S

-0.65 18 35 103 14S

-0.77 25 36 30 08S 0.36 13 35 103 14S 0.32 18 36 30 11S 0.27 6

35 104 10S

-0.7 13 36 33 08S

-0.61 14 35 104 145

-0.77 17 36 33 08S 0.52 9

35 104 145 o:38 10 36 35 08S

-0.72 11 35 105 105

-0.68 12 36 35 085 0.41 11 35 105 115 0.41 14 36 40 08S

-0.76 11 35 105 14S

-0.73 15 36 40 085 0.42 13 35 105 14S 0.38 16 36 41 08S

-0.76 14 35 108 10S

-0.67 13 36 41 08S 0.41 8

35 108 10S 0.31 16 36 43 07S 0.56 8

35 108 11S

-0.69 10 36 44 08S

-0.78 12 Page 29 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 36 58 08S 0.4 13 37 4

14S 0.14 9

36 60 08S 0.4 18 37 5

10S

-0.79 5

36 61 08S

-0.69 11 37 5

11S s0.84 8

36 61 08S 0.43 13 37 5

14S 0.25 9

36 75 08S

-0.74 7

37 6

11S

-0.75 7

36 75 08S 0.36 7

37 6

11S 0.34 7

36 77 07S

-0.63 12 37 6

12S

-0.79 18 36 77 07S 0.59 7

37 6

12S 0.29 13 36 79 08S

-0.68 9

37 7

09S

-0.66 6

36 79 08S 0.38 14 37 7

11S

-0.79 13 36 80 08S

-0.67 10 37 8

09S 0.41 7

36 80 08S 0.4 16 37 9

15S 0.14 14 36 82 08S

-0.78 9

37 14 10S

-0.86 7

36 82 08S 0.38 9

37 28 08S 0.52 11 36 85 08S 0.38 15 37 33 08S 0.38 18 36 86 08S

-0.74 13 37 33 09S 0.38 7

36 86 08S 0.38 19 37 38 08S

-0.74 8

36 89 08S 0.4 10 37 38 08S 0.43 6

36 90 08S

-0.65 8

37 45 08S

-0.69 15 36 90 08S 0.36 11 37 48 06S

-0.61 7

36 92 08S

-0.72 11 37 48 08S

-0.74 14 36 102 14S

-0.79 13 37 48 08S 0.4 11 36 102 14S 0.36 14 37 49 08S

-0.73 8

36. 103 10S

-0.75 11 37 55 08S 0.42 11 36 105 14S

-0.75 30 37 56 07S 0.51 9

36 105 14S 0.36 30 37 56 08S

-0.74 10 36 106 11S 0.41 13 37 56 08S 0.38 11 36 106 14S

-0.75 22 37 57 08S

-0.77 13 36 107 10S

-0.65 6

37 57 08S 0.4 13 36 109 11S 0.43 12 37 57 09S

-0.78 7

36 112 11S

-0.73 8

37 57 09S 0.38 7

36 112 11S 0.27 19 37 59 08S 0.42 18 36 113 11S

-0.63 19 37 61 08S

-0.73 16 36 113 11S 0.49 23 37 61 08S 0.4 16 37 1

14S 0.2 10 37 61 09S

-0.78 7

37 2

10S

-0.73 14 37 62 07S 0.58 8

37 3

14S 0.18 12 37 62 08S

-0.67 10 37 4

10S

-0.79 5

37 62 08S 0.4 10 37 4

11S 0.32 9

37 62 09S

-0.78 6

37 4

12S

-0.75 16 37 64 08S

-0.74 8

Page 30 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 37 73 085 0.36 12 37 106 115 0.43 9

37 74 085

-0.76 8

37 106 145

-0.77 19 37 74 085 0.38 19 37 106 145 0.34 16 37 78 085 0.43 11 37 106 155

-0.75 11 37 79 085

-0.7 7

37 107 115 0.43 9

37 79 085 0.41 11 37 107 145

-0.73 20 37 80 085

-0.74 11 37 107 145 0.39 19 37 80 085 0.4 11 37 107 155

-0.75 10 37 81 085 0.38 16 37 110 115 0.43 24 37 83 085

-0.76 12 37 111 115 0.45 13 37 83 085 0.38 16 37 114 115

-0.63 17 37 84 085 0.4 12 37 114 115 0.49 31 37 85 085

-0.73 17 38 3

115 0.29 9

37 85 085 0.38 23 38 3

145 0.18 11 37 85 095

-0.78 7

38 4

105

-0.73 10 37 87 085

-0.71 20 38 4

115

-0.75 9

37 87 085 0.38 12 38 4

115 0.32 17 37 88 085

-0.7 16 38 4

145 0.16 12 37 88 085 0.38 10 38 5

105

-0.79 9

37 89 085 0.42 10 38 5

115

-0.79 8

37 90 085

-0.67 12 38 6

115

-0.82 9

37 90 085 0.36 7

38 7

095 0.34 10 37 91 065

-0.69 7

38 7

115

-0.79 9

37 91 085

-0.71 12 38 8

115

-0.84 7

37 91 085 0.4 13 38 9

155 0.18 8

37 92 085 0.54 6

38 21 095 0.34 7

37 93 085 0.36 7

38 24 075 0.52 6

37 94 085 0.47 12 38 25 095 0.38 7

37 102 075

-0.41 7

38 28 085

-0.59 10 37 102 145

-0.79 32 38 28 085 0.52 6

37 102 145 0.34 18 38 29 085 0.38 7

37 102 155

-0.84 7

38 29 095 0.34 7

37 104 105

-0.7 10 38 30 085

-0.74 12 37 104 115 0.36 12 38 30 085 0.36 11 37 104 145

-0.77 32 38 31 095 0.34 7

37 104 145 0.34 24 38 32 085 0.54 5

37 104 155

-0.79 13 38 33 085 0.36 19 37 105 145

-0.77 23 38 34 085 0.54 13 37 105 145 0.34 19 38 35 085 0.38 15 37 105 155

-0.75 14 38 37 085

-0.76 10 Page 31 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 38 37 08S 0.36 17 38 108 15S

-0.75 12 38 43 08S

-0.78 8

38 111 10S

-0.68 8

38 44 08S 0.36 11 38 111 10S 0.41 14 38 50 08S 0.38 5

38 111 11S 0.45 15 38 52 08S

-0.78 9

38 112 10S

-0.7 9

38 52 09S

-0.79 6

38 112 11S

-0.7 10 38 57 07S 0.44 14 38 112 11S 0.43 24 38 57 08S

-0.71 22 38 115 11S

-0.63 11 38 57 08S 0.42 11 39 1

06S

-0.68 7

38 57 09S

-0.73 14 39 1

10S

-0.73 11 38 57 09S 0.33 28 39 1

11S

-0.75 10 38 60 08S 0.43 10 39 4

10S

-0.75 13 38 65 08S

-0.75 12 39 4

14S 0.21 8

38 66 08S

-0.78 8

39 5

09S 0.39 11 38 67 08S

-0.66 23 39 5

14S 0.2 17 38 67 08S 0.4 13 39 6

13S

-0.91 7

38 69 08S 0.38 11 39 6

14S

-0.88 7

38 70 09S

-0.79 8

39 7

09S 0.34 12 38 73 08S

-0.74 9

39 7

11S

-0.79 19 38 74 08S

-0.71 10 39 7

14S 0.23 10 38 75 08S 0.41 10 39 8

09S 0.36 9

38 79 08S

-0.72 6

39 8

11S 0.27 9

38 79 08S 0.39 9

39 8

15S 0.14 8

38 82 08S

-0.77 8

39 9

11S 0.3 14 38 82 08S 0.41 7

39 9

14S

-0.91 10 38 84 08S 0.4 11 39 11 15S 0.09 7

38 86 08S

-0.74 9

39 23 08S 0.56 8

38 87 07S

-0.58 14 39 30 08S 0.34 9

38 87 07S 0.6 8

39 31 08S 0.36 7

38 88 08S

-0.74 7

39 31 09S 0.36 7

38 103 14S

-0.79 23 39 33 08S

-0.63 13 38 103 14S 0.32 20 39 33 08S 0.49 13 38 104 11S 0.36 11 39 34 08S 0.29 6

38 104 14S

-0.77 11 39 35 08S 0.38 18 38 106 14S 0.32 8

39 36 08S 0.38 10 38 108 10S

-0.7 14 39 40 08S 0.43 8

38 108 10S 0.38 16 39 42 08S

-0.76 10 38 108 11S 0.39 15 39 42 08S 0.36 7

38 108 14S

-0.73 13 39 43 08S 0.4 10 38 108 14S 0.34 17 39 44 08S

-0.72 16 Page 32 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 39

  • 44 085 0.43 9

39 112 105

-0.68 9

39 48 085

-0.77 11 39 112 105 0.36 11 39 56 085

-0.7 10 39 112 11S

-0.72 9

39 56 09S 0.4 11 39 112 115 0.45 15 39 69 08S

-0.72 13 39 112 125 0.45 9

39 69 085 0.41 11 39 113 105 0.43 9

39 69 095

-0.72 9

39 113 11S 0.47 10 39 69 09S 0.38 12 39 114 105

-0.68 16 39 70 085

-0.67 13 39 116 11S

-0.61 17 39 70 085 0.34 13 40 1

14S 0.17 9

39 71 085 0.39 9

40 2

10S

-0.7 11 39 73 08S 0.41 10 40 2

14S

-0.7 8

39 74 06S

-0.58 12 40 2

14S 0.17 12 39 74 06S 0.56 12 40 3

115 0.27 10 39 74 07S

-0.63 11 40 4

095 0.41 11 39 74 07S 0.56 22 40 5

09S 0.34 10 39 74 085

-0.72 17 40 5

10S 0.32 7

39 74 09S

-0.72 10 40 5

14S

-0.81 11 39 74 095 0.4 12 40 5

14S 0.23 13 39 76 08S

-0.74 12 40 5

15S 0.18 17 39 76 085 0.4 15 40 6

08S 0.45 8

39 77 07S 0.56 6

40 9

155 0.18 7

39 77 08S

-0.75 11 40 21 08S

-0.58 13 39 77 08S 0.39 13 40 22 09S 0.34 11 39 79 07S

-0.59 14 40 25 08S 0.54 8

39 80 08S 0.43 8

40 26 08S 0.54 7

39 88 08S

-0.76 12 40 26 09S 0.36 9

39 90 085

-0.73 10 40 30 08S

-0.52 9

39 90 085 0.36 8

40 30 08S 0.45 9

39 91 085 0.4 9

40 63 08S 0.43 20 39 95 08S

-0.76 8

40 68 08S

-0.77 7

39 104 14S 0.32 11 40 80 08S

-0.74 9

39 106 14S

-0.77 11 40 80 095

-0.78 7

39 107 15S

-0.79 11 40 80 09S 0.4 7

39 107 15S 0.39 15 40 82 08S

-0.74 11 39 108 14S 0.41 6

40 82 08S 0.4 20 39 108 155

-0.79 8

40 83 08S 0.38 8

39 109 125 0.43 10 40 84 085 0.38 17 39 111 10S 0.38 11 40 91 07S

-0.61 14 39 111 11S 0.41 15 40 91 08S

-0.67 8

Page 33 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22

\\

Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 40 91 08S 0.43 7

41 85 08S

-0.72 13 40 92 08S

-0.73 11 41 90 08S 0.36 11 40 92 08S 0.4 10 41 91 07S 0.58 6

40 94 07S 0.58 11 41 91 08S

-0.74 12 40 94 08S

-0.69 20 41 92 08S

-0.77 9

40 94 09S

-0.71 9

41 94 08S 0.42 8

40 95 06S

-0.72 7

41 95 08S

-0.74 15 40 95 08S

-0.72 15 41 95 08S 0.4 14 40 95 08S 0.41 10 41 95 09S

-0.81 8

40 107 14S

-0.84 12 41 96 08S 0.38 18 40 107 14S 0.41 9

41 100 08S 0.4 10 40 109 14S

-0.77 13 41 106 14S

-0.81 11 40 109 14S 0.41 12 41 106 14S 0.23 14 40 109 15S

-0.77 9

41 108 11S 0.41 8

40 109 15S 0.41 10 42 2

14S

-0.82 15 40 111 10S

-0.65 17 42 2

14S 0.17 15 40 112 11S 0.45 11 42 3

14S

-0.88 8

41 1

06S

-0.71 9

42 4

09S 0.41 10 41 1

10S

-0.76 10 42 5

15S 0.18 30 41 2

10S

-0.73 7

42 6

15S 0.21 10 41 2

14S

-0.8 14 42 19 09S 0.34 7

41 2

14S 0.19 10 42 21 09S 0.34 8

41 4

14S

-0.84 9

42 22 09S 0.34 8

41 4

14S 0.23 13 42 23 08S 0.36 9

41 5

11S 0.34 12 42 25 07S 0.58 7

41 6

15S 0.21 9

42 25 08S

-0.6 14 41 8

15S 0.16 11 42 25 08S 0.51 11 41 19 08S 0.52 6

42 25 095

-0.78 8

41 26 08S 0.34 15 42 26 07S 0.56 7

41 27 08S

-0.77 11 42 26 08S

-0.76 10 41 27 09S 0.36 4

42 26 08S 0.34 17 41 30 09S 0.38 9

42 26 09S

-0.79 6

41 32 08S 0.33 15 42 28 09S 0.32 7

41 32 09S 0.36 8

42 29 09S

-0.74 9

41 37 08S 0.52 10 42 29 09S 0.34 7

41 38 08S 0.38 18 42 30 09S 0.34 7

41 64 08S 0.43 15 42 32 08S 0.49 7

41 68 08S

-0.76 14 42 36 07S

-0.63 11 41 78 08S

-0.74 7

42 41 08S

-0.78 15 41 84 08S 0.38 12 42 62 08S 0.43 14 Page 34 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 42 67 085 0.43 9

43 24 085

-0.59 13 42 69 085 0.38 11 43 25 075 0.56 9

42 74 065 0.61 7

43 25 085 0.54 9

42 74 075

-0.75 6

43 25 095

-0.72 8

42 74 075 0.43 16 43 25 095 0.34 7

42 74 085

-0.7 10 43 26 085 0.36 7

42 74 085 0.43 10 43 27 085 0.36 10 42 74 095

-0.79 8

43 30 085

-0.56 7

42 74 095 0.41 10 43 32 085

-0.63 9

42 75 085 0.4 13 43 34 085 0.36 10 42 82 075

-0.74 13 43 36 085

-0.76 16 42 82 085

-0.75 9

43 36 085 0.31 11 42 82 085 0.38 7

43 37 075 0.58 8

42 83 085

-0.7 10 43 37 085

-0.76 19 42 83 085 0.36 13 43 65 085 0.42 11 42 85 085 0.33 8

43 67 085 0.38 15 42 88 085

-0.76 10 43 70 085 0.42 12 42 88 085 0.38 10 43 72 085

-0.74 7

42 90 085 0.4 10 43 72 085 0.42 12 42 91 085

-0.62 10 43 73 085 0.43 15 42 92 085

-0.72 13 43 77 085 0.43 12 42 107 115

-0.68 13 43 78 085 0.4 14 42 107 115 0.38 19 43 83 085 0.45 7

42 107 155 0.41 10 43 85 085 0.38 15 42 108 105

-0.72 9

43 88 085

-0.73 11 42 111 105

-0.65 20 43 88 085 0.33 12 42 111 115 0.41 9

43 89 085

-0.76 12 42 112 125 0.37 19 43 90 085

-0.71 8

43 2

095

-0.69 7

43 91 085

-0.74 9

43 2

145

-0.76 10 43 91 085 0.36 8

43 3

105 0.36 8

43 93 085

-0.72 7

43 3

145

-0.86 7

43 93 085 0.36 14 43 3

145 0.18 10 43 94 085

-0.71 9

43 4

095 0.45 9

43 111 115 0.41 10 43 4

145

-0.86 7

43 111 155 0.41 7

43 5

145

-0.9 15 43 112 115

-0.67 19 43 5

155 0.23 10 43 112 115 0.4 27 43 6

145

-0.84 16 43 113 105

-0.68 11 43 19 095 0.34 6

43 113 125

-0.7 8

43 22 085

-0.52 12 43 114 105 0.36 16 Page 35 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 43 114 11S

-0.65 11 44 84 08S

-0.69 14 43 114 11S 0.45 24 44 86 08S 0.4 8

43 115 10S

-0.7 16 44 95 08S

-0.72 8

43 116 12S

-0.7 20 44 96 08S

-0.71 10 44 1

09S

-0.76 10 44 97 08S

-0.72 10 44 1

10S

-0.73 15 44 100 08S 0.38 8

44 4

09S 0.38 16 44 112 14S

-0.76 15 44 4

11S 0.31 6

44 113 10S

-0.72 10 44 5

14S

-0.75 19 44 114 10S

-0.69 9

44 5

15S 0.18 26 45 1

14S

-0.76 13 44 6

13S

-0.82 7

45 1

14S 0.15 16 44 6

14S

-0.79 22 45 3

09S 0.38 12 44 6

15S

-0.91 8

45 4

09S 0.41 10 44 6

15S 0.18 28 45 4

11S 0.31 11 44 7

08S 0.43 11 45 4

14S

-0.86 16 44 11 14S

-0.91 5

45 4

14S 0.2 12 44 26 08S 0.34 12 45 4

15S 0.2 12 44 28 09S 0.38 8

45 5

09S 0.41 17 44 29 09S 0.36 7

45 5

11S 0.32 8

44 30 09S 0.36 6

45 5

14S

-0.83 11 44 61 08S 0.4 7

45 5

15S 0.16 20 44 62 09S 0.4 7

45 15 09S 0.38 9

44 63 08S 0.4 11 45 25 08S

-0.58 12 44 65 08S 0.42 6

45 25 09S

-0.74 14 44 67 08S 0.4 10 45 26 08S 0.52 5

44 69 08S

-0.76 8

45 26 09S 0.38 7

44 69 08S 0.4 16 45 27 08S

-0.78 11 44 70 08S 0.43 6

45 27 08S 0.36 13 44 71 08S 0.43 9

45 27 09S 0.36 6

44 73 08S 0.38 9

45 29 09S 0.34 9

44 74 08S 0.4 12 45 31 08S

-0.76 11 44 75 08S 0.45 9

45 32 09S 0.34 6

44 77 08S 0.41 7

45 33 08S

-0.76 12 44 78 08S 0.34 14 45 63 08S 0.41 7

44 79 08S 0.41 12 45 68 08S 0.42 10 44 80 08S 0.42 16 45 70 08S

-0.74 7

44 81 08S

-0.65 7

45 70 08S 0.43 8

44 81 08S 0.41 12 45 70 09S

-0.76 8

44 83 08S

-0.74 9

45 72 08S 0.38 13 44 83 08S 0.41 7

45 73 08S 0.42 17 Page 36 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 45 76 085

-0.72 6

46 6

095 0.41 14 45 76 085 0.38 8

46 6

115 0.32 10 45 76 095

-0.72 7

46 6

145

-0.82 11 45 77 085 0.42 9

46 6

155

-0.77 14 45 79 085 0.42 8

46 6

155 0.14 31 45 80 085 0.45 10 46 7

145

-0.84 17 45 81 085 0.4 11 46 7

155 0.11 21 45 83 075

-0.62 12 46 22 085

-0.56 9

45 83 085

-0.76 8

46 22 085 0.52 12 45 84 075

-0.61 13 46 22 095 0.32 7

45 84 075 0.56 15 46 23 095 0.36 13 45 84 085

-0.76 13 46 24 085 0.47 6

45 84 085 0.38 14 46 24 095 0.36 5

45 90 085

-0.74 10 46 25 095 0.36 7

45 90 085 0.36 11 46 27 085 0.34 16 45 92 085

-0.74 10 46 27 095

-0.7 9

45 94 085

-0.74 13 46 27 095 0.36 10 45 97 085 0.31 8

46 31 085 0.41 10 45 101 085 0.54 7

46 33 085 0.38 12 45 112 105

-0.68 9

46 38 085 0.34 5

45 113 115 0.4 11 46 47 085

-0.69 8

45 113 145

-0.79 9

46 68 085

-0.78 7

45 115 105

-0.69 12 46 70 075

-0.74 10 45 116 115 0.48 9

46 70 085

-0.67 12 45 118 115

-0.7 24 46 70 095

-0.78 6

45 118 115 0.41 9

46 74 085 0.43 10 45 118 125 0.39 12 46 75 085 0.43 12 46 1

105

-0.73 13 46 76 085 0.36 7

46 1

145

-0.76 15 46 76 095

-0.77 5

46 1

145 0.17 19 46 79 085

-0.67 10 46 2

145 0.2 11 46 79 095

-0.81 6

46 3

105

-0.79 12 46 82 075 0.58 9

46 3

145

-0.86 10 46 82 085

-0.72 5

46 3

145 0.23 10 46 82 085 0.41 9

46 4

115 0.32 12 46 83 085

-0.73 8

46 4

145 0.2 7

46 84 065

-0.57 12 46 4

155 0.2 10 46 84 075 0.36 24 46 5

115 0.29 8

46 84 085

-0.72 25 46 5

155 0.16 26 46 84 085 0.34 8

46 6

085 0.67 12 46 89 075

-0.6 11 Page 37 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 46 89 085 0.4 14 47 4

145

-0.86 13 46 94 085

-0.74 8

47 4

145 0.23 13 46 96 085

-0.72 8

47 4

155

-0.91 8

46 103 085

-0.73 8

47 4

155 0.2 11 46 105 105

-0.79 13 47 5

105 0.36 16 46 111 105

-0.72 13 47 5

115 0.29 15 46 112 105

-0.68 8

47 5

145 0.2 8

46 112 105 0.41 9

47 5

155 0.16 16 46 112 115 0.32 10 47 6

115 0.32 10 46 113 105

-0.7 14 47 6

155 0.18 21 46 113 105 0.4 8

47 7

095 0.36 12 46 113 115

-0.7 14 47 7

115 0.29 16 46 113 115 0.36 24 47 7

145

-0.88 11 46 114 105

-0.68 13 47 7

155 0.2 19 46 114 105 0.41 8

47 22 085 0.52 8

46 114 115 0.45 7

47 22 095

-0.68 7

46 115 105

-0.67 11 47 23 085

-0.61 10 46 115 105 0.38 17 47 23 095 0.32 9

46 115 115

-0.67 11 47 24 085 0.36 7

46 115 115 0.36 32 47 26 085

-0.74 10 46 116 105

-0.7 13 47 26 085 0.36 6

46 116 115

-0.68 10 47 26 095

-0.79 9

46 116 115 0.45 6

47 26 095 0.36 5

46 118 105

-0.7 10 47 27 085

-0.56 14 46 118 105 0.41 14 47 27 085 0.54 10 46 118 115

-0.65 14 47 28 085 0.47 12 46 118 125

-0.68 16 47 29 085

-0.78 11 46 118 125 0.41 25 47 68 085 0.38 9

46 118 135

-0.71 11 47 70 085 0.4 10 46 119 115

-0.63 14 47 73 085 0.4 10 47 1

105

-0.76 12 47 74 085 0.43 10 47 1

145

-0.79 14 47 74 095

-0.72 6

47 1

145 0.2 16 47 75 085 0.43 13 47 2

105

-0.71 11 47 76 085 0.41 18 47 2

115

-0.73 11 47 77 085 0.38 9

47 3

105 0.34 20 47 82 075 0.41 12 47 3

115 0.34 12 47 82 085

-0.65 10 47 4

105

-0.72 13 47 82 085 0.41 9

47 4

105 0.27 15 47 82 095 0.41 7

47 4

115 0.27 12 47 83 055 0.52 6

Page 38 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 47 83 06S

-0.61 11 48 5

15S 0.11 18 47 83 OBS 0.4 23 48 6

llS

-0.77 9

47 83 09S 0.36 10 48 6

llS 0.32 12 47 83 lOS

-0.83 9

48 6

15S 0.18 17 47 84 OBS 0.43 9

48 8

llS 0.27 12 47 90 OBS

-0.72 6

48 8

14S

-0.86 9

47 93 OBS

-0.71 9

48 18 OBS 0.56 11 47 96 OBS

-0.72 8

48 20 09S 0.34 8

47 97 OBS

-0.78 8

48 23 09S 0.34 7

47 98 OBS 0.34 17 48 24 OBS 0.54 22 47 101 OBS 0.38 13 48 24 09S

-0.67 8

47 102 OBS 0.36 6

48 24 09S 0.32 8

47 109 lOS

-0.74 10 48 26 09S 0.36 11 47 111 lOS

-0.7 14 48 27 09S

-0.74 8

47 111 llS 0.41 13 48 28 09S

-0.81 9

47 112 lOS

-0.7 8

48 28 09S 0.32 11 47 113 llS

-0.67 16 48 29 09S

-0.77 6

47 113 llS 0.38 24 48 29 09S 0.34 6

47 115 lOS

-0.69 11 48 33 OBS 0.36 8

47 115 llS

-0.7 10 48 33 09S 0.36 7

47 115 llS 0.4 16 48 34 OBS 0.38 9

47 116 lOS

-0.7 7

48 34 09S 0.38 7

47 116 lOS 0.38 10 48 36 OBS 0.36 8

47 116 llS 0.45 14 48 77 OBS 0.38 15 47 116 12S 0.43 8

48 78 OBS 0.38 8

47 117 llS

-0.65 11 48 90 085

-0.79 5

47 117 12S

-0.7 11 48 91 OBS

-0.76 7

47 118 llS

-0.7 17 48 93 OBS

-0.76 6

47 118 llS 0.39 23 48 93 OBS 0.38 17 47 118 12S

-0.73 16 48 94 OBS

-0.79 11 47 118 12S 0.41 12 48 94 OBS 0.38 14 48 1

lOS

-0.73 11 48 95 OBS 0.38 8

48 1

14S 0.15 21 48 97 OBS

-0.71 12 48 2

llS

-0.73 12 48 98 OBS

-0.74 11 48 2

14S

-0.76 10 48 99 OBS

-0.62 7

48 3

lOS

-0.77 9

48 113 lOS

-0.7 13 48 4

lOS 0.34 11 48 113 llS

-0.7 18 48 4

llS 0.36 9

48 113 llS 0.34 21 48 5

llS 0.25 11 48 114 lOS

-0.68 10 48 5

14S 0.23 9

48 114 llS

-0.68 17 Page 39 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 48 114 115 0.39 7

49 24 085 0.34 12 48 115 095 0.36 11 49 26 095 0.36 7

48 115 105

-0.74 10 49 27 095 0.34 8

48 115 115

-0.7 15 49 28 085

-0.61 9

48 115 115 0.4 19 49 28 085 0.52 8

48 116 105

-0.7 8

49 28 095

-0.76 5

48 116 115

-0.68 19 49 30 085 0.38 8

48 116 115 0.43 8

49 31 085

-0.78 10 48 116 145

-0.84 9

49 31 085 0.38 17 48 116 145 0.32 18 49 32 085 0.36 7

48 120 105

-0.7 10 49 32 095 0.34 8

48 120 105 0.39 22 49 35 095 0.4 7

48 120 115

-0.65 22 49 69 085 0.39 6

48 120 115 0.39 12 49 71 085 0.39 7

48 120 125

-0.7 21 49 74 085 0.43 9

48 121 125

-0.7 14 49 77 085 0.47 9

48 121 125 0.44 16 49 84 085

-0.77 6

49 2

105

-0.73 9

49 85 085

-0.73 9

49 2

115 0 0.76 12 49 89 085

-0.78 7

49 2

145

-0.74 9

49 92 085

-0.7 8

49 2

145 0.17 13 49 92 085 0.41 12 49 3

145 0.23 10 49 92 095

-0.77 6

49 4

105

-0.77 10 49 93 085

-0.73 7

49 4

14S

-0.83 9

49 95 08S 0.38 9

49 4

145 0.2 20 49 96 085 0.41 11 49 5

105 0.31 18 49 113 095

-0.61 7

49 5

155 0.18 13 49 113 115 0.41 20 49 6

115 0.27 20 49 114 115

-0.72 12 49 6

155 0.16 21 49 114 11S 0.41 27 49 8

115 0.27 8

49 115 095 0.36 9

49 9

095 0.36 13 49 115 105

-0.68 10 49 9

115 0.29 7

49 115 115 0.38 21 49 10 095 0.38 9

49 116 105

-0.7 12 49 16 095 0.39 6

49 116 105 0.38 12 49 19 095 0.34 7

49 116 115 0.43 11 49 21 09$

0.38 11 49 116 125 0.38 12 49 23 085

-0.76 10 49 117 105

-0.66 10 49 23 085 0.38 11 49 120 105

-0.7 18 49 23 095 0.32 7

49 120 105 0.38 21 49 24 08S

-0.72 8

49 120 115

-0.65 18 Page 40 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 49 120 11S 0.45 13 50 92 07S 0.56 8

49 120 12S

-0.68 13 50 92 08S

-0.76 7

49 122 12S

-0.7 22 50 92 08S 0.4 19 50 3

14S 0.18 10 50 96 08S 0.38 10 50 4

15S 0.2 7

50 98 08S 0.34 18 50 5

11S 0.32 12 50 100 08S 0.34 9

50 5

15S 0.18 8

50 101 08S 0.38 6

50 6

14S 0.16 8

50 114 09S 0.38 9

50 6

15S 0.23 8

50 114 11S 0.41 13 50 7

11S 0.34 7

50 115 10S

-0.66 9

50 7

15S 0.16 16 50 116 10S 0.34 19 50 8

11S 0.32 7

50 116 11S

-0.65 14 50 9

09S 0.34 18 50 116 11S 0.34 28 50 10 09S 0.36 8

50 117 11S 0.38 19 50 14 09S 0.36 7

50 118 11S 0.4 19 50 21 09S 0.34 8

50 119 10S

-0.65 14 50 22 09S 0.29 7

50 119 11S 0.45 12 50 26 09S 0.36 7

51 1

12S

-0.71 15 50 27 09S

-0.77 5

51 1

12S 0.42 14 50 28 08S 0.36 11 51 2

14S 0.17 14 50 30 07S 0.56 9

51 4

14S 0.18 13 50 30 08S

-0.78 13 51 5

14S 0.18 13 50 31 09S 0.34 6

51 9

11S

-0.83 7

50 32 08S 0.36 7

51 9

11S 0.32 14 50 33 08S 0.38 7

51 10 09S 0.36 12 50 34 08S 0.4 13 51 10 11S 0.27 13 50 35 08S

-0.74 10 51 24 08S

-0.59 14 50 36 08S 0.4 13 51 24 09S

-0.81 12 50 45 08S 0.38 7

51 24 09S 0.34 9

50 46 08S

-0.76 10 51 26 09S 0.34 9

50 73 08S 0.45 6

51 28 08S

-0.76 13 50 75 08S 0.43 8

51 28 08S 0.38 10 50 82 08S

-0.71 28 51 28 09S

-0.67 8

50 83 08S

-0.7 16 51 28 09S 0.34 8

50 83 10S

-0.72 8

51 29 08S

-0.61 9

50 84 08S

-0.71 9

51 31 08S

-0.61 14 50 87 08S

-0.72 8

51 31 09S

-0.72 6

50 88 07S 0.58 10 51 35 08S 0.4 7

50 88 08S

-0.73 15 51 71 08S 0.38 9

50 88 08S 0.4 9

51 75 08S 0.41 9

Page 41 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 51 75 095

-0.79 6

52 4

145 0.25 9

51 77 085 0.43 9

52 5

145 0.16 8

51 79 065 0.56 8

52 7

115

-0.81 7

51 79 075

-0.76 10 52 7

155 0.2 8

51 79 075 0.41 18 52 9

115 0.25 16 51 79 085

-0.74 8

52 9

145

-0.86 10 51 79 085 0.43 7

52 9

145 0.14 7

51 79 095

-0.79 7

52 10 095 0.36 9

51 83 065 0.58 8

52 10 115 0.29 11 51 83 075 0.38 15 52 11 095 0.38 10 51 83 085

-0.72 17 52 23 095 0.36 6

51 84 085 0.41 14 52 24 095

-0.79 5

51 87 085

-0.69 17 52 25 095

-0.79 9

51 88 085 0.41 8

52 25 095 0.34 9

51 90 085 0.4 8

52 26 095 0.36 7

51 91 085 0.38 9

52 27 085 0.54 7

51 92 085 0.41 9

52 27 095

-0.7 11 51 97 085

-0.71 14 52 27 095 0.34 12 51 104 085

-0.58 10 52 29 095

-0.79 7

51 111 095

-0.67 13 52 29 095 0.34 12 51 112 115 0.38 13 52 31 095

-0.72 13 51 113 095 0.4 13 52 31 095 0.38 7

51 114 115 0.43 11 52 33 085 0.4 8

51 115 115 0.4 23 52 34 085 0.32 6

51 116 115 0.36 10 52 36 085 0.38 7

51 117 105

-0.65 10 52 42 085

-0.72 8

51 117 115 0.34 10 52 42 08S 0.31 7

51 118 105

-0.68 9

52 44 085 0.4 8

51 118 11S

-0.68 9

52 45 085

-0.76 14 51 118 115 0.47 7

52 46 08S

-0.74 12 51 118 125

-0.68 19 52 87 08S

-0.74 7

51 120 11S

-0.7 8

52 88 07S

-0.63 7

51 120 11S 0.41 16 52 88 085

-0.73 7

51 120 12S

-0.61 14 52 88 09S

-0.76 6

51 120 12S 0.39 12 52 89 075

-0.74 10 52 1

105

-0.73 13 52 89 07S 0.43 8

52 2

10S

-0.74 12 52 89 08S

-0.7 14 52 2

11S 0.27 10 52 89 08S 0.43 12 52 3

14S

-0.79 7

52 90 08S 0.4 7

52 3

145 0.14 13 52 91 085 0.36 9

Page 42 of 85

TMI-1 Steam Generator Tube Inspection Report (Tl R22), Exhibit 1 SG B~ Broached TSP-Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 52 93 08S 0.41 10 53 116 11S 0.25 14 52 95 08S 0.34 7

53 117 10S

-0.7 15 52 100 08S

-0.76 13 53 117 11S

-0.75 8

52 104 08S 0.53 9

53 117 11S 0.38 23 52 106 08S 0.58 9

53 118 11S 0.43 10 52 116 09S 0.38 7

53 119 10S

-0.7 9

52 116 11S 0.4 10 53 119 11S

-0.75 8

52 117 11S 0.39 16 53 119 11S 0.41 12 52 118 11S 0.36 29 53 120 10S

-0.61 28 52 119 11S 0.41 9

53 120 11S

-0.72 12 52 122 11S

-0.65 11 53 120 11S 0.4 24 53 1

10S

-0.76 10 53 120 12S

-0.65 13 53 2

10S

-0.74 11 53 120 12S 0.43 9

53 3

09S 0.32 10 53 121 10S

. 0.4 7

53 6

11S

-0.77 10 53 121 11S

-0.69 8

53 8

10S

-0.79 8

53 121 11S 0.45 21 53 8

14S 0.2 9

53 121 12S

-0.72 13 53 9

11S 0.29 7

53 121 15S 0.43 13 53 10 09S 0.38 11 53 122 08S 0.41 8

53 12 14S

-0.9 9

53 122 10S

-0.72 9

53 14 08S 0.56 8

53 122 12S

-0.68 12 53 21 09S 0.36 7

53 123 12S

-0.73 15 53 24 09S 0.38 9

53 124 12S

-0.7 12 53 26 08S

-0.63 10 54 1

125 0.39 23 53 26 09S 0.29 9

54 1

13S

-0.76 12 53 30 08S 0.49 12 54 2

12S

-0.71 8

53 32 09S 0.38 7

54 5

12S 0.34 11 53 34 09S 0.38 7

54 6

14S 0.18 13 53 35 08S 0.36 8

54 7

10S

-0.74 15 53 36 08S 0.36 10 54 7

14S 0.23 6

53 37 08S 0.38 8

54 8

11S

-0.79 10 53 43 07S

-0.56 16 54 9

11S

-0.75 8

53 43 085

-0.74 8

54 10 11S

-0.7 14 53 50 08S 0.4 11 54 10 13S 0.2 7

53 51 08S

-0.74 8

54 10 14S 0.14 9

53 80 08S

-0.76 7

54 10 15S 0.16 10 53 84 08S 0.43 6

54 24 07S 0.52 6

53 89 07S

-0.61 9

54 24 09S 0.34 9

53 89 08S

-0.72 10 54 25 09S 0.34 5

53 89 08S 0.34 10 54 26 09S

-0.74 7

Page43 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 54 26 09S 0.34 6

55 6

11S

-0.81 13 54 27 09S 0.36 7

55 8

11S

-0.72 11 54 29 09S 0.34 7

55 9

095 0.38 13 54 32 08S 0.34 12 55 9

155 0.18 9

54 32 095 0.32 7

55 10 09S 0.39 8

54 34 095 0.38 7

55 10 145

-0.88 5

54 40 085 0.36 8

55 10 155 0.18 8

54 42 085 0.43 7

55 15 115 0.29 8

54 58 085

-0.7 9

55 15 145

-0.83 7

54 58 08S 0.45 10 55 18 15S

-0.95 7

54 58 095

-0.7 16 55 31 08S 0.36 7

54 92 08S

-0.76 9

55 40 085

-0.76 10 54 92 085 0.36 12 55 40 085 0.4 8

54 97 085 0.4 12 55 42 085 0.38 6

54 98 085

-0.73 7

55 43 08S 0.38 12 54 104 08S 0.49 8

55 44 085 0.43 6

54 107 085 0.36 10 55 45 085 0.4 13 54 109 085

-0.74 9

55 46 08S

-0.74 11 54 109 09S 0.36 8

55 55 085 0.41 9

54 119 115 0.43 7

55 85 075

-0.73 11 54 120 115 0.41 13 55 87 08S 0.42 16 54 122 10S 0.34 17 55 117 115 0.39 10 54 122 11S

-0.68 36 55 118 105

-0.7 11 54 122 11S 0.36 32 55 118 11S 0.39 12 54 122 12S

-0.68 17 55 119 10S

-0.7 13 54 122 12S 0.36 13 55 120 10S

-0.7 8

54 122 13S

-0.7 14 55 120 11S 0.41 8

54 123 10S

-0.68 19 55 121 10S

-0.7 10 54 123 11S 0.41 10 55 122 09S

-0.66 8

54 123 12S

-0.7 8

55 122 10S

-0.7 21 54 124 10S

-0.68 11 55 122 10S 0.38 8

54 125 12S

-0.7 12 55 122 11S

-0.66 8

55 1

14S 0.2 12 55 122 11S 0.43 21 55 2

105

-0.74 9

55 123 105

-0.7 15 55 3

11S

-0.72 13 55 123 10S 0.32 11 55 4

11S

-0.77 11 55 123 115

-0.66 8

55 4

14S 0.16 7

55 123 11S 0.43 27 55 5

11S

-0.79 16 55 124 105

-0.68 22 55 5

14S

-0.88 7

55 124 115

-0.68 7

55 5

14S 0.2 9

55 124 11S 0.45 15 Page44 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment

  • Row Tube TSP Offset TW Comment 55 124 125

-0.7 7

56 123 125 * -0.7 15 55 126 125

-0.7 10 56 123 125 0.38 11 56 2

115

-0.73 9

56 123 155 0.41 7

56 3

145 0.2 8

56 124 105 0.16 12 56 4

115

-0.75 12 56 124 115

-0.71 9

56 5

095

-0.66 7

56 125 125

-0.7 9

56 5

115

-0.81 9

56 126 115

-0.7 11 56 5

145

-0.86 5

56 126 125

-0.75 18 56 5

145 0.2 9

56 127 125

-0.73 18 56 6

115

-0.77 12 57 3

115

-0.75 17 56 7

115

-0.75 10 57 3

125 0.38 13 56 8

095 0.38 9

57 5

145 0.2 8

56 8

155 0.11 11 57 8

155 0.18 8

56 9

095 0.34 7

57 9

115

-0.75 11 56 10 095 0.36 11 57 9

145 0.16 9

56 11 155 0.18 6

57 11 155 0.18 10 56 19 095 0.36.

8 57 13 155 0.18 7

56 21 095 0.36 7

57 31 065

-0.74 9

56 31 095 0.36 7

57 31 095

-0.78 9

56 32 085

-0.74 12 57 31 095 0.36 8

56 32 085 0.38 14 57 34 095 0.34 4

56 34 085

-0.76 9

57 35 095 0.36 7

56 35 085

-0.79 12 57 38 085

-0.72 16 56 35 085 0.29 14 57 38 085 0.38 9

56 37 075 0.58 10 57 40 085

-0.76 8

56 37 085 0.38 7

57 40 085 0.4 9

56 44 085

-0.72 8

57 51 085

-0.74 16 56 44 085 0.45 9

57 88 085 0.45 11 56 45 085

-0.74 9

57 101 085 0.38 13 56 45 085 0.4 11 57 107 085 0.36 10 56 73 085

-0.74 8

57 119 115 0.36 16 56 89 085 0.45 10 57 122 105

-0.68 8

56 97 085 0.38 15 57 123 105

-0.72 12 56 99 085 0.38 18 57 124 105 0.32 21 56 107 085

-0.76 8

57 124 125 0.3 11 56 110 085 0.38 6

57 125 105

-0.66 16 56 111 085 0.36 10 57 125 105 0.41 8

56 123 105 0.41 11 57 125 115

-0.66 15 56 123 115

-0.7 11 57 125 115 0.41 13 56 123 115 0.43 19 57 125 125

-0.7 12 Page45 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 57 125 12S 0.38 10 59 26 09S 0.34 5

57 126 10S

-0.68 7

59 28 09S 0.32 5

57 127 10S

-0.68 14 59 29 09S 0.34 8

58 1

10S

-0.73 14 59 31 09S

-0.76 9

58 1

11S

-0.71 13 59 31 09S 0.38 8

58

  • 2 12S

-0.74 9

59 32 09S 0.36 7

58 3

11S

-0.81 5

59 39 08S 0.38 6

58 3

11S 0.34 9

59 40 08S 0.43 12 58 5

14S 0.23 7

59 87 08S 0.41 7

58 7

14S 0.2 7

59 102 08S 0.38 10 58 11 14S

-0.86 8

59 106 08S 0.38 9

58 14 15S 0.16 7

59 107 08S 0.38 6

58 15 15S 0.16 8

59 108. 08S 0.43 14 58 24 09S 0.38 8

59 110 10S

-0.81 12 58 25 09S 0.36 5

59 124 10S

-0.72 18 58 30 09S 0.38 6

59 124 10S 0.38 7

58 32 09S 0.31 8

59 124 11S

-0.68 15 58 38 08S

-0.74 11 59 124 11S 0.38 31 58 105 06S

-0.76 7

59 124 13S

-0.7 11 58 105 06S 0.45 10 59 126 10S

-0.7 15 58 105 07S 0.51 9

59 126 11S 0.43 8

58 105 08S 0.38 10 60 4

11S

-0.7 14 58 105 09S

-0.81 10 60 6

115 0.29 13 58 106 085

-0.76 14 60 7

15S

-0.89 9

58 106 08S 0.38 13 60 14 15S 0.16 8

58 107 085 0.43 16 60 17 09S 0.34 7

58 108 08S

-0.76 7

60 23 09S 0.36 8

58 108 08S 0.34 11 60 31 085

-0.63 9

58 112 08S 0.38 14 60 36 08S 0.4 8

58 112 095

-0.7 8

60 41 08S 0.36 7

58 113 08S 0.4 11 60 105 08S

-0.76 9

58 125 10S

-0.61 8

60 108 08S

-0.72 10 58 125 10S 0.43 10 60 108 08S 0.41 11 58 125 11S

-0.71 19 60 110 08S 0.36 7

58 125 115 0.36 21 60 112 085 0.38 7

58 127 10S

-0.66 11 60 124 105

-0.72 9

58 127 11S 0.38 8

60 126 105

-0.68 10 59 5

14S 0.18 8

60 126 115 0.41 16 59 19 09S 0.38 8

60 127 105

-0.63 14 59 24 08S 0.52 7

60 127 115 0.43 14 Page46 of 85

TM!-I Steam Generator Tube Inspection Report (Tl R22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 60 129 11S

-0.7 13 62 121 11S 0.36 9

60 129 12S

-0.75 12 62 122 11S

-0.7 13 61 2

11S

-0.71 9

62 123 10S

-0.68 20 61 3

11S 0.27 11 62 123 10S 0.36 9

61 5

11S

-0.72 8

62 123 11S

-0.7 10 61 5

15S 0.2 10 62 123 11S 0.41 26 61 7

15S 0.11 14 62 124 10S

-0.68 15 61 32 08S 0.56 7

62 124 11S 0.43 12 61 102 08S 0.41 11 62 125 10S

-0.67 14 61 105 08S

-0.74 9

62 125 11S

-0.72 8

61 112 08S

-0.72 13 62 125 11S 0.43 13 61 112 10S

-0.77 9

62 127 10S

-0.7 18 61 113 07S 0.56 14 62 127 11S

-0.75 15 61 113 08S

-0.76 9

62 127 11S 0.32 16 61 114 08S 0.38 11 63 2

14S

-0.74 10 61 126 11S 0.43 7

63 4

09S 0.34 7

61 127

  • 10S

-0.59 9

.63 5

09S 0.36 10 61 127 11S 0.43 8

63 5

11S 0.27 22 61 128 10S

-0.68 18 63 30 09S 0.38 6

61 130 04S

-0.65 10 63 38 08S 0.36 9

62 1

11S

-0.71 15 63 41 08S 0.38 10 62 1

14S 0.22 11 63 45 08S 0.4 17 62 4

11S

-0.77 9

63 96 08S

-0.76 6

62 11 14S

-0.91 9

63 97 08S

-0.69 14 62 23 08S 0.5 6

63 102 08S 0.43 7

62 24 08S 0.52 11 63 107 08S

-0.78 10 62 28 08S 0.36 10 63 123 10S

-0.63 8

62 29 09S 0.36 6

63 123 11S 0.32 23 62 30 09S 0.34 12 63 124 10S

-0.68 10 62 32 08S

-0.72 22 63 124 11S 0.41 7

62 32 08S 0.38 11 63 125 10S 0.36 10 62 34 08S 0.38 10 63 125 11S

-0.72 15 62 40 08S 0.4 10 63 125 11S 0.36 11 62 98 09S

-0.81 6

63 126 09S 0.41 8

62 99 08S 0.34 11 63 126 10S

-0.68 11 62 100 08S 0.4 10 63 126 10S 0.34 9

62 102 08S 0.36 11 63 126 11S

-0.77 6

62 107 08S

-0.74 8

63 126 11S 0.36 12 62 113 08S 0.38 10 63 126 12S

-0.68 8

62 113 09S 0.36 10 63 128 11S 0.41 7

Page 47 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 63 129 125

-0.73 10 65 126 115 0.41 8

64 1

135

-0.74 12 65 127 115 0.39 16 64 2

135

-0.78 10 65 130 115

-0.73 20 64 4

125

-0.75 17 65 130 115 0.32 17 64 4

125 0.32 15 65 130 125

-0.73 18 64 20 095 0.32 7

66 3

125 0.36 13 64 40 085

-0.74 18 66 4

095 0.52 6

64 44 085 0.4 12 66 4

125

-0.75 18 64 98 095 0.4 12 66 4

125 0.29 26 64 102 085 0.4 9

66 4

135

-0.81 8

64 103 085 0.38 7

66 6

145 0.2 8

64 104 085

-0.74 16 66 7

145 0.18 7

64 104 085 0.43 20 66 11 155 0.16 5

64 105 085

-0.67 8

66 23 095 0.36 10 64 105 085 0.38 7

66 26 095 0.34 8

64 110 085 0.4 9

66 29 095 0.36 6

64 110 095 0.34 9

66 38 085

-0.72 9

64 110 105

-0.81 11 66 85 035

-0.63 7

64 125 105

-0.72 12 66 109 085

-0.78 9

64 125 115 0.38 27 66 109 085 0.38 8

64 125 145

-0.81 6

66 110 085 0.38 9

64 126 115 0.41 7

66 112 085 0.29 11 64 128 115

-0.68 11 66 112 105

-0.81 4

64 129 125 0.29 13 66 124 115 0.39 12 65 8

145 0.23 8

66 126 105

-0.68 34 65 14 155 0.14 8

66 126 115 0.39 15 65 28 085 0.47 9

66 129 115

-0.73 22 65 28 095 0.38 8

66 129 115 0.39 13 65 31 095 0.38 8

66 129 125

-0.73 15 65 35 085

-0.77 12 66 129 125 0.27 11 65 35 085 0.36 8

66 129 135

-0.7 12 65 42 085 0.41 13 67 1

105

-0.76 10 65 44 085

-0.72 18 67 1

115

-0.74 12 65 68 065 0.56 6

67 1

145

-0.76 11 65 68 095

-0.74 9

67 1

145 0.15 11 65 68 095 0.47 7

67 2

125

-0.74 11 65 121 105

-0.79 10 67 2

125 0.32 11 65 124 105

-0.68 7

67 3

145 0.2 10 65 124 105 0.39 9

67 4

125

-0.77 6

65 124 115 0.39 7

67 4

125 0.29 15 Page 48 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 67 5

11S 0.27 8

68 127 095 0.41 11 67 7

12S

-0.75 10 68 127 115 0.38 14 67 7

14S 0.23 11 68 128 10S

-0.7 10 67 11 15S 0.16 7

68 128 11S 0.39 10 67 30 09S 0.36 7

68 129 10S

-0.7 37 67 31 08S 0.38 14 68 131 11S

-0.73 24 67 33 07S 0.59 11 68 131 12S

-0.75 11 67 33 08S

-0.72 31 69 1

12S

-0.76 10 67 33 085 0.34 17 69 9

14S 0.16 8

67 38 08S 0.43 10 69 21 155 0.11 9

67 39 085

-0.77 9

69 28 09S 0.36 8

67 40 085 0.43 7

69 33 08S

-0.72 13 67 60 085

-0.72 14 69 33 085 0.4 12 67 111 08S 0.36 7

69 35 08S 0.4 10 67 111 10S

-0.74 6

69 42 08S

-0.7 16 67 125 095 0.41 10 69 42 08S 0.38 9

67 125 115 0.36 18 69 99 08S 0.43 8

67 125 13S

-0.86 8

69 113 065 0.43 7

67 126 10S

-0.68 22 69 113 08S

-0.76 16 67 126 11S 0.41 7

69 113 09S

-0.72 12 67 127 105

-0.65 28 69 113 09S 0.36 7

67 127 115 0.41 8

69 113 105

-0.79 10 67 129 105

-0.73 24 69 114 085 0.36 21 67 129 115

-0.73 21 69 116 085

-0.69 12 67 129 11S 0.29 10 69 126 09S 0.43 7

67 130 12S

-0.68 14 69 127 09S 0.45 9

68 1

145 0.22 11 69 127 105

-0.72 10 68 6

115 0.25 16 69 127 115 0.38 8

68 13 155 0.11 11 69 128 105

-0.7 9

68 27 095 0.32 9

69 128 115 0.39 13 68 29 09S 0.36 9

69 129 105

-0.68 20 68 32 08S 0.38 8

69 129 115 0.41 12 68 41 085

-0.72 15 69 131 10S

-0.68 13 68 49 085

-0.7 9

69 131 11S

-0.73 20 68 93 08S

-0.79 9

69 132 115

-0.73 19 68 112 085

-0.74 14 69 132 12S

-0.7 12 68 113 08S

-0.76 12 70 1

12S 0.32 8

68 114 085

-0.74 10 70 2

12S 0.32 11 68 114 095 0.38 6

70 2

13S

-0.76 12 68 126 11S 0.36 8

70 3

13S

-0.75 10 Page 49 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 70 4

125

-0.74 13 71 9

145

-0.88 10 70 4

135

-0.77 15 71 34 08S 0.43 12 70 5

105 0.38 7

71 100 OBS 0.4 17 70 5

12S

-0.75 12 71 100 09S 0.38 9

70 7

11S

-0.81 7

71 101 085 0.4 9

70 8

14S 0.14 7

71 102 08S 0.42 8

70 12 15S 0.11 10 71 104 08S 0.42 10 70 19 09S 0.34 7

71 104 095

-0.8 8

70 21 09S 0.36 9

71 105 085

-0.79 6

70 22 095 0.34 8

71 106 OBS

-0.78 7

70 23 08S 0.32 13 71 107 08S 0.43 9

70 23 09S 0.29 8

71 126 105 0.36 8

70 24 08S 0.39 14 71 126 115 0.36 13 70 26 09S 0.34 6

71 127 09S 0.29 12 70 27 OBS 0.45 9

71 127 105

-0.74 12 70 27 09S 0.34 9

71 127 11S

-0.77 9

70 28 085 0.52 9

71 127 11S 0.34 12 70 30 08S 0.34 11 71 127 125

-0.72 10 70 44 OBS

-0.79 6

71 128 04S

-0.63 12 70 111 08S

-0.76 7

71 128.10S

-0.7 12 70 111 08S 0.38 8

71 129 10S

-0.72 7

70 125 11S 0.34 9

71 130 125

-0.75 8

70 126 115 0.36 15 71 131 10S

-0.7 30 70 127 105

-0.68 17 71 131 11S

-0.7 18 70 127 11S 0.32 12 71 132 12S

-0.7 11 70 128 105

-0.68 20 72 1

115

-0.71 15 70 128 11S 0.38 12 72 1

14S 0.17 7

70 129 105

-0.7 7

72 2

135

-0.73 19 70 130 11S

-0.7 15 72 3

12S 0.23 10 71 1

115

-0.78 12 72 3

13S

-0.84 6

71 1

12S

-0.76 11 72 5

10S

-0.74 5

71 1

13S

-0.76 17 72 6

125

-0.83 15 71 4

12S

-0.7 8

72 6

13S

-0.86 9

71 5

10S 0.52 10 72 7

12S

-0.79 15 71 5

125

-0.91 9

72 7

13S

-0.86 6

71 5

125 0.52 20 72 8

12S

-0.79 13 71 6

12S

-0.79 6

72 9

14S 0.16 6

71 7

12S

-0.83 12 72 10 145

-0.92 9

71 7

13S

-0.86 12 72 20 OBS 0.38 12 71 7

14S 0.47 15 72 26 09S 0.36 6

Page 50 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 72 30 08S 0.38 9

73 6

11S

-0.72 14 72 42 08S 0.43 8

73 6

11S 0.27 16 72 45 08S

-0.72 11 73 7

11S

-0.81 9

72 102 08S 0.45 9

73 7

12S

-0.85 9

72 105 08S 0.41 6

73 8

09S 0.38 8

72 109 08S 0.43 8

73 10 09S 0.38 7

72 110 10S

-0.81 6

73 11 09S 0.34 7

72 111 08S

-0.74 7

73 15 15S 0.16 12 72 111 08S 0.4 12 73 20

  • 15S

-0.97 7

72 113 08S

-0.76 11 73 38 08S

-0.74 9

72 113 08S 0.36 12 73 38 08S 0.38 6

72 113 09S

-0.74 6

73 101 07S 0.45 8

72 124 10S

-0.72 11 73 101 08S

-0.7 18 72 124 11S 0.34 7

73 105 08S

-0.76 9

72 125 10S

-0.7 11 73 110 07S 0.56 14 72 126 09S 0.45 12 73 110 08S

-0.74 12 72 126 10S

-0.41 9

73 110 08S 0.38 10 72 126 11S

-0.81 9

73 120 11S 0.31 8

72 126 11S 0.29 18 73 122 10S

-0.77 8

72 127 09S 0.36 10 73 122 11S 0.34 7

72 127 10S

-0.7 15 73 124 10S

-0.7 9

72 127 10S 0.36 9

73 126 09S 0.36 8

72 127 11S 0.32 17 73 126 10S

-0.75 8

72 127 12S

-0.75 7

73 126 10S 0.36 10 72 128 10S

-0.7 12 73 126 11S

-0.75 7

72 128 11S

-0.75 7

73 127 10S

-0.72 12 72 129 10S

-0.7 6

73 127 11S

-0.72 11 72 130 10S

-0.7 12 73 128 10S

-0.73 21 73 1

11S

-0.83 8

73 129 11S 0.36 12 73 1

12S

-0.71 10 73 131 10S

-0.7 15 73 1

12S 0.3 11 73 131 10S 0.36 10 73 2

11S

-0.76 11 73 131 11S

-0.73 15 73 2

13S

-0.78 9

73 132 12S

-0.68 12 73 3

12S 0.3 16 74 2

12S 0.29 11 73 3

13S

-0.82 9

74 2

13S

-0.76 10 73 4

12S

-0.79 6

74 3

12S

-0.79 6

73 4

12S 0.32 7

74 3

13S

-0.82 8

73 4

13S

-0.79 5

74 4

10S

-0.79 8

73 5

13S

-0.79 7

74 4

12S

-0.79 15 73 5

14S 0.18 9

74 4

13S

-0.84 11 Page 51 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment

  • 74 5

125

-0.75 12 75 116 085

-0.76 9

74 5

125 0.32 7

75 126 115 0.34 9

74 6

125

-0.78 8

75 127 105

-0.67 10 74 6

135

-0.84 12 75 127 115 0.34 13 74 8

135

-0.84 8

75 128 105

-0.65 9

74 8

145 0.18 11 75 129 105

-0.67 31 74 9

145 0.14 6

75 130 105

-0.67 8

74 10 105 0.32 10 76 2

125 0.29 8

74 13 105

-0.82 6

76 4

125

-0.81 8

74 38 085

-0.73 16 76 5

115

-0.81 10 74 104 085

-0.78 7

76 5

115 0.32 7

74 105 085 0.43 5

76 6

125

-0.79 9

74 107 085 0.38 11 76 9

105

-0.72 11 74 110 085

-0.79 7

76 17 155 0.14 9

74 115 085

-0.74 8

76 97 085 0.45 6

74 116 085

-0.75 9

76 101 085 0.43 8

74 124 105

-0.68 13 76 124 115 0.34 19 74 126 115 0.29 15 76 125 105

-0.7 23 74 127 105

-0.7 12 76 126 105

-0.72 34 74 129 105

-0.69 8

76 127 105

-0.74 12 74 131 115

-0.75 21 76 128 105

-0.7 26 75 3

125 0.27 14 76 128 115

-0.75 9

75 3

135

-0.8 7

76 128 115 0.44 6

75 4

125

-0.77 11 76 129 105

-0.72 11 75 5

125

-0.79 9

76 129 115

-0.77 20 75 6

115

-0.72

10.

76 129 135

-0.84 11 75 7

125

-0.81 10 77 1

115

-0.78 12 75 7

125 0.23 8

77 1

135

-0.76 19 75 7

135

-0.82 10 77 1

145

-0.76 10 75 10 145 0.16 7

77 1

145 0.17 12 75 17 095 0.36 8

77 2

115

-0.78 9

75 33 085 0.4 13 77 5

125

-0.84 7

75 37 085 0.4 11 77 6

095 0.34 7

75 45 08S

-0.78 13 77 6

11S 0.27 12 75 95 08S

-0.68 7

77 6

14S 0.2 10 75 97 08S 0.43 6

77 6

155 0.14 8

75 99 08S 0.45 10 77 7

125

-0.86 6

75 101 085

-0.74 5

77 7

15S

-0.92 5

75 111 09S 0.38 7

77 15 09S 0.38 10 75 114 08S

-0.74 9

77 18 09S 0.36 4

Page 52 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 77 22 08S 0.34 12 79 25 09S 0.36 9

77 101 08S 0.4 9

79 101 07S 0.56 8

77 104 08S 0.39 7

79 101 08S

-0.74 8

77 104 09S

-0.77 7

79 101 08S 0.43 8

77 106 08S

-0.72 10 79 102 04S 0.47 7

77 106 09S

-0.79 7

79 102 06S

-0.54 8

77 108 08S 0.41 6

79 102 09S 0.38 6

77 108 09S 0.36 7

79 102 10S

-0.81 6

77 127 09S 0.38 7

79 104 08S 0.41 9

77 127 10S

-0.7 14 79 106 08S 0.38 9

77 128 10S

-0.68 38 79 109 08S 0.38 11 77 131 10S

-0.7 22 79 122 11S 0.32 11 77 131 11S

-0.73 8

79 127 10S

-0.7 15 78 1

13S

-0.76 23 79 128 10S

-0.72 16 78 2

13S

-0.76 17 79 128 13S 0.29 6

78 3

13S

-0.73 17 79 131 10S

-0.7 19 78 7

14S 0.2 6

79 131 12S

-0.83 6

78 8

14S

-0.91 8

79 132 10S

-0.72 11 78 11 09S 0.36 7

79 132 12S

-0.79 7

78 22 09S 0.29 5

80 2

13S

-0.74 9

78 106 08S

-0.78 5

80 4

11S

-0.73 13 78 108 08S 0.4 7

80 4

11S 0.27 16 78 113 07S 0.53 8

80 9

10S

-0.79 7

78 113 08S

-0.76 10 80 12 09S 0.36 5

78 113 08S 0.4 9

80 19 09S 0.36 8

78 113 09S

-0.72 12 80 20 08S 0.43 6

78 114 08S

-0.72 7

80 22 08S 0.52 6

78 126 10S

-0.75 17 80 22 09S 0.32 5

78 127 10S

-0.7 39 80 100 07S 0.52 6

78 128 10S

-0.68 14 80 100 08S 0.34 7

78 128 11S 0.34 12 80 103 08S

-0.76 8

78 130 10S

-0.7 14 80 103 08S 0.4 7

78 131 10S

-0.67 41 80 107 08S 0.43 7

78 131 11S

-0.72 16 80 113 08S

-0.76 11 79 1

13S

-0.83 11 80 114 08S

-0.74 9

79 1

14S

-0.91 9

80 114 09S

'-0.79 4

79 1

14S 0.15 8

80 115 08S

-0.74 10 79 4

12S

-0.73 12 80 126 10S

-0.72 17 79 5

15S 0.16 7

80 127 10S

-0.7 23 79 8

10S

-0.73 9

80 128 10S

-0.68 33 Page 53 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 80 130 10S

-0.7 10 82 116 08S

-0.74 7

80 131 11S

-0.82 11 82 126 10S

-0.73 8

80 131 11S 0.39 9

82 126 10S 0.32 13 81 4

14S

-0.93 7

82 127 10S

-0.73 22 81 5

14S

-0.88 6

82 128 09S 0.43 7

81 6

14S

-0.86 8

82 128 10S

-0.7 13 81 7

09S 0.39 8

82 129 10S

-0.65 15 81 7

14S

-0.75 10 82 130 10S

-0.7 16 81 7

14S 0.23 8

82 130 12S

-0.73 7

81 9

10S

-0.7 10 82 131 12S

-0.87 12 81 15 09S 0.34 8

83 1

14S

-0.88 11 81 16 09S 0.34 8

83 1

14S 0.12 10 81 17 08S 0.52 9

83 2

13S

-0.84 8

81 17 09S 0.36 11 83 2

14S

-0.76 10 81 26 09S 0.36 5

83 3

13S

-0.77 13 81 31 08S

-0.71 10 83 3

14S

-0.75 8

81 38 08S 0.38 10 83 6

09S 0.41 9

81 103 08S 0.4 8

83 6

10S 0.39 7

81 106 08S 0.38 7

83 8

14S 0.14 7

81 109 08S 0.45 7

83 24 08S 0.49 8

81 110 08S 0.41 12 83 108 08S

-0.74 6

81 128 10S

-0.7 33 83 109 08S

-0.74 7

81 128 11S 0.32 9

83 109 08S 0.4 16 81 128 12S

-0.77 12 83 110 07S 0.56 6

81 128 12S 0.27 14 83 110 08S

-0.74 10 81 128 13S

-0.75 11 83 110 08S 0.38 11 81 128 14S

-0.27 13 83 111 08S

-0.74 9

81 130 10S

-0.68 13 83 112 08S

-0.74 8

81 132 10S 0.43 14 83 113 08S

-0.74 9

81 132 13S 0.29 22 83 114 08S

-0.72 8

82 1

14S

-0.78 12 83 116 08S

-0.74 10 82 5

09S 0.39 8

83 127 10S 0.36 11 82 5

14S 0.2 15 83 128 10S

-0.7 18 82 6

09S 0.39 6

83 128 13S 0.32 8

82 6

14S 0.18 11 83 129 10S

-0.7 15 82 7

14S 0.14 8

83 130 10S

-0.7 10 82 33 08S

-0.76 8

83 132 12S 0.27 13 82 106 08S 0.41 6

84 1

13S

-0.76 21 82 109 08S 0.38 15 84 2

13S

-0.76 19 82 110 08S 0.38 7

84 5

09S 0.41 10 Page 54 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 84 5

11S 0.25 8

85 125 09S 0.43 9

84 5

14S

-0.86 8

85 125 11S 0.34 11 84 8

14S

-0.91 8

85 126 10S 0.39 10 84 27 08S 0.47 6

85 127 10S

-0.72 17 84 29 08S

-0.77 9

85 129 10S

-0.72 23 84 29 08S 0.36 6

85 130 12S

-0.77 10 84 40 08S 0.42 7

85 130 12S 0.29 17 84 98 08S 0.43 7

86 1

14S 0.22 11 84 102 08S 0.43 8

86 2

14S

-0.79 10 84 103 08S 0.41 8

86 3

13S

-0.79 9

84 106 08S 0.38 8

86 5

09S 0.39 8

84 108 07S 0.43 8

86 5

13S

-0.84 7

84 108 08S

-0.78 7

86 6

13S

-0.84 10 84 108 08S 0.38 18 86 7

14S 0.18 12 84 127 09S 0.41 10 86 34 07S 0.53 16 84 127 10S

-0.7 18 86 107 08S

-0.76 5

84 127 11S 0.32 15 86 124 10S 0.36 9

84 128 10S

-0.7 32 86 126 10S

-0.73 11 84 128 13S

  • 0.27 8

86 128 10S

-0.7 11 84 129 10S

-0.68 12 87 2

10S

-0.73 7

84 131 09S 0.38 10 87 2

13S

-0.74 10 84 131 10S

-0.67 29 87 2

14S 0.15 9

85 1

12S

-0.71 9

87 3

10S

-0.77 7

85 2

13S

-0.74 19 87 4

09S 0.39 7

85 3

13S

-0.75 13 87 4

11S

-0.27 17 85 3

14S

-0.73 12 87 4

12S

-0.82 9

85 4

10S

-0.79 7

87 4

14S

-0.88 8

85 4

13S

-0.82 7

87 6

14S

-0.88 8

85 5

10S

-0.7 10 87 7

10S

-0.7 7

85 6

09S 0.39 6

87 16 09S 0.36 9

85 10 15S 0.18 8

87 19 09S 0.36 7

85 16 09S 0.34 7

87 21 09S 0.32 6

85 22 08S 0.49 7

87 27 08S 0.29 6

85 22 09S 0.36 7

87 28 08S 0.38 12 85 27 08S 0.34 7

87 103 08S 0.41 13 85 100 08S 0.41 6

87 104 08S 0.36 7

85 103 08S 0.4 13 87 127 09S 0.43 8

85 106 08S 0.41 5

87 127 10S

-0.69 20 85 109 08S

-0.76 8

87 127 13S 0.31 9

85 109 08S 0.31 9

87 128 10S

-0.68 15 Page 55 of 85

TMI-1 Steam Generator Tube Inspection Report (Tl R22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 87 129 10S 0.39 7

89 127 14S

-0.84 9

88 1

14S 0.27 9

89 128 10S

-0.7 13 88 3

12S

-0.75 11 89 129 10S

-0.73 11 88 3

13S

-0.86 11 89 129 10S 0.44 5

88 5

14S

-0.77 10 89 129 12S

-0.75 9

88 9

14S 0.18

  • 7 89 129 12S 0.32 7

88 29 08S

-0.76 7

89 130 10S

-0.65 17 88 102 08S

-0.76 6

90 3

11S 0.32 8

88 102 08S 0.38 11 90 5

09S

-0.7 17 88 103 08S 0.38 7

90 5

09S 0.41 10 88 104 08S 0.38 7

90 7

14S

-0.78 12 88 106 08S 0.38 6

90 13 15S 0.11 8

88 107 08S

-0.76 11 90 20 09S 0.34 7

88 107 08S 0.38 17 90 24 08S 0.54 7

88 114 08S

-0.69 7

90 30 08S

-0.72 12 88 115 08S

-0.71 9

90 30 08S 0.36 6

88 125 09S 0.39 9

90 32 08S

-0.7 11 88 126 10S

-0.68 20 90 48 08S

-0.76 7

88 126 10S 0.39 8

90 96 08S

-0.76 5

88 126 11S 0.27 9

90 96 08S 0.41 5

88 128 10S

-0.73 5

90 101 08S

-0.78 10 88 128 11S

-0.7 7

90 105 08S 0.38 10 89 1

13S

-0.74 32 90 106 08S

-0.76 10 89 1

14S

-0.78 15 90 106 08S 0.36 11 89 1

14S 0.25 12 90 106 09S

-0.79 6

89 3

11S

-0.75 12 90 106 10S

-0.81 6

89 3

11S 0.32 8

90 117 09S 0.41 7

89 4

14S 0.16 8

90 120 09S 0.41 6

89 5

09S

-0.68 13 90 124 14S

-0.82 8

89 15 09S 0.36 7

90 125 10S

-0.68 15 89 28 08S 0.36 14 90 125 13S 0.34 10 89 108 08S

-0.79 7

90 126 10S

-0.7 8

89 108 08S 0.38 7

90 126 10S 0.39 7

89 110 08S 0.32 7

90 127 10S

-0.67 26 89 110 09S 0.34 7

91 1

14S 0.22 18 89 111 09S 0.34 9

91 2

14S

-0.74 9

89 126 10S 0.34 9

91 6

09S

-0.7 8

89 127 09S 0.41 7

91 6

09S 0.38 8

89 127 10S

-0.7 20 91 6

10S 0.34 9

89 127 13S 0.34 10 91 6

14S

-0.91 8

Page 56 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 91 22 08S 0.54 9

92 110 08S

-0.78 8

91 28 08S

-0.61 7

92 126 09S 0.43 6

91 32 08S

-0.69 9

92 126 10S

-0.68 25 91 41 08S

-0.72 15 92 126 10S 0.41 7

91 101 08S

-0.72 9

92 128 10S

-0.68 10 91 101 08S 0.38 7

92 128 12S 0.27 8

91 101 09S

-0.75 8

92 128 13S 0.37 9

91 102 09S 0.36 9

92 128 14S

-0.8 10 91 102 10S

-0.79 11 93 1

13S

-0.74 20 91 104 08S 0.4 10 93 7

14S

-0.82 9

91 105 08S

-0.79 8

93 8

14S

-0.8 11 91 105 08S 0.38 6

93 9

13S

-0.84 11 91 106 08S

-0.76 9

93 9

13S 0.25 12 91 110 07S 0.56 10 93 9

14S 0.11 8

91 110 08S

-0.76 8

93 20 09S 0.36 6

91 110 08S 0.36 8

93 24 08S 0.54 12 91 110 09S 0.36 8

93 29 08S 0.54 16 91 113 08S

-0.72 7

93 29 09S

-0.8 6

91 126 10S

-0.73 10 93 30 08S 0.38 8

91 127 10S

-0.7 11 93 40 08S

-0.7 9

91 128 10S

-0.7 9

93 96 08S 0.39 7

91 129 10S

-0.7 9

93 97 08S 0.4 10 92 1

14S 0.22 16 93 98 08S 0.39 5

92 6

09S

-0.7 22 93 101 08S 0.38 8

92 6

10S 0.38 7

93 102 08S 0.41 6

92 22 08S

-0.61 10 93 103 08S 0.34 10 92 22 09S 0.34 7

93 106 08S

-0.74 7

92 23 08S 0.52 6

93 109 08S

-0.78 8

92 24 08S 0.54 11 93 125 10S

-0.63 12 92 41 08S

-0.72 16 93 126 10S

-0.68 10 92 41 08S 0.38 6

93 127 10S

-0.67 7

92 97 08S

-0.74 6

93 128 10S

-0.67 22 92 98 09S 0.38 7

93 128 12S

-0.82 10 92 99 05S

-0.67 6

94 3

13S

-0.72 14 92 99 08S

-0.72 7

94 3

13S 0.39 17 92 99 08S 0.41 7

94 8

14S

-0.75 13 92 102 08S 0.38 12 94 24 08S 0.34 10 92 103 08S

-0.72 8

94 25 08S 0.34 10 92 104 08S

-0.74 10

  • 94 29 08S

-0.7 10 92 107 08S

-0.76 8

94 35 08S 0.29 6

Page 57 of 85

TMI-1 Steam Generator Tube Inspection Report (Tl R22)

Attachment I, Exhibit I SG 8/ Broached TSP Wear Indications Sized by Bobbin Probe/ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 94 38 08S 0.38 9

96 7

14S

-0.84 6

94 40 08S

-0.71 10 96 7

14S 0.16 7

94 40 08S 0.42 10 96 22 09S 0.32 7

94 43 08S

-0.72 8

96 44 08S

-0.71 10 94 97 08S 0.41 6

96 45 08S

-0.72 11 94 98 08S 0.4 12 96 48 08S

-0.73 8

94 99 08S 0.38 14 96 90 08S 0.43 9

94 102 08S 0.34 12 96 91 08S 0.39 5

94 106 08S

-0.76 10 96 92 08S

-0.78 9

94 126 09S

-0.7 6

96 98 08S 0.4 10 94 126 10S

-0.68 13 96 105 07S 0.54 5

94 126 10S 0.43 17 96 112 09S 0.34 7

94 128 10S

-0.63 16 96 117 09S 0.41 8

95 1

13S

-0.71 24 96 121 09S

-0.67 11 95 3

13S

-0.72 23 96 122 09S

-0.68 6

95 3

13S 0.39 11 96 122 10S 0.43 11 95 3

14S

-0.79 11 96 123 09S 0.4 10 95 5

09S

-0.72 13 96 123 14S

-0.78 8

95 25 08S 0.38 10 96 124 09S

-0.68 6

95 35 08S 0.31 8

96 124 09S 0.41 8

95 36 08S

-0.72 10 96 124 10S

-0.7 7

95 38 08S 0.38 6

96 124 10S 0.43 7

95 43 08S 0.38 13 96 125 10S

-0.71 26 95 56 085

-0.74 11 96 125 10S 0.4 8

95 57 08S

-0.74 13 96 125 13S 0.36 9

95 97 085 0.43 12 96 126 10S

-0.65 6

95 100 08S 0.41 11 96 126 12S

-0.73 10 95 105 08S

-0.76 10 96 127 10S

-0.67 26 95 107 08S

-0.74 11 96 127 12S

-0.73 11 95 122 10S 0.41 10 97 12 14S

-0.86 9

95 123 10S 0.41 9

97 12 14S 0.16 7

95 125 09S 0.41 9

97 91 08S

-0.74 6

95 126 10S

-0.7 16 97 95 08S 0.43 9

95 126 10S 0.43 8

97 97 08S 0.38 10 95 127 10S

-0.65 9

97 98 08S 0.4 8

95 127 12S

-0.73 12 97 104 08S

-0.7 33 95 128 10S

-0.7 12 97 104 09S

-0.79 6

95 128 14S

-0.78 12 97 105 08S

-0.74 7

96 4

09S 0.43 7

97 116 09S 0.4 8

96 4

10S 0.29 15 97 118 09S 0.41 10 Page 58 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG 8/ Broached TSP Wear Indications Sized by Bobbin Probe/ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 97 118 11S 0.25 7

98 99 08S 0.38 12 97 119 09S

-0.7 8

98 107 08S

-0.74 7

97 119 09S 0.43 19 98 109 08S

-0.74 8

97 119 10S

-0.67 9

98 116 09S 0.38 11 97 120 09S 0.4 15 98 116 10S 0.36 13 97 120 10S

-0.7 11 98 117 09S 0.36 14 97 120 11S 0.32 8

98 117 10S 0.38 12 97 121 09S

-0.67 14 98 118 09S 0.34 13 97 121 09S 0.43 9

98 118 10S

-0.7 31 97 121 10S

-0.72 23 98 119 09S 0.36 14 97 122 08S 0.43 5

98 119 10S

-0.7 16 97 122 09S

-0.68 11 98 120 10S

-0.74 12 97 122 09S 0.41 8

98 120 10S 0.42 8

97 122 10S

-0.7 13 98 120 13S 0.31 22 97 123 09S

-0.67 13 98 121 09S 0.43 10 97 123 09S 0.4 7

98 122 09S

-0.69 16 97 123 10S

-0.67 20 98 122 09S 0.38 15 97 123 10S 0.4 15 98 122 10S

-0.69 13 97 124 09S

-0.65 8

98 122 10S 0.45 5

97 124 09S 0.34 8

98 123 ass

-0.62 10 97 124 10S

-0.68 12 98 123 09S

-0.71 22 97 124 10S 0.39 8

98 123 09S 0.33 11 97 125 10S

-0.7 7

98 123 10S

-0.69 9

97 125 13S

-0.73 7

98 i23 11S

-0.71 13 97 125 13S 0.34 16 98 125 12S

-0.7 20 97 126 10S

-0.67 23 98 125 13S

-0.77 13 97 126 14S

-0.75 20 98 125 13S 0.36 20 98 2

12S

-0.68 7

98 125 14S

-0.8 19 98 2

13S

-0.81 9

99 3

09S

-0.7 15 98 3

09S

-0.68 16 99 20 09S 0.36 7

98 12 14S 0.2 7

99 21 15S 0.11 12 98 13 14S 0.16 9

99 34 08S

-0.76 5

98 20 15S 0.09 8

99 40 08S

-0.76 6

98 24 09S 0.34 6

99 95 08S 0.38 15 98 35 08S 0.31 9

99 97 08S 0.38 12 98 65 08S 0.45 8

99 98 08S 0.39 10 98 96 08S 0.41 8

99 99 08S

-0.79 7

98 97 08S 0.43 14 99 99 08S 0.38 14 98 98 08S

-0.72 7

99 101 08S 0.41 15 98 98 08S 0.36 10 99 108 14S 0.16 6

Page 59 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment], Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 99 109 08S

-0.72 9

100 22 08S

-0.56 10 99 109 09S 0.36 7

100 24 08S 0.34 7

99 115 09S 0.43 10 100 26 08S

-0.7 10 99 115 10S 0.31 8

100 27 08S

-0.76 12 99 116 09S 0.43 10 100 28 09S 0.34 8

99 116 10S

-0.7 10 100 32 08S

-0.76 10 99 116 10S 0.36 7

100 32 08S 0.38 4

99 117 10S

-0.74 16 100 91 08S 0.41 11 99 118 10S

-0.72 17 100 92 08S 0.38 6

99 118 10S 0.38 9

100 94 08S 0.41 8

99 119 09S 0.43 8

100 96 08S

-0.79 5

99 119 10S

-0.72 31 100 97 08S

-0.78 9

99 120 09S 0.47 8

100 97 08S 0.38 8

99 120 10S

-0.69 31 100 98 08S

-0.77 6

99 120 10S 0.42 7

100 100 07S

-0.5 9

99 121 09S 0.42 19 100 101 08S 0.38 13 99 121 10S

-0.71 10 100 102 08S

-0.74 11 99 121 10S 0.42 9

100 107 08S

-0.74 7

99 121 13S 0.34 10 100 114 09S 0.4 9

99 122 10S

-0.71 17 100 114 10S 0.38 6

99 122 10S 0.4 9

100 115 09S 0.38 9

99 123 09S 0.34 16 100 115 10S

-0.69 14 99 124 10S

-0.67 20 100 115 10S 0.33 9

99 124 13S 0.39 10 100 116 10S

-0.69 26 99 124 14S

-0.8 15 100 118 09S 0.38 13 100 1

12S

-0.74 13 100 119 10S

-0.69 26 100 2

14S

-0.73 11 100 120 09S 0.38 8

100 3

09S

-0.72 14 100 120 10S

-0.71 19 100 3

11S 0.29 6

100 122 10S

-0.68 6

100 3

14S

-0.86 10 101 1

14S

-0.83 13 100 3

14S 0.18 9

101 2

14S

-0.78 8

100 4

14S

-0.82 25 101 3

10S 0.36 17 100 4

14S 0.23 8

101 3

14S

-0.73 15 100 4

15S

-0.84 23 101 4

14S

-0.77 25 100 4

15S 0.2 31 101 4

14S 0.25 11 100 5

14S

-0.77 21 101 4

15S

-0.72 31 100 5

14S 0.14 14 101 4

15S 0.14 36 100 7

14S

-0.86 9

101 5

14S

-0.8 32 100 20 08S

-0.61 8

101 5

14S 0.23 24 100 21 09S 0.36 8

101 5

15S

-0.86 23 Page 60 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment I, Exhibit I SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 101 5

15S 0.18 27 101 120 13S 0.36 18 101 22 06S 0.38 5

102 2

14S

-0.76 11 101 22 08S

-0.7 14 102 3

11S

-0.75 10 101 22 09S

-0.72 8

102 3

11S 0.27 10 101 22 09S 0.34 7

102 3

14S

-0.73 16 101 23 08S 0.54 10 102 4

14S

-0.77 25 101 24 08S 0.36 8

102 4

14S 0.25 19 101 26 08S 0.34 9

102 4

15S

-0.77 19 101 31 08S 0.38 8

102 4

15S 0.14 27 101 32 08S 0.38 7

102 17 09S 0.36 8

101 38 08S

-0.74 7

102 41 08S

-0.77 10 101 83 07S 0.39 13 102 41 09S

-0.8 7

101 83 08S

-0.75 9

102 52 08S 0.45 7

101 83 08S 0.39 9

102 83 08S 0.32 7

101 89 08S

-0.77 8

102 85 08S

-0.72 12 101 89 08S 0.38 6

102 88 08S 0.41 10 101 92 08S 0.34 8

102 89 08S

-0.72 11 101 94 08S

-0.74

'8 102 92 08S 0.38 7

101 96 08S 0.29 10 102 93 08S 0.38 6

101 97 08S

-0.76 7

102 94 08S

-0.77 6

101 98 08S

-0.76 8

102 94 08S 0.38 8

101 98 08S 0.36 8

102 113 09S 0.4 7

101 102 08S

-0.74 8

102 113 10S

-0.69 11 101 102 08S 0.36 11 102 114 10S

-0.69 21 101 112 09S 0.4 8

102 115 10S

-0.73 13 101 113 10S

-0.69 14 102 116 09S 0.38 14 101 114 10S

-0.76 10 102 116 10S

-0.72 15 101 115 09S 0.38 12 102 118 10S

-0.69 19 101 116 09S 0.45 13 102 120 10S

-0.7 8

101 116 10S

-0.69 20 102 121 10S

-0.67 22 101 117 09S 0.53 8

102 121 12S

-0.75 16 101 117 10S

-0.73 14 103 1

14S

-0.81 19 101 117 12S

-0.74 10 103 1

14S 0.24 7

101 117 13S 0.34 14 103 2

13S

-0.71 7

101 118 10S

-0.69 25 103 2

14S

-0.76 7

101 118 10S 0.4 8

103 3

14S

-0.8 8

101 120 09S 0.41 8

103 4

11S

-0.75 13 101 120 10S

-0.72 26 103 4

14S

-0.82 25 101 120 10S 0.39 12 103 4

14S 0.27 12 101 120 12S

-0.73 13 103 5

14S

-0.75 20 Page 61 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 103 5

145 0.25 8

104 95 085 0.41 14 103 5

155

-0.84 13, 104 96 085 0.4 11 103 5

155 0.21 20 104 97 085 0.27 7

103 16 085 0.49 8

104 99 085

-0.74 5

103 23 095 0.34 5

104 99 085 0.38 9

103 41 085

-0.69 8

104 113 095 0.38 7

103 52 085 0.41 6

104 113 105

-0.72 15 103 75 085

-0.7 7

104 1.14 095 0.4 10 103 84 085 0.41 8

104 114 105

-0.72 17 103 90 085 0.38 10 104 115 095 0.56 10 103 91 085 0.36 8

104 115 105

-0.72 26 103 113 105 0.38 10 104 115 105 0.4 8

103 114 095 0.4 9

104 116 095 0.4 13 103 114 105

-0.72 34 104 117 095 0.54 7

103 114 135 0.29 13 104 117 105

-0.74 29 103 115 105

-0.71 13 104 117 135 0.27 11 103 115 135 0.31 9

104 120 105

-0.73 13 103 115 145

-0.85 8

104 120 105 0.46 7

103 116 095 0.38 13 104 121 105

-0.68 27 103 116 135 0.31 5

104 121 115

-0.73 18 103 117 095 0.56 11 104 121 125 0.29 12 103 117 105

-0.73 16 105 3

145 0

59 Array44% Max 103 119 105

-0.69 23 105 4

105

-0.72 12 103 120 105

-0.69 22 105 4

145

-0.82 21 104 1

135

-0.69 28 105 4

155 0.07 51 Array 34% Max 104 1

135 0.39 24 105 5

155 0.18 11 104 1

145

-0.81 17 105 23 095 0.36 5

104 1

145 0.25 8

105 36 085

-0.78 7

104 3

145

-0.84 13 105 39 085

-0.69 8

104 4

145

-0.84 9

105 39 085 0.41 6

104 5

155

-0.29 31 105 48 085

-0.79 8

104 44 085

-0.75 9

105 51 085 0.45 9

104 47 085

-0.72 8

105 81 085

-0.75 6

104 47 085 0.4 5

105 82 085 0.41 12 104 47 095 0.38 6

105 85 085

-0.7 10 104 84 075 0.56 9

105 87 085 0.41 8

104 84 085 0.41 12 105 90 085 0.41 10 104 89 085 0.43 9

105 91 085 0.39 10 104 90 085 0.4 11 105 92 085

-0.76 7

104 95 085

-0.74 6

105 92 085 0.41 9

Page 62 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 105 94 08S 0.34 10 106 116 09S 0.36 11 105 95 08S

-0.77 9

106 116 10S

-0.7 18 105 95 08S 0.38 10 106 116 10S 0.38 8

105 111 09S 0.38 14 106 117 10S

-0.7 26 105 111 10S

-0.7 17 106 119 10S

-0.72 23 105 112 10S

-0.74 9

106 119 13S 0.39 12 105 112 10S 0.41 7

107 2

14S

-0.73 15 105 113 10S

-0.74 20 107 6

10S 0.39 9

105 113 10S 0.41 13 107 33 08S 0.38 5

105 113 13S 0.32 10 107 36 08S

-0.73 8

105 115 10S

-0.7 26 107 42 08S

-0.79 8

105 116 10S

-0.69 26 107 42 08S 0.4 8

105 116 11S

-0.83 8

107 77 06S

-0.57 7

105 117 09S 0.43 5

107 77 085

-0.73 11 105 117 10S

-0.7 21 107 77 085 0.41 8

105 118 10S

-0.68 21 107 77 095 0.39 9

105 118 12S

-0.77 18 107 83 075 0.54 9

106 1

145

-0.78 17 107 83 085

-0.77 12 106 1

145 0.12 8

107 83 085 0.36 9

106 2

145

-0.73 10 107 86 085 0.4 9

106 3

145

-0.8 16 107 93 08S

-0.74 7

106 7

145

-0.84 10 107 112 095

-0.72 8

106 27 085 0.36 11 107 112 105

-0.7 16 106 39 08S

-0.69 8

107 113 09S

-0.77 11 106 44 08S

-0.77 8

107 113 095 0.38 16 106 82 085 0.41 8

107 113 105

-0.72 24 106 89 085 0.36 10 107 113 105 0.41 10 106 93 085

-0.77 6

107 114 095 0.4 8

106 93 085 0.38 9

107 114 105

-0.7 17 106 98 08S

-0.67 10 107 114 10S 0.38 4

106 112 095 0.41 12 107 115 105

-0.68 24 106 112 105

-0.72 11 107 117 105

-0.68 15 106 113 095

-0.7 11 107 117 10S 0.41 9

106 113 095 0.41 12 107 117 125 0.29 10 106 113 105

-0.72 14 108 1

145

-0.78 10 106 114 09S 0.41 9

108 3

145

-0.35 30 106 114 105

-0.72 18 108 4

105

-0.72 10 106 114 145

-0.9 8

108 4

155

-0.86 8

106 115 105

-0.7 19 108 4

155 0.18 9

106 115 10S 0.43 7

108 5

155 0.18 7

Page 63 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 108 10 14S

-0.86 10 109 23 08S 0.47 9

108 12 14S 0.18 8

109 32 08S

-0.76 8

108 28 08S

-0.69 18 109 39 08S 0.42 8

108 30 06S 0.4 4

109 41 08S

-0.75 13 108 30 08S

-0.71 13 109 50 08S 0.34 12 108 30 09S 0.34 10 109 75 08S

-0.7 12 108 38 08S

-0.76 6

109 79 08S 0.4 10 108 39 08S 0.38 9

109 82 08S 0.38 10 108 41 08S

-0.71 21 109 92 08S

-0.76 6

108 43 08S

-0.73 11 109 112 09S

-0.67 7

108 45 08S 0.38 6

109 112 10S

-0.74 14 108 87 08S 0.43 10 109 112 10S 0.32 12 108 92 08S

-0.71 10 109 112 11S

-0.74 8

108 92 08S 0.38 11 109 112 13S 0.31 10 108 111 10S 0.34 13 109 113 09S

-0.67 10 108 112 09S

-0.67 9

109 113 09S 0.4 7

108 112 10S

-0.74 10 109 113 10S 0.4 18 108 112 10S 0.36 8

109 114 09S 0.38 11 108 113 09S

-0.74 7

109 114 10S

-0.7 12 108 113 09S 0.43 7

109 114 10S 0.4 7

108 113 10S

-0.72 11 109 115 09S 0.44 7

108 113 10S 0.36 16 109 115 10S

-0.7 12 108 114 09S 0.43 8

109 116 10S

-0.68 9

108 114 10S 0.38 5

109 116 105 0.41 9

108 115 10S

-0.7 19 110 2

14S

-0.75 10 108 115 105 0.4 7

110 3

145

-0.79 9

108 116 10S

-0.68 15 110 36 085

-0.84 7

108 116 125

-0.73 7

110 63 085 0.42 8

108 117 105

-0.7 18 110 69 085

-0.72 11 108 117 115

-0.78 13 110 76 08S 0.41 8

108 117 12S 0.24 8

110 77 08S

-0.71 17 109 1

14S

-0.76 24 110 81 085 0.38 9

109 2

14S

-0.8 13 110 83 08S 0.38 11 109 3

14S

-0.82 12 110 84 08S

-0.77 6

109 4

09S

-0.68 13 110 84 085 0.38 18 109 12 14S

-0.84 10 110 86 07S 0.54 6

109 14 14S

  • 0.11 7

110 86 08S

-0.76 6

109 19 155

-0.85 14 110 86 085 0.36 17 109 19 155 0.11 10 110 86 09S

-0.81 5

109 23 085

-0.58 8

110 90 08S

-0.76 7

Page 64 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 110 109 09S

-0.68 11 111 115 10S

-0.65 35 110 109 10S

-0.68 17 111 115 10S 0.41 6

110 110 09S

-0.7 8

111 116 09S 0.39 15 110 110 09S 0.43 5

111 116 10S

-0.7 18 110 110 10S

-0.72 13 112 16 14S

-0.99 6

110 111 09S

-0.7 10 112 16 14S 0.16 6

110 111 09S 0.45 7

112 17 14S

-0.92 9

110 111 10S

-0.67 17 112 17 14S 0.16 7

110 111 10S 0.43 4

112 21 15S

-0.38 11 110 112 10S

-0.68 32 112 22 08S

-0.47 8

110 112 10S 0.39 6

112 38 08S 0.4 4

111 2

14S

-0.68 8

112 41 09S

-0.76 7

111 3

10S

-0.7 10 112 47 08S 0.38 8

111 15 09S 0.36 5

112 48 08S 0.38 9

111 34 08S

-0.73 9

112 49 08S

-0.71 9

111 34 08S 0.36 6

112 49 08S 0.36 6

111 44 08S

-0.71 6

112 55 08S

-0.73 8

111 45 08S 0.42 5

112 69 06S 0.56 5

111 69 08S 0.42 6

112 69 08S

-0.7 10 111 70 07S 0.41 7

112 69 08S 0.4 8

111 70 08S

-0.68 11 112 69 09S

-0.79 7

111 70 08S 0.38 11 112 71 08S

-0.69 10 111 71 OBS 0.41 6

112 71 08S 0.43 9

111 76 085

-0.7 13 112 75 OBS 0.38 16 111 76 08S 0.41 11 112 77 OBS 0.43 14 111 82 08S

-0.74 9

112 87 OBS

-0.78 10 111 82 08S 0.4 9

112 87 OBS 0.4 8

111 86 085 0.36 10 112 110 105 0.36 7

111 87 OBS

-0.76 6

112 111 10S 0.38 11 111 87 OBS 0.41 17 112 112 09S 0.38 7

111 90 OBS 0.38 11 112 112 10S

-0.7 11 111 107 09S 0.41 5

112 113 09S

-0.68 17 111 111 OBS 0.43 9

112 113 10S

-0.7 24 111 113 09S

-0.72 6

112 114 10S

-0.7 18 111 113 09S 0.41 7

112 114 12S

-0.73 9

111 113 10S

-0.7 11 112 115 09S 0.41 10 111 114 09S

-0.76 7

112 115 10S

-0.73 31 111 114 09S 0.4 7

112 115 10S 0.44 9

111 114 10S

-0.7 25 113 1

13S

-0.73 26 11;1.

114 10S 0.4 10 113 1

14S

-0.81 14 Page 65 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 113 1

14S 0.24 7

114 23 14S 0.13 11 113 4

12S

-0.79 9

114 51 08S

-0.74 8

113 7

13S

-0.81 8

114 52 08S

-0.78 5

113 15 14S

-0.81 9

114 63 08S

-0.7 8

113 15 14S 0.16 7

114 64 08S 0.38 7

113 26 08S

-0.67 7

114 66 08S

-0.8 7

113 26 08S 0.36 5

114 67 08S

-0.74 8

113 29 08S

-0.72 10 114 67 09S 0.38 6

113 37 08S 0.38 7

114 68 08S 0.4 12 113 38 08S 0.34 5

114 69 08S 0.38 7

113 39 08S

-0.69 9

114 75 08S 0.4 14 113 39 08S 0.34 12 114 76 07S 0.56 7

113 41 08S

-0.67 7

114 77 07S 0.54 12 113 47 08S

-0.72 9

114 77 08S 0.36 11 113 68 08S

-0.7 11 114 77 09S

-0.81 10 113 68 08S 0.43 7

114 79 08S 0.41 8

113 70 08S

-0.72 10 114 80 08S 0.39 7

113 71 09S 0.34 14 114 85 08S 0.38 12 113 72 08S

-0.72 9

114 109 09S

-0.7 14 113 72 08S 0.41 6

114 110 09S 0.38 12 113 76 08S 0.39 7

114 112 10S

. -0.7 10 113 77 07S 0.54 7

114 112 10S 0.36 5

113 79 08S

-0.76 7

114 113 09S 0.38 13 113 81 08S 0.36 10 114 113 10S

-0.72 18 113 86 08S 0.38 7

114 114 09S 0.41 7

113 110 09S 0.43 5

114 114 10S 0.39 6

113 110 10S 0.29 6

114 115 10S

-0.68 23 113 111 10S 0.36 18 114 115 10S 0.41 16 113 112 10S

-0.7 12 114 115 11S 0.29 19 113 113 10S 0.43 9

114 115 12S

-0.75 14 113 114 10S

-0.72 12 115 1

13S

-0.73 24 113 115 10S

-0.73 11 115 1

14S

-0.81 12 113 115 10S 0.44 7

115 2

13S

-0.73 10 113 116 10S

-0.75 20 115 3

14S

-0.84 7

113 116 10S 0.41 11 115 5

09S 0.41 5

114 3

13S 0.36 9

115 24 08S

-0.64 11 114 7

14S

-0.77 14 115 26 08S

-0.66 7

114 7

14S 0.2 8

115 27 08S

-0.72 12 114 22 14S

-0.97 10 115 28 08S

-0.75 10 114 22 14S 0.14 8

115 28 08S 0.35 14 Page 66 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 115 29 06S

-0.7 7

116 12 14S

-0.93 5

115 29 08S 0.36 7

116 22 15S 0.09 11 115 29 09S

-0.7 7

116 26 08S

-0.75 8

115 34 08S

-0.75 11 116 26 08S 0.35 5

115 37 08S 0.38 6

116 27 08S

-0.72 7

115 38 08S

-0.77 11 116 28 08S

-0.73 8

115 38 09S 0.35 8

116 29 08S

-0.74 8

115 40 08S 0.35 8

116 30 08S

-0.64 7

115 42 08S 0.37 9

116 31 08S

-0.74 9

115 47 08S

-0.77 8

116 32 08S

-0.79 9

115 55 08S

-0.74 12 116 33 08S

-0.7 12 115 56 08S

-0.74 8

116 34 08S

-0:77 10 115 57 08S

-0.74 9

116 35 08S 0.34 6

115 63 08S

-0.72 9

116 59 08S 0.43 7

115 63 08S 0.41 7

116 64 08S

-0.74 10 115 64 08S

-0.69 16 116 64 08S 0.4 7

115 65 08S

-0.78 5

116 66 08S 0.38 7

115 71 08S 0.41 17 116 68 08S

-0.71 16 115 75 08S 0.41 8

116 75 08S 0.41 9

115 77 08S 0.36 8

116 76 08S 0.38 15 115 79 08S

-0.74 7

116 77 08S 0.39 8

115 81 08S 0.36 16 116 78 08S 0.38 16 115 82 06S

-0.61 5

116 80 08S

-0.74 10 115 84 08S

-0.77 4

116 80 08S 0.38 18 115 85 08S 0.36 19 116 81 08S

-0.65 8

115 108 09S

-0.7 9

116 81 08S 0.39 20 115 109 09S 0.38 13 116 82 08S

-0.74 10 115 109 10S

-0.7 11 116 82 08S 0.4 13 115 110 10S

-0.72 7

116 83 07S 0.56 7

115 110 10S 0.34 11 116 83 08S

-0.7 6

115 111 10S

-0.7 24 116 83 08S 0.36 9

115 111 10S 0.38 8

116 83 09S

-0.7 7

115 112 09S 0.41 10 116 84 08S

-0.69 8

115 112 10S

-0.7 24 116 84 08S 0.38 14 115 113 09S 0.36 6

116 84 09S 0.36 8

115 113 10S

-0.75 5

116 107 09S 0.38 10 115 114 10S

-0.7 15 116 108 09S 0.38 8

116 2

12S

-0.76 9

116 108 10S

-0.7 8

116 2

13S

-0.73 8

116 108 10S 0.38 8

116 3

13S

-0.79 9

116 110 10S 0.41 8

Page 67 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 116 111 10S

-0.7 28 117 85 08S 0.36 19 116 112 09S 0.36 7

117 85 09S

-0.74 11 116 112 10S

-0.78 8

117 86 09S 0.36 5

116 112 10S 0.41 7

117 106 09S 0.36 5

116 112 11S

-0.73 12 117 107 10S 0.36 12 116 113 10S

-0.7 9

117 109 10S

-0.7 10 117 1

12S

-0.78 6

117 110 10S

-0.7 11 117 1

13S

-0.74 23 117 110 10S 0.44 9

117 2

12S

-0.78 9

117 110 11S

-0.68 12 117 3

12S

-0.73 8

117 111 13S 0.34 9

117 3

13S

-0.73 14 118 6

14S

-0.77 14 117 4

13S

-0.79 13 118 6

14S 0.11 9

117 16 09S 0.38 9

118 11 14S

-0.79 10 117 20 15S 0.16 10 118 11 14S 0.18 6

117 27 08S

-0.76 6

118 14 15S 0.16 7

117 28 08S

-0.76 10 118 19 15S 0.14 9

117 29 08S

-0.76 5

118 20 15S 0.14 9

117 33 08S

-0.74 11 118 24 08S 0.36 5

117 35 08S

-0.78 8

118 27 08S

-0.76 7

117 39 08S

-0.77 8

118 35 08S

-0.73 10 117 42 08S 0.38 5

118 35 08S 0.33 7

117 43 08S 0.39 7

118 36 08S 0.56 5

117 44 08S 0.34 8

118 40 08S

-0.72 8

117 46 08S

-0.77 8

118 43 08S

-0.77 9

117 48 ass 0.43 7

118 44 08S

-0.79 7

117 61 08S 0.38 8

118 44 08S 0.36 8

117 62 08S 0.41 8

118 45 08S

-0.72 9

117 64 08S

-0.77 9

118 51 08S

-0.77 9

117 64 08S 0.36 10 118 52 08S

-0.78 6

117 67 08S 0.4 8

118 57 08S

-0.74 6

117 68 08S

-0.79 4

118 59 08S 0.38 10 117 73 08S 0.38 12 118 62 08S

-0.78 9

117 74 08S 0.36 9

118 64 08S 0.4 10 117 75 08S 0.41 18 118 66 08S 0.43 9

117 76 08S 0.39 10 118 67 08S 0.38 15 117 77 08S 0.41 7

118 68 08S 0.41 9

117 78 08S

-0.75 6

118 69 08S 0.38 10 117 78 08S 0.39 12 118 70 08S 0.39 11 117 79 08S 0.36 14 118 71 08S

-0.79 8

117 85 08S

-0.69 12 118 71 08S 0.38 14 Page 68 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 118 72 085 0.39 16 119 72 085 0.36 10 118 73 085

-0.72 11 119 73 085

-0.72 8

118 73 085 0.38 18 119 73 085 0.38 10 118 81 085

-0.76 6

119 76 085

-0.72 5

118 82 085 0.36 6

119 76 085 0.34 7

118 83 085 0.38 10 119 82 085

-0.65 7

118 85 085 0.4 14 119 82 08S 0.38 11 118 105 105 0.34 8

119 103 09S 0.38 8

118 106 105

-0.72 9

119 103 105 0.29 10 118 106 105 0.32 9

119 104 095 0.41 9

118 108 105

-0.72 11 119 105 105

-0.68 8

118 110 105

-0.68 21 119 105 10S 0.38 5

119 2

135

-0.73 11 119 105 115

-0.81 10 119 6

115 0.3 11 119 107 105

-0.7 5

119 18 155 0.16 9

119 107 115

-0.66 6

119 25 085

-0.74 8

120 3

135 0.32 16 119 26 085

-0.67 8

120 4

145

-0.86 10 119 30 085

-0.76 7

120 5

105

-0.72 16 119 33 085

-0.76 10 120 5

105 0.36 12 119 35 08S 0.35 9

120 5

145

-0.77 13 119 35 095 0.35 6

120 6

10S

-0.72 12 119 36 085

-0.76 8

120 6

13S 0.29 10 119 36 085 0.36 8

120 6

145

-0.77 12 119 38 06S

-0.58 6

120 8

145

-0.88 11 119 38 085

-0.76 8

120 8

145 0.16 6

119 38 085 0.36 7

120 16 155 0.18 8

119 41 075 0.53 6

120 20 155

-0.42 15 119 42 085

-0.76 11 120 22 095 0.38 8

119 44 085

-0.77 8

120 25 085

-0.79 7

119 44 085 0.38 6

120 29 08S 0.33 9

119 47 085

-0.79 6

120 30 085

-0.76 7

119 57 085 0.41 12 120 32 085

-0.79 7

119 58 085 0.41 8

120 33 085

-0.76 10 119 64 085

-0.74 6

120 35 085

-0.67 7

119 66 085 0.39 6

120 36 085 0.38 10 119 68 085 0.36

  • 9 120 43 085

-0.77 11 119 69 085 0.38 13 120 43 085 0.38 10 119 70 085

-0.72 5

120 43 095

-0.81 15 119 70 085 0.39 6

120 44 085 0.41 5

119 72 085

-0.77 6

120 44 095

-0.81 9

Page 69 of 85

TMI-1 Steam Generator Tube1nspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 120 45 08S

-0.76 6

121 30 08S

-0.76 10 120 47 08S

-0.74 7

121 30 08S 0.31 8

120 51 08S

-0.76 8

121 31 08S

-0.76 5

120 51 08S 0.4 8

121 32 08S

-0.76 9

120 52 08S 0.36 7

121 33 08S

-0.56 7

120 53 08S 0.43 7

121 34 08S

-0.73 10 120 55 08S 0.4 9

121 35 08S

-0.65 7

120 59 08S

-0.78 6

121 36 08S

-0.78 10 120 62 08S 0.41 5

121 37 08S

-0.76 6

120 67 08S

-0.61 7

121 43 08S

-0.77 16 120 70 08S 0.34 14 121 44 08S 0.36 8

120 71 08S 0.38 11 121 48 08S

-0.76 6

120 75 08S 0.38 7

121 48 08S 0.38 7

120 76 08S 0.38 13 121 57 08S

-0.77 7

120 77 08S

-0.7 11 121 63 08S

-0.74 6

120 78 09S

-0.7 6

121 63 08S 0.38 7

120 79 08S

-0.71 16 121 65 08S 0.36 8

120 79 08S 0.38 20 121 66 08S 0.36 15 120 79 09S

-0.74 16 121 67 08S 0.39 9

120 80 08S

-0.68 9

121 69 08S 0.41 8

120 98 09S 0.41 6

121 71 08S

-0.74 7

120 99 09S 0.38 8

121 72 08S 0.31 9

120 99 10S 0.29 12 121 76 07S 0.56 9

120 100 095 0.32 6

121 76 08S 0.38 12 120 100 10S 0.36 6

121 77 08S

-0.73 9

120 104 10S

-0.7 11 121 82 09S 0.36 6

121 4

10S

-0.7 11 121 101 10S 0.29 6

121 5

14S

-0.79 12 121 105 10S

-0.73 29 121 6

09S 0.36 8

121 106 11S 0.27 12 121 6

13S 0.32 14 122 1

10S

-0.68 7

121 7

13S 0.27 17 122 2

12S

-0.76 14 121 8

14S

-0.82 14 122 2

13S

-0.78 12 121 8

14S 0.18 8

122 4

14S

-0.88 8

121 11 14S 0.2 9

122 6

09S 0.36 6

121 14 14S

-0.88 9

122 6

13S

-0.86 7

121 14 14S 0.2 8

122 8

14S

-0.86 10 121 20 14S

-0.87 8

122 9

14S

-0.74 11 121 22 14S

-0.96 7

122 10 11S 0.27 9

121 22 14S 0.18 7

122 13 14S 0.22 7

121 29 085

-0.74 7

122 16 14S

-0.86 10 Page 70 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 122 16 14S 0.18 8

122 100 10S 0.38 5

122 17 15S 0.18 6

122 104 10S

-0.7 20 122 30 08S

-0.65 7

123 2

12S

-0.76 15 122 31 08S

-0.78 10 123 2

13S

-0.75 19 122 32 08S

-0.67 7

123 4

13S

-0.77 14 122 33 08S

-0.78 10 123 6

13S 0.27 9

122 34 08S

-0.74 8

123 7

13S 0.27 21 122 35 08S

-0.78 11 123 7

14S

-0.83 9

122 36 08S

-0.78 9

123 8

14S

-0.79 8

122 46 08S 0.36 6

123 9

14S

-0.34 15 122 46 09S

-0.75 8

123 13 14S

-0.83 9

122 51 08S

-0.78 6

123 13 14S 0.22 8

122 52 08S 0.38 9

123 15 14S

-0.36 14 122 53 08S 0.43 9

123 16 14S 0.2 7

122 55 08S

-0.76 7

123 20 09S

-0.65 6

122 56 08S

-0.76 9

123 30 08S

-0.7 7

122 56 08S 0.41 8

123 31 08S

-0.78 9

122 59 08S

-0.78 7

123 32 08S

-0.67 8

122 62 08S 0.36 10 123 33 08S

-0.76 10 122 63 07S 0.54 7

123 34 08S

-0.76 8

122 63 08S

-0.76 7

123 35 08S

-0.75 8

122 63 08S 0.38 11 123 37 08S

-0.75 10 122 64 08S

-0.76 6

123 38 08S

-0.78 6

122 64 08S 0.38 7

123 39 07S 0.55 9

122 65 07S 0.58 9

123 39 08S

-0.8 12 122 65 08S 0.36 11 123 39 08S 0.38 16 122 71 08S 0.38 13 123 39 09S

-0.82 20 122 75 08S

-0.7 12 123 46 08S 0.38 7

122 76 07S 0.55 5

123 48 08S

-0.76 12 122 76 08S

-0.69 13 123 48 08S 0.36 10 122 76 08S 0.36 11 123 51 08S

-0.74 7

122 76 09S

-0.74 13 123 53 08S

-0.74 9

122 76 09S 0.36 6

123 53 08S 0.41 10 122 80 07S 0.51 6

123 55 08S

-0.81 6

122 80 08S

-0.68 15 123 57 08S 0.38 13 122 80 08S 0.38 12 123 58 08S 0.38 11 122 80 09S

-0.78 10 123 60 08S 0.36 8

122 97 09S d.41 7

123 61 08S

-0.76 8

122 99 10S 0.34 9

123 61 08S 0.38 17 122 99 12S

-0.86 8

123 62 08S 0.38 8

Page 71 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 123 64 OBS 0.36 8

124 95 09S 0.41 6

123 73 OBS

-0.75 12 124 95 14S 0.23 6

123 97 09S 0.39 7

124 102 lOS

-0.7 14 123 103 09S 0.39 8

124 102 12S 0.29 10 123 103 lOS

-0.7 19 124 103 12S 0.2 9

123 104 12S 0.29 13 125 1

12S

-0.78 9

124 1

13S

-0.83 11 125 1

13S

-0.78 11 124 2

12S

-0.86 8

125 5

13S

-0.83 9

124 3

lOS

-0.73 6

125 6

13S 0.27 17 124 3

13S

-0.8 12 125 7

lOS

-0.72 13 124 7

09S 0.38 6

125 7

13S

-0.84 8

124 7

14S

-0.86 13 125 8

09S 0.34 9

124 7

14S 0.18 10 125 8

14S

-0.77 11 124 8

09S 0.38 9

125 9

14S

-0.79 11 124 10 14S 0.14 8

125 9

14S 0.11 8

124 11 14S

-0.79 12 125 11 14S

-0.88 7

124 11 14S 0.16 6

125 13 14S

-0.79 9

124 21 14S 0.75 7

125 13 14S 0.14 5

124 23 15S 0.16 5

125 19 14S 0.2 7

124 29 OBS

-0.63 7

125 42 OBS

-0.76 7

124 31 OBS

-0.76 15 125 48 OBS

-0.78 6

124 32 OBS

-0.8 7

125 48 OBS 0.36 10 124 33 OBS

-0.69 11 125 49 OBS

-0.76 6

124 34 08S

-0.73 12 125 50 08S

-0.76 8

124 35 OBS

-0.74 14 125 50 08S 0.36 13 124 35 08S 0.36 7

125 53 OBS 0.36 7

124 36 08S

-0.69 9

125 55 OBS

.:o.n 9

124 37 OBS

-0.76 8

125 55 08S 0.34 7

124 38 08S

-0.73 11 125 56 08S

-0.78 8

124 38 08S 0.35 10 125 57 OBS

-0.69 7

124 41 OBS

-0.76 8

125 57 08S 0.36 8

124 41 OBS 0.38 6

125 59 07S 0.58 5

124 41 09S

-0.83 11 125 59 OBS

-0.74 10 124 49 OBS

-0.76 8

125 59 08S 0.34 12 124 52 08S

-0.8 7

125 62 OBS

-0.74 13 124 58 OBS

-0.76 8

125 62 OBS 0.4 9

124 60 OBS.

0.4 9

125 62 09S

-0.81 9

124 70 08S

-0.71 15 125 63 08S

-0.78 6

124 93 14S

-0.77 13 125 64 OBS

-0.75 12 124 94 14S 0.18 8

125 75 08S

-0.75 9

Page 72 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 125 93 09S 0.41 10 127 32 08S

-0.78 9

125 95 14S

-0.75 11 127 41 07S 0.55 11 125 100 13S 0.22 18 127 41 08S

-0.79 14 125 101 10S

-0.73 25 127 41 08S 0.33 13 125 101 12S

-0.95 10 127 42 08S

-0.77 9

126 1

12S

-0.78 11 127 43 08S

-0.79 10 126 1

13S

-0.78 16 127 43 08S 0.35 8

126 5

13S 0.27 15 127 44 08S 0.35 8

126 6

13S 0.27 10 127 45 08S

-0.77 8

126 8

09S 0.38 10 127 so 08S

-0.79 9

126 8

13S 0.29 14

.127 51 08S

-0.79 7

126 27 08S

-0.67 8

127 61 08S

-0.78 8

126 29 08S

-0.69 8

127 61 08S 0.38 13 126 31 08S

-0.65 7

127 67 08S

-0.75 14 126 32 08S

-0.76 9

127 68 08S

-0.67 9

126 33 08S

-0.76 10 127 90 09S 0.38 9

126 34 08S

-0.77 9

127 97 09S 0.39 10 126 35 08S

-0.69 13 127 97 12S

-0.85 6

126 36 08S

-0.75 15 128 4

13S 0.29 17 126 45 08S

-0.69 8

128 7

10S

-0.75 18 126 46 08S

-0.76 10 128 7

14S

-0.77 17 126 47 08S

-0.78 8

128 11 14S 0.23 10 126 53 08S

-0.75 8

128 20 14S 0.2 8

126 59 08S 0.39 6

128 28 085

-0.7 7

126 65 08S

-0.74 21 128 30 08S

-0.69 7

126 66 09S 0.36 8

128 31 08S

-0.78 9

126 69 08S 0.38 10 128 33 08S

-0.77 10 126 85 14S

-0.88 7

128 35 08S

-0.73 11 126 90 09S 0.38 10 128 35 09S 0.35 9

126 90 14S

-0.84 8

128 36 08S

-0.79 8

126 92 10S 0.25 10 128 37 08S

-0.77 8

126 98 13S 0.32 12 128 41 08S

-0.79 6

127 1

13S

-0.81 10 128 46 08S

-0.78 10 127 5

14S

-0.86 12 128 46 08S 0.37 8

127 9

14S

-0.79

.13 128 47 08S

-0.78 9

127 10 14S

-0.86 9

128 so 07S 0.55 7

127 11 14S

-0.77 12 128 so 08S

-0.74 10 127 11 14S 0.14 13 128 so 08S 0.35 13 127 26 09S 0.4 7

128 51 08S

-0.7 14 127 30 08S

-0.76 9

128 51 08S 0.4 11 Page 73 of 85

TM!-! Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 128 52 08S

-0.79 7

129 65 08S

-0.73 12 128 52 08S 0.35 5

129 84 09S 0.36 11 128 53 08S

-0.72 21 129 86 10S 0.27 15 128 53 08S 0.42 15 129

.93 12S 0.24 6

128 54 08S

-0.73 13

  • 129 93 13S 0.22 18 128 55 08S

-0.78 11 129 93 14S

-0.8 8

128 59 08S

-0.73 11 129 94 11S 0.19 11 128 61 08S

-0.67 13 130 1

09S

-0.73 10 128 63 08S

-0.8 9

130 7

13S 0.2 6

128 64 08S

-0.76 13 130 8

09S 0.32 10 128 84 10S 0.36 8

130 9

09S

-0.7 7

128 87 11S

-0.72 11 130 9

09S 0.38 6

128 90 13S 0.27 17 130 13 14S

-0.77 11 128 91 09S 0.29 12 130 14 14S 0.23 16 128 91 13S 0.29 9

130 15 14S 0.23 7

129 1

12S

-0.81 10 130 21 14S

-0.77 9

129 9

09S 0.36 8

130 21 14S 0.23 8

129 9

14S

-0.72 17 130 51 08S

-0.78 8

129 9

14S 0.14 9

130 52 08S

-0.74 8

129 11 14S

-0.74 15 130 62 08S

-0.74 7

129 12 14S

-0.79 13 130 85 10S 0.34 11 129 12 14S 0.16 7

130 91 12S

-0.83 13 129 13 14S

-0.88 13 130 91 12S 0.27 14 129 14 14S 0.18 9

130 91 13S

-0.73 19 129 19 14S 0.25 8

130 91 13S 0.27 23 129 29 14S

-0.79 11 130 93 09S

-0.68 10 129 33 14S 0.16 6

131 1

12S

-0.83 10 129 34 14S

-0.89 7

131 1

13S

-0.76 25 129 34 14S 0.16 9

131 1

13S 0.34 12 129 43 08S

-0.72 8

131 3

13S

-0.82 6

129 45 08S

-0.69 6

131 7

09S 0.32 10 129 46 08S

-0.79 8

131 8

09S

-0.72 18 129 48 08S

-0.79 10 131 8

09S 0.34 16 129 48 08S 0.35 8

131 12 14S

-0.77 16 129 49 08S

-0.73 6

131 12 14S 0.14 7

129 51 08S

-0.76 7

131 17 14S 0.23 8

129 52 08S

-0.79 13 131 18 14S

-0.85 12 129 54 08S 0.4 7

131 18 14S 0.07 10 129 55 08S

-0.71 8

131 19 14S

-0.83 13 129 55 08S 0.36 7

131 19 14S 0.18 7

Page 74 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 131 21 145

-0.83 9

132 87 125

-0.76 11 131 25 145 0.23 10 132 87 125 0.27 13 131 29 085

-0.67 7

132 87 135

-0.76 11 131 30 085

-0.78 9

132 87 135 0.22 19 131 31 155

-0.77 9

132 88 135

-0.76 11 131 49 085

-0.69 6

132 88 135 0.24 11 131 so 085

-0.76 9

132 89 135

-0.73 12 131 53 085

-0.76 6

133 1

125

-0.81 13 131 55 085

-0.69 7

133 1

135

-0.76 15 131 82 105 0.29 13 133 1

135 0.29 13 131 82 115

-0.72 15 133 8

095 0.32 13 131 88 115

-0.84 9

133 9

095

-0.72 12 131 89 095 0.39 7

133 80 105 0.36 9

131 89 125

-0.85 8

133 80 145

-0.88 8

131 89 125 0.27 7

133 80 145 0.2 7

131 89 135

-0.76 17 133 86 095 0.39 15 131 89 135 0.27,

17 133 86 115 0.27 12 131 90 115 0.19 11 133 86 125

-0.78 10 132 1

135

-0.91 11 133 86 135

-0.73 18 132 6

105

-0.72 8

133 86 135 0.32 13 132 6

135 0.29 14 133 87 095 0.24 14 132 7

095 0.39 7

134 1

135

-0.79 23 132 7

135 0.29 8

134 7

095

-0.72 23 132 8

095

-0.7 12 134 7

095 0.34 13 132 8

095 0.38 20 134 8

095

-0.72 14 132 15 145

-0.77 13 134 8

095 0.36 11 132 15 145 0.23 7

134 12 145

-0.83 9

132 17 145

-0.86 12 134 14 145

-0.86 10 132 21 145 0.18 13 134 19 145

-0.74 13 132 23 145 0.2 13 134 22 145

-0.83 11 132 27 155 0.16 10 134 22 145 0.22 8

132 28 095 0.72 8

134 27 145

-0.81 11 132 31 085

-0.78 9

134 28 145

-0.8 14 132 36 155 0.16 9

134 34 155 0.16 9

132 45 085

-0.77 9

134 39 085

-0.73 8

132 58 085

-0.78 7

134 45 085

-0.77 16 132 81 105 0.34 9

134 75 145 0.16 6

132 81 115

-0.72 10 134 76 145 0.2 13 132 82 105 0.29 15 134 77 145

-0.9 9

132 84 115

-0.74 11 134 79 105 0.36 9

Page 75 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 134 80 10S 0.29 18 136 13 14S

-0.77 6

134 83 12S 0.24 11 136 14 14S

-0.86 8

134 83 13S

-0.81 14 136 16 14S

-0.88 7

134 83 13S 0.32 7

136 17 14S

-0.77 10 134 84 09S 0.39 11 136 21 14S

-0.66 15 134 84 11S 0.32 18 136 28 14S

-0.8 11 134 84 12S 0.32 11 136 28 14S 0.2 7

134 84 13S

-0.78 16 136 30 14S 0.2 11 134 84 13S 0.32 17 136 32 14S

-0.79 12 134 85 09S

-0.73 10 136 43 14S 0.2 13 135 1

09S 0.39 7

136 58 14S

-0.85 10 135 8

09S

-0.7 19 136 58 14S 0.2 6

135 8

09S 0.38 12 136 61 14S 0.18 9

135 9

09S

-0.75 10 136 63 09S 0.41 7

135 22 14S 0.25 8

136 63 14S

-0.88 8

135 28 14S

-0.81 11 136 65 09S 0.41 8

135 28 14S 0.18 8

136 65 14S

-0.86 7

135 38 14S

-0.81 16 136 75 10S 0.39 10 135 38 14S 0.2 8

136 76 10S 0.38 14 135 43 14S 0.13 7

136 77 09S 0.41 7

135 45 14S 0.16 7

136 77 10S 0.43 6

135 48 14S 0.72 7

136 81 12S 0.27 10 135 48 15S 0.11 7

136 81 13S 0.27 9

135 54 15S

-0.97 8

137 1

09S

-0.71

.9 135 54 15S 0.18 10 137 6

13S

-0.72 18 135 56 15S 0.18 10 137 6

13S 0.41 11 135 73 14S 0.23 8

137 7

09S 0.39 7

135 78 09S 0.36 10 137 8

09S

-0.74 10 135 78 10S 0.36 18 137 8

09S 0.38 10 135 78 11S

-0.73 9

137 8

10S

-0.7 14 135 78 13S 0.36 6

137 9

09S 0.41 8

135 79 10S 0.41 13 137 14 14S

-0.79 13 135 82 12S

-0.78 10 137 18 14S

-0.77 14 135 83 13S 0.34 8

137 40 14S

-0.86 20 135 84 09S 0.39 9

137 40 14S 0.14 10 135 84 10S

-0.73 11 137 44 14S 0.14 8

136 6

09S 0.38 10 137 52 15S 0.14 10 136 8

09S

-0.74 24 137 55 14S

-0.8 10 136 8

09S 0.34 12 137 55 14S 0.2 9

136 12 14S

-0.84 8

137 56 14S 0.18 11 Page 76 of 85

TMl-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 137 59 14S

-0.86 12 138 60 09S 0.41 7

137 59 145 0.2 11 138 60 10S 0.36 9

137 62 09S 0.43 10 138 60 11S

-0.75 9

137 63 09S 0.39 16 138 61 105 0.32 13 137 63 10S 0.29 9

138 62 09S 0.32 16 137 64 10S 0.34 11 138 62 10S 0.32 8

137 65 095 0.41 25 138 62 11S

-0.79 7

137 65 10S 0.38 13 138 63 09S 0.41 16 137 66 105 0.39 8

138 63 105 0.38 11 137 66 125

-0.82 9

138 64 09S 0.39 15 137 67 09S 0.41 16 138 64 125

-0.75 15 137 67 105 0.34 15 138 65 105 0.41 12 137 68 09S

-0.68 15 138 65 125

-0.81 12 137 69 10S 0.38 11 138 65 12S 0.27 9

137 70 155 0.18 10 138 66 09S 0.39 15 137 73 10S 0.41 10 138 66 10S 0.41 9

137 74 105 0.41 17 138 67 095 0.38 11 137 74 11S

-0.75 10 138 67 105 0.34 17 137 75 135 0.34 8

138 68 10S 0.41 16 137 79 10S

-0.75 8

138 68 11S

-0.75 11 137 80 10S

-0.68 16 138 69 09S

-0.68 16 137 80 11S 0.24 11 138 69 09S 0.38 15 137 80 125 0.22 9

138 69 105 0.41 12 137 80 13S

-0.84 21 138 70 10S 0.41 15 137 80 13S 0.25 9

138 71 09S 0.38 9

138 1

09S

-0.71 10 138 71 10S 0.41 12 138 1

09S 0.44 7

138 72 10S 0.41 9

138 5

10S

-0.7 10 139 6

09S 0.38 8

138 7

10S

-0.7 17 139 6

10S

-0.74 20 138 8

09S 0.41 12 139 7

09S

-0.7 10 138 10 14S

-0.84 8

139 7

09S 0.39 13 138 15 145

-0.84 9

139 13 095 0.43 7

138 39 14S 0.16 13 139 13 10S

-0.72 9

138 42 145 0.23 9

139 18 105

-0.7 19 138 43 14S

-0.84 8

139 18 10S 0.29 10 138 44 14S

-0.34 23 139 27 14S

-0.81 8

138 49 145 0.2 10 139 34 14S

-0.89 9

138 54 145

-0.77 13 139 42 14S

-0.86 15 138 54 145 0.23 6

139 45 14S 0.2 7

138 59 09S 0.39 13 139 52 14S

-0.77 11 Page 77 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22)

Attachment I, Exhibit I SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 139 55 145

-0.88 8

140 8

095 0.41 9

139 57 105 0.25 8

140 9

095

-0.7 17 139 57 115

-0.72 9

140 10 105 0.36 9

139 58 095 0.36 12 140 11 095

-0.67 10 139 59 095 0.41 11 140 12 095

-0.72 9

139 59 105 0.36 8

140 12 095 0.39 14 139 59 115

-0.84 9

140 27 145

-0.74 10 139 60 095 0.38 12 140 30 145

-0.79 18 139 60 125

-0.75 11 140 30 145 0.2 12 139 60 125 0.23 7

140 38 145

-0.9 9

139 61 095 0.41 12 140 38 155 0.18 7

139 61 105

-0.7 7

140 44 145 0.23 10 139 61 105 0.32 8

140 46 145

-0.88 13 139 61 125

-0.7 18 140 51 145

-0.77 11 139 62 095 0.41 10 140 51 145 0.23 12 139 62 105 0.36 11 140 54 095 0.36 10 139 62 125

-0.82 7

140 54 115

-0.75 7

139 62 125 0.23 9

140 54 145

-0.75 15 139 63 125 0.29 9

140 55 095 0.36 8

139 65 095 0.36 13 140 55 105 0.34 12 139 65 125

-0.72 12 140 56 095 0.38 8

139 66 095 0.32 15 140 56 105 0.36 12 139 66 125

-0.79 6

140 56 125

-0.75 10 139 66 155 0.18 10 140 56 125 0.27 7

139 67 095 0.32 20 140 57 095 0.38 7

139 67 105 0.41 13 140 57 125

-0.77 7

139 67 125

-0.81 9

140 58 105

-0.7 8

139 68 095 0.38 16 140 58 125

-0.75 7

139 68 105 0.43 6

140 58 155 0.18 11 139 68 125

-0.73 13 140 59 125

-0.75 15 139 69 105 0.41 16 140 60 125

-0.72 12 139 69 125

-0.79 9

140 61 105

-0.68 7

139 72 135 0.34 11 140 61 125 0.25 7

139 73 095 0.41 11 140 61 155 0.16 9

140 6

095

-0.7 9

140 62 095 0.43 7

140 6

095 0.38 6

140 63 095 0.34 11 140 6

105

-0.7 8

140 63 125

-0.79 10 140 7

095 0.4 8

140 64 125

-0.79 12 140 7

105

-0.72 13 140 64 125 0.29 12 140 8

095

-0.68 24 140 65 125

-0.79 8

Page 78 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 140 66 12S 0.29 7

141 61 12S 0.27 9

140 69 11S

-0.83 12 141 62 12S

-0.81 8

140 69 12S

-0.88 11 141 62 12S 0.29 7

140 69 13S

-0.93 11 141 63 12S

-0.79 20 141 7

09S

-0.7 24 141 63 12S 0.27 7

141 7

10S

-0.7 10 141 64 09S 0.41 12 141 8

09S

-0.68 15 141 65 09S 0.37 9

141 8

10S

-0.7 9

141 67 12S 0.25 9

141 8

13S 0.18 7

  • 141 67 13S

-0.83 12 141 9

09S

-0.67 13 141 67 13S 0.2 6

141 9

10S

-0.7 11 141 68 09S

-0.76 9

141 10 09S

-0.7 12 141 68 09S 0.34 17 141 10 09S 0.39 7

141 68 10S

-0.66 16 141 10 10S

-0.7 8

141 68 12S 0.29 20 141 11 10S

-0.69 13 142 9

10S

-0.7 9

141 12 10S

-0.72 8

142 10 10S

-0.7 8

141 13 10S 0.36 12 142 11 10S

-0.74 22 141 14 09S

-0.68 24 142 12 09S 0.41 6

141 14 09S 0.36 9

142 12 10S

-0.72 24 141 15 09S

-0.74 14 142 14 09S

-0.74 10 141 15 10S

-0.72 10 142 14 10S

-0.72 21 141 15 11S

-0.69 10 142 15 10S

-0.7 8

141 38 14S

-0.79 14 142 34 14S

-0.7 9

141 38 14S 0.18 6

142 34 14S 0.2 7

141 39 OBS

-0.77 7

142 35 14S

-0.77 14 141 43 14S

-0.93 9

142 35 14S 0.2 8

141 46 14S 0.18 11 142 37 14S 0.2 8

141 47 10S 0.39 9

142 38 14S 0.23 12 141 52 10S 0.36 8

142 39 14S 0.23 9

141 53 09S 0.39 12 142 40 14S 0.18 12 141 53 10S 0.36 23 142 41 14S

-0.83 9

141 54 09S 0.34 12 142 42 14S

-0.86 8

141 54 10S 0.36 12 142 42 14S 0.23 14 141 54 11S

-0.68 10 142 43 14S 0.25 9

141 55 10S 0.38 13 142 44 14S 0.18 10 141 55 11S

-0.72 19 142 45 09S 0.41 8

141 55 11S 0.34 8

142 45 14S

-0.86 13 141 55 12S

-0.77 9

142 45 14S 0.16 9

141 56 12S

-0.74 11 142 46 08S

-0.75 7

141 58 12S

-0.72 9

142 46 14S

-0.86 18 Page 79 of 85

TMI-1 Steam Generator Tube Inspection Report (I'IR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 142 46 145 0.2 7

143 12 105

-0.7 18 142 46 155 0.21 7

143 17 145

-0.88 10 142 47 145

-0.77 17 143 21 095 0.38 23 142 48 145

-0.86 9

143 22 095 0.36 9

142 48 145 0.23 14 143 22 105 0.36 8

142 50 105 0.39 12 143 22 115

-0.76 11 142 50 145

-0.8 20 143 23 095

-0.7 14 142 50 145 0.23 9

143 25 105 0.34 6

142 51 095

-0.68 11 143 25 145

-0.93 7

142 51 105 0.38 28 143 32 145

-0.77 17 142 52 095 0.36 10 143 32 145 0.23 10 142 52 105 0.38 13 143 38 145

-0.77 13 142 53 105 0.41 10 143 38 145 0.2 10 142 54 105 0.41 7

143 40 105 0.34 10 142 54 125

-0.77 7

143 40 145

-0.82 22 142 55 125

-0.72 11 143 40 145 0.2 12 142 56 125

-0.72 13 143 40 155 0.23 6

142 57 125 0.32 7

143 41 105 0.32 11 142 58 125

-0.75 8

143 41 115

-0.7 9

142 58 125 0.29 7

143 42 095 0.41 7

142 59 125

-0.72 14 143 42 105 0.38 12 142 59 125 0.34 7

143 42 145

-0.88 12 142 60 125 0.32 10 143 42 145 0.25 9

142 61 10S

-0.71 10 143 43 09S

-0.68 11 142 62 105

-0.68 11 143 43 145

-0.82 18 142 63 095 0.39 18 143 44 10S 0.36 8

142 63 105

-0.71 13 143 45 095 0.43 9

142 64 095 0.32 14 143 45 14S

-0.82 9

142 65 125

-0.86 26 143 46 145

-0.74 10 142 65 125 0.29 23 143 46 145 0.25 14 142 65 135

-0.78 13 143 47 105 0.39 12 142 65 135 0.39 11 143 48 095 0.43 6

142 65 145

-0.81 17 143 48 105 0.38 15 143 2

105

-0.73 12 143 48 145

-0.86 9

143 3

10S

-0.7 15 143 49 105 0.39 25 143 4

105

-0.7 17 143 49 145

-0.79 11 143 5

105

-0.7 11 143 51 125

-0.75 14 143 10 095 0.36 7

143 53 125 0.29 8

143 10 105

-0.72 16 143 55 105

-0.7 10 143 11 105

-0.75 14 143 55 105 0.41 8

Page 80 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B1 Broached TSP Wear Indications Sized by Bobbin Probe1 Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 143 56 12S 0.29 8

144 21 11S

-0.77 19 143 58 10S

-0.73 9

144 21 11S 0.3 5

143 58 10S 0.39 16 144 22 09S

-0.74 9

143 58 11S

-0.65 8

144 22 09S 0.34 15 143 59 10S 0.44 15 144 22 11S

-0.7 11 143 60 10S 0.39 10 144 32 14S

-0.88 15 144 2

10S

-0.75 8

144 32 15S 0.21 7

144 2

13S 0.17 19 144 33 14S

-0.83 16 144 3

ass

-0.62 8

144 34 14S

-0.86 9

144 3

10S

-0.72 11 144 35 10S 0.34 12 144 4

10S

-0.73 15 144 36 10S 0.36 12 144 4

14S

-0.76 11 144 38 09S 0.39 16 144 5

10S

-0.73 22 144 38 14S

-0.91 7

144 5

14S

-0.71 15 144 39 09S 0.36 11 144 5

14S 0.32 8

144 39 10S 0.34 11 144 6

10S

-0.72 11 144 39 11S

-0.77 9

144 6

14S

-0.72 17 144 40 09S

-0.7 8

144 6

14S 0.34 8

144 40 09S 0.38 16 144 7

10S

-0.67 34 144 40 10S 0.38 13 144 8

10S

-0.74 16 144 41 09S

-0.7 12 144 8

14S

-0.77 13 144 43 10S 0.41 10 144 8

14S 0.29 8

144 44.10S 0.41 14 144 9

09S 0.38 17 144 44 11S

-0.72 7

144 9

10S

-0.7 33 144 45 10S 0.41 23 144 9

14S

-0.79 8

144 48 09S 0.43 10 144 9

15S 0.27 12 144 48 12S 0.29 9

144 10 10S

-0.72 23 144 49 09S 0.32 10 144 10 11S

-0.68 9

144 49 10S 0.45 7

144 10 14S

-0.81 6

144 49 12S 0.27 8

144 11 10S

-0.68 11 144 so 10S 0.41 13 144 17 10S 0.36 13 144 51 09S 0.43 9

144 18 09S

-0.7 10 144 51 10S

-0.67 9

144 18 10S

-0.7 9

144 52 10S 0.38 10 144 19 10S

-0.72 11 144 53 10S

-0.72 8

144 19 11S 0.32 8

144 53 10S 0.34 14 144 20 10S

-0.68 9

145 3

10S

-0.68 7

144 20 12S

-0.73 8

145 3

14S

-0.75 10 144 21 09S

-0.75 12 145 3

14S 0.32 9

144 21 09S 0.36 15 145 4

10S

-0.72 16 144 21 10S 0.36 8

145 4

14S

-0.76 16 Page 81 of 85

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG BJ Broached TSP Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 145 4

14S 0.29 10 145 38 10S 0.36 13 145 5

10S

-0.75 12 145 39 10S 0.38 18 145 6

14S

-0.74 13 145 39 11S

-0.72 9

145 6

14S 0.29 10 145 40 09S 0.41 21 145 7

10S

-0.74 28 145 40 115

-0.77 12 145 7

14S

-0.74 15 145 41 10S 0.41 13 145 7

14S 0.32 9

145 42 095 0.39 9

145 8

10S

-0.7 15 145 42 11S

-0.77 8

145 8

10S 0.39 12 145 43 10S 0.38 21 145 8

11S

-0.7 12 145 43 11S

-0.7 9

145 8

14S 0.29 7

145 45 12S

-0.77 7

145 11 10S

-0.7 11 145 46 12S

-0.75 11 145 12 09S

-0.68 9

145 47 10S 0.39 8

145 14 11S

-0.75 9

145 47 12S 0.32 13 145 16 09S 0.36 8

145 48 10S 0.39 8

145 17 10S

-0.72 23 145 48 12S

-0.8 10 145 18 10S

-0.79 14 145 49 10S

-0.72 9

145 19 10S

-0.77 11 145 49 10S 0.41 25 145 19 13S

-0.77 16 145 49 12S

-0.73 10 145 19 13S 0.34 12 145 49 12S 0.27 11 145 20 09S

-0.72 24 145 50 08S

-0.72 12 145 20 095 0.36 14 145 50 10S 0.43 12 145 20 13S

-0.84 7

145 50 11S

-0.72 9

145 20 135 0.25 10 146 1

09S 0.44 7

145 21 09S

-0.73 21 146 2

10S

-0.77 7

145 21 11S 0.34 9

146 2

145

-0.76 16 145 22 09S

-0.7 16 146 2

14S 0.37 8

145 23 09S

-0.7 11 146 3

135 0.17 11 145 24 10S 0.34 12 146 4

10S

-0.7 11 145 32 10S 0.34 10 146 6

10S

-0.72 8

145 32 145

-0.84 8

146 7

09S 0.38 10 145 33 09S 0.41 20 146 11 09S 0.4 26 145 33 10S 0.27 9

146 12 10S 0.41 8

145 34 09S 0.41 23 146 13 10S 0.38 10 145 34 10S 0.39 14 146 14 10S 0.36 6

145 34 14S

-0.91 6

146 14 11S

-0.75 6

145 35 09S 0.36 8

146 15 09S 0.38 13 145 36 09S 0.39 18 146 15 10S

-0.74 13 145 37 09S 0.38 17 146 15 13S

-0.77 8

145 37 10S 0.41 8

146 15 135 0.27 13 Page 82 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B~ Broached TSP Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 146 16 11S

-0.74 12 146 40 10S 0.41 15 146 17 10S 0.36 9

146 41 10S 0.39 12 146 19 09S 0.38 14 146 44 12S

-0.82 11 146 19 10S

-0.7 8

146 44 12S 0.29 12 146 20 09S

-0.7 21 146 45 09S 0.44 10 146 20 09S 0.34 12 146 45 10S

-0.7 7

146 21 09S

-0.7 15 146 45 10S 0.36 20 146 21 10S 0.36 10 146 46 09S 0.39 14 146 22 10S 0.32 12 146 46 10S 0.36 22 146 25 09S

-0.7 12 146 47 09S 0.41 10 146 25 09S 0.36 14 146 47 10S 0.36 17 146 26 10S 0.34 10 146 47 12S

-0.75 12 146 26 11S

-0.75 11 146 47 12S 0.29 17 146 26 13S 0.27 9

146 47 13S

-0.77 10 146 26 14S

-0.79 8

146 47 13S 0.36 12 146 27 10S 0.36 10 147 1

13S 0.2 9

146 27 13S 0.27 10 147 3

10S

-0.7 9

146 28 09S 0.36 9

147 4

10S

-0.7 8

146 29 09S 0.36 10 147 5

10S

-0.67 14 146 29 10S 0.39 17 147 6

09S 0.38 5

146 29 13S 0.27 21 147 6

10S

-0.75 14 146 30 09S 0.43 7

147 6

10S 0.41 7

146 30 10S 0.34 12 147 7

09S 0.43 8

146 30 11S

-0.75 8

147 7

10S

-0.69 12 146 31 10S 0.39 11 147 8

10S

-0.68 13 146 31 12S

-0.77 7

147 13 10S

-0.74 13 146 31 13S 0.29 22 147 13 10S 0.36 15 146 32 10S 0.38 7

147 14 10S

-0.7 20 146 33 09S 0.32 8

147 16 10S

-0.72 18 146 34 10S

-0.7 8

147 17 10S

-0.7 16 146 34 10S 0.36 13 147 18 10S

-0.7 8

146 35 09S 0.32 18 147 19 11S

-0.72 9

146 35 10S 0.39 7

147 20 09S

-0.68 10 146 36 09S 0.32 10 147 21 10S 0.39 10 146 37 10S 0.36 19 147 23 10S 0.36 10 146 37 11S

-0.75 9

147 24 09S 0.34 9

146 38 09S 0.36 7

147 24 10S 0.38 8

146 38 10S 0.41 12 147 24 11S

-0.72 9

146 39 10S

-0.7 9

147 24 12S

-0.82 6

146 39 10S 0.38 11 147 25 10S 0.36 12 Page 83 of 85

~~~~~~~~~

-~~~~-~~--

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 147 25 11S

-0.77 12 149 11 10S

-0.7 10 147 26 09S 0.41 8

149 13 10S

-0.7 7

147 26 10S 0.36 8

149 14 10S

-0.74 6

147 26 11S

-0.72 12 149 16 13S

-0.8 8

147 27 10S 0.38 14 149 16 13S 0.34 7

147 27 11S

-0.75 15 149 23 135

-0.77 7

147 27 13S 0.27 24 149 25 13S

-0.77 9

147 27 14S

-0.88 6

149 31 09S 0.39 21 147 28 10S 0.38 9

149 31 10S

-0.68 8

147 29 10S 0.39 17 149 32 10S 0.38 9

147 29 13S

-0.73 10 149 33 12S

-0.75 13 147 29 13S 0.32 9

149 34 10S 0.36 8

147 29 14S

-0.84 8

149 36 12S

-0.82 16 147 30 09S 0.38 12 149 36 13S

-0.7 16 147 30 10S 0.38 11 149 36 13S 0.34 13 147 31 09S 0.36 9

150 2

105

-0.72 9

147 31 10S 0.36 14 150 3

10S

-0.7 13 147 33 09S 0.29 9

150 4

10S

-0.65 10 147 33 13S 0.34 7

150 5

10S

-0.7 10 147 34 095 0.41 16 150 6

10S

-0.7 8

147 35 09S 0.34 7

150 7

10S

-0.7 9

148 1

13S

-0.7 6

150 7

125

-0.88 11 148 2

10S

-0.7 9

150 8

12S

-0.73 11 148 4

105

-0.68 7

150 8

135

-0.82 17 148 9

10S

-0.69 15 150 9

10S

-0.7 8

148 10 10S

-0.68 12 150 10 105

-0.65 9

148 11 10S

-0.72 19 150 11 10S

-0.7 10 148 12 10S

-0.7 16 150 12 10S

-0.67 11 148 15 10S

-0.7 7

150 15 10S

-0.68 10 148 16 13S 0.31 13 150 17 10S

-0.68 8

148 17 105

-0.72 11 150 24 09S 0.39 8

148 20 13S

-0.77 18 150 27 09S 0.39 16 148 22 13S

-0.72 23 150 27 125 0.32 8

148 25 10S

-0.7 7

150 27 13S

-0.78 11 148 27 07S

-0.57 6

150 29 12S

-0.78 10 148 28 09S 0.47 8

150 31 10S

-0.65 9

149 3

10S

-0.68 11 151 2

12S

-0.85 10 149 4

10S

-0.7 7

151 4

115 0.27

  • 7 149 6

10S

-0.7 11 151 5

09S

-0.72 11 149 8

10S

-0.7 7

151 5

11S 0.32 8

Page 84 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22)

Attachment I, Exhibit I SG B, Broached TSP Wear Indications Sized by Bobbin Probe, Outage T1R22 Location Location Row Tube TSP Offset TW Comment Row Tube TSP Offset TW Comment 151 5

14S

-0.78 11 151 6

10S

-0.72 7

151 8

07S

-0.75 9

151 8

10S

-0.7 7

151 9

12S

-0.9 11 151 9

13S

-0.92 8

151 9

14S

-0.83 20 151 22 09S

-0.73 10 151 23 12S 0.29 12 Page 85 of 85

TMI-1 Steam Generator Tube Inspection Report (TIR22), Exhibit I SG 8~ Drilled Support TSP Wear Indications Sized by +Point Probe~ Outage T1R22 Location Row Tube TSP Offset TW Circ Length {in.)

Percent Degraded Area 8

5 15S +0.27 17 0.80 7

8 6

15S +0.25 18 0.82 8

10 6

15S +0.25 18 0.80 7

11 8

15S +0.42 18 0.87 4

13 8

15S +0.27 18 0.78 3

46 118 15S +0.45 28 0.23 10 108 3

15S +0.22 22 0.89 9

144 5

15S +0.35 17 0.68 4

144 6

15S +0.35 21 0.84 7

144 8

15S +0.30 11 0.73 2

145 6

15S +0.35 16 0.82 4

146 2

15S +0.42 10 0.48 7

150 3

15S +0.27 14 0.50 8

Page 1 of 1

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Tube-to-Tube Wear Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Row Tube TSP Offset TW 22 52 08S 18.4 12 29 33 08S 18.84 8

22 53 08S 18.02 10 29 38 08S 18.18 9

22 62 08S 16.98 17 29 39 08S 18.09 8

22 63 08S 17.05 19 29 42 07S 19.84 7

22 67 08S 18.46 8

29 42 08S 17.89 10 23 46 08S 18.63 9

29 68 08S 18 12 23 47 08S 18.97 7

29 69 08S 17.83 10 23 52 08S 17.9 7

29 80 08S 17.4 11 23 60 08S 17.87 9

30 31 08S 18.04 11 23 61 07S 19.89 11 30 32 08S 17.94 14 23 61 08S 17.81 7

30 33 08S

  • 18.25 12 23 62 07S 19.86 10 30 34 08S 18.7 11 23 63 08S 16.7 12 30 35 08S 18.62 10 23 67 08S 18.48 10 30 36 08S 17.73 10 24 so 08S 18 10 30 37 08S 19.1 8

24 55 08S 17.83 8

30 42 08S 18.43 11 25 29 08S 18.63 10 30 73 08S 18.58 11 25 33 08S 18.66 13 30 74 08S 19.32 10 25 39 08S 18 16 30 80 08S 17.55 10 25 48 08S 18.15 8

30 81 08S 18.69 12 25 59 08S 17.31 8

31 32 08S 17.73 9

26 29 08S 17.64 10 31 35 08S 18.13 10 26 30 08S 19.27 11 31 38 08S 17.23 8

26 33 08S 17.82 14 31 41 08S 18.29 9

26 39 08S 16.96 15 31 45 08S 17.41 10 26 43 08S 17.75 12 31 56 08S 17.43 11 26 49 08S 18.16 8

31 64 08S 17.89 7

26 68 08S 18.54 7

31 65 08S 18.23 8

27 44 08S 17.39 11 31 73 08S 18.12 9

27 49 08S 18.03 9

32 25 08S 17.99 8

27 so 08S 17.76 9

32 26 08S 18.68 11 27 63 08S 17.56 7

32 27 08S 18.38 11 27 69 08S 17.11 9

32 28 08S 17.81 8

28 32 07S 20.64 9

32 29 08S 17.74 12 28 42 07S 18.98 10 32 34 08S 19.3 8

28 63 08S 17.67 9

32 35 08S 18.75 9

28 68 08S 17.93 9

32 40 08S 17.21 9

29 31 08S 16.98 10 32 44 08S 17.9 10 29 32 07S 20.31 7

32 55 08S 17.26 9

29 32 08S 17.88 15 32 56 08S 17.57 11 Page 1 of 4

TMI-1 Steam Generator Tube Inspection Report (TIR22), Exhibit I SG BJ Tube-to-Tube Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Row Tube TSP Offset TW 32 59 08S 18.72 10 39 33 08S 19.56 10 32 67 08S 18.56 11 39 34 08S 17.98 11 32 68 08S 18.7 6

39 90 08S 17.94 9

32 69 08S 17.87 11 39 91 08S 17.73 11 32 73 08S 18.83 11 40 33 08S 16.7 9

32 77 08S 18.27 10 40 34 08S 18.11 9

33 26 08S 19.23 9

40 90 08S 17.52 9

33 27 08S 18.82 9

40 91 08S 18.02 8

33 28 08S 18.41 11 40 95 08S 16.63 9

33 30 08S 18.25 12 33 48 08S 18.05.

7 40 96 08S 17.96 9

33 49 08S 18.08 9

41 89 08S 16.56 10 33 61 08S 18.02 11 41 92 08S 18.76 8

33 69 08S 18.55 11 42 25 08S 18.82 11 33 75 08S 18.52 10 42 26 08S 18.85 9

33 79 08S 18.43 9

42 27 08S 17.49 8

34 25 08S 18.62 10 42 87 08S 18.5 10 34 26 08S 20.29 10 42 89 08S 18.5 9

34 27 08S 19.87 15 42 90 08S 17.32 11 34 78 08S 19.04 8

43 24 08S 18.38 11 34 86 07S 20.29 11 43 25 08S 19.36 9

34 87 07S 19.88 11 43 26 08S 19.41 12 35 25 08S 18.68 9

43 32 08S 18.27 10 35 26 08S 18.56 11 43 91 08S 17.75 9

35 27 08S 19.63 13 44 24 08S 18.19 12 35 28 08S 18.75 9

44 32 08S 17.19 9

35 30 08S 19.S 11 44 33 08S 18.4 9

35 31 08S 17.1 7

45 24 08S 18.69 11 35 34 08S 19.5 7

45 28 08S 18.22 12 35 35 08S 18.44 7

45 32 08S 19.22 9

35 36 08S 19.04 7

45 84 08S 18.29 14 35 79 08S 18.89 11 46 24 08S 19.62 8

36 30 08S 17.61 10 46 25 08S 18.89 11 36 31 08S 18.32 9

46 26 08S 19.18 8

36 34 08S 19.9 8

46 29 08S 17.74 11 36 35 08S 18.68 8

46 32 08S 18.14 10 36 37 08S 18.26 8

46 83 08S 19.29 11 38 33 08S 18.89 10 46 84 08S 18.59 19 38 74 08S 18.73 8

46 85 08S 18.66 11 38 75 08S 19.04 8

46 99 08S 18.16 9

Page 2 of4

TMI-1 Steam Generator Tube Inspection Report (TIR22), Exhibit I SG BJ Tube-to-Tube Wear Indications Sized by Bobbin ProbeJ Outage T1R22 Location Location Row Tube TSP Offset TW Row Tube TSP Offset TW 46 103 085 18.45 9

76 110 085 17.74 8

47 97 085 17.53 8

77 112 085 18.39 8

47 98 085 18.44 9

78 101 045 18.93 11 47 101 085 17.93 16 79 102 045 19.21 11 47 102 085 17.58 12 79 102 085 19.12 7

48 99 085 18.26 8

79 103 085 18.73 5

50 103 085 16.75 16 79 114 085 18.01 8

50 104 085 18.99 10 80 26 085 18.49 9

51 31 085 18.83 8

80 114 085 18 8

51 103 085 19.02 12 81 27 085 18.53 9

52 31 085 18.26 10 81 34 085 18.95 7

52 104 085 18.65 11 82 34 085 19.03 6

52 106 085 18.37 13 85 109 085 18.17 10 53 100 085 18.52 7

86 22 085 19.37 13 53 101 085 18.24 7

86 107 085 17.84 6

53 104 085 18.87 10 86 108 085 18.29 9

53 105 085 19.18 12 86 109 085 18.33 9

54 103 085 18.46 9

87 22 085 19.37 11 54 105 085 18.44 12 87 109 085 19.81 9

54 106 085 19.38 9

88 110 085 18.79 11 55 104 085 18.28 10 89 111 085 18.12 10 55 106 085 17.92 10 90 100 045 19.34 10 56 34 085 18.8 11 90 100 085 18.49 7

56 107 085 18.47 6

91 102 045 17.75 10 56 108 085 18.42 9

91 102 085 18.63 7

57 31 085 17.77 10 91 110 085 18.02 8

57 34 085 18.84 12 91 111 085 19.34 8

57 111 085 18.29 11 92 30 085 18.36 8

58 32 085 18.11 9

93 23 085 18.45 11 58 112 085 18.41 12 93 30 085 18.41 9

61 111 085 17.54 11 93 103 085 17.2 6

61 112 085 18.38 10 94 24 085 19.07 10 66 83 075 18.95 9

94 26 085 19.23 10 66 84 075 20.05 9

94 103 085 17.68 5

68 112 085 18.01 9

95 26 085 19.4 9

68 113 085 17.98 9

95 100 085 17.58 5

68 114 085 16.7 14 96 100 085 17.36 6

69 113 085 16.89 16 97 103 085 17.81 8

69 114 085 16.39 14 97 104 085 18.01 9

70 112 085 17.69 14 98 102 085 17.94 10 Page 3 of4

TMI-1 Steam Generator Tube Inspection Report (TJR22), Exhibit 1 SG B~ Tube-to-Tube Wear.Indications Sized by Bobbin Probe~ Outage T1R22 Location Location Row Tube TSP Offset TW Row Tube TSP Offset TW 99 95 085 17.96 5

119 82 085 17.84 9

99 101 085 18.13 9

120 73 085 18.77 7

99 102 085 17.84 9

121 71 085 18.8 8

100 32 085 17.63 8

122 70 085 18.98 7

100 94 085 17.98 6

123 66 085 17.63 7

100 100 085 18.04 8

123 67 085 17.17 7

101 32 085 17.69 8

124 48 085 17.49 7

101 94 085 17.6 10 124 49 085 17.15 8

101 95 085 17.66 10 124 61 085 21.72 7

105 92 085 17.86 7

105 95 085 18.38 9

106 78 045 18.15 12 106 92 085 17.88 8

106 95 085 18.1 9

107 77 045 17.57 12 107 77 085 17.92 11 107 78 085 18.95 11 112 71 085 18.72 8

113 71 085 18.74.

9 114 42 085 16.93 6

115 37 075 19.53 10 115 42 085 17.65 7

115 83 085 17.89 8

115 84 085 17.92 8

116 34 085 17.09 9

116 35 085 17.6 11 116 37 075 20.56 9

116 37 085 17.73 6

116 38 085 17.59 6

116 86 085 17.78 9

116 87 085 18 8

117 83 085 17.79 8

118 35 085 18.4 12 118 36 085 17.87 12 118 82 085 18.16 9

118 83 085 17.79 10 119 75 085 18.11 6

119 78 085 17.91 11 119 79 085 18.19 11 119 81 085 18.13 10 Page4 of 4