SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPMA

Task:

Shutdown Bank Withdrawal Task#:

0010180101 1503 NRC Sim JPM A Page 2of19 Task Standard:

The examinee will close the Reactor Trip Breakers and commence Shutdown Bank withdrawal.

The examinee will Trip the Reactor when continuous rod withdrawal occurs.

Alternate Path:

YES:

x NO:

Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

001A2.11 (4.4/4.7)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

23 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Ensure Simulator Operator Checklist is complete
2.

Reset to IC 256

3.

IF IC #256 is not available then reset to IC#16 1503 NRC Sim JPM A Page 3of19 Hold FW Isolation 'reset pushbuttons' and trip the Reactor. Leave Rods in Manual.

Select a SR and IR pen for NR45.

Ensure Audio Count rate is audible.

Clear and unblock HI Flux at Shutdown alarm.

Clear 1st out.

Insert overrides to cause either SD bank A to withdraw continuously when Rods Out Light comes on.

{zdiflrm1 [1]} IOR ZDIFLRM1 f:1 (overrides In-Hold-Out switch to OUT)

{zdiflrm1 [1]} IOR ZDIRBSS1 f:6 (overrides Bank Select Switch to SOB A)

IOR AN_OV _325 f:1 (fails annunciator as is for Computer Alarm Rod Dev.)

4. JPM Steps 7 through 1 O will require a simulator operator.
5.

PLACE SIMULATOR IN RUN

6. An extra operator will be required to acknowledge alarms.
7. ACKNOWLEDGE ALARMS
8.

FREEZE SIMULA TOR.

9.

Save as a temporary IC, if repeat runs of JPM will be desired.

10. PLACE SIMULATOR IN RUN
11. After JPM is complete, delete the temporary IC, if used. Delete the contents of the recycle bin, If a temporary IC has been deleted.

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT /UNSA T column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

1. Marked up copy of O-S0-85-1, Control Rod Drive System, section 5.5 (marked through Step 10) and 6.3
2. Tl-28 Attachment 6

References:

Reference Title Rev No.

1.

O-S0-85-1 Control Rod Drive System 42

1503 NRC Sim JPM A Page 4of19

========================================================================

DIRECTIONS TO EXAMINEE:

1503 NRC Sim JPM A Page 5of19 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1. Unit 1 is in MODE 3 with Tavg at 547F and RCS pressure at 2235 psig.
2. Both M-G sets are in service.
3. All Precautions and Prerequisites of O-S0-85-1, Control Rod Drive System have been met. (Sections 3.0 and 4.0 are complete).
4. O-S0-85-1 Control Rod Drive System Section 5.5 is complete through Step 9.

INITIATING CUES:

1. You will close the "Reactor Trip" breakers and withdraw the Shutdown Banks using O-S0-85-1, Control Rod Drive System Section 5.5, beginning with step 10.
2. Inform the SM when the shutdown banks have been withdrawn.

STEP 1

Standard:

Cue:

Examiner Note:

Comment STEP 2

Standard:

Cue:

Comment 1503 NRC Sim JPM A Page 6of19 Start Time SAT Obtain a copy of O-S0-85-1, Control Rod Drive System section 5.5 (and then section 6.3)

UNSAT Examinee obtains a copy of O-S0-85-1, Control Rod Drive System section 5.5.

Provide a marked up copy of O-S0-85-1, Control Rod Drive System section 5.5 (and then section 6.3).

Initiating conditions cover several steps in section 5.5 prior to step 10.

These steps are not addressed in the JPM.

[-W]

[CTS] IF unit is in Mode 3,THEN SAT ENSURE requirements of Tech Spec 3.4.1.2 are met

[ITS] IF unit is in Mode 3,THEN UNSAT ENSURE requirements of Tech Spec 3.4.5 are met Examinee ensures TS 3.4.1.2 requirements are met.

Provide the following cue: "The SRO has verified requirements are met."

STEP 3

Standard:

Examiner Note Comment STEP 4

Comment STEP 5

Standard:

Comment 1503 NRC Sim JPM A

[11]

DEPRESS and HOLD FW !sol Reset pushbuttons [HS-3-99A]

and [HS-3-9961-(C.1]

Examinee verifies both HS-3-99A and B, FW Isolation A & B Train Reset pushbuttons, are being held in the IN Reset position.

Have the simulator operator play role as CRO and depress both A& B FW Isolation Reset pushbuttons.

[12]

IF resetting Unit 1 Reactor Trip Breakers, THEN

[13]

CLOSE Rx Trip Breakers by placing [1-HS-99-7]. in CLOSE position.

IF resetting Unit 2 Reactor Trip Breakers, THEN CLOSE Rx Trip Breakers by placing [2-HS-99-7], in CLOSE position.

Examinee determines step is N/A.

Page 7 of 19 SAT UNSAT SAT UNSAT SAT UNSAT

STEP 6

Standard:

Comment STEP 7

Standard:

Comment STEP 8

Standard:

Cue:

Comment

[14]

VERIFY Reactor Trip Breakers CLOSED by RED indicating lights on M-4:

BREAKER RED LIGHT INITIALS POSITION INDICATION RTA ON RTB ON Examinee verifies Red indicating lights come on and green lights go off on Reactor Trip Breaker indicating lights on panel M 4.

['15]

RELEASE FVV lsol Reset pushbuttons [HS-3-99A] and

[H S-3-99Bl[C.1]

Examinee directs additional operator to release pushbuttons

[16]

NOTIFY !Ms to perform *1,2-Pl-IFT-099-0P4.0, Verification of P4 Contacts.

1503 NRC Sim JPM A Page 8 of 19 SAT UNSAT SAT UNSAT SAT UNSAT Examinee notifies IMs to perform 1,2-Pl-IFT-099-0P4.0, Verification ofP4 Contacts.

Provide the following cue: "The SRO will notify the IMs to perform this Pl."

STEP 9

Standard:

Comment STEP 10 Standard:

Comment STEP 11 Standard:

Cue:

[H]

IF Shutdown or Control Rods will be withdrawn and both MG Sets are NOT in operation but are available, THEN PERFORM one of the following AND RETURN to this Section (Mark selection NOT made NIA):

[17.1]

GO TO Section 6.1, Placing MG Set A In Service With MG Set B Operating OR

[172]

GO TO Section 6-2, Placing MG Set B In Serifice Wil:h MG Set A Operating Examinee determines both steps are N/A

[18]

IF Shutdown or Control Rods will be withdrawn, THEN GO TO Section 6-3, Manual Operation of Rod Control System Below 15 Percent PO'wer_

Em.I of Section 5.5 Examinee determines Section 6.3 is applicable.

Obtain a copy of O-S0-85-1, Control Rod Drive System section 6.3 1503 NRC Sim JPM A Page 9of19 SAT UNSAT D

D SAT UNSAT SAT UNSAT Examinee obtains a copy of O-S0-85-1, Control Rod Drive System section 6.3.

Provide a copy of O-S0-85-1, Control Rod Drive System section 6.3.

1503 NRC Sim JPM A Page 10of19 CAUTIONS

1)

[CTS] TR 3.1.3.3 [ITSJ TRM 8.1.3 requires group demand position indicator capable of determining within +/-2 steps, the demand position for each rod not fully inserted. In Modes 3, 4, or 5 and greater than +/-2 steps deviation refer to AOP-C.01.

2)

If reactor trip breakers are CLOSED and an RCS cooldown of greater than 50°F is planned, the shutdown and control banks should be withdrawn at least 5 steps each. This will limit the possibility of "thermal lock-up" of the rods. Thermal lock-up is NOT a concern during unit heatup.

NOTE When RCS temperatures are greater than 350°F, continuous rod motion shall comply with these restrictions:

CROM OUTLET ROD MOTION UMITS TEMPERATURE

s;190"f 10 minutes ON 20 minutes OFF s200'~f 6minutes ON 24 minutes OFF STEP 12 SAT

[1]

ENSURE Section 5.5, Reset/Close Reactor Trip Breakers has been completed.

D UNSAT Standard:

Examinee determines Section 5.5 is complete.

Comment STEP 13

[2]

IF the shutdown and control rods were withdrawn 5 steps to SAT prevent thermal lockup during an RCS coo[down, THEN UNSAT ENSURE rods are fuHy inserted prior to withdrav11aL Standard:

Examinee determines step is NIA.

Comment

STEP 14 Standard:

Cue:

Comment STEP 15 Comment 1503 NRC Sim JPM A Page 11 of 19

[3]

IF RCS temperatures are greater than 350°f, THEN ENSURE CROM cooling fans are aligned and in sen.rice in accordance wfth O-S0-30-6.

Examinee ensures that CROM cooling fans are aligned and in service per O-S0-30-6 Provide the following cue: "CROM cooling fans are aligned and in service per 0-50-30-6" CAUTION ROD CONTROL STARTUP STEP COUNTER RESET (SUS on M-4} should never be held in STARTUP position for any extended period of time. Holding this switch in STARTUP position may cause damage to the counters.

NOTE ROD CONTROL STARTUP STEP COUNTER RESET (SUS on M--4) Resets:

A.

All GROUP STEP COUNTERS on the Control Board.

B.

The master cyder reversible counter.

C.

All slave cycler counters.

D.

The bank overlap counter.

E.

All internal memory and alam1 circuits.

F.

All pulse-to-analog converters in the Rod Position Indication System.

[4]

MOMENTARILY PLACE [SUS]. Rod Control Startup Step Counter Reset to the STARTUP position to reset Control Rod Drive System.

SAT UNSAT SAT UNSAT

STEP 16 Standard:

Comment STEP 17 Standard:

Comment STEP 18 Standard:

Comment CAUTION 1503 NRC Sim JPM A Page 12of19 Before withdrawing any rod from the fully inserted position, all Group Step Counters and all Rod Position indicators must be at.zero steps.

SAT

[5]

ENSURE all Fun length Rod step counters reset to zero.

UNSAT Examinee verifies rod step counters have reset to zero.

SAT

[6]

VERIFY rod control IN-OUT direction lights are NOT LIT.

UNSAT Examinee verifies both IN and OUT lights NOT lit.

SAT

[7]

DEPRESS [RCAS], Rod Urgent Failure Alarm Reset UNSAT Examinee depresses RCAS, Rod Urgent Failure Alarm Reset.

STEP 19 Standard:

Comment STEP 20 Standard:

Comment 1503 NRC Sim JPM A Page 13of19

[8]

RESET Window 6 (A-6)., ROD CONTROL SYSTEM URGENT SAT FAILURE alarm on pane! [XA-55-4BJ using [XS-55-4A].

Annunciator RESET/ACKfTEST Switch_

UNSAT Examinee resets ROD CONTROL SYSTEM URGENT FAILURE alarm.

NOTE Window 13 (B-6) may be marked NIA if Shift Manager approvar is obtained for reactor startup with Non-Urgent Failure Alarm_ Risk of dropped rods (if additional failure occurs or during subsequent corrective maintenance) should be evaluated_

[9]

VERIFY the following rod control system alarms on panel SAT

[XA-55-4B] are NOT UT:

WINDOW NUMBER NOT UT('/) WINDOW NUMBER NOT LIT {..J)

UNSAT 5 (A5) 0 18 (C4) 0 6 (A6) 0

'19(C5) 0 11 {B4) 0 27 (06) 0 12 (B5) 0 34 (E6) 0 13(B6) 0 Examinee verifies that the listed annunciators are not lit

STEP 21 Standard:

Cue:

Comment STEP 22 Standard:

Cue:

Comment

[10]

ENSURE Plant computer points for rod bank position are ZERO using the following computer points:

COMPUTER PT ROD BANK U0049 Control A D

U0050 Control B D

U0051 Control C D

U0052 Control D D

U0053 Shutdown A D

U0054 Shutdown B D

U0055 Shutdown C D

U0056 Shutdown D D

1503 NRC Sim JPM A Page 14of19 SAT UNSAT Examinee ensures Plant computer points for rod bank position are ZERO Provide the following cue: "Another operator has verified Plant computer points for rod bank position are ZERO "

[*111 MONITOR Control Rod position USING Rod Position SAT Indicators ICS screen 30 minute trend during SD & Control UNSAT Banks withdrawal to aid in detecting rod misalignment.

Examinee monitors Control Rod position using Rod Position Indicators ICS screen 30 minute trend.

Provide the following cue: "Another operator will monitor Rod Position Indicators using ICS "

STEP 23 Standard:

Comment STEP 24 Standard:

Comment

[12]

IF Individual Rod Position Indication does not indicate proper rod position during withdrawal of SD Banks, THEN

[12_ 1J STOP rod withdrawaL

[12-2]

ENSURE subcriticalil:y.

(12.3]

CONTACTl&C ANO INfflATE triiubleshooting.

[12.4]

IF troubleshooting does not resolve the problem, OR subcriticality can NOT be verified, THEN INfflATE Reactor TRIP_

Examinee addresses step

[13)

IF Individual Rod Position Indication does NOT indicate proper rod position during withdrawal of Control Banks, THEN GO TO AOP-C.01, Rod Control System Malfunctions_

Examinee addresses step 1503 NRC Sim JPM A Page 15of19 SAT UNSAT SAT UNSAT

STEP 25 Comment STEP 26 Standard:

Comment 1503 NRC Sim JPM A Page 16 of 19 CAUTION Under normal conditions control rod banks must. be withdrawn and inserted in the prescribed sequence. For withdrawal, the sequence is Shutdown Bank A, Shutdown Bank B, Shutdown Bank C, Shutdown Bank D, Control Bank A, Control Bank B, Control Bank C, Control Bank D. The insertion sequence is the reverse of the withdrawal sequence.

NOTES

1)

Startup rateT Source range, Intermediate range, Nuclear Instrumentation recorders, Group Step Counters and the Rod Position Indicators should be monitored during each bank withdrawal.

2)

The following failures win render the rod control system incapable of automatic and I or manual motion 'Nithout any annunciation or indication: *t) Hand switch failure: 2) relay failure, and 3) simultaneous failure of both *t OOv DC power supplies (PS3 and PS6)

["I 4]

PLACE [HS-85-511 OJ, Rod Control Mode Selector to the SBA position_

[15]

VERIFY Rod Speed Indicator [Sl-412], indicates 64 Steps/minute_

Examinee verifies Rod Speed Indicator reads 64 Steps/minute.

SAT UNSAT SAT UNSAT

STEP 27 Examiner Note Comment STEP 28 Standard:

Comment 1503 NRC Sim JPM A Page 17 of 19 NOTE Monitor Group Step Counters, Rod Position Indicator and the "IN-OUT" status lights to ensure anticipated motion as each bank is being withdrawn. Rod speed indicator should be reading 64 steps per minute_

[16)

ENSURE Shutdown Bank A dernand position counters operational by perfonning the following: [C.2]

[16.'IJ BUMP [HS-85-51111, Rod Control Switch to withdraw Shutdown Bank A one-half step at a time, for one full step_

When Rod Control Switch is taken to OUT a malfunction will cause SDB A rods to withdraw continuously forcing ALTERNATE PATH ALTERNATE PATH When bumping SB A out SB A begins withdrawing continuously

1.

DIAGNOSE the failure:

GOTO IF...

SECTION PAGE Uncontrolled rod bank movement 2.1 4

(rod movement NOT due to actual T-avg/T-ref mismatch or change in reactor/turbine power)

Examinee recognizes continuous uncontrolled rod bank movement SAT UNSAT SAT UNSAT

STEP 29 Standard:

Comment STEP 29 Comment Terminating Cue:

1503 NRC Sim JPM A Page 18of19 2.1 Uncontrolled Rod Bank Movement NOTE:

Step 1 is an immediate action step.

1.

STOP uncontrolled rod motion:

a.

PLACE rod control in MAN.

b.

CHECK rod motion STOPPED.

b.

TRIP the reactor, and GO TO E-0, Reactor Trip or Injection.

Examinee places Rod Control in MAN and determines that rods are still moving. (Leaving Rod Control in SB A is acceptable.

2.1 Uncontrolled Rod Bank Movement NOTE:

Step 1 is an immediate action step.

1.

STOP uncontrolled rod motion:

a.

PLACE rod control in MAN.

b.

CHECK rod motion STOPPED.

b.

TRIP the reactor. and GO TO E-0, Reactor Trip or Injection.

Provide the following cue, "Another operator will complete the remaining steps of this procedure."

Stop Time End ofJPM SAT UNSAT SAT UNSAT STOP

JPM BRIEFING SHEET DIRECTIONS TO EXAMINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1. Unit 1 is in MODE 3 with Tavg at 547F and RCS pressure at 2235 psig.
2. Both M-G sets are in service.
3. All Precautions and Prerequisites of O-S0-85-1, Control Rod Drive System have been met. (Sections 3.0 and 4.0 are complete).
4. O-S0-85-1 Control Rod Drive System Section 5.5 is complete through Step 9.

INITIATING CUES:

1. You will close the "Reactor Trip" breakers and withdraw the Shutdown Banks using O-S0-85-1, Control Rod Drive System Section 5.5, beginning with step 10.
2. Inform the SM when the shutdown banks have been withdrawn.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPM B

RO/SRO JOB PERFORMANCE MEASURE Task:

Respond to loss of all charging per AOP-M.09.

Task#:

0040020101 2015 NRC SIM JPM B Page 2of14 Task Standard:

The examinee will depressurize the RCS to facilitate SI Pump flow using AOP-M.09 LOSS OF CHARGING.

Alternate Path:

YES:

NO:

x Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

APE 022AA1.03 (3.2/3.2)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

20 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS:

1. Ensure Simulator Operator Checklist is complete
2. Reset to IC 275
3.

If IC 275 is not available perform the following:

Reset to IC 16.

Trip the Reactor.

Place both Charging Pump HS in PTL.

Establish AFW flow at approx. 600 gpm.

Place Steam Dumps in STEAM PRESSURE MODE.

Isolate Letdown.

Ensure Pressurizer Level is 25%.

Ensure T Hot is less than 550 deg.

Perform G0-12

4. PLACE SIMULATOR IN RUN
5. An extra operator will be required to acknowledge alarms.
6. ACKNOWLEDGE ALARMS
7.

FREEZE SIMULATOR.

8. Save as a temporary IC, if repeat runs of JPM will be desired.
9.

PLACE SIMULATOR IN RUN 2015 NRC SIM JPM B Page 3of14

10. After JPM is complete, delete the temporary IC, if used. Delete the contents of the recycle bin, If a temporary IC has been deleted.

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

1. In-progress copy of AOP-M.09 LOSS OF CHARGING completed through step 29.

References:

Reference Title Rev No.

1.

AOP-M.09 LOSS OF CHARGING 6

2.

DIRECTIONS TO TRAINEE:

2015 NRG SIM JPM B Page 4of14 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 3.

2.

Both Charging pumps are unavailable.

3.

ES-0.1, REACTOR TRIP RESPONSE has been completed.

4.

AOP-M.09, LOSS OF CHARGING is in progress, completed through step 28.

INITIATING CUES:

1.

The SRO has directed you to complete AOP-M.09, LOSS OF CHARGING starting at step 29.

2.

Inform the SRO when complete.

STEP 1

Standard:

Cue:

Comment CAUTION STEP 2

Standard:

Comment 2015 NRC SIM JPM B Page 5of14 Start Time SAT Obtain a copy of AOP-M.09, LOSS OF CHARGING UNSAT Examinee obtains a copy of AOP-M.09, LOSS OF CHARGING Provide an in-progress copy of AOP-M.09, LOSS OF CHARGING.

If RCS temperature is less than 350°F, operating an SI pump in later steps would violate requirements of Tech Spec LCO 3.4.12 {LTOPS).

SAT

29.

MONITOR RCS T-cold greater than 350"'F.

UNSAT The examinee determines RCS temperature is greater than 350 deg by observing plant instrumentation.

NOTE STEP 3

Standard:

Comment STEP 4

Standard:

Comment 2015 NRC SIM JPM B Page 6of14 SI actuation is NOT necessary when RCS pressure is deliberately lowered to allow SI pump injection in later steps.

30.

MONITOR if SI signal actuation SAT is needed:

a.

CHECK for any of the following:

a.

GO TO Step 31.

UNSAT

~

containment pressure greater than 1.5 psig OR uncontrolled drop in RCS pressure to less than 1870 psig OR uncontrolled drop in SIG pressure to less than 600 psig.

The examinee determines SI is not required by observing plant instrumentation.

31.

MONITOR if SI pump injection is needed:

SAT

a.

CHECK for any of the following:

UNSAT RCS boration is required to maintain shutdown margin or to prepare for RCS cooldown OR pressurizer level less than 25%

OR pressurizer level needs to be raised to support RCS cooldown.

The examinee determines SI is pump injection is required by observing Pressurizer level< 25%.

STEP 5

Standard:

Comment STEP 6

Standard:

Comment CAUTION STEP 7

Standard:

Comment 2015 NRC SIM JPM B Page 7 of 14 SAT

32.

CHECK T-hot less than 550°F.

UNSAT The examinee determines RCS temperature is less than 550 deg by observing plant instrumentation.

33.

CHECK low pzr pressure SI signal SAT NOT blocked:

UNSAT permissive M-4A window B-4 DARK.

The examinee determines the Low Pressure SI signal not blocked by observing permissive M-4A window B-4 DARK.

Low pressurizer pressure SI actuation circuits will automatically unblock if pressurizer pressure rises to greater than 1970 psig.

34.

REDUCE pzr pressure to 1920 psig SAT to allow SI block:

DE-ENERGIZE pressurizer heaters.

UNSAT

a.

The examinee turns all Pressurizer heaters off by placing HS-68-341A to OFF, 341 D in OFF, 341 F in OFF or PTL and 341 H to OFF.

STEP 8

Standard:

Comment STEP 9

Comment

34.

REDUCE pzr pressure to 1920 psig to allow SI block:

b. CHECK RCPs RUNNING.

2015 NRC SIM JPM B Page 8of14 SAT UNSAT The examinee determines the RCPs running by observing red lights above HS-68-SA, 31A, 50A, and 73A Reactor Coolant Pump 1, 2, 3, and 4 ON.

34.

REDUCE pzr pressure to 1920 psig to allow SI block:

c.

OPERATE normal spray valves as necessary to reduce pzr pressure to approximately 1920 psig.

SAT UNSAT

STEP 10 Comment STEP 11 Standard:

Comment

34.

REDUCE pzr pressure to 1920 psig to allow SI block:

34.
d. BLOCK Low pressurizer pressure SI signal.

REDUCE pzr pressure to 1920 psig to allow SI block:

e.

CHECK PRESSURIZER SI TRAINS A&B BLOCKED permissive UT

[M-4A, 84].

2015 NRC SIM JPM B Page 9of14 SAT UNSAT SAT UNSAT The examinee determines the SI Low Pressure Blocked by observing PRESSURIZER SI TRAINS A&B BLOCKED permissive LIT [M-4A, B4].

CAUTION 1 Pressurizer level may rise rapidly when RCS pressure is below St pump shutoff head.

CAUTION 2 Operation of SI pump with recirc flowpath isolated could result in pump damage.

STEP 12 SAT

35.

ENSURE one SI pump running.

UNSAT Comment

NOTE STEP 12 Comment 2015 NRC SIM JPM B Page 10of14 To allow injecting with SI pump, RCS subcooling may temporarily be reduced below required value in ES-0.2 or ES-0.3 (if applicable). Manual SI actuation based upon low subcooling is NOT required as long as operators retain control over RCS pressure.

36.

CONTINUE RCS depressurization UNTIL SI pump begins to inject:

a.

ENSURE discharge valve OPEN for running SI pump:

FCV-63-152 (Train A)

OR FCV-63-153 (Train B)

b.

PERFORM one of the following as necessary to reduce RCS pressure:

OPERATE one pzr PORV OR OPERATE normal spray valves.

SAT UNSAT

STEP 13 Comment 36_

CONTINUE RCS depressurlzation UNTIL SI pump begins to inject

c.

WHEN SI pump begins to inject AND pzr level is rising, THEN STOP RCS depressurization.

2015 NRC SIM JPM B Page 11 of 14 SAT UNSAT

STEP 14 Comment 36_

CONTINUE RCS depressurization UNTll SI pump begins to inject d_

CONTROL RCS pressure to maintain desired injection rate_

2015 NRC SIM JPM B Page 12of14 SAT UNSAT

NOTE1 NOTE2 STEP 15 Comment 2015 NRC SIM JPM B Page 13of14 Normal requirement for running SI pump at least 20 minutes does NOT apply in this AOP_

Normal motor starting limitations are NOT applicable in thrs AOP_ However, pump stop/start cycles should be limited as much as possible to minimize potential for overheating motor windings_

37 _

WHEN pressurizer level reaches 65%

or desired value, THEN PERFORM the following:

a. TERMINATE SI pump injection:

STOP running SI pump OR CLOSE Sl pump discharge valve FCV-63-152 (Train A) or FCV-63-153 (Train B)_

Examiner may direct the examinee to terminate the fill at the Examiner's discretion.

SAT UNSAT Terminating Provide the following cue, "Another operator will complete the STOP Cue:

remaining steps of this procedure."

Stop Time ----

JPM BRIEFING SHEET The examiner will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 3.

2.

Both Charging pumps are unavailable.

3.

ES-0.1, REACTOR TRIP RESPONSE has been completed.

4.

AOP-M.09, LOSS OF CHARGING is in progress, completed through step 28.

INITIATING CUES:

1.

The SRO has directed you to complete AOP-M.09, LOSS OF CHARGING starting at step 29.

2.

Inform the SRO when complete.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPMC

RO/SRO JOB PERFORMANCE MEASURE Task:

Isolate the Ruptured Steam Generator (With MSIV Failure to Close)

Task#:

0000380501 1503 NRC Sim JPM C Page 2 of 14 Task Standard:

The examinee isolates Steam Generator #1 with a failed #1 MSIV using E-3 Steam Generator Tube Rupture Alternate Path:

YES:

x NO:

Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

EPE 038 EA1.32 (4.6/4.7)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

15 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS:

1. Ensure Simulator Operator Checklist is complete
2.

Reset simulator to IC #265.

3. If IC is unavailable, then Initialize simulator in IC# 16 and Insert the following:

a) Activate malfunction IMF TH05A f:8.5 to initiate S/G tube rupture in S/G #1.

b) Activate malfunction IMF MS14A f:100, to fail open SIG Loop 1 MSIV.

1503 NRC Sim JPM C Page 3 of 14 c) Actuate a MANUAL reactor trip and safety injection, take all actions up through Step 3 of E-3.

d) Complete the actions of E-0 thru step 12, which will transition the crews to E-3 e) Complete any required actions in ES-0.5. Including closing the TD AFW LCVs, but do not put handswitches in pull-to-lock.

f)

Complete the first three steps in E-3.

4. An extra operator will be required to acknowledge alarms.
5. ACKNOWLEDGE ALARMS
6. FREEZE SIMULATOR.
7. Provide a copy of E-3 STEAM GENERATOR TUBE RUPTURE
8. PLACE SIMULATOR IN RUN SPECIAL INSTRUCTIONS TO EVALUATOR:
1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Eg u ipment/Proced u res Needed:

1. In progress copy of E-3, STEAM GENERATOR TUBE RUPTURE

References:

Reference Title Rev No.

1.

E-3 STEAM GENERATOR TUBE RUPTURE 21

DIRECTIONS TO EXAMINEE:

1503 NRC Sim JPM C Page 4of14 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1.

Unit 1 has experienced a Steam Generator Tube Rupture on Steam Generator #1.

2.

A manual safety injection was initiated.

3.

E-3, STEAM GENERATOR TUBE RUPTURE is in progress, steps 1 through 3 of E-3 have been completed INITIATING CUES:

1.

You have been directed to continue with E-3, STEAM GENERATOR TUBE RUPTURE beginning at Step 4.

2.

Inform the SRO when you have isolated the #1 Steam Generator.

STEP 1

Standard:

Cue Comment Procedure Caution:

STEP 2

Comment 1503 NRC Sim JPM C Page 5 of 14 Start Time Obtain a copy of E-3, STEAM GENERATOR TUBE RUPTURE Examinee obtains a copy of E-3, STEAM GENERATOR TUBE RUPTURE Provide a marked up copy of E-3, STEAM GENERA TOR TUBE RUPTURE completed through step 3.

CAUTION If the TD AFW pump is the only source of feed flow, isolating both steam supplies will result in loss of secondary heat sink.

4_

ISOLATE flow from Ruptured S/G(s):

a_

ADJUST Ruptured S/G(s) atmospheric relief controller setpoint to 87% in AUTO_ ('1040 psig)

SAT UNSAT SAT UNSAT

STEP 3

Standard:

Comment STEP 4

Standard:

Comment STEP 5

Comment 4_

ISOLA TE flow from Ruptured S/G(s):

b_

CHECK Ruptured S/G{s) atmospheric relief hand switch in P-AUTO and valve(s) CLOSED.

1503 NRC Sim JPM C Page 6of14 SAT UNSAT Examinee observes SIG #1 atmospheric relief handswitch, 1-HS-1-6, on 1-M-4 in P-AUTO and valve CLOSED.

4_

ISOLATE flow from Ruptured S/G(s):

C.

CHECK SIG #1 or #4 ruptured_

Examinee observes steam generator #1 level rising with no feed or by referring to the initial conditions.

4_

ISOLATE flow from Ruptured S/G(s):

d_

CLOSE TD AFW pump steam supply from Ruptured SIG FCV-'l-'15 (S/G #'t) or FCV-1-16 (SIG #4)_

SAT UNSAT SAT UNSAT

STEP 6

Standard:

Comment STEP 7

Standard:

Comment Examiner Note 4_

ISOLATE flow from Ruptured S/G(s):

e_

VERIFY Ruptured S/G(s) blowdown isolation valves CLOSED_

Examinee observes FCV-1-7 and FCV-1-181 CLOSED green indication lights above handswitch 1-HS-1-71181 on 1-M-4 ON.

4_

ISOLATE flow from Ruptured SlG(s):

f_

CLOSE Ruptured S/G(s) l'V1SIV and MSIV bypass valve_

Examinee places 1-HS-1-4 SIG #1 MSIV to CLOSE. Recognizes MSIV FCV-1-4 failed to close, by the red light above 1-HS-1-4 ON, and goes to the RNO to isolate the SIG.

1503 NRC Sim JPM C Page 7of14 SAT UNSAT SAT UNSAT SIG #1 MSIV will NOT close and the operator MUST go to the RNO column

STEP 8

Comment STEP 9

Standard:

Cue Comment 1503 NRC Sim JPM C Page 8 of 14 Alternate path 4_

ISOLATE flow from Ruptured S/G(s):

f _ PERFORM the foHowing:

1) CLOSE Intact SIG l'vlSIVs and MSIV bypass valves.

(Not Critical) Examinee verifies MSIV bypasses closed by observing green lights ON above handswitch 1-HS-1-148, 1-HS-1-149, & 1-HS-1-150 MSIV bypass valves.

4_

ISOLATE flow from Ruptured SIG(s):

f_

PERFORM the following:

2) DISPATCH operator to perform EA-1-1, Closing l'VlSIVs Locally, for any l\\11SIV or l'v1SIV bypass valve which fails to close.

Examinee dispatches an operator to perform EA-1-1, Closing MS I Vs Locally, for #1 S/G MSIV.

Acknowledge the direction from the examinee.

SAT UNSAT SAT UNSAT

STEP 10 Comment STEP 11 Standard:

Comment 4_

4_

ISOLATE ftow from Ruptured S/G(s):

t PERFORM the following:

f_

3) ISOLATE steam header:

PLACE condenser steam dumps in OFF_ [M-4]

ISOLATE flow from Ruptured S/G{s):

PERFORM the following:

3) ISOLATE steam header:

ENSURE steam dump valves CLOSED_ [M-4]

Examinee verifies the steam dump valves are closed by observing 1503 NRC Sim JPM C Page 9 of 14 SAT UNSAT SAT UNSAT green light indication on 1-XX-55-4A for all steam dump valves are ON

STEP 12 Comment STEP 13 Standard:

Comment 4_

4_

ISOLATE flow from Ruptured S/G(s):

f.

PERFORM the following:

f_

3) ISOLATE steam header:

CLOSE FCV-47-180, HP Steam Seal Supply Isolation_ [M-21 ISOLATE flow from Ruptured S/G(s):

PERFORM the following:

3) ISOLATE steam header:

ENSURE FCV-47-'18'1 HP Steam Seal Supply Bypass CLOSED_ [M-2]

Examinee verifies FCV-47-181 HP Steam Seal Supply Bypass 1503 NRC Sim JPM C Page 10 of 14 SAT UNSAT SAT UNSAT CLOSED by observing green light indication above the handswitch to ON.

STEP 14 Comment STEP 15 Standard:

Cue Comment

4.

4_

ISOLA TE flow from Ruptured S/G(s):

f_

PERFORM the following:

f_

3) ISOLATE stearn header:

CLOSE MSR HP steam supply isolation valves_ [M-2]

ISOLATE flow from Ruptured S/G(s):

PERFORM the following:

3) ISOLATE steam header:

DISPATCH operator to locally isolate steam header USING EA-1-4, Local Isolation of Steam Header in Turb Bldg_

Examinee dispatches an operator to locally isolate steam header USING EA-1-4, Local Isolation of Steam Header in Turb Bldg.

Acknowledge the direction from the examinee.

1503 NRC Sim JPM C Page 11 of 14 SAT UNSAT SAT UNSAT

STEP 16 4_

ISOLATE flow from Ruptured S/G(s):

f_

PERFORM the following:

4) USE Intact S/G(s) atmosphenc relief for steam dump_

Standard:

Examinee addresses the procedure step.

Comment STEP 17 5_

MONITOR Ruptured S/G(s) level:

a_

CH ECK ruptured SIG narrow range level greater than 10% [25'!to ADV]_

Examinee verifies #1 SIG narrow range level greater than 10% by Standard:

observing Ll-3-42, or Ll-3-39, or Ll-3-38 or other installed plant instrumentation.

Comment STEP 18 5_

MONITOR Ruptured S!G(s) level:

b. ISOLATE APN to ruptured SIG:
1) ENSURE AFW LCVs for ruptured SIG are CLOSED.

Comment 1503 NRC Sim JPM C Page 12 of 14 SAT UNSAT SAT UNSAT SAT UNSAT

STEP 19 Standard:

Comment Terminating Cue:

5_

MONITOR Ruptured S/G(s) level:

b_

ENSURE AFW isolated to ruptured SIG:

2} PLACE Turbine Driven AFW LCV for ruptured SIG in CLOSE PULL TO LOCK.

1503 NRC Sim JPM C Page 13 of 14 SAT UNSAT Examinee places 1-HS-3-174A Turbine Driven AFW LCV for #1 SIG to CLOSE PTL.

Provide the following cue "Another operator will perform the STOP remaining steps of this procedure."

Stop Time ----

JPM BRIEFING SHEET The examiner will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

INITIAL CONDITIONS:

1.

Unit 1 has experienced a Steam Generator Tube Rupture on Steam Generator #1.

2.

A manual safety injection was initiated.

3.

E-3, STEAM GENERATOR TUBE RUPTURE is in progress, steps 1 through 3 of E-3 have been completed INITIATING CUES:

1.

You have been directed to continue with E-3, STEAM GENERATOR TUBE RUPTURE beginning at Step 4.

2.

Inform the SRO when you have isolated the #1 Steam Generator.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPM D

RO/SRO JOB PERFORMANCE MEASURE Task:

Start a Reactor Coolant Pump Task#:

0030010101 Task Standard:

The Operator manually stops the #1 Reactor Coolant Pump.

Alternate Path:

YES:

x NO:

Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

APE 015/017 AA1.03 (3.7/3.8)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature Performance Rating:

SAT:

UNSAT:

Validation Time:

15 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS 1503 NRC Sim JPM D Page 2of16 DATE

SPECIAL INSTRUCTIONS:

1)

Ensure Simulator Operator Checklist is complete

2)

Initialize to IC 268

3)

IF IC 268 is not available Then initialize to IC 7 and perform the following a) Stop the #1 RCP.

b) Place MODE 3 sign on Panel M-4 c) Insert AN_OV _359 to OFF (Disables Loose Parts Alarm.)

d) Close the Loop 1 Pressurizer Spray valve

4)

Set NR-45 to display one SRM and one IRM

5)

An extra operator will be required to acknowledge alarms.

6)

ACKNOWLEDGE ALARMS

7)

FREEZE SIMULATOR.

1503 NRC Sim JPM D Page 3of16

8)

Provide a marked up procedure 1-S0-68-2, Reactor Coolant Pumps Section 5.1 completed through step 10 and Appendix D.)

9)

PLACE SIMULATOR IN RUN

10)

Booth operator standby to insert the SCN File RCPHEATUP.scn (from exams folder) during the JPM

11)

Go to SCENS

12)

GO Exam folder

13)

Run SCN File RCPHEA TUP when the #1 RCP is started SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

1. In progress copy of 1-S0-68-2 Reactor Coolant Pumps

References:

Reference Title

1.

1-S0-68-2 Reactor Coolant Pumps

2.

AOP-R.04 Reactor Coolant Pump Malfunctions 3

1-AR-M5-B CVCS Seal Water and RCP Rev No.

39 27 41

DIRECTIONS TO EXAMINEE:

1503 NRC Sim JPM D Page 4 of 16 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 3

2.

Preparations are being made to start #1 RCP.

3.

All precautions and prerequisites are complete.

4.

1-S0-68-2, Reactor Coolant Pumps Section 5.1, steps 1 through 1 O are complete.

5.

All other RCPs are in service INITIATING CUES:

1.

You have been directed to start and monitor the #1 RCP using 1-S0-68-2, Reactor Coolant Pumps starting at step 5.1.11.

2.

Notify the SRO when you are complete.

STEP 1

Standard:

Cue Comment STEP 2

Comment Examiner Note 1503 NRC Sim JPM D Page 5 of 16 Start Time Obtain a copy of 1-S0-68-2, Reactor Coolant Pumps Section 5.1 completed through step 10.

Examinee obtains a copy of 1-S0-68-2, Reactor Coolant Pumps Section 5.1.

Provide a marked up copy of 1-S0-68-2, Reactor Coolant Pumps Section 5.1 completed through step 10.

[11] PLACE [1-HS-68-84AJ #1 RCP Lift Oil Pump in the ST ART position.

REAC COOL PMPS OIL LIFT PRESS LOW annunciation will come in and clear during performance of the next step SAT UNSAT SAT UNSAT

STEP 3

Standard:

Comment STEP 4

Standard:

Comment STEP 5

Comment

[12] WHEN Lift Oil Pump for #1 RCP has run

~ 2 minutes, THEN ANNOUNCE #1 RCP start on the PIA system.

Examinee addresses the procedure step.

[13] IF no RCPs are running AND RCP #1 is the first RCP to be started, THEN MONITOR the SRMs during startup of the RCP. [C.3]

1503 NRC Sim JPM D Page 6 of 16 SAT UNSAT SAT UNSAT Examinee determines other 3 RCPs are running and marks this step as N/A.

SAT

[14] PLACE [1-HS-68-8Al #1 RCP in the START position.

UNSAT

Procedure Note STEP 6

Standard:

Comment Examiner Note Cue STEP 7

Standard:

Comment 1503 NRC Sim JPM D Page 7 of 16 NOTE Motor and Pump Operating Parameters are listed in Appendix D. Appendix E provides vibration limits if pump is started after maintenance activities.

SAT

[15] ENSURE #1 RCP motor and pump are operating within the parameters listed in Appendix D.

UNSAT Examinee monitors #1 RCP motor and pump parameters using installed instrumentation.

The motor will start heating up and result in the REAC COOL PMPS MOTOR STATOR TEMPERATURE HIGH alarm on 1-M-5, Window E-1 on 1-XA-55-58 coming in during the performance of the next steps (JPM steps 6-7; procedure steps 15-17). When alarm comes in, the operator may not complete performing procedure step 15, 16 or

17. N/A those steps if applicable and move on to JPM step 9 if the examinee transitions to alarm procedure.

If the examinee starts to go to the back panels to monitor parameters provide the following cue, "Another operator will perform Appendix D for parameters on the back panels."

[16] ENSURE [1-TCV-67-86] RCP Motor Cooler 1A is SAT OPEN (1-HS-67-86 red light illuminated).

UNSAT Examinee verifies 1-TCV-67-86 is open on Panel M-27A by observing the red indicating light above handswitch ON.

STEP 8

Standard:

Comment STEP 9

Standard:

Comment Examiner Note 1503 NRC Sim JPM D Page 8 of 16

[17] WHEN Lift Oil Pump has run greater than 1 minute after SAT RCP start, THEN PLACE [1-HS-68-84Al #1 RCP Lift Oil Pump in UNSAT the STOP position.

Examinee places 1-HS-68-84A #1 RCP Lift Oil Pump handswitch to STOP Panel 1-M-5 SAT 29 (E-1)

UNSAT REAC COOL PMPS MOTOR STATOR TEMPERATURE HIGH Examinee acknowledges alarm and observes rise in RCP motor stator temperatures.

If the actions contained in the Annunciator Response Procedure (ARP) are implemented, JPM steps 11-24 cover the actions directed by the ARP and AOP to stop the RCP. If RCP is stopped without implementing the ARP, JPM 10 step will end the JPM.

STEP 10 STOP Loop 1 RCP If the examinee stops the RCP now provide the following cue, 1503 NRC Sim JPM D Page 9of16 SAT UNSAT Cue "Another operator will perform the remaining steps of this procedure."

Comment Examiner The following steps are from the Annunciator Response Procedure 1-Note AR-M5-B.

NOTE RCP 1-4 is known to have high winding temperature (up to Procedure approximately 303°f when running with RCS temperature below Note 400°F. (EWR 10-COM-068-057)) However, alarms on RCP 1-4 should NOT be dismissed as "expected".

STEP 11 Corrective

[1} DETERMINE which pump is in alarm by monitoring computer SAT Actions points.

Pump i: Point T0409A, 4"11Aor412A (A,B, & C 0)

Pump 2: Point T0429A, 431 A or 432A (A,B, & C 0)

UNSAT Pump 3: Point T0449A, 451A or 452A (A.B, & C 0)

Pump 4: Point T0469A, 471A or 472A (A,B, & C 0)

Standard:

Examinee determines the #1 RCP in alarm by observing the ICS display.

Comment

STEP 12

[2] CONT ACT Engineering to obtain engineering assistance in determining the validity of the alarm.

Standard:

Engineering is contacted to obtain engineering assistance in determining the validity of the alarm.

Cue Respond as Unit Supervisor "Engineering has been contacted and has validated the alarm."

Comment STEP 13

[3] MONITOR the following parameters for increasing trends:

a. Motor Current
b. Bearing Temperatures
c. Pump/Motor Vibrafion
d. Containment Air Temperatures Examinee monitors or directs monitoring parameters by observing Standard:

indications on installed instrumentation and determines indications normal.

Comment 1503 NRC Sim JPM D Page 10of16 SAT UNSAT SAT UNSAT

STEP 14 Standard:

Comment Examiner Note STEP 15 Standard:

Comment STEP 16 Standard:

Comment 1503 NRC Sim JPM D Page 11 of 16 SAT

[4] ENSURE ERCW aligned to pump cooler.

UNSAT Examinee verifies ERCW aligned to pump cooler by observing red light above 1-HS-67-86 on O-M-27A ON.

May have been performed in JPM step 7.

SAT

[5] VERIFY ERCW system temperature and pressure normal.

UNSAT Examinee verifies ERCW system temperature and pressure normal by observing indications O-M-27 A.

SAT

[6] VERJFY lowe:r compartment ajr temperature normat UNSAT Examinee verifies lower compartment air temperature normal by observing indications on ICS and other installed plant instrumentation.

STEP 17 Standard:

Comment Examiner Note STEP 18 1503 NRC Sim JPM D Page 12 of 16 SAT

[7] REFER TO 1-S0-68-2 for RCP operating limits_

UNSAT Examinee refers to 1-S0-68-2, Reactor Coolant Pumps Appendix D for the operating limits.

If the remaining actions contained in the Annunciator Response Procedure (ARP) are implemented, JPM steps 19-20 cover the actions directed by the ARP and AOP to stop the RCP. If RCP is stopped at this point, JPM 18 step will end the JPM.

STOP Loop 1 RCP SAT UNSAT If the examinee stops the RCP now provide the following cue, Cue "Another operator will perform the remaining steps of this procedure."

Comment

STEP 19 Standard:

Comment STEP 20 Standard:

Cue Comment STEP 21 Standard:

Comment 1503 NRC Sim JPM D Page 13 of 16

[8] IF Ops/Engineering determines alarm is valid, THEN SAT PERFORM the following:

[a] CHECK pump motor amps_ (normal 415 amps with 608 amps

-- UNSAT maximum.)

(b] IF RCP motor amps approach 608 amps, THEN GO TO AOP-R.04, Reactor Coolant Pump Malfunctions.

Examinee verifies pump amps normal by observing El-68-8 less than 400 amps.

[9] IF Ops/Engineering determines alarm is valid and pump motor SAT stator temperature approaches 3*11°F (329°F for RCS temperature less than 540°F), THEN UNSAT GO TO AOP-R.04, Reactor Coolant Pump Malfunctions.

Examinee observes the motor winding temperature is greater than 311°F using the ICS and goes to AOP-R.04.

Respond as Engineering "Alarm is valid."

1.

DIAGNOSE the failure:

SAT UNSAT II Motor Stator Temperature High on ANY RCP I

2.6 I

24 II Examinee goes to AOP-R.04 section 2.6 or 2.1

Procedure Caution Procedure Note STEP 22 Standard:

Comment Procedure Caution STEP 23 Standard:

Comment 1503 NRC Sim JPM D Page 14 of 16 CAUTION:

Operating the RCP with excess winding temperature will reduce the expected life of the motor insulation.

NOTE:

RCP motor winding temperature limits are as follows:

329°F if RCS temperature is less than 540°F.

3 *1*1°F if RCS temperature is greater than or equal to 540°F.

Alternate Path SAT

'I.

MONITOR RCP Motor Stator temperature

a.

IF RCP Motor Stator temperature less than applicable limit by monitoring reaches applicable limit UNSAT the following computer points:

AND indication is verified valid, Pump 1: T0409A, 411A or 412A THEN PERFORM the following:

. Pump 2: T0429A, 431A or 432A

. Pump 3: T0449A, 451A or 452A

1)

IF reactor power less than 20%,

THEN

  • Pump 4: T0469A, 471A or 472A GO TO Section 2.1, ANY RCP Tripped or RCP Shutdown Required. [C.1J Examinee determines the motor winding temperature is greater than 311°F by observing the ICS and goes to the RNO column and ultimately to Section 2.1.

2.1 ANY RCP Tripped or RCP Shutdown Required CAUTION:

A rapid drop in level and steam flow on the affected loop SIG may occur when RCP is stopped.

1.

CHECK unit in Mode *1 or 2.

STOP affected RCP(s).

SAT Time:

UNSAT GO TO Caution prior to Step 3.

-=--

Examinee determines the Unit is in MODE 3 and proceeds to RNO

STEP 24 Comment Terminating Cue:

1.

CHECK unit in Mode 1 or 2.

STOP affected RCP(s).

Time: ___

1503 NRC Sim JPM D Pa e 15of16 SAT UNSAT GO TO Caution prior to Step 3.

Provide the following cue "Another operator will perform the remaining steps of this procedure."

STOP Stop Time ___

JPM BRIEFING SHEET I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 3

2.

Preparations are being made to start #1 RCP.

3.

All precautions and prerequisites are complete.

4.

1-S0-68-2, Reactor Coolant Pumps Section 5.1, steps 1 through 1 O are complete.

5.

All other RCP's are in service INITIATING CUE:

1.

You have been directed to start and monitor the #1 RCP using 1-S0-68-2, Reactor Coolant Pumps starting at step 5.1.11.

2.

Notify the SRO when you are complete.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPM E

RO/SRO JOB PERFORMANCE MEASURE 2015 NRC SIM JPM E Page 2 of 9 Task:

Respond to uncontrolled depressurization of all Steam Generators per ECA-2.1.

Task#:

3310100601 Task Standard:

The examinee will reduce AFW flow to all Steam Generators to less than 60 gpm but with positive flow > 30 gpm as indicated on all Steam Generators.

Alternate Path:

YES:

NO:

x Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

EPE-E12 EA-1.1 (3.8/3.8)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

10 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS:

1. Ensure Simulator Operator Checklist is complete
2. Reset to IC 276
3. If IC 276 is not available perform the following:

Reset to IC 16.

IMF MS04A f:1 IMF MS04B f:1 IMF MS04C f:1 IMF MS04D f:1 IMF MS01A f:100 PLACE SIMULATOR IN RUN Trip the Reactor.

When T Cold has reached 470 deg, FREEZE SIMULATOR.

4. PLACE SIMULATOR IN RUN
5. Trip the Reactor.
6. An extra operator will be required to acknowledge alarms.
7. ACKNOWLEDGE ALARMS
8. When T Cold has reached 470 deg, FREEZE SIMULATOR.
9. Save as a temporary IC, if repeat runs of JPM will be desired.
10. PLACE SIMULATOR IN RUN 2015 NRC SIM JPM E Page 3 of 9
11. After JPM is complete, delete the temporary IC, if used. Delete the contents of the recycle bin, If a temporary IC has been deleted.

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

References*

Reference Title

1.

ECA-2.1 UNCONTROLLED DEPRESSURIZA TION OF ALL STEAM GENERATORS Rev No.

11

DIRECTIONS TO TRAINEE:

2015 NRC SIM JPM E Page 4 of 9 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1.

An event occurred 15 minutes ago on Unit 1 which resulted in a trip.

2.

The crew has completed all applicable steps of E-2, Faulted Steam Generator Isolation and FR-Z.1 High Containment Pressure.

3.

The crew transitioned to ECA-2.1, UNCONTROLLED DEPRESSURIZA TION OF ALL STEAM GENERATORS.

4.

Operators have been dispatched in attempt to close MSIVs using EA-1-1, Closing MSIVs Locally.

INITIATING CUES:

1.

The SRO has directed you to perform ECA-2.1, UNCONTROLLED DEPRESSURIZA TION OF ALL STEAM GENERATORS starting at step 1.

2.

Inform the SRO when complete.

STEP 1

Standard:

Comment CAUTION NOTE STEP 2

Standard:

Examiner Note:

Comment 2015 NRC SIM JPM E Page 5 of 9 Start Time SAT Obtain a copy of ECA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS UNSAT Examinee obtains a copy of ECA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS Isolating both steam supplies to the TD AFW pump when it is the only source of feed flow will result in loss of secondary heat sink.

This procedure has a foldout page.

SAT NOTE This procedure has a foldout page.

UNSAT The examinee reviews the Foldout Page.

The Foldout Page items are on the next page. The Examinee should not take any actions as a result of the Foldout Page.

FOLDOUT PAGE SI REINITIATION CRITERIA IF either of the following conditions occurs:

RCS subcooling based on core exit T/Cs less than 40°F, OR Pressurizer level CANNOT be maintained greater than 10% [20% ADV],

THEN RAISE ECCS flow by performing one or both of the following:

ESTABLISH CCPIT flow USING Appendix C START CCPs or SI pumps manually as necessary.

EVENT DIAGNOSTICS IF both trains of shutdown boards deenergized, THEN GO TO ECA-0.0, loss of All AC Power.

2015 NRC SIM JPM E Page 6 of 9 IF any SIG pressure rises at any time AND Steps 15 through 25 are NOT in progress, THEN RAISE AFW flow to intact S/G as necessary and GO TO E-2. Faulted Steam Generator Isolation.

IF any S/G has level rising in an uncontrolled manner or has abnormal radiation, THEN

a. RAISE ECCS flow by performing one or both of the following as necessary:

ESTABLISH CCPIT flow USING Appendix C START CCPs or SI pumps manually as necessary.

b. GO TO E-3, Steam Generator Tube Rupture.

TANK SWITCHOVER SETPOINTS IF CST level less than 5%,

THEN ALIGN AFW suction to ERCW.

IF RWST level less than 27%,

THEN GO TO ES-1.3, Transfer to RHR Containment Sump.

STEP 3

Standard:

Cue Comment STEP 4

Standard:

Comment 2015 NRC SIM JPM E Page 7 of 9

1.

CHECK secondary pressure boundary:

SAT

a. CHECK the following:
a. CLOSE valves to restore pressure boundary on at least one S/G.

UNSAT

  • MSIVs and MSIV bypass valves CLOSED IF valves CANNOT be closed, THEN

. MFW regulating valves and DISPATCH personnel to close valves reg bypass valves CLOSED locally, one loop at a time:

  • MFW isolation valves CLOSED

. CLOSE MSIV and bypass valve as necessary USING EA-1-1,

. Atmospheric reliefs CLOSED Closing MSIVs Locally.

. SIG blowdown valves CLOSED.

  • !SOLA TE S/G atmospheric relief valve as necessary USING EA-1-2, Local Control of S/G PORVs.

. CLOSE additional feedwater or condensate MOVs as necessary.

  • ISOLATE blowdown locally as necessary.

The Examinee Checks the MSIVs are OPEN and cannot be closed.

The examinee addresses the Step 1 a RNO actions.

When asked provide the following cue, "Time has been compressed operators report the MSIVs cannot be closed using EA-1-1."

SAT

1.
b. CHECK MD AFW pumps RUNNING.

UNSAT The Examinee checks MD AFW pumps running as indicated by red light above HS-3-11 SA and 128A AFW Pump 1 A-A and 1 B-B ON.

STEP 5

Comment NOTE STEP 6

Comment Terminating Cue:

2015 NRC SIM JPM E Page 8 of 9 c

CLOSE TD AFW pump steam supply valve FCV-1-17 or FCV-1-18.

Reducing total feed flow to less than 440 gpm, as directed in this procedure, does NOT require implementation of FR-H.1, Loss of Secondary Heat Sink, as long as a total feed flow capability of 440 gpm is available.

2.

CONTROL feed flow to minimize RCS cooldown:

a. CHECK T-cold cooldown rate less than 100°F/hr.
a. REDUCE feed flow to 50 gpm to each S/G.

OPEN MD AFW pump recirc valves FCV-3-400 and FCV-3-401 as necessary to control flow.

GO TO Substep 2.c {AER column).

SAT UNSAT SAT UNSAT Provide the following cue, "Another operator will complete the remaining steps of this procedure."

STOP Stop Time

JPM BRIEFING SHEET The examiner will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

INITIAL CONDITIONS:

1.

An event occurred 15 minutes ago on Unit 1 which resulted in a trip.

2.

The crew has completed all applicable steps of E-2, Faulted Steam Generator Isolation and FR-Z.1 High Containment Pressure.

3.

The crew transitioned to ECA-2.1, UNCONTROLLED DEPRESSURIZA TION OF ALL STEAM GENERATORS.

4.

Operators have been dispatched in attempt to close MSIVs using EA-1-1, Closing MSIVs Locally.

INITIATING CUES:

1.

The SRO has directed you to perform ECA-2.1, UNCONTROLLED DEPRESSURIZA TION OF ALL STEAM GENERATORS starting at step 1.

2.

Inform the SRO when complete.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPM F

Task:

Task#:

RO/SRO JOB PERFORMANCE MEASURE Respond to High Containment Pressure, Place RHR Spray in Service 3110160601 1503 NRC Sim JPM F Page 2of13 Task Standard:

The examinee will establish one train of RHR spray in service using FR-Z.1, HIGH CONTAINMENT PRESSURE.

Alternate Path:

YES:

x NO:

Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

W/E14 EA1.1 (3.7/3.7)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant ____ Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

8 minutes Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Ensure Simulator Operator Checklist is complete
2. Reset to IC 254
3. If IC 254 is not available reset to IC #24 and complete substeps below.
a. Activate MF# TH01A at 35%.
b. Activate MFs # CH01 A thru D at 70% (-10.2 psid) with 240 sec ramp.
c.

Stop RCPs.

d. Complete the actions of ES-1.3, Sump Swapover.
e. Activate Override ZDIHS7241A CLOSE, to prevent FCV-72-41 from opening.
f.

Activate ZAOPDl30133 f:5

g. Activate ZAOPDIR30133 f:0.5
4. Activate the following, as necessary, to prevent nuisance alarms:
h. AN:OVRN[96] to ON, prevents Turbine Zero Speed alarm
i.

AN:OVRN[304] to ON, prevents Saturation Monitor alarm

5. Insert Remote Function RHR14 ON, places power on FCV-63-1.
6. PLACE SIMULATOR IN RUN
7. An extra operator will be required to acknowledge alarms.
8. ACKNOWLEDGE ALARMS
9. FREEZE SIMULA TOR.
10. Save as a temporary IC, if repeat runs of JPM will be desired.
11. PLACE SIMULATOR IN RUN
12. At JPM step 15, when candidate opens 1-FCV-72-40:
j.

Modify malfunction CH01A f:O r:240 k:1

k.

Modify malfunction CH01 B f:O r:240 k:1 I.

Modify malfunction CH01 B f:O r:240 k: 1

m. Modify malfunction CH01D f:O r:240 k:1 1503 NRC Sim JPM F Page 3 of 13
13. After JPM is complete, delete the temporary IC, if used. Delete the contents of the recycle bin, If a temporary IC has been deleted.

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

1. FR-Z.1, HIGH CONTAINMENT PRESSURE, step 13 (marked up through step 12)

References:

Reference Title

1.

FR-Z.1 High Containment Pressure 1503 NRC Sim JPM F Page 4of13 Rev No.

19

DIRECTIONS TO EXAMINEE:

1503 NRC Sim JPM F Page 5of13 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1. Unit 1 has experienced a reactor trip and Safety Injection in conjunction with a large break LOCA.
2. The crew is monitoring step 13 of FR-Z.1, HIGH CONT Al NMENT PRESSURE.
3. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> has elapsed since the accident.

INITIATING CUES:

1. The SRO directed you to initiate one train of RHR spray per FR-Z.1, HIGH CONTAINMENT PRESSURE starting at step 13.
2. Inform the SRO when a train of RHR spray is established.

STEP 1

Standard:

Cue Comment STEP 2

Standard:

Comment 1503 NRC Sim JPM F Page 6of13 Start Time SAT Obtain a copy of the FR-Z.1, HIGH CONTAINMENT PRESSURE UNSAT Examinee obtains a copy of FR-Z.1, HIGH CONTAINMENT PRESSURE Provide an in-progress copy of FR-Z.1, HIGH CONTAINMENT PRESSURE complete through step 12 13_

~ONl~OR if RHR spray should be placed SAT in service:

a_ CHECK the following:

UNSAT

. Containment pressure greater than 9.5 psig ANIJ Examinee checks 1-PDl-30-45 and 44 and determines that pressure is greater than 9.5

STEP 3

Standard:

Cue Comment STEP 4

Standard:

Cue Comment

13.

MONITOR if RHR spray should be placed in service:

a. CHECK the following:

. At least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> has elapsed since beginning of accident 1503 NRC Sim JPM F Page 7of13 SAT UNSAT Examinee determines from initiating cues (or asks US) that 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> has elapsed IF asked, provide the following cue, "1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> has elapsed since beginning of accident".

13.

MONITOR if RHR spray should be placed SAT in service:

a. CHECK the following:

UNSAT

. RHR suction ALIGNED to containment sump Examinee checks FCV-63-72 and 73 OPEN and FCV-74-3 and 21 CLOSED, or asks if ES-1.3, "Transfer to RHR Containment Sump,"

has been completed.

IF asked, provide the following cue, "ES-1.3 has been completed."

STEP 5

Standard:

Comment STEP 6

Standard:

Comment STEP 7

Standard:

Comment 13_

MONITOR if RHR spray should be placed 1n service:

a_ CHECK the following:

. At least one CCP ANO one SI pump RUNNING_

Examinee verifies at least one CCP is running as indicated by Red light on HS-62-104A or 108A ON.

AND Verifies at least one SI pump is running as indicated by Red lights on HS-63-10A or 15A ON.

13_

MONITOR if RHR spray should be placed in service~

b_

CHECK both RHR pumps RUNNING.

Examinee checks that both RHR pumps are running as indicated by red lights on HS-74-10A and 20A "ON".

13_

c_ ESTABLISH Train B RHR spray:

1) CHECK Train B RHR pump RUNNING_

1503 NRC Sim JPM F Page 8of13 SAT UNSAT SAT UNSAT SAT UNSAT Examinee checks that 1 B-B RHR pump is running as indicated by red light on HS-74-20A "ON".

STEP 8

Standard:

Comment STEP 9

Comment STEP 10 Standard:

Comment

n. c. ESTABLISH Train B RHR spray:
2) ENSURE RHR crosstie FCV-74-35 CLOSED.

1503 NRC Sim JPM F Page 9of13 SAT UNSAT Examinee verifies FCV-74-35 in the CLOSED position as indicated by HS green light ON and red light OFF

c. EST ABUSH Train B RHR spray:
3) CLOSE RHR injection FCV-63-94.

ALTERNATE PATH

13.
c. ESTABLISH Train B RHR spray:
1) CHECK Train B RHR pump RUNNING.
2) ENSURE RHR crosstie FCV-74-35 CLOSED.
3) CLOSE RHR injection FCV-63-94.
4) OPEN RHR spray FCV-72-41.
c.

IF Train B RHR spray CANNOT be established.

THEN PERFORM the following:

a) ENSURE RHR spray FCV-72-41 CLOSED.

b} IF RHR aligned for cold leg recirculation, THEN ENSURE FCV-63-94 OPEN.

Examinee places handswitch for RHR injection FCV-72-41 in OPEN recognizes green light stays ON and red light is OFF and goes to RNO.

SAT UNSAT SAT UNSAT

STEP 11 Standard:

Comment STEP 12 Comment STEP 13 Standard:

Comment AL TERNA TE PATH c_

IF Train B RHR spray CANNOT be established, THEN PERFORM the follov.ring:

a) ENSURE RHR spray FCV-72--41 CLOSED.

Examinee verifies FCV-72-41 closed as indicated by green light ON and red light OFF.

c.

IF Train B RHR spray CANNOT be established, THEN c_

PERFORM the follo11.ring:

b) IF RHR aligned for cold leg recirculation, THEN ENSURE FCV-63-94 OPEN.

IF Train B RHR spray CANNOT be established, THEN PERFORM the following:

c) ESTABLISH Train A RHR spray:

(1) ENSURE RHR crosstie FCV-74-33 CLOSED.

Examinee verifies RHR crosstie FCV-74-33 in the CLOSED position as indicated by green light ON handswitch.

1503 NRC Sim JPM F Page 10of13 SAT UNSAT SAT UNSAT SAT UNSAT

STEP 14 Comment STEP 15 Examiner Note Comment

c. IF Train B RHR spray CANNOT be established, THEN PERFORM the fol!o'liing:

c) ESTABLISH Train A RHR spray:

(2) CLOSE RHR injection FCV-63-93.

c. IF Train B RHR spray CANNOT be established, THEN PERFORM the following:

c) ESTABLISH Train A RHR spray:

(3} OPEN RHR spray FCV-72-40.

1503 NRC Sim JPM F Page 11 of 13 SAT UNSAT SAT UNSAT When examinee starts to open FCV-72-40, initate a 240 sec ramp on CH01 A thru D to reduce CNMT pressure from 10.2 to zero (0).

STEP 16 Standard:

Comment Terminating Cue:

1503 NRC Sim JPM F Page 12of13 Examinee verifies that RHR Containment spray is effective in lowering CNMT pressure.

Examinee verifies that CNMT pressure is lowering by observing Lower pressure readings on CH01A thru D Provide the following cue, "Another operator will complete the remaining steps of this procedure."

Stop Time SAT UNSAT STOP

DIRECTIONS TO EXAMINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1. Unit 1 has experienced a reactor trip and Safety Injection in conjunction with a large break LOCA.
2. The crew is monitoring step 13 of FR-Z.1, HIGH CONTAINMENT PRESSURE.
3. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> has elapsed since the accident.

INITIATING CUES:

1. The SRO directed you to initiate one train of RHR spray per FR-Z.1, HIGH CONTAINMENT PRESSURE starting at step 13.
2. Inform the SRO when a train of RHR spray is established.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPMG

RO/SRO JOB PERFORMANCE MEASURE Task:

3210430301 Task#:

Respond to a loss of Shutdown Board using AOP-P.05.

2015 NRC SIM JPM G Page 2of10 Task Standard:

The examinee will respond to a loss of Shutdown Board using AOP-P.05 and start the 1A Charging pump. Subsequently the examinee will place the 1 B Diesel Generator in emergency stop due to a failure of the cooling water valve to open.

Alternate Path:

YES:

NO:

x Time Critical Task:

YES:

NO:

x K/A Reference/Ratings:

062 A2.04 (3.1/3.4)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

8 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS:

1.

Ensure Simulator Operator Checklist is complete

2.

Reset to IC 16

3.

PLACE SIMULATOR IN RUN

4. An extra operator will be required to acknowledge alarms.
5. ACKNOWLEDGE ALARMS
6. FREEZE SIMULATOR.
7.

Save as a temporary IC, if repeat runs of JPM will be desired.

8.

PLACE SIMULATOR IN RUN

9. De-energize the 1 B 6.9 kv Shutdown Board by inserting IMF EDOGB 2015 NRC SIM JPM G Page 3of10
10. After JPM is complete, delete the temporary IC, if used. Delete the contents of the recycle bin, If a temporary IC has been deleted.

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

References:

Reference Title

1.

AOP-P.05 LOSS OF UNIT 1 SHUTDOWN BOARDS Rev No.

23

DIRECTIONS TO TRAINEE:

2015 NRC SIM JPM G Page 4of10 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 1.

INITIATING CUES:

1.

Respond to plant conditions

2015 NRC SIM JPM G Page 5of10 Start Time STEP 1

SAT Obtain a copy of AOP-P.05 LOSS OF UNIT 1 SHUTDOWN BOARDS.

UNSAT Standard:

Examinee obtains a copy of AOP-P.05 LOSS OF UNIT 1 SHUTDOWN BOARDS.

Comment

2.

DETERMINE applicable section:

GOTO IF...

SECTION PAGE 1A-A 2.1 4

6900V Shutdown Board DE-ENERGIZED 18-B 2.2 20 STEP 2

SAT Determine applicable section.

UNSAT Standard:

The examinee determines the 1 B 6.9 kv Shutdown Board is de-energized and proceeds to section 2.2.

Comment

NOTE STEP 3

Standard:

Comment CAUTION STEP 4

Standard:

Examiner Note Comment 2015 NRC SIM JPM G Page 6of10 MSR HP Steam Supply valves will close due to loss of power, resulting in load reduction.

Loss of power to this board will result in a loss of RPls and rod bottom lights.

SAT

1.

MONITOR 1 A-A 6900V Shutdown Board ENERGIZED.

UNSAT The examinee monitors 1A-A 6900V Shutdown Board ENERGIZED by observing plant instrumentation.

Restoring seal cooling to an overheated RCP seal could result in RCP seal damage or steam voiding in CCS.

Operation of RCPs for greater than 2 minutes without CCS cooling to oil coolers will result in bearing temperatures greater than 200°F.

2.

CHECK RCP seal cooling available:

SAT seal Injection flow UNSAT OR thermal barrier cooling flow The examinee addresses the procedure step.

Thermal barrier cooling water flow is available.

STEP 5

Standard:

Comment STEP 6

Comment STEP 7

Standard:

Comment 2015 NRC SIM JPM G Page 7of10

3.

ENSURE at least one Train B ERCW Pump RUNNING:

M-B ERCW Pump OR P-B ERCW Pump The examinee verifies B Train ERCW running by observing the red light above the respective handswitch ON.

4.

ENSURE the following:

DIGs RUNNING ERCW ALIGNED to running DIGs.

EMERGENCY STOP any running DIG with NO ERCW cooling available.

5.

ENSURE CCS pumps RUNNING:

a.

ENSURE 1A-A CCS Pump supplying Train A.

b.

ENSURE 2B-B or C-S CCS Pump supplying Train B.

The examinee verifies 1A CCS pump running by observing the red light above the HS-70-47A ON.

The examinee verifies C-S CCS pump running by observing the red light above the HS-70-51A ON.

SAT UNSAT SAT UNSAT SAT UNSAT

NOTE STEP 8

Standard:

Comment STEP 9

Standard:

Comment STEP 9

Comment 2015 NRC SIM JPM G Page 8of10 If RHR pump 1 B-B was in service for shutdown cooling prior to loss of 6900V Shutdown Board 1 B-B, the pump will not restart automatically.

6.

IF RHR pump 1 B-B was in service for shutdown cooling, THEN ENSURE AOP-R.03, RHR System Malfunctions, entered to address RHR pump trip, WHILE continuing in this procedure.

The examinee addresses the procedure step as N/A.

7.

MONITOR REACTOR COOLANT PUMPS MOTOR THRUST BEARING TEMP HIGH alarm DARK. [1-M-58, E-3]

The Examinee observes [1-M-5B, E-3] dark.

8.

CHECK CCP 1A-A RUNNING.

PERFORM the following:

a. ENSURE CCP suction path:

LCV-62-132 and -133 OPEN with VCT level greater than 20%

OR LCV-62-135 OPEN

b. START CCP 1A-A.

SAT UNSAT SAT UNSAT SAT UNSAT

2015 NRC SIM JPM G Page 9of10 Terminating Provide the following cue, "Another operator will complete the STOP Cue:

remaining steps of this procedure."

Stop Time ___ _

JPM BRIEFING SHEET The examiner will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 1.

INITIATING CUES:

1.

Respond to plant conditions Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT 1503 NRC SIMULATOR JPM H

RO/SRO JOB PERFORMANCE MEASURE 2015 NRC SIM JPM H Page 2of16 Task:

Respond to a loss of Essential Raw Cooling Water per AOP-M.01.

Task#:

0000620501 Task Standard:

The examinee will respond to a loss of ERCW by starting the STANDBY A TRAIN ERCW Pump and respond to the ERCW leak by stopping B Train ERCW pumps, align an alternate source of ERCW is supplied to the Unit 1 EDG's and start the A Charging pump.

Alternate Path:

YES:

x NO:

Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

APE A07AA1.3 (3.3/3.5)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator x

In-Plant Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

20 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS:

1. Ensure Simulator Operator Checklist is complete
2.

Reset to IC 16

3.

PLACE SIMULATOR IN RUN

4. An extra operator will be required to acknowledge alarms.
5. ACKNOWLEDGE ALARMS
6.

FREEZE SIMULATOR.

7.

Save as a temporary IC, if repeat runs of JPM will be desired.

8.

PLACE SIMULATOR IN RUN 2015 NRC SIM JPM H Page 3 of 16

9. After JPM is complete, delete the temporary IC, if used. Delete the contents of the recycle bin, If a temporary IC has been deleted.
10. When directed insert malfunction MF RW01G (Trips Q-A ERCW Pump)
11. When directed insert malfunction RW138 at 90% prior to JPM step 8.

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

References:

Reference Title Rev No.

1.

AOP-M.01 Loss of ERCW 28

DIRECTIONS TO TRAINEE:

2015 NRC SIM JPM H Page 4 of 16 I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 1.

INITIATING CUES:

1.

Respond to plant conditions

STEP 1

Standard:

Comment 2015 NRC SIM JPM H Page 5of16 Panel M-27A PUMP R-A DISH PRESS LOW Panel M27-BA ERCW/CCS PUMP MOTOR TRIP Start Time Responds to alarm using ARP O-AR-M27-A, B-2 and/or O-AR-M27-BA, E-4

[1] IF ERCW pump motor TRIPS, THEN GO TO AOP-M.01, Loss of Essential Raw Cooling Water_

[2] IF CCS motor trip, THEN GO TO AOP-M.03, Loss of Component Cooling Water.

[3] DETERMINE which motor tripped.

[4] TURN control switch to OFF position to reset alarm.

[5] DISPATCH operator to investigate cause of alarm.

[6] EVALUATE LCO 3.7.3 {CCS) or 3.7.4 (ERCW).

Examinee Places O-HS-67-460A ERCW Pump Q-A in PTL and transitions to AOP-M.01, LOSS OF ESSENTIAL RAW COOLING WATER.

SAT UNSAT

STEP 2

Standard:

Comment STEP 3

Standard:

Comment 2015 NRC SIM JPM H Page 6of16 CAUTION:

ERCW header rupture in Aux Bldg could fill passive sump in 15 minutes..

Prompt action may be needed to isolate rupture using this AOP.

  • L CHECK for indications of ERCW rupture GO TO Step4.

SAT inside Aux Building:

~

flooding from ERCW inside Aux Bldg UNSAT which requires rapid isolation to protect equipment or personnel OR abnom1al high flow indicated on any ERCW supply header in conjunction with flooding alamis or other indications of rupture.

Examinee determines no leak exists in the Aux Building based on no reports of flooding and no indications of high flow and so goes to RNO and then to STEP 4

4.

IF this procedure entered for any reason SAT other than ERCW rupture in Aux Bldg, THEN UNSAT GO TO applicable section:

The examinee determines a pump trip has occurred and goes to section 2.1.

IF...

GO TO SECTION 2015 NRC SIM JPM H Page 7 of 16 PAGE ERCW Pump(s) tripped or failed 2.1 ERCW pump failure g

STEP 4

Standard:

Comment STEP 5

Comment STEP 6

Standard:

Comment

  • T_

IDENTIFY and LOCK OUT failed ERCW pump.

Examinee Places O-HS-67-460A ERCW Pump Q-A in PTL if not already performed.

2.

START additional ERCW pumps

3.

as required to maintain supply header pressure between 78 psig and 124 psig.

CHECK two Train A. ERCW Pumps AVAILABLE.

Examinee verifies that 2 Train A ERCW Pumps are available based on various indications.

SAT UNSAT SAT UNSAT SAT UNSAT

STEP 7

Standard:

Comment Examiner Note:

STEP 8

Standard:

Comment 2015 NRC SIM JPM H Page 8 of 16 4_

CHECK 1A and 2A ERCW supply SAT header pressures and ftows NORMAL:

a_

Supply header pressures UNSAT

{between 1p psig and 124 psig]:

1-Pl-67-493A 2-Pl-67-493A

b.

Supply header ffows

[expected value}:

1-F!-67-61 2-Fl-67-61 Examinee determines that A Train supply header pressures and flows are normal based on plant indicators.

Direct the simulator operator to insert RW13B at 90% prior to JPM step 8.

AL TERNA TE PATH SAT 5_

CHECK 1 B and 2B ERCW supply header IF header leak or rupture is indicated, UNSAT pressures and flows NORMAL:

THEN RETURN TO Section 2.0 ior diagnosis.

a.

Supply header pressures [between

,_-;J//1--

78 psig and 124 psigJ:

  • 1-Pl-67-488A IF NO Train 8 ERCW pump is available,
  • 2-P!-67-4BBA THEN GO TO Section 2.11, Loss ofTmin B ERC'N.
b.

Supply header i!ows [expecte<! value]: ~

  • 1-Fl--07-62
  • 2-Fl-67-62 If pressure is !ow due to only one pump available, THEN EVALUATE isolation of non-essential ERCW loads.

Examinee checks Train B header pressures and flows and determines flows are abnormal based on the listed indicators, goes to the RNO and then to Section 2.0 for diagnosis

2015 NRC SIM JPM H p

9 f 16 age 0

CAUTION:

ERCW header rupture in Aux: Bldg could fill passive sump in 15 minutes.

Prompt action may be needed to isolate rupture using this AOP.

STEP 9

1.

CHECK for indications of ERCW rupture GOTOStep4.

SAT inside Aux Building:

~

flooding from ERCW inside Aux Bldg UNSAT which requrres rapid isolation to protect equipment or personnel OR

  • abnormal high ffow indicated on any ERCW supply header.in conjunction with flooding alarms or other indications of rupture.

Cue If asked provide the following cue," There are no reports of flooding from the Aux Building."

Examinee determines no leak exists in the Aux Building based on no Standard:

reports of flooding and no indications of high flow and so goes to RNO and then to STEP 4 Comment STEP 10

4.

If this procedure entered for any reason SAT other lhan ERCW rupture in Aux Bldg, THEN GO TO applicable section:

UNSAT Low flow ERCW supply headers 18 and 28, AND STRAINER DIFF PRESS alarms DARK

[M-27 A C-6 and D-5],

AND at least one of the following alarms LIT:

[1-M-158, A-3]

Upstream of Strainer Inlet OR Valves OR Loss of Train B ERCW

. ERCW DECK SUMP PMP RUNNING

[1-M-158, D-2 or D-4]

OR

  • MECH EQUIP SUMP LVL HI alarm LIT

[1-M-15A, 8-6]

Examinee determines Section 2.11 is applicable based on Low flow on Standard:

ERCW supply headers 1 B and 28 and one or more of the specified alarms.

Comment

STEP 11 Standard:

Cue:

Comment STEP 12 Comment 2015 NRC SIM JPM H

1.

CHECK this section entered fur any of the following:

rupture known to be upstream of ERCW strainer inlet valve

{1 or 2-FCV-67-489)

OR rupture which CANNOT be isolated OR

  • rupture which requires stopping an Train 6 ERCW flow_

Examinee determines that rupture is known to be upstream the of strainer due to absence of Strainer Differential Pressure alarms in combination with low flow in both 1 B and 28 headers as identified in diagnosis step.

If asked provide the following cue, "The leak is upstream of the B Train strainer."

CAUTION:

If running, Train B CCP and SI Pumps may experience bearing faiture 10 minutes after loss of ERCW cooling.

ALTERNATE PATH

2.

STOP and LOCK OUT all Train 6 ERCW Pumps.

The examinee places O-HS-67-440A ERCW Pump L-B, and O-HS 444A ERCW Pump M-B in PTL. NOT CRITICAL p

10 f 16 aQe 0

SAT UNSAT SAT UNSAT

STEP 13 Standard:

Comment STEP 14 Comment 2015 NRC SIM JPM H Page 11 of 16 CAUTIOH:

Pipe rupture inside ERCW Pumping Station could result in safety hazards due to water spray and flooded compartments.

3_

If periorming this section due to mpillre inside ERCW pumping stafion OR due to rupture in unknown location, THEN DISPATCH operators with radios to perform the following:

  • PERFORM Appendix G -2, ERCW MCC Valves. [ERCW Pumping Station}
  • ENSURE an pumping stalion watertight doors are CLOSED.

IERCW Pumping Station]_

Examinee addresses step and dispatches personnel to perform the required appendix and close watertight doors.

4.

OPEN alternate ERCW supply to Train B DfGs 1-FCV-67-65 (1.B-B DIG) 2-FCV-67-65 (28-8 DIG}

If asked, provide the following cue, "Unit 2 HS-67-65 has been opened."

SAT UNSAT SAT UNSAT

STEP 15 Standard:

Cue Comment STEP 16 Standard:

Comment

5.

DISPATCH operator to place Train B Aux Air Compressor in SAFE STOP.

[Aux Bldg, 734' elev, Refuel floor]

Examinee addresses the procedure step.

Role play and acknowledge the request.

6.

Unit 1 Only:

STOP affected pumps:

a_

CHECK CCP IA-A RUNNING.

a.

2015 NRC SIM JPM H Page 12of16 SAT UNSAT SAT IF RCP thermal barrier cooling is UNSAT in service, THEN

1) ENSURE letdown orifice valves CLOSED.
2) GO TO Substep 6.b.

---=---

Examinee identifies that 1A CCP is not running and goes to RNO.

STEP 17 Comment STEP 18 Comment STEP 19 Standard:

Comment

b.

PLACE CCP 1 B-B in PULL TO LOCK.

c.

PLACE SI pump 1B-:fl in PULL TO LOCK.

2015 NRC SIM JPM H Page 13of16

a.

If RCP thermal barrier cooling is inser:ice, THHl 1} El'JSURE letdown orifice valves CLOSED.

2) GO TO Substep 6.b.

~

SAT UNSAT SAT UNSAT SAT UNSAT Examinee places HS-63-15A SI Pump 1 B in PTL.

7.

Unil20nly:

STEP 20 STOP affected pumps:

a.

CHECK CCP 2A-A RUNNING.

a.

IF RCP thermal bamer cooling is in service, THEN

1) ENSURE letdown orifice valves CLOSED.
2) GO TO Substep 7.b.

~

IF RCP !hernial bamer cooling is NOT in service, THEN PERFORM !he foliowing:

1i WHEN CCP 2A-A 1s running (Step 8),

THEN PLACE CCP 2B-B in PULL TO LOCK.

2) GO TO Substep 7.c.

~

b.

PLACE CCP 28-B in PULL TO LOCK.

C.

PLACE SI pump 2B-B in PULL TO LOCK.

Standard:

Examinee addresses the procedure step.

Cue:

Provide the following cue, "Unit 2 will perform Step 7".

Comment STEP 21 8-ENSURE Train A CCPs RUNNING.

Comment 2015 NRC SIM JPM H Page 14of16 SAT UNSAT SAT UNSAT

2015 NRC SIM JPM H Page 15of16 Terminating Provide the following cue, "Another operator will complete the STOP Cue:

remaining steps of this procedure."

Stop Time ___ _

JPM BRIEFING SHEET The examiner will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

INITIAL CONDITIONS:

1.

Unit 1 is in MODE 1.

INITIATING CUES:

1.

Respond to plant conditions Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT JOB PERFORMANCE MEASURE 1503 NRC PLANT JPM I

RO/SRO JOB PERFORMANCE MEASURE Task:

Locally closing MSIV's by pulling control power fuses.

Task#:

3010030601 1503 NRC PLANT JPM I Page 2 of 10 Task Standard:

The examinee closes MSIV's for SG 2, 3, and 4 by placing its transfer control switch in the Auxiliary Control Room in the AUX position then removes the control power fuses on the associated 125 V Vital Battery Board for SG 1.

Alternate Path:

YES:

NO:

x Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

APE 040AA1.04 (4.3/4.3)

Method of Testing:

Simulated Performance:

x Actual Performance:

Evaluation Method:

Simulator In-Plant x

Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

8 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. SM approval will be required to enter the "Trip Hazard Zone".

1503 NRC PLANT JPM I Page 3 of 10

2. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
3. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

1. EA-1-1 Closing MSIVs Locally

References:

Reference Title Rev No.

1.

EA-1-1 Closing MSIVs Locally 1

========================================================================

READ TO EXAMINEE HAND JPM BRIEFING SHEET TO EXAMINEE AT THIS TIME!

DIRECTIONS TO OPERATOR:

I will explain the initial conditions, and state the task to be performed. All steps shall be simulated for this JPM. WHEN ENTERING A UNIT TRIP HAZARD ZONE ENSURE YOU DO NOT TOUCH ANY SWITCHES WITHIN THAT ZONE. I will provide initiating cues and indicate any steps to be discussed.

When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

1. Unit 2 is in MODE 3
2. Unit 2 has experienced faulted SG's.
3. Attempts to close MSIV's from the main control room (MCR) have failed.
4. All MSIV bypass valves are closed.

INITIATING CUES:

1. The SRO has directed you to attempt to close MSIV's, using EA-1-1.
2. Inform the SRO when complete.

STEP 1

Obtain a copy of EA-1-1, Closing MSIVs Locally.

Standard:

Operator obtains a copy of EA-1-1, Closing MSIVs Locally.

Cue Provide a copy of EA-1-1, Closing MS IVs Locally.

Comment STEP 2

4.1 Section Applicability

1.

SELECT applicable unit:

  • Unit 1 --

Unit2 --

Standard:

The Examinee selects Unit 2 based on the initiating cue.

Comment 1503 NRC PLANT JPM I Page 4of10 Start Time SAT UNSAT SAT UNSAT

STEP 3

2.

SELECT affected valve(s):

SIG AFFECTED VALVE(S)

  1. 1 MSIV 0 MSIV bypass 0
  1. 2 MSIV 0 MSIV bypass D
  1. 3 MSIV 0 MSIV bypass 0
  1. 4 MSIV 0 MSIV bypass 0 Standard:

The examinee selects all MSIV's based on the initiating cue Comment STEP 4

3.

IF any Unit 1 MSIV will NOT close.

THEN GO TO Section 4.2.

~

Standard:

The examinee addresses the procedure step as N/A.

Comment STEP 5

4.

IF any Unit 1 MSIV bypass valve will NOT close.

THEN GO TO Section 4.3.

~

Standard:

The Examinee addresses the step as N/A.

Comment 1503 NRC PLANT JPM I Page 5of10 SAT UNSAT SAT D

UNSAT SAT D

UNSAT

STEP 6

5.

IF any Unit 2 MSIV will NOT close, THEN GO TO Section 4.4.

~

Standard:

The Examinee goes to section 4.4 Comment 4.4 Unit 2 MSIV Isolation STEP 7

1.

PLACE affected MSIV transfer control switch in AUX position:

[Auxiliary Control Room, Panels 2-L-11A and 2-L-11 BJ AUX TRANSFER A

SIG EQUIPMENT SWITCH 1

MSIV Loop 1, Train A, 2-FCV-1-4 2-XS-1-4A MSIV Loop 1. Train B. 2-FCV-1-4 2-XS-1-48 Standard:

The Examinee places 2-XS-1-4A & 2-XS-1-48 and to AUX.

Comment 1503 NRC PLANT JPM I Page 6of10 SAT D

UNSAT SAT UNSAT

~

D D

STEP 8

Comment STEP 9

Standard:

Cue Comment 4.4 Unit 2 MSIV Isolation

1.

PLACE affected MSIV transfer control switch in AUX position:

[Auxiliary Control Room, Panels 2-L-11A and 2-L-118]

AUX TRANSFER SIG EQUIPMENT SWITCH 2

MSIV Loop 2, Train A, 2-FCV-1-11 2-XS-1-11A MSIV Loop 2, Train 8, 2-FCV-1-11 2-XS-1-118 3

MSIV Loop 3, Train A, 2-FCV-1-22 2-XS-1-22A MSIV Loop 3, Train B, 2-FCV-1-22 2-XS-1-228 4

MSIV Loop 4, Train A, 2-FCV-1-29 2-XS-1-29A MSIV Loop 4, Train B, 2-FCV-1-29 2-XS-1-29B

2.

CONSULT UO to determine if affected MSIV closed.

1503 NRC PLANT JPM I Page 7 of 10 SAT UNSAT AUX POSITION

'1 D

D D

D D

D D

SAT UNSAT The Examinee contacts the MCR to determine status of MSIV's.

CRITICAL When asked provide the following cue, "The MSIV for Loop 1 is OPEN The MSIV's for Loop 2, 3 and 4 are CLOSED."

STEP 10 Examiner Note:

Comment 1503 NRC PLANT JPM I Page 8of10 NOTE 1 Fuse pullers and flashlight will be needed for next step.

These may be obtained from AOP-C.04 cabinet in 6.9KV Shutdown Board Room A.

NOTE2 Fuses may be removed in any order.

3.

IF affected MS!V still open SIG 1

OR control power fuse removal desired, THEN REMOVE fuses for affected MSIV(s}:

EQUIPMENT MSIV loop 1, Train A. 2-FCV-1-4 MSIV loop 1, Train B, 2-FCV-1-4 FUSE LOCATION (Two per circuit) 125V Vital Battery Bd Ill Circuit A-46 Circuit 8-46 125V Vital Battery Bd IV Circuit A-46 Circuit B-46 Required fuses are identified by a green "EOI" label.

FUSES REMOVED

\\f D

D D

D If asked provide the following cue, "Loop 1 MSIV is CLOSED. Steam generator #1 pressure is 450 psig and stable."

SAT UNSAT

STEP 11 Standard:

Comment Terminating Cue:

4.

GO TO Section 4.1, step in effect.

1503 NRG PLANT JPM I Page 9of10 SAT UNSAT END OF SECTION The Examinee addresses the procedure step.

The JPM is complete when the Examinee returns the cue sheet to STOP the Examiner.

Stop Time

JPM BRIEFING SHEET DIRECTIONS TO OPERATOR:

All steps shall be simulated for this JPM. WHEN ENTERING A UNIT TRIP HAZARD ZONE ENSURE YOU DO NOT TOUCH ANY SWITCHES WITHIN THAT ZONE. You will be provided initiating cues and indicate any steps to be discussed. When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

1. Unit 2 is in MODE 3
2. Unit 2 has experienced faulted SG's.
3. Attempts to close MSIV's from the main control room (MCR) have failed.
4. All MSIV bypass valves are closed.

INITIATING CUES:

1. The SRO has directed you to attempt to close MSIV's, using EA-1-1.
2. Inform the SRO when complete.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT JOB PERFORMANCE MEASURE 1503 NRC PLANT JPMJ

RO/SRO JOB PERFORMANCE MEASURE PLANT JPM J Page 2 of 8 Task:

Take Local Control of the Turbine Driven AFW Level Control valve 2-LCV-3-175.

Task#:

0000140504 Task Standard:

The Examinee simulates assuming local control of 2-LCV-3-175.

Alternate Path:

YES:

NO:

x Time Critical Task:

YES:

NO:

x KJA Reference/Ratings:

APE 068AA1.03 (4.1/4.3)

Method of Testing:

Simulated Performance:

x Actual Performance:

Evaluation Method:

Simulator In-Plant x

Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

12 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT/UNSAT column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

T ools/Eq uipment/Proced ures Needed:

1. AOP-C.04, SHUTDOWN FROM AUXILIARY CONTROL ROOM Appendix W.2.

References:

Reference Title

1.

AOP-C.04 SHUTDOWN FROM AUXILIARY CONTROL ROOM PLANT JPM J Page 3 of 8 Rev No.

35

========================================================================

READ TO EXAMINEE HAND JPM BRIEFING SHEET TO EXAMINEE AT THIS TIME!

DIRECTIONS TO OPERATOR:

I will explain the initial conditions, and state the task to be performed. All steps shall be simulated for this JPM. I will provide initiating cues and indicate any steps to be discussed. When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

1. Unit 2 is in MODE 3.
2. Unit 2 TD AFW Loop 4 LCV (2-LCV-175) is OPEN.
3. AOP-C.04, SHUTDOWN FROM AUXILIARY CONTROL ROOM is in progress.
4. APPENDIX W.2 CONTROL OF UNIT 2 TURBINE DRIVEN AFW FLOW FROM OUTSIDE MCR has been completed through step 5.

INITIATING CUES:

W.2 CONTROL OF UNIT 2 TURBINE DRIVEN AFW FLOW FROM OUTSIDE MCR-startil'l§ at ste~ ~

4r-

1. You have been directed to locally shut Unit 2 TD AFW Loop 4 LCV (2-LCV-175) using APPENDIX I
2. Inform the SRO when complete.

STEP 1

Obtain a copy of AOP-C.04, SHUTDOWN FROM AUXILIARY CONTROL ROOM.

Standard:

Operator obtains a copy of AOP-C.04, SHUTDOWN FROM AUXILIARY CONTROL ROOM.

Cue Provide a copy of AOP-C.04, SHUTDOWN FROM AUXILIARY CONTROL ROOM Appendix W.2.

Comment STEP 2

6.

IF necessary to locally control TD AFW flow to Unit 2 SIG #1.

THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm at emergency control station for 2-LCV-3-174]

Standard:

The Examinee addresses the procedure step as N/A.

Comment STEP 3

7.

IF necessary to locally control TD AFW flow to Unit 2 SIG #2 or 3.

THEN THROTTLE or CLOSE TD AFW valves as directed:

Standard:

The Examinee addresses the procedure step as N/A.

Comment PLANT JPM J Page 4 of 8 Start Time SAT UNSAT SAT UNSAT SAT UNSAT

NOTE1 NOTE2 STEP 4

Comment STEP 5

Comment PLANT JPM J Page 5 of 8 Turbine-Driven AFW level control valves fail in OPEN position on loss of control air. The following step uses air from SBO air bottle to close SIG #4 TDAFW LCV from emergency control station. Approximately 45 psig (on outlet pressure indicator 2-Pl-3-1758) should be applied if necessary to close valve.

At minimum SBO air bottle pressure {800 psig), sufficient air supply is available for at least four full strokes (open to closed) of TD AFW LCV. Valve strokes should be minimized to conserve air supply.

8.

IF necessary to locally control TD AFW flow to Unit 2 S/G #4, THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm using emergency control station for 2-LCV-3-175]

a. CLOSE [2-VTIV-3-175EJ, Vent Valve.

D Provide the following cue, "Valve handle turned 90° CW and is now snug."

8.

IF necessary to locally control TD AFW flow to Unit 2 S/G #4, THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm using emergency control station for 2-LCV-3-175]

Provide the following cue, "Regulator handle turned several turns CCW and is now snug."

SAT UNSAT SAT UNSAT

STEP 6

Comment STEP 7

Comment

8.

IF necessary to locally control TD AFW flow to Unit 2 S/G #4, THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm using emergency control station for 2-LCV-3-175]

c.

OPEN [2-ISIV-32-1866KJ, SBO/App. R HP Air Cyl !sol Valve.

Provide the following cue, "Valve handle turned 90° CCW and is now snug."

If asked provide the following cue point to 90 psig on pressure indicator 2-Pl-3-1750.

8.

IF necessary to locally control TD AFW flow to Unit 2 S/G #4, THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm using emergency control station for 2-LCV-3-175]

Provide the following cue, "Valve handle turned 90° CCW and is now snug."

D PLANT JPM J Page 6 of 8 SAT UNSAT SAT UNSAT

STEP 8

8.

IF necessary to locally control TD AFW flow to Unit 2 SIG #4, THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm using emergency control station for 2-LCV-3-175]

Cue Provide the following cue, "Valve handle turned 90° CCW."

Comment STEP 9

Comment Terminating Cue:

8.

IF necessary to locally control TD AFW flow to Unit 2 SIG #4, THEN PERFORM the following: [Aux Bldg el 714 Unit 2 Pen Rm using emergency control station for 2-LCV-3-175]

f.

ADJUST [2-PREG-3-1751. Pressure Regulator. slowly in clockwise direction to close 2-LCV-3-175 as directed by ACR.

D If asked as to where to place 2-LCV-3-175, direct the Examinee to refer to the initiating cue.

After the Examinee simulates adjusting [2-PREG-3-175], Pressure Regulator, in full clockwise direction point approximately to 45 psig on outlet pressure indicator 2-Pl-3-1758.

Provide the following cue "Another operator will perform the remaining steps of this procedure."

PLANT JPM J Page 7 of 8 SAT UNSAT SAT UNSAT STOP Stop Time

JPM BRIEFING SHEET DIRECTIONS TO OPERATOR:

All steps shall be simulated for this JPM. You will be provided initiating cues and indicate any steps to be discussed. When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

1. Unit 2 is in MODE 3.
2. Unit 2 TD AFW Loop 4 LCV (2-LCV-175) is OPEN.
3. AOP-C.04, SHUTDOWN FROM AUXILIARY CONTROL ROOM is in progress.
4. APPENDIX W.2 CONTROL OF UNIT 2 TURBINE DRIVEN AFW FLOW FROM OUTSIDE MCR has been completed through step 5.

INITIATING CUES:

W.2 CONTROL OF UNIT 2 TURBINE DRIVEN AFW FLOW FROM OUTSIDE MCR.$:l:nrtio9 at shsf>'" ~

1. You have been directed to locally shut Unit 2 TD AFW Loop 4 LCV (2-LCV-175) using APPENDIX l

-e:-

2. Inform the SRO when complete.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.

SEQUOYAH NUCLEAR PLANT JOB PERFORMANCE MEASURE 1503 NRC PLANT JPM K

RO/SRO JOB PERFORMANCE MEASURE Task:

Radiation Monitor O-RE-90-122 Flushing After Hi Radiation Signal Isolation of Release.

Task#:

0690100104 PLANT JPM K Page 2 of 14 Task Standard:

The examinee completes flushing of O-RE-90-122 after isolation due to high radiation.

Alternate Path:

YES:

NO:

x Time Critical Task:

YES:

NO:

x KIA Reference/Ratings:

073 K4.02 (3.3/3.9)

Method of Testing:

Simulated Performance:

Actual Performance:

x Evaluation Method:

Simulator In-Plant x

Classroom Main Control Room Mock-up Performer:

Trainee Name Evaluator:

I Name I Signature DATE Performance Rating:

SAT:

UNSAT:

Validation Time:

20 min Total Time:

Performance Time:

Start Time:

Finish Time:

COMMENTS

SPECIAL INSTRUCTIONS TO EVALUATOR:

1. Critical steps are identified in step SAT /UNSA T column by bold print 'Critical Step.'
2. Any UNSAT requires comments.

Tools/Equipment/Procedures Needed:

PLANT JPM K Page 3of14

1. In-progress copy of O-S0-77-1, Waste Disposal System, section 8.2 Radiation Monitor O-RE-90-122 Flushing After Hi Radiation Signal Isolation of Release.

References:

Reference Title Rev No.

O-S0-77-1 Waste Dis osal S stem 53

========================================================================

READ TO EXAMINEE DIRECTIONS TO EXAMINEE:

I will explain the initial conditions, and state the task to be performed. All steps shall be simulated for this JPM. I will provide initiating cues and indicate any steps to be discussed. When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

HAND JPM BRIEFING SHEET TO EXAM/NEE AT THIS TIME!

INITIAL CONDITIONS:

1. A release from the CDCT has just been initiated using O-S0-77-1, Waste Disposal System and O-Sl-CEM-077-400.1 Liquid Waste Effluent Batch Release.
2. The calculated high radiation trip setpoint for O-RM-90-122 is 8.59 E+04 cpm, using O-Sl-CEM-077-400.1, Liquid Waste Effluent Batch Release.
3. A high radiation signal on O-RE-90-122 occurred shortly after initiation of the release, causing an isolation of the release.
4. O-RCV-77-43 has been verified CLOSED.
5. All Prerequisite Actions are complete (Section 4.0)

INITIATING CUES:

1. You have been directed to perform Section 8.2 of O-S0-77-1, Waste Disposal System to flush O-RE-90-122 after the High Radiation Isolation.
2. Inform the SRO when complete.

STEP 1

Standard:

Cue Comment STEP 2

Standard:

Cue Comment PLANT JPM K Page 4 of 14 Start Time SAT Obtain a copy of O-S0-77-1, Waste Disposal System UNSAT Operator obtains a copy of O-S0-77-1, Waste Disposal System Provide an in progress copy of O-S0-77-1, Waste Disposal System, section 8.2 Radiation Monitor O-RE-90-122 Flushing After Hi Radiation Signal Isolation of Release.

SAT

[1]

ENSURE [0-RCV-77-431 Radiation Control Valve is CLOSED.

UNSAT The Examinee refers to the procedure step.

If asked, tell the Examinee to refer to the initial conditions.

STEP 3

Standard:

Cue Comment STEP 4

Comment

[2]

ENSURE £0-77-689AJ Radiation Monitor Inlet Isolation Valve is OPEN.

Examinee simulates ensuring [0-77-689A] Radiation Monitor Inlet Isolation Valve is OPEN.

If asked provide the following cue, "valve HW turned in the CW direction slightly and then returned fully CCW valve to original position."

[3}

OPEN [0-77-68981 Discharge to FDCT Isolation Valve.

If asked provide the following cue, "valve HW turned in the CCW direction several turns and is now snug."

PLANT JPM K Page 5 of 14 SAT UNSAT SAT UNSAT

STEP 5

Standard:

Comment STEP 6

Standard:

Cue Comment

[4J CLOSE f0-77-689CJ Radiation Monitor Return to Release Header Isolation Valve.

Examinee simulates closing [0-77-689C] Radiation Monitor Return to Release Header Isolation Valve.

[5]

VERIFY fO-RE-90-122] radiation monitor pump is running.

Examinee simulates ensuring [O-RE-90-122] radiation monitor pump is running.

If asked provide the following cue," Red light above O-HS-90-1228 is ON."

PLANT JPM K Page 6 of 14 SAT UNSAT SAT UNSAT

STEP 7

Standard:

Cue Comment STEP 8

Comment

[6]

ALLOW [0-RE-90-122] Radiation Monitor to flush to FDCT for 5 minutes.

Examinee addresses the procedure step.

Provide the following cue, "Time has been compressed, five minutes has passed."

[7]

OPEN C0*77-689C].

If asked provide the following cue, "valve HW turned in the CCW direction several turns and is now snug."

PLANT JPM K Page 7 of 14 SAT UNSAT SAT UNSAT

STEP 9

Comment STEP 10 Standard:

Cue Comment

[8]

CLOSE [0-77 -6898].

If asked provide the following cue, "valve HW turned in the CW direction several turns and is now snug."

[9}

RECORD O-RE-90-122 reading:

O-RE-90-122 Reading cpm.

Examinee records O-RE-90-122 reading.

Provide the following cue "O-RE-90-122 is reading 9.00 E+04 cpm" PLANT JPM K Page 8 of 14 SAT UNSAT SAT UNSAT

STEP 11 Standard:

Comment STEP 12 Comment

[10]

IF the reading obtained in step 8.2[9] is below the trip setpoint.

THEN The Examinee addresses the procedure step as N/A.

[11]

IF the reading obtained in step 8.2[9] is still above the trip setpoint, THEN PERFORM the following steps to lower the radiation monitor reading:

[11.1 J CLOSE applicable tank isolation valve from release header (NIA tanks not aligned):

Tank Being Released Isolation Valve INITIALS Cask Decon Collector Tank 0-77-679 Monitor Tank 0-77-1306 If asked provide the following cue, "valve HW turned in the CW direction several turns and is now snug."

PLANT JPM K Page 9 of 14 SAT UNSAT SAT UNSAT

STEP 13 Comment STEP 14 Comment

[11.2]

OPEN [0-VLV-59-7351 Demin Flush To Radwaste lsol.

If asked provide the following cue, "valve HW turned in the CCW direction several turns and is now snug."

[11.3]

OPEN [0-77-6898] Discharge to FDCT Isolation Valve.

If asked provide the following cue, "valve HW turned in the CCW direction several turns and is now snug."

PLANT JPM K Page 10 of 14 SAT UNSAT SAT UNSAT

STEP 15 Comment STEP 16 Comment

[11.4]

CLOSE f0-77-689CJ Radiation Monitor Return to Release Header Isolation Valve.

If asked provide the following cue, "valve HW turned in the CW direction several turns and is now snug."

[11.5]

WHEN count rate on ro-RE-90-1221 lowers to its minimum value, THEN

[11.5.1]

OPEN f0-77-689CJ Radiation Monitor Return to Release Header Isolation Valve.

Provide the following cue, "Count rate on O-RE-90-122 has lowered to 8.0 E+02 cpm and is stable."

If asked provide the following cue, "valve HW turned in the CCW direction several turns and is now snug."

PLANT JPM K Page 11 of 14 SAT UNSAT SAT UNSAT

STEP 17 Comment STEP 18 Comment

[11.5]

WHEN count rate on ro-RE-90-122]

lowers to its minimum value, THEN

[11.5.2]

CLOSE [0-77-68981 Discharge to FDCT Isolation Valve.

If asked provide the following cue, "valve HW turned in the CW direction several turns and is now snug."

[11.6]

CLOSE [O-VLV-59-735] Demin Flush To Radwaste lsol.

If asked provide the following cue, "valve HW turned in the CW direction several turns and is now snug."

PLANT JPM K Page 12 of 14 SAT UNSAT SAT UNSAT

STEP 19 Comment STEP 20 Standard:

Comment Terminating Cue:

[i 1.7]

OPEN applicable tank isolation valve previously closed in step 8.2[11.1] (N/A tanks not aligned):

Tank Being Released Isolation Valve INITIALS Cask Decon Collector Tank 0-77-679 Monitor Tank 0-77-1306 If asked provide the following cue, "valve HW turned in the CCW direction several turns and is now snug."

[11.8J IF hi radiation alarm will NOT clear, THEN NOTIFY the appropriate US/SRO that alarm will NOT clear.

The Examinee addresses the procedure step as N/A.

Provide the following cue "Another operator will perform the remaining steps of this procedure."

PLANT JPM K Page 13 of 14 SAT UNSAT SAT UNSAT STOP Stop Time

JPM BRIEFING SHEET DIRECTIONS TO EXAMINEE:

I will explain the initial conditions, and state the task to be performed. All steps shall be simulated for this JPM. I will provide initiating cues and indicate any steps to be discussed. When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

1. A release from the CDCT has just been initiated using O-S0-77-1 Waste Disposal System and O-Sl-CEM-077-400.1 Liquid Waste Effluent Batch Release.
2. The calculated high radiation trip setpoint for O-RM-90-122 is 8.59 E+04 cpm, using O-Sl-CEM-077-400.1, Liquid Waste Effluent Batch Release.
3. A high radiation signal on O-RE-90-122 occurred shortly after initiation of the release, causing an isolation of the release.
4. O-RCV-77-43 has been verified CLOSED.
5. All Prerequisite Actions are complete (Section 4.0)

INITIATING CUES:

3. You have been directed to perform Section 8.2 of O-S0-77-1, Waste Disposal System to flush O-RE-90-122 after the High Radiation Isolation.
4. Inform the SRO when complete.

Acknowledge to the examiner when you are ready to begin.

HAND THIS PAPER BACK TO YOUR EVALUATOR WHEN YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK.