NOTICE: Attachments 1 through 5 to this letter contains Proprietary Information to be withheld from public disclosure per 10 CFR 2.390. Upon separation from Attachments 1 through 5, this letter is DECONTROLLED.

Entergy Operations, Inc., 1340 Echelon Parkway, Jackson, MS 39213 2CAN112403 10 CFR 50.55a November 11, 2024 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Relief Request ANO2-RR-24-001, Half-Nozzle Repair of Reactor Vessel Closure Head Penetration #71 - One Cycle Justification Arkansas Nuclear One, Unit 2 NRC Docket No. 50-368 Renewed Facility Operating License No. NPF-6 During the current Arkansas Nuclear One, Unit 2 (ANO-2) refueling outage 2R30, an indication was detected on Reactor Vessel Closure Head (RVCH), Penetration #71. This indication was determined to be unacceptable based on requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code). Entergy Operations, Inc. (Entergy) submitted Relief Request ANO2-RR-24-001 via Reference 1. In Reference 1, Entergy proposed an alternative to the ASME Code repair/replacement requirements as a repair to the ANO-2 RVCH.

The NRC provided their verbal authorization to utilize Relief Request ANO2-RR-24-001 on October 21, 2024 (Reference 2).

As discussed in Reference 1, Entergy committed to supplying the final one-cycle flaw analytical evaluation, evaluation of repair, and the corrosion evaluation within 14 days of the startup from 2R30. 2R30 was completed on October 28, 2024.

Attachments 1 through 5 contain information proprietary to Framatome Inc. (Framatome).

Framatome requests that these documents be withheld from public disclosure in accordance with 10 CFR 2.390(a)(4). Affidavits supporting this request are contained in Attachments 6, 7, 8, 9, and 10. Attachments 11, 12, 13, 14, and 15 contain non-proprietary versions of the Framatome documents.

There are no new regulatory commitments established in this submittal.

If there are any questions or if additional information is needed, please contact Riley Keele, Manager, Regulatory Assurance, Arkansas Nuclear One, at 479-858-7826.

Phil Couture Senior Manager Fleet Regulatory Assurance - Licensing Tel 601-368-5102

2CAN112403 Page 2 of 4 Respectfully, Phil Couture PC/rwc References

1. Entergy letter to the NRC, "Relief Request ANO2-RR-24-001 Half-Nozzle Repair of Reactor Vessel Closure Head Penetration #71, ML24295A120, (2CAN102402), dated October 21, 2024.
2. NRC email to Entergy "Arkansas Nuclear One, Unit 2 - Verbal Authorization of Relief Request ANO2-RR (EPID L-2024-LLR-0065)," ML24296A065 (2CNA102402), dated October 22, 2024.

Digitally signed by Philip Couture DN: cn=Philip Couture, c=US, o=Entergy, ou=Regulatory Assurance, email=pcoutur@entergy.com Date: 2024.11.11 11:45:31 -06'00' Philip Couture

2CAN112403 Page 3 of 4 Attachments:

PROPRIETARY VERSION OF ANALYSES

1. "Corrosion Evaluation of ANO-2 RVCH CEDM IDTB Weld Nozzle Penetration Repair,"

Document Number 51-9384397-001 PROPRIETARY

2. "PWSCC Evaluation for Alloy 600 in ANO-2 CEDM Penetration No. 71 IDTB Weld Repair,"

Document Number 51-9384385-001 PROPRIETARY

3. "ANO-2 CEDM Number 71 IDTB Weld Repair One-Cycle Justification," Document Number 32-9384450-000 PROPRIETARY
4. "ANO-2 CEDM Penetration 71 Modification As-Left J-Groove Weld One Cycle Justification,"

Document Number 32-9384449-000 PROPRIETARY

5. "OCJ IDTB Weld Anomaly Assessment at CEDM Nozzle No. 71 at ANO 2," Document Number 32-9384443-000 PROPRIETARY AFFIDAVITS
6. Affidavit for "Corrosion Evaluation of ANO-2 RVCH CEDM IDTB Weld Nozzle Penetration Repair," Document Number 51-9384397-001
7. Affidavit for "PWSCC Evaluation for Alloy 600 in ANO-2 CEDM Penetration No. 71 IDTB Weld Repair," Document Number 51-9384385-001
8. Affidavit for "ANO-2 CEDM Number 71 IDTB Weld Repair One-Cycle Justification,"

Document Number 32-9384450-000

9. Affidavit for "ANO-2 CEDM Penetration 71 Modification As-Left J-Groove Weld One Cycle Justification," Document Number 32-9384449-000
10. Affidavit for "OCJ IDTB Weld Anomaly Assessment at CEDM Nozzle No. 71 at ANO 2,"

Document Number 32-9384443-000 NON-PROPRIETARY VERSIONS OF ANALYSES

11. "Corrosion Evaluation of ANO-2 RVCH CEDM IDTB Weld Nozzle Penetration Repair,"

Document Number 51-9384465-001 NON-PROPRIETARY

12. "PWSCC Evaluation for Alloy 600 in ANO-2 CEDM Penetration No. 71 IDTB Weld Repair,"

Document Number 51-9384386-001 NON-PROPRIETARY

13. "ANO-2 CEDM Number 71 IDTB Weld Repair One-Cycle Justification," Document Number 32-9384470-000 NON-PROPRIETARY
14. "ANO-2 CEDM Penetration 71 Modification As-Left J-Groove Weld One Cycle Justification,"

Document Number 32-9384463-000 NON-PROPRIETARY

2CAN112403 Page 4 of 4

15. "OCJ IDTB Weld Anomaly Assessment at CEDM Nozzle No. 71 at ANO 2," Document Number 32-9384462-000 NON-PROPRIETARY cc:

NRC Region IV Regional Administrator NRC Senior Resident Inspector - Arkansas Nuclear One NRC Project Manager - Arkansas Nuclear One