ML17207A125: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 1: Line 1:
#REDIRECT [[05000313/LER-2017-002]]
{{Adams
| number = ML17207A125
| issue date = 07/26/2017
| title = LER 17-002-00 for Arkansas Nuclear One, Unit 1, Regarding High Pressure Injection Pump Inoperable for Greater than Technical Specification Completion Time
| author name = Pyle S L
| author affiliation = Entergy Operations, Inc
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000313
| license number =
| contact person =
| case reference number = 1CAN071702
| document report number = LER 17-002-00
| document type = Letter, Licensee Event Report (LER)
| page count = 5
}}

Revision as of 01:36, 5 March 2018

LER 17-002-00 for Arkansas Nuclear One, Unit 1, Regarding High Pressure Injection Pump Inoperable for Greater than Technical Specification Completion Time
ML17207A125
Person / Time
Site: Arkansas Nuclear, Arkansas Nuclear One – Unit 1 Entergy icon.png
Issue date: 07/26/2017
From: Stephanie Pyle
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
1CAN071702 LER 17-002-00
Download: ML17207A125 (5)