ML16042A471: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
| number = ML16042A471 | | number = ML16042A471 | ||
| issue date = 02/18/2016 | | issue date = 02/18/2016 | ||
| title = | | title = Request for Additional Information | ||
| author name = Williams S | | author name = Williams S | ||
| author affiliation = NRC/NRR/DORL/LPLII-1 | | author affiliation = NRC/NRR/DORL/LPLII-1 | ||
| addressee name = Lippard G | | addressee name = Lippard G | ||
| addressee affiliation = South Carolina Electric & Gas Co | | addressee affiliation = South Carolina Electric & Gas Co | ||
| docket = 05000395 | | docket = 05000395 | ||
| license number = NPF-012 | | license number = NPF-012 | ||
| contact person = Williams S | | contact person = Williams S, NRR/DORL/LPLII-1 | ||
| case reference number = CAC MF7085 | | case reference number = CAC MF7085 | ||
| document type = Letter, Request for Additional Information (RAI) | | document type = Letter, Request for Additional Information (RAI) | ||
Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 18, 2016 Mr. George A. Lippard, Ill Vice President, Nuclear Operations South Carolina Electric | {{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 18, 2016 Mr. George A. Lippard, Ill Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065 | ||
& Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065 | |||
==SUBJECT:== | ==SUBJECT:== | ||
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 -REQUEST FOR ADDITIONAL INFORMATION (CAC NO. MF7085) | |||
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 -REQUEST FOR ADDITIONAL INFORMATION (CAC NO. MF7085) | |||
==Dear Mr. Lippard:== | ==Dear Mr. Lippard:== | ||
By letter dated January 20, 2015, the South Carolina Electric | By letter dated January 20, 2015, the South Carolina Electric & Gas Company (SCE&G, the licensee) submitted a relief request for Virgil C. Summer, Unit 1, for the third ten-year inservice inspection interval. The licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. | ||
& Gas Company (SCE&G, the licensee) submitted a relief request for Virgil C. Summer, Unit 1, for the third ten-year inservice inspection interval. | The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell. | ||
The licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell. The NRC staff has determined that additional information is needed to continue the review as discussed in the Enclosure. | The NRC staff has determined that additional information is needed to continue the review as discussed in the Enclosure. We request that SCE&G respond to these RAls within 30 days of the date of this letter. Please note that the NRC staff's review is continuing and further requests for information may be developed. | ||
We request that SCE&G respond to these RAls within 30 days of the date of this letter. Please note that the NRC staff's review is continuing and further requests for information may be developed. | Sincerely, Shawn Williams, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-395 | ||
Docket No. 50-395 | |||
==Enclosure:== | ==Enclosure:== | ||
Request for Additional Information cc w/encl: Distribution via Listserv | Request for Additional Information cc w/encl: Distribution via Listserv | ||
& GAS COMPANY DOCKET NUMBER 50-395 By letter dated November 10, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. | |||
South Carolina Electric | REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST NUMBER RR-111-12 VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 SOUTH CAROLINA ELECTRIC & GAS COMPANY DOCKET NUMBER 50-395 By letter dated November 10, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15316A556), South Carolina Electric & Gas Company, the licensee, submitted relief request number RR-111-12 to the U.S. Nuclear Regulatory Commission (NRC) for the third ten-year inservice inspection interval of Virgil C. Summer Nuclear Station, Unit 1. In relief request RR-111-12, the licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell identified in the licensee's submittal. These two welds are ASME Code, Section XI, Examination Category C-A welds, Item Nos. C1 .20. The licensee has determined that conformance with the examination requirements Section XI of the ASME Code for these welds is impractical. Title 1O of the Code of Federal Regulations (1 O CFR), Part 50, Paragraph 50.55a(g)(5)(iii) requires the licensee to submit information to the NRC to support the determination of impracticality. | ||
& Gas Company, the licensee, submitted relief request number RR-111-12 to the U.S. Nuclear Regulatory Commission (NRC) for the third ten-year inservice inspection interval of Virgil C. Summer Nuclear Station, Unit 1. In relief request RR-111-12, the licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110- | The NRC staff has determined that the following request for additional information (RAI) is required to complete its review. | ||
These two welds are ASME Code, Section XI, Examination Category C-A welds, Item Nos. C1 .20. The licensee has determined that conformance with the examination requirements Section XI of the ASME Code for these welds is impractical. | RAI No. 1 Please discuss the ASME Code Section XI, Appendix I requirement from which procedure SCANA-UT-98-13 is based. If supplements apply, please discuss which supplements were used. | ||
Title | RAI No. 2 Please discuss any plant-specific operating experience regarding potential degradation in welds CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, such as stress corrosion cracking, fatigue cracking, and general corrosion. | ||
The NRC staff has determined that the following request for additional information (RAI) is required to complete its review. RAI No. 1 Please discuss the ASME Code Section XI, Appendix I requirement from which procedure SCANA-UT-98-13 is based. If supplements apply, please discuss which supplements were used. RAI No. 2 Please discuss any plant-specific operating experience regarding potential degradation in welds CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, such as stress corrosion | Enclosure | ||
Enclosure February 18, 2016 Mr. George A Lippard, Ill Vice President, Nuclear Operations South Carolina Electric | February 18, 2016 Mr. George A Lippard, Ill Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065 | ||
& Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065 | |||
==SUBJECT:== | ==SUBJECT:== | ||
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 - REQUEST FOR ADDITIONAL INFORMATION (CAC NO. MF7085) | |||
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 -REQUEST FOR ADDITIONAL INFORMATION (CAC NO. MF7085) | |||
==Dear Mr. Lippard:== | ==Dear Mr. Lippard:== | ||
By letter dated January 20, 2015, the South Carolina Electric | By letter dated January 20, 2015, the South Carolina Electric & Gas Company (SCE&G, the licensee) submitted a relief request for Virgil C. Summer, Unit 1, for the third ten-year inservice inspection interval. The licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. | ||
& Gas Company (SCE&G, the licensee) submitted a relief request for Virgil C. Summer, Unit 1, for the third ten-year inservice inspection interval. | The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell. | ||
The licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell. The NRC staff has determined that additional information is needed to continue the review as discussed in the Enclosure. | The NRC staff has determined that additional information is needed to continue the review as discussed in the Enclosure. We request that SCE&G respond to these RAls within 30 days of the date of this letter. Please note that the NRC staff's review is continuing and further requests for information may be developed. | ||
We request that SCE&G respond to these RAls within 30 days of the date of this letter. Please note that the NRC staff's review is continuing and further requests for information may be developed. | Sincerely, IRA/ | ||
Docket No. 50-395 | Shawn Williams, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-395 | ||
==Enclosure:== | ==Enclosure:== | ||
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION: | |||
PUBLIC | PUBLIC LPL2-1 R/F RidsAcrs_MailCTR Resource RidsNrrDorlDpr Resource RidsNrrDorllpl2-1 Resource RidsRgn2MailCenter Resource RidsNrrLASFigueroa Resource RidsNrrDRA Resource RidsNrrPMSummer Resource DDijamco, NRR ADAMS A ccess1on N o.: ML16042A471 | ||
* b1yema1*1 OFFICE LPL2-1/PM LPL2-1/LA NRR/DE/EVIB/BC* LPL2-1/BC LPL2-1/PM NAME SWilliams SFigueroa JMcHale* MMarkley SWilliams DATE 2/18/2016 2/17/2016 2/10/2016 2/18/2016 2/18/2016 OFFICIAL RECORD COPY}} | |||
* | |||
NAME SWilliams SFigueroa JMcHale* | |||
DATE 2/18/2016 2/17/2016 2/10/2016 |
Latest revision as of 23:38, 30 October 2019
ML16042A471 | |
Person / Time | |
---|---|
Site: | Summer |
Issue date: | 02/18/2016 |
From: | Shawn Williams Plant Licensing Branch II |
To: | Lippard G South Carolina Electric & Gas Co |
Williams S, NRR/DORL/LPLII-1 | |
References | |
CAC MF7085 | |
Download: ML16042A471 (3) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 18, 2016 Mr. George A. Lippard, Ill Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065
SUBJECT:
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 -REQUEST FOR ADDITIONAL INFORMATION (CAC NO. MF7085)
Dear Mr. Lippard:
By letter dated January 20, 2015, the South Carolina Electric & Gas Company (SCE&G, the licensee) submitted a relief request for Virgil C. Summer, Unit 1, for the third ten-year inservice inspection interval. The licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds.
The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell.
The NRC staff has determined that additional information is needed to continue the review as discussed in the Enclosure. We request that SCE&G respond to these RAls within 30 days of the date of this letter. Please note that the NRC staff's review is continuing and further requests for information may be developed.
Sincerely, Shawn Williams, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-395
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST NUMBER RR-111-12 VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 SOUTH CAROLINA ELECTRIC & GAS COMPANY DOCKET NUMBER 50-395 By letter dated November 10, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15316A556), South Carolina Electric & Gas Company, the licensee, submitted relief request number RR-111-12 to the U.S. Nuclear Regulatory Commission (NRC) for the third ten-year inservice inspection interval of Virgil C. Summer Nuclear Station, Unit 1. In relief request RR-111-12, the licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds. The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell identified in the licensee's submittal. These two welds are ASME Code,Section XI, Examination Category C-A welds, Item Nos. C1 .20. The licensee has determined that conformance with the examination requirementsSection XI of the ASME Code for these welds is impractical. Title 1O of the Code of Federal Regulations (1 O CFR), Part 50, Paragraph 50.55a(g)(5)(iii) requires the licensee to submit information to the NRC to support the determination of impracticality.
The NRC staff has determined that the following request for additional information (RAI) is required to complete its review.
RAI No. 1 Please discuss the ASME Code Section XI, Appendix I requirement from which procedure SCANA-UT-98-13 is based. If supplements apply, please discuss which supplements were used.
RAI No. 2 Please discuss any plant-specific operating experience regarding potential degradation in welds CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, such as stress corrosion cracking, fatigue cracking, and general corrosion.
Enclosure
February 18, 2016 Mr. George A Lippard, Ill Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065
SUBJECT:
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 - REQUEST FOR ADDITIONAL INFORMATION (CAC NO. MF7085)
Dear Mr. Lippard:
By letter dated January 20, 2015, the South Carolina Electric & Gas Company (SCE&G, the licensee) submitted a relief request for Virgil C. Summer, Unit 1, for the third ten-year inservice inspection interval. The licensee requested relief from the examination requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) applicable to ASME Code Class 1 piping welds and ASME Code Class 2 vessel welds.
The scope of this letter is for the two ASME Code Class 2 vessel welds, CGE-2-1110-1 B/1 and CGE-2-1110-1 B/2, in the residual heat removal heat exchanger shell.
The NRC staff has determined that additional information is needed to continue the review as discussed in the Enclosure. We request that SCE&G respond to these RAls within 30 days of the date of this letter. Please note that the NRC staff's review is continuing and further requests for information may be developed.
Sincerely, IRA/
Shawn Williams, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-395
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL2-1 R/F RidsAcrs_MailCTR Resource RidsNrrDorlDpr Resource RidsNrrDorllpl2-1 Resource RidsRgn2MailCenter Resource RidsNrrLASFigueroa Resource RidsNrrDRA Resource RidsNrrPMSummer Resource DDijamco, NRR ADAMS A ccess1on N o.: ML16042A471
- b1yema1*1 OFFICE LPL2-1/PM LPL2-1/LA NRR/DE/EVIB/BC* LPL2-1/BC LPL2-1/PM NAME SWilliams SFigueroa JMcHale* MMarkley SWilliams DATE 2/18/2016 2/17/2016 2/10/2016 2/18/2016 2/18/2016 OFFICIAL RECORD COPY