Revision as of 09:06, 7 February 2019

Acceptance Review - Relief Request 1B3-4, Comanche Peak Nuclear Power Plant, Unit 1
ML15147A173
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 05/27/2015
From: Singal B K
Plant Licensing Branch IV
To: Hope T R
Luminant Generation Co
References
TAC MF6132
Download: ML15147A173 (2)


Text

1 NRR-PMDAPEm Resource From: Singal, Balwant Sent: Wednesday, May 27, 2015 9:07 AM To: 'Hope, Timothy' (Timothy.Hope@luminant.com)

Cc: 'Jack.Hicks@luminant.com' (Jack.Hicks@luminant.com)

Subject:

Acceptance Review - Relief Request 1B3-4, Co manche Peak Nuclear Power Plant, Unit 1 (TAC No. MF6132)

Tim, By letter dated April 22, 2015 (Agencywide Document s Access and Management System (ADAMS) Accession No. ML15120A038), Luminant Generation Company LLC, requested approval for alternative to the reactor pressure vessel head penetration weld inspection frequency from 10 to 15 years for Comanche Peak Nuclear

Power Plant, Unit 1.

The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staff's acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to a llow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant. The NRC staff has reviewed your application and concluded that it does provide technical information in

sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staff's ability to complete the detailed te chnical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please contact me.

Balwant K. Singal Senior Project Manager, Comanche Peak and Columbia

Balwant.singal@nrc.gov 301-415-3016

Hearing Identifier: NRR_PMDA Email Number: 2109 Mail Envelope Properties (192BB59294514E41B5305C3C82867608018BDBE5A04E)

Subject:

Acceptance Review - Relief Request 1B3-4, Comanche Peak Nuclear Power Plant, Unit 1 (TAC No. MF6132) Sent Date: 5/27/2015 9:07:23 AM Received Date: 5/27/2015 9:07:00 AM From: Singal, Balwant Created By: Balwant.Singal@nrc.gov Recipients: "'Jack.Hicks@luminant.com' (Jack.Hicks@luminant.com)" <Jack.Hicks@luminant.com> Tracking Status: None

"'Hope, Timothy' (Timothy.Hope@luminant.com)" <Timothy.Hope@luminant.com> Tracking Status: None

Post Office: HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 1893 5/27/2015 9:07:00 AM

Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: Recipients Received: