Letter Sequence RAI |
|---|
|
|
MONTHYEARML12361A0062012-11-26026 November 2012 (Mns), Units 1 and 2, Flooding Walkdown Information Requested by NRC Letter, Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54 (F) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Project stage: Request ML13190A2722013-06-20020 June 2013 Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Re Seismic Aspects of Recommendation 2.3 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident Project stage: Response to RAI ML13192A1552013-07-0101 July 2013 Update to Seismic Walkdown Information Submitted in November 27, 2012 Project stage: Request ML14083A5862014-03-12012 March 2014 EPRI to NEI - Fleet Seismic Core Damage Frequency Estimates for Central and Eastern United States Power Plants Using New Site-Specific Seismic Hazard Estimates: Attachment 1 Project stage: Request RNP-RA/14-0012, Flood Hazard Reevaluation Report, Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3 and 9.3..2014-03-12012 March 2014 Flood Hazard Reevaluation Report, Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3 and 9.3.. Project stage: Request MNS-14-029, Seismic Hazard and Screening Report (CEUS Sites), Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3 and 9.3 of the2014-03-20020 March 2014 Seismic Hazard and Screening Report (CEUS Sites), Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3 and 9.3 of the Project stage: Request ONS-2014-046, Seismic Hazard and Screening Report (CEUS Sites), Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.32014-03-31031 March 2014 Seismic Hazard and Screening Report (CEUS Sites), Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3 Project stage: Request CNS-14-045, Commitment Change Evaluation Report for 20132014-03-31031 March 2014 Commitment Change Evaluation Report for 2013 Project stage: Request ML14093A0522014-03-31031 March 2014 Seismic Hazard and Screening Report (CEUS Sites), Response to NRC 10 CFR 50.54(f) RAI Per 10 CFR 50.54(f) Re Recommendations 2.1, 2.3 and 9.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident Project stage: Other ONS-2014-074, Special Report Per Selected Licensee Commitment 16.9.9 Auxiliary Service Water (Asw) System and Main Steam Atmospheric Dump Valves and Oconee Transition from the Station Asw System to the Protected Service Water System2014-08-15015 August 2014 Special Report Per Selected Licensee Commitment 16.9.9 Auxiliary Service Water (Asw) System and Main Steam Atmospheric Dump Valves and Oconee Transition from the Station Asw System to the Protected Service Water System Project stage: Request RC-14-0141, Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-08-28028 August 2014 Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation Project stage: Other ML14255A0052014-08-28028 August 2014 3 - Request for Exemption from Certain Requirements of 10 CFR 72.212(a)(2), 72.212(b)(5), 72.212(b)(11) and 72.214 Project stage: Request ML14268A5162014-10-23023 October 2014 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Re-evaluation Related to Southeastern Catalog Changes Project stage: RAI ONS-2014-144, Special Report Per Selected Licensee Commitment 16.9.9 Auxiliary Service Water (Asw) System and Main Steam Atmospheric Dump Valves and Oconee Transition from the Station Asw System to the Protected Service Water System - Revision 22014-11-12012 November 2014 Special Report Per Selected Licensee Commitment 16.9.9 Auxiliary Service Water (Asw) System and Main Steam Atmospheric Dump Valves and Oconee Transition from the Station Asw System to the Protected Service Water System - Revision 2 Project stage: Request RNP-RA/14-0118, Response to Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Re-Evaluations Related to Southeastern Catalog Changes2014-11-12012 November 2014 Response to Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Re-Evaluations Related to Southeastern Catalog Changes Project stage: Response to RAI RC-14-0182, South Carolina Electric & Gas Response to NRC Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Re-Evaluations2014-11-12012 November 2014 South Carolina Electric & Gas Response to NRC Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Re-Evaluations Project stage: Response to RAI ONS-2014-147, Response to the NRCs Request for Additional Information Dated October 23, 2014, Related to Southeastern Catalog Changes and Seismic Re-Evaluations2014-11-14014 November 2014 Response to the NRCs Request for Additional Information Dated October 23, 2014, Related to Southeastern Catalog Changes and Seismic Re-Evaluations Project stage: Request ML14303A1922014-11-25025 November 2014 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Hazard and Screening Report Project stage: RAI MNS-14-097, Expedited Seismic Evaluation Process Report (CEUS Sites), Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1 of the Near-Term Task Force Review2014-12-17017 December 2014 Expedited Seismic Evaluation Process Report (CEUS Sites), Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1 of the Near-Term Task Force Review Project stage: Response to RAI ONS-2014-161, Submittal of the Expedited Seismic Evaluation Process Report (CEUS Sites)2014-12-19019 December 2014 Submittal of the Expedited Seismic Evaluation Process Report (CEUS Sites) Project stage: Request CNS-14-130, Expedited Seismic Evaluation Process Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident2014-12-31031 December 2014 Expedited Seismic Evaluation Process Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident Project stage: Response to RAI CNS-14-132, Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Hazard and Screening Report2015-01-0808 January 2015 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Hazard and Screening Report Project stage: Request ML15096A5132015-04-27027 April 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f), Seismic Hazard Revaluations Relating to Recommendation 2.1 of the NTTF Review Project stage: Other RNP-RA/15-0039, Submittal of 2014 Annual Radioactive Effluent Releae Report2015-04-28028 April 2015 Submittal of 2014 Annual Radioactive Effluent Releae Report Project stage: Request RC-15-0071, Response to NRC Request for Additional Information Regarding Seismic Evaluation Related to Southeastern Catalog Changes2015-04-28028 April 2015 Response to NRC Request for Additional Information Regarding Seismic Evaluation Related to Southeastern Catalog Changes Project stage: Response to RAI RNP-RA/15-0031, Response to NRC Request for Additional Information Regarding Seismic Re-Evaluations Related to Southeastern Catalog Changes2015-04-29029 April 2015 Response to NRC Request for Additional Information Regarding Seismic Re-Evaluations Related to Southeastern Catalog Changes Project stage: Response to RAI ONS-2015-055, Second Response to Request for Additional Information Dated October 23, 2014, Related to Southeastern Catalog Changes and Seismic Re-Evaluations2015-04-30030 April 2015 Second Response to Request for Additional Information Dated October 23, 2014, Related to Southeastern Catalog Changes and Seismic Re-Evaluations Project stage: Response to RAI ML15182A0672015-07-20020 July 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(F), Seismic Hazard Reevaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from Project stage: Approval ML15194A0552015-07-20020 July 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f), Seismic Hazard Reevaluations Relating to Recommendation 2.1 Fukushima Dai-Ichi Project stage: Other ML15201A0082015-07-22022 July 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f), Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force Review Project stage: Other ML15226A1852015-09-0808 September 2015 Nuclear Regulatory Commission Plan for the Audit of Duke Energy Carolinas, LLC Interim Evaluations Associated with Reevaluated Seismic Hazard Implementing Near-Term Task Force Recommendation 2.1 - Seismic Project stage: Other ML15280A1992015-10-19019 October 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50 Section 50.54(f) Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force Review Project stage: Other ML16034A3252015-12-31031 December 2015 To Summary of Methodology Used for Seismic Capacity Evaluation of GMRS Mitigation Components Project stage: Other ONS-2016-007, Supplemental Information Related to the Expedited Seismic Evaluation Process (ESEP) Report in Response to the NRC Audit Described in Letter Dated September 2, 20152016-01-27027 January 2016 Supplemental Information Related to the Expedited Seismic Evaluation Process (ESEP) Report in Response to the NRC Audit Described in Letter Dated September 2, 2015 Project stage: Supplement 2014-03-31
[Table View] |
Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Re-evaluation Related to Southeastern Catalog Changes| ML14268A516 |
| Person / Time |
|---|
| Site: |
Oconee, Summer, Robinson  (DPR-023, DPR-038, DPR-047, DPR-055, NPF-012) |
|---|
| Issue date: |
10/23/2014 |
|---|
| From: |
Nicholas Difrancesco Japan Lessons-Learned Division |
|---|
| To: |
Batson S, Gatlin T, William Gideon Duke Energy Carolinas, Duke Energy Progress, South Carolina Electric & Gas Co |
|---|
| DiFrancesco N, NRR/JLD, 415-1115 |
| References |
|---|
| TAC MF3724, TAC MF3736, TAC MF3737, TAC MF3738, TAC MF3831 |
| Download: ML14268A516 (6) |
|
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 October 23, 2014 To the Power Reactor Licensees on the Enclosed List
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION ASSOCIATED WITH NEAR-TERM TASK FORCE RECOMMENDATION 2.1, SEISMIC RE-EVALUATIONS RELATED TO SOUTHEASTERN CATALOG CHANGES (TAC NOS. MF3724, MF3736, MF3737, MF3738, AND MF3831)
By letters dated March 31, 2014, and by letter dated March 26, 2014, to the U. S. Nuclear Regulatory Commission (NRC), Duke Energy Progress, Inc. and Duke Energy Carolinas, LLC, the licensees for H.B. Robinson Steam Electric Plant1, Unit No. 2 (Robinson) and Oconee Nuclear Station2, Units 1, 2, and 3 (Oconee); and South Carolina Electric and Gas Company, the licensee for Virgil C. Summer Nuclear Station3, Unit 1 (VC Summer), submitted for NRC review the Seismic Hazard and Screening Report, Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f), Response for Information Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident.
Included in the seismic hazard reevaluation reports are changes to the Central and Eastern United States - Seismic Source Characterization earthquake catalog endorsed by the NRC staff.
The NRC staff has reviewed the information provided for Robinson, Oconee, and VC Summer, and has determined that additional information is required to complete its review. Enclosed is a request for additional information (RAI) related to the earthquake catalog changes in the southeastern region. As discussed with your staff on October 9, 2014, it was agreed that a response to the RAI would be provided no later than November 14, 2014.
1 The Robinson Seismic Hazard Evaluation Report dated March 31, 2014, can be found under Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML14099A204.
2 The Oconee Seismic Hazard Evaluation Report dated March 31, 2014, can be found under ADAMS Accession No. ML14092A024.
3 The VC Summer Seismic Hazard Evaluation Report dated March 26, 2014, can be found under ADAMS Accession No. ML14092A250.
If you have any questions related to the enclosed RAis or the requested submission date, please contact me at 301-415-1115 or via e-mail at Nicholas. Difrancesco@nrc.gov.
Enclosures:
- 1. Request for Additional Information
- 2. Addressee List cc w/encls: Distribution via Listserv Sincerely, Nicholas J. DiFrancesco, Senior Project Manager Hazards Management Branch Japan Lessons-Learned Division Office of Nuclear Reactor Regulation
REQUEST FOR ADDITIONAL INFORMATION NEAR-TERM TASK FORCE RECOMMENDATION 2.1 SEISMIC HAZARD AND SCREENING REPORT FACILITIES PER ENCLOSURE 2 Review of Deviation from CEUS Seismic Source Characterization Catalog Version 7.0 By letter dated March 12, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12053A340), the NRC staff requested that licensees whose plants are located in the central and eastern United States (CEUS) use the recently published Central and Eastern United States Seismic Source Characterization for Nuclear Facilities (CEUS-SSC) to conduct the seismic hazard reevaluations. Specifically, Attachment 1 to "Seismic" Enclosure 1 of the March 12, 2012, letter stated that "regional and local refinements of the CEUS-SSC are not necessary for this evaluation." The staff's endorsement of the CEUS-SSC without refinement was intended to expedite the Near-Term Task Force (NTTF) 2.1 seismic hazard reevaluations and to ensure efficient use of NRC and licensee resources.
By letter dated February 15, 2013 (ADAMS Accession No. ML12319A074), "Endorsement of Electric Power Research Institute [EPRI] Final Draft Report 1025287, 'Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID),' the NRC staff endorsed using the SPID guidance.
Regarding the use of the CEUS-SSC for the NTTF Recommendation 2.1 seismic hazard reevaluations, Section 2 of the SPID states:
For site-specific licensing applications or site-specific safety decisions, these seismic sources would be reviewed on a site-specific basis to determine if they need to be updated. Such evaluations would be appropriate in a licensing application, where focus could be made on site-specific applications. However, for a screening-level study of multiple plants for the purpose of setting priorities, the use of these seismic sources as published is appropriate.
The CEUS-SSC was published as NUREG-2115, DOE/NE-0140, EPRI 1021097, "Central and Eastern United States Seismic Source Characterization for Nuclear Facilities," January 2012 (ADAMS Accession No. ML12048A776) and conducted using a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 study, consistent with NUREG/CR-6372, "Recommendations for Probabilistic Seismic Hazard Analysis: Guidance on Uncertainty and Use of Experts," April1997 (ADAMS Accession Nos. ML080090003 and ML080090004, respectively). The CEUS-SSC expert panel review considered the present state of knowledge of the Charleston seismic zone and known nontectonic events including reservoir-induced events in developing the seismic catalog for the CEUS-SSC. Section 6 of NUREG-2117, "Practical Implementation Guidelines for SSHAC Level 3 and 4 Hazard Studies: Rev. 1," Office of Nuclear Regulatory Research, 2012, (ADAMS Accession No. ML12118A445) recommends that viable regional probabilistic hazard studies, such as the CEUS-SSC, should be updated with at least a SSHAC Level 2 study.
By letters dated March 31, 2014, and by letter dated March 26, 2014, to the NRC, Duke Energy Progress, Inc. and Duke Energy Carolinas, LLC, the licensees for H. B. Robinson Steam Electric Plant, Unit No. 2 (Robinson) and Oconee Nuclear Station, Units 1, 2, and 3 (Oconee); and South Carolina Electric and Gas Company, the licensee for Virgil C. Summer Nuclear Station, Unit 1 (VC Summer), submitted a revision to the CEUS-SSC catalog as part of the reevaluated seismic hazard submittal. Subsequently, by letter dated August 28, 2014 (ADAMS Accession No. ML14260A200),
EPRI provided a report containing CEUS-SSC Catalog Version 8.0 following, "Review of NUREG-2115 Earthquake catalog with regard to identification of additional Reservoir Induced Seismicity (RIS) earthquakes in the southeastern United States and locations of earthquakes in South Carolina near the time of the 1886 Charleston, SC earthquake sequence," dated March 5, 2014.
Note the staff does not consider the proposed catalog update to be a new version of the CEUS-SSC Catalog but rather a regional update specifically made for the Recommendation 2.1 seismic hazard reevaluations of H. B. Robinson, Oconee, and VC Summer plant sites.
Request for Additional Information Consistent with the request for information issued pursuant to Title 10 of the Code of Federal regulations, Part 50, Section 50.54(f) and the SPID guidance, please provide a revised March 2014 seismic hazard reevaluation submittal reflecting the staff endorsed CEUS-SSC Catalog Version 7.0. Alternatively, to ensure that the regional catalog update made for the Recommendation 2.1 seismic hazard reevaluations of H. B. Robinson, Oconee, and VC Summer plant sites represents the center, body, and range of the technically defensible interpretations, please provide a SSHAC Level 2 study. In addition to providing a detailed description of the catalog update, please describe the scope of the update and whether you also considered the impact of earthquakes in the region since the time period covered by the CEUS-SSC Catalog.
Please include in the response, in table form, control point seismic hazard curves developed using both the currently-endorsed CEUS-SSC catalog as well as the proposed updated regional catalog used for the Recommendation 2.1 seismic hazard reevaluations of H.B. Robinson, Oconee, and VC Summer plant sites.
H. B. Robinson Steam Electric Plant Duke Energy Progress, Inc.
Docket No. 50-261 License No. DPR-23 Mr. William R. Gideon, Vice President H.B. Robinson Steam Electric Plant 3581 West Entrance Road Hartsville, SC 29550 Oconee Nuclear Station Duke Energy Carolinas, LLC List of Addressees Docket Nos. 50-269, 50-270 and 50-287 License Nos. DPR-38, DPR-47 and DPR-55 Mr. Scott Batson Vice President, Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672-0752 Virgil C. Summer Nuclear Station South Carolina Electric and Gas Company Docket No. 50-395 License No. NPF-12 Mr. Thomas D. Gatlin, Vice President Nuclear Operations South Carolina Electric and Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065
Nicholas J. DiFrancesco, Senior Project Manager Hazards Management Branch Japan Lessons-Learned Division Office of Nuclear Reactor Regulation RidsNrrDorllpl2-2 NDiFrancesco, NRR RidsNrrPMRobinson RidsRgn2MaiiCenter RidsNrrOd