{{#Wiki_filter:e Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit JUL 161996 LR-N96200 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
{{#Wiki_filter:e OPS~G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit JUL 161996 LR-N96200 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
LER 272/96-010-00 SALEM GENERATING STATION -UNIT* 1 FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 This Licensee Event Report entitled "Inadequate Pressurizer Relief Tank Supports" is being submitted pursu?-nt to the requirements of the Code of Federal Regulations 10CFR50. 73 (a) (2) (ii). Attachment SORC Mtg. 96-095 JMO/tcp C Distribution LER File 3.7 9607230284 960716 PDR ADOCK 05000272 S PDR The po.ver is in )'Dur hands. . Sincerely, General Manager -Salem Operations 95-2168 REV. 6/94
LER 272/96-010-00 SALEM GENERATING STATION - UNIT* 1 FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 This Licensee Event Report entitled "Inadequate Pressurizer Relief Tank Supports" is being submitted pursu?-nt to the requirements of the Code of Federal Regulations 10CFR50. 73 (a) (2) (ii).
.. Document Control Desk LR-N96200 Attachment A The following item represents the commitment that Public Service Electric & Gas (PSE&G) made to the Nuclear Regulatory Commission (NRC) relative to this LER (272/96-010-00) . The commitment is as follows: Revise each unit's PRT support design to withstand hydrodynamic loads and complete any required modifications for each unit prior to that unit's entry into mode 3.}}
Sincerely, c;!:;;~/
General Manager -
Salem Operations Attachment SORC Mtg. 96-095 JMO/tcp C       Distribution LER File 3.7 9607230284 960716 PDR ADOCK 05000272 S                         PDR The po.ver is in )'Dur hands. .
95-2168 REV. 6/94
 
..
Document Control Desk LR-N96200 Attachment A The following item represents the commitment that Public Service Electric & Gas (PSE&G) made to the Nuclear Regulatory Commission (NRC) relative to this LER (272/96-010-00) . The commitment is as follows:
Revise each unit's PRT support design to withstand hydrodynamic loads and complete any required modifications for each unit prior to that unit's entry into mode 3.}}

Revision as of 09:43, 21 October 2019

Forwards LER 96-010-00 Re Inadequate Pressurizer Relief Tank Supports.Attachment a Represents Commitment Made to NRC
ML18102A262
Person / Time
Site: Salem PSEG icon.png
Issue date: 07/16/1996
From: Garchow D
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18102A263 List:
References
LR-N96200, NUDOCS 9607230284
Download: ML18102A262 (2)


Text

e OPS~G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit JUL 161996 LR-N96200 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

LER 272/96-010-00 SALEM GENERATING STATION - UNIT* 1 FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 This Licensee Event Report entitled "Inadequate Pressurizer Relief Tank Supports" is being submitted pursu?-nt to the requirements of the Code of Federal Regulations 10CFR50. 73 (a) (2) (ii).

Sincerely, c;!:;;~/

General Manager -

Salem Operations Attachment SORC Mtg.96-095 JMO/tcp C Distribution LER File 3.7 9607230284 960716 PDR ADOCK 05000272 S PDR The po.ver is in )'Dur hands. .

95-2168 REV. 6/94

..

Document Control Desk LR-N96200 Attachment A The following item represents the commitment that Public Service Electric & Gas (PSE&G) made to the Nuclear Regulatory Commission (NRC) relative to this LER (272/96-010-00) . The commitment is as follows:

Revise each unit's PRT support design to withstand hydrodynamic loads and complete any required modifications for each unit prior to that unit's entry into mode 3.