{{#Wiki_filter:SEtOjh ZO(Z301              osf    Sci Request for answer key change for Question #62.
Based on the following documentation Sequoyah Station requests that the correct answer for question #62 be changed from A to D.
#62. (9/13 missed)    Substantive post exam comments were provided by the following candidates:
Docket #s- 23598; 22636; 23595; 23790; 23791; 23795 Question:
Given the following plant conditions:
* Unit 1 is shutdown and at NOP and NOT.
* Chemistry reports the Hydrogen concentration in A Waste Gas Decay tank at 5% by volume and Oxygen concentration at 3% by volume.
Which ONE of the following describes the gas concentration, if any, that exceeded the Unit 1 Tech Spec 3.11.2.5 limit for waste gas decay tanks?
A.      Oxygen only.
B.      Hydrogen only.
C.      Neither Hydrogen or Oxygen.
D.      Both Hydrogen and Oxygen.
Original answer: A
 
==Reference:==
Tech Spec 3.11.2.5, Explosive Gas Mixtures.
Recommended change in the correct answer to D.
Justification:
All listed candidates made same comment:
The stem stated that Hydrogen concentration of A WGDT is at 5% and Oxygen concentration is at 3% by volume.
Tech Spec LCO 3.11.2.5 states the concentration of oxygen in the waste gas holdup system shall be limited to less than or equal to 2% by volume whenever the hydrogen concentration exceeds 4% by volume. The basis for this specification states; this specification is provided to ensure that the concentration of potentially explosive gas mixtures contained in the waste gas holdup system is maintained below the flammability limits of hydrogen and oxygen.
 
The surveillance requirement directs the determination of both H2 and 02 concentrations. The determination of both gases is due to the fact that if the H2 concentration is greater than a limit of 4%, then the 02 limits are required to comply with the LCO.
Furthermore, if the hydrogen concentration is reduced to below the hydrogen limit of 4%, then oxygen would be within its limits. If 02 increased to greater than 4% and Hydrogen is greater than the limit of 2% (which is less than LCO 3.11.2.5) then additional actions are required per action b.
Thus the Tech Spec LCO does contain a limit for Hydrogen (either 2% or 4%) and a limit for Oxygen (either 2% or 4%) so since H2 given in the stem is greater than 4% its limit has been exceeded and since 02 given in the stem is greater than 2% its limit is also exceeded.
Sequoyah Station agrees with the candidates and recommends that the correct answer be changed to D.
 
RADIOACTIVE EFFLUENTS EXPLOSIVE GAS MIXTURE LIMITING CONDITION FOR OPERATION 3.11.2.5 The concentration of oxygen in the waste gas holdup system shall be limited to less than or equal to 2% by volume whenever the hydrogen concentration exceeds 4% by volume.
APPLICABILITY: At all times.
ACTION:
: a.      With the concentration of oxygen in a waste gas holdup tank greater than 2% by volume but less than or equal to 4% by volume, reduce the oxygen concentration to the above limits within 48 hours.
: b.      With the concentration of oxygen in a waste gas holdup tank greater than 4% by volume and the hydrogen concentration greater than 2% by volume, without delay suspend all additions of waste gases to the affected waste gas holdup tank and reduce the concentration of oxygen to less than or equal to 2% by volume without delay.
: c. The provisions of Specification 3.0.3 are not applicable.                                  VI SURVEILLANCE REQUIREMENTS determined 4.11.2.5 The concentration of hydrogen and oxygen in the waste gas holdup system shall be system with to be within the above limits by monitoring the waste gas additions to the waste gas holdup the hydrogen and oxygen monitors required OPERABLE by Table 3.3-13 of Specification 3.3.3.10.
April 11,2005 SEQUOYAH UNIT 1-314 11-4                  Amendment No. 42, 148, 301
 
RADiOACTIVE EFFLUENTS
-BASES 3/4.11.2.5 EXPLOSIVE GAS MIXTURE ive gas mixtures This specification is provided to ensure that the concentration of potentially explos limits of hydrog  en and contained in the waste gas holdup system is maintained below the flammability flammability  limits  provid  es oxygen. Maintaining the concentration of hydrogen and oxygen below their mance    with  the assurance that the releases of radioactive materials will be controlled in confor requirements of General Design Criterion 60 of Appendix A to 10 CFR Part 50.
3/4.11.2.6 GAS DECAY TANKS ce that Restricting the quantity of radioactivity contained in each gas decay tank provides assuran ts, the resulting total body  exposu  re  to an in the event of an uncontrolled release of the tanks conten tent with individual at the nearest exclusion area boundary will not exceed 0.5 rem. This is consis Standard Review Plan 15.7.1, Waste Gas System        Failure.
3/4.11.3 This specification is deleted.
3/4.11.4 This specification is deleted.
November 16, 1990 SEQUOYAH      - UNIT 1                              B 3/4 11-2                            Amendment No. 42, 148}}

Latest revision as of 08:49, 12 November 2019

Initial Exam 2012-301 Post Exam Comments
ML120550259
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 02/21/2012
From:
NRC/RGN-II
To:
Tennessee Valley Authority
Gerald Laska
References
50-327/12-301, 50-328/12-301
Download: ML120550259 (4)


Text

SEtOjh ZO(Z301 osf Sci Request for answer key change for Question #62.

Based on the following documentation Sequoyah Station requests that the correct answer for question #62 be changed from A to D.

  1. 62. (9/13 missed) Substantive post exam comments were provided by the following candidates:

Docket #s- 23598; 22636; 23595; 23790; 23791; 23795 Question:

Given the following plant conditions:

  • Unit 1 is shutdown and at NOP and NOT.
  • Chemistry reports the Hydrogen concentration in A Waste Gas Decay tank at 5% by volume and Oxygen concentration at 3% by volume.

Which ONE of the following describes the gas concentration, if any, that exceeded the Unit 1 Tech Spec 3.11.2.5 limit for waste gas decay tanks?

A. Oxygen only.

B. Hydrogen only.

C. Neither Hydrogen or Oxygen.

D. Both Hydrogen and Oxygen.

Original answer: A

Reference:

Tech Spec 3.11.2.5, Explosive Gas Mixtures.

Recommended change in the correct answer to D.

Justification:

All listed candidates made same comment:

The stem stated that Hydrogen concentration of A WGDT is at 5% and Oxygen concentration is at 3% by volume.

Tech Spec LCO 3.11.2.5 states the concentration of oxygen in the waste gas holdup system shall be limited to less than or equal to 2% by volume whenever the hydrogen concentration exceeds 4% by volume. The basis for this specification states; this specification is provided to ensure that the concentration of potentially explosive gas mixtures contained in the waste gas holdup system is maintained below the flammability limits of hydrogen and oxygen.

The surveillance requirement directs the determination of both H2 and 02 concentrations. The determination of both gases is due to the fact that if the H2 concentration is greater than a limit of 4%, then the 02 limits are required to comply with the LCO.

Furthermore, if the hydrogen concentration is reduced to below the hydrogen limit of 4%, then oxygen would be within its limits. If 02 increased to greater than 4% and Hydrogen is greater than the limit of 2% (which is less than LCO 3.11.2.5) then additional actions are required per action b.

Thus the Tech Spec LCO does contain a limit for Hydrogen (either 2% or 4%) and a limit for Oxygen (either 2% or 4%) so since H2 given in the stem is greater than 4% its limit has been exceeded and since 02 given in the stem is greater than 2% its limit is also exceeded.

Sequoyah Station agrees with the candidates and recommends that the correct answer be changed to D.

RADIOACTIVE EFFLUENTS EXPLOSIVE GAS MIXTURE LIMITING CONDITION FOR OPERATION 3.11.2.5 The concentration of oxygen in the waste gas holdup system shall be limited to less than or equal to 2% by volume whenever the hydrogen concentration exceeds 4% by volume.

APPLICABILITY: At all times.

ACTION:

a. With the concentration of oxygen in a waste gas holdup tank greater than 2% by volume but less than or equal to 4% by volume, reduce the oxygen concentration to the above limits within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.
b. With the concentration of oxygen in a waste gas holdup tank greater than 4% by volume and the hydrogen concentration greater than 2% by volume, without delay suspend all additions of waste gases to the affected waste gas holdup tank and reduce the concentration of oxygen to less than or equal to 2% by volume without delay.
c. The provisions of Specification 3.0.3 are not applicable. VI SURVEILLANCE REQUIREMENTS determined 4.11.2.5 The concentration of hydrogen and oxygen in the waste gas holdup system shall be system with to be within the above limits by monitoring the waste gas additions to the waste gas holdup the hydrogen and oxygen monitors required OPERABLE by Table 3.3-13 of Specification 3.3.3.10.

April 11,2005 SEQUOYAH UNIT 1-314 11-4 Amendment No. 42, 148, 301

RADiOACTIVE EFFLUENTS

-BASES 3/4.11.2.5 EXPLOSIVE GAS MIXTURE ive gas mixtures This specification is provided to ensure that the concentration of potentially explos limits of hydrog en and contained in the waste gas holdup system is maintained below the flammability flammability limits provid es oxygen. Maintaining the concentration of hydrogen and oxygen below their mance with the assurance that the releases of radioactive materials will be controlled in confor requirements of General Design Criterion 60 of Appendix A to 10 CFR Part 50.

3/4.11.2.6 GAS DECAY TANKS ce that Restricting the quantity of radioactivity contained in each gas decay tank provides assuran ts, the resulting total body exposu re to an in the event of an uncontrolled release of the tanks conten tent with individual at the nearest exclusion area boundary will not exceed 0.5 rem. This is consis Standard Review Plan 15.7.1, Waste Gas System Failure.

3/4.11.3 This specification is deleted.

3/4.11.4 This specification is deleted.

November 16, 1990 SEQUOYAH - UNIT 1 B 3/4 11-2 Amendment No. 42, 148