ML16026A587: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
(8 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
| number = ML16026A587 | | number = ML16026A587 | ||
| issue date = 12/09/2015 | | issue date = 12/09/2015 | ||
| title = | | title = NRR E-mail Capture - South Texas Project Unit 1 Draft Request for Additional Information | ||
| author name = Regner L | | author name = Regner L | ||
| author affiliation = NRC/NRR/DORL/LPLIV-1 | | author affiliation = NRC/NRR/DORL/LPLIV-1 | ||
| addressee name = Richards D | | addressee name = Richards D | ||
Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter: | {{#Wiki_filter:NRR-PMDAPEm Resource From: Regner, Lisa Sent: Wednesday, December 09, 2015 9:47 AM To: Richards, Drew (amrichards@STPEGS.COM); Brost, Wendy (webrost@STPEGS.COM) | ||
Cc: Michael Murray; Sterling, Lance (lsterling@STPEGS.COM); cralbury@stpegs.com | |||
==Subject:== | ==Subject:== | ||
Additional STP RAI for Emergency CR | Additional STP RAI for Emergency CR Amendment | ||
: 7. On page 19 of 22 of your December 3, 2015, emergency amendment request, you state that 10 CFR 50.62(c)(3) concerning an alternate rod injection system as stated in Standard Review Plan, Section 4.6 are for boiling water reactors and do not apply to the South Texas Project Unit 1. The staff agrees that the BWR portion of the Anticipated Transient Without Scram (ATWS) rule, 10 CFR 50.62(c)(3), does not apply; however, the remainder of the ATWS rule, 10 CFR 50.62, should be considered by STP since it does apply to pressurized water reactors. Provide the impact on ATWS for STP considering the removal of control rod D6 | : Drew, As discussed, here is one additional questions to be answered on the docket so that the staff can complete its review of your emergency request for an amendment date December 3, 2015. | ||
: 7. On page 19 of 22 of your December 3, 2015, emergency amendment request, you state that 10 CFR 50.62(c)(3) concerning an alternate rod injection system as stated in Standard Review Plan, Section 4.6 are for boiling water reactors and do not apply to the South Texas Project Unit 1. The staff agrees that the BWR portion of the Anticipated Transient Without Scram (ATWS) rule, 10 CFR 50.62(c)(3), does not apply; however, the remainder of the ATWS rule, 10 CFR 50.62, should be considered by STP since it does apply to pressurized water reactors. Provide the impact on ATWS for STP considering the removal of control rod D6 | |||
: Thanks, Lisa Lisa Regner Sr. PM NRR/DORL/LPL4-1 301-415-1906 O8D08 1 | |||
Hearing Identifier: NRR_PMDA Email Number: 2620 Mail Envelope Properties (8aa2982b0d2b4caca27aa1404d28016e) | |||
==Subject:== | ==Subject:== | ||
Additional STP RAI for Emergency CR Amendment | Additional STP RAI for Emergency CR Amendment Sent Date: 12/9/2015 9:47:13 AM Received Date: 12/9/2015 9:47:00 AM From: Regner, Lisa Created By: Lisa.Regner@nrc.gov Recipients: | ||
Tracking Status: None | "Michael Murray" <mpmurray@STpegs.com> | ||
Tracking Status: None | Tracking Status: None "Sterling, Lance (lsterling@STPEGS.COM)" <lsterling@STPEGS.COM> | ||
Tracking Status: None | Tracking Status: None "cralbury@stpegs.com" <cralbury@stpegs.com> | ||
Tracking Status: None "Richards, Drew (amrichards@STPEGS.COM)" <amrichards@STPEGS.COM> | |||
Tracking Status: None "Brost, Wendy (webrost@STPEGS.COM)" <webrost@STPEGS.COM> | |||
Tracking Status: None Post Office: HQPWMSMRS01.nrc.gov Files Size Date & Time MESSAGE 912 12/9/2015 9:47:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: | |||
Recipients Received: | |||
NRR-PMDAPEm Resource From: Regner, Lisa Sent: Wednesday, December 09, 2015 9:47 AM To: Richards, Drew (amrichards@STPEGS.COM); Brost, Wendy (webrost@STPEGS.COM) | |||
Cc: Michael Murray; Sterling, Lance (lsterling@STPEGS.COM); cralbury@stpegs.com | |||
==Subject:== | ==Subject:== | ||
Additional STP RAI for Emergency CR | Additional STP RAI for Emergency CR Amendment | ||
: 7. On page 19 of 22 of your December 3, 2015, emergency amendment request, you state that 10 CFR 50.62(c)(3) concerning an alternate rod injection system as stated in Standard Review Plan, Section 4.6 are for boiling water reactors and do not apply to the South Texas Project Unit 1. The staff agrees that the BWR portion of the Anticipated Transient Without Scram (ATWS) rule, 10 CFR 50.62(c)(3), does not apply; however, the remainder of the ATWS rule, 10 CFR 50.62, should be considered by STP since it does apply to pressurized water reactors. Provide the impact on ATWS for STP considering the removal of control rod D6 | : Drew, As discussed, here is one additional questions to be answered on the docket so that the staff can complete its review of your emergency request for an amendment date December 3, 2015. | ||
: 7. On page 19 of 22 of your December 3, 2015, emergency amendment request, you state that 10 CFR 50.62(c)(3) concerning an alternate rod injection system as stated in Standard Review Plan, Section 4.6 are for boiling water reactors and do not apply to the South Texas Project Unit 1. The staff agrees that the BWR portion of the Anticipated Transient Without Scram (ATWS) rule, 10 CFR 50.62(c)(3), does not apply; however, the remainder of the ATWS rule, 10 CFR 50.62, should be considered by STP since it does apply to pressurized water reactors. Provide the impact on ATWS for STP considering the removal of control rod D6 | |||
: Thanks, Lisa Lisa Regner Sr. PM NRR/DORL/LPL4-1 301-415-1906 O8D08 1 | |||
Hearing Identifier: NRR_PMDA Email Number: 2620 Mail Envelope Properties (8aa2982b0d2b4caca27aa1404d28016e) | |||
==Subject:== | ==Subject:== | ||
Additional STP RAI for Emergency CR Amendment | Additional STP RAI for Emergency CR Amendment Sent Date: 12/9/2015 9:47:13 AM Received Date: 12/9/2015 9:47:00 AM From: Regner, Lisa Created By: Lisa.Regner@nrc.gov Recipients: | ||
Tracking Status: None | "Michael Murray" <mpmurray@STpegs.com> | ||
Tracking Status: None | Tracking Status: None "Sterling, Lance (lsterling@STPEGS.COM)" <lsterling@STPEGS.COM> | ||
Tracking Status: None | Tracking Status: None "cralbury@stpegs.com" <cralbury@stpegs.com> | ||
Tracking Status: None "Richards, Drew (amrichards@STPEGS.COM)" <amrichards@STPEGS.COM> | |||
Tracking Status: None "Brost, Wendy (webrost@STPEGS.COM)" <webrost@STPEGS.COM> | |||
Tracking Status: None Post Office: HQPWMSMRS01.nrc.gov Files Size Date & Time MESSAGE 912 12/9/2015 9:47:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: | |||
Recipients Received:}} |
Latest revision as of 19:44, 4 December 2019
ML16026A587 | |
Person / Time | |
---|---|
Site: | South Texas ![]() |
Issue date: | 12/09/2015 |
From: | Lisa Regner Plant Licensing Branch IV |
To: | Richards D South Texas |
References | |
MF7142 | |
Download: ML16026A587 (2) | |
Text
NRR-PMDAPEm Resource From: Regner, Lisa Sent: Wednesday, December 09, 2015 9:47 AM To: Richards, Drew (amrichards@STPEGS.COM); Brost, Wendy (webrost@STPEGS.COM)
Cc: Michael Murray; Sterling, Lance (lsterling@STPEGS.COM); cralbury@stpegs.com
Subject:
Additional STP RAI for Emergency CR Amendment
- Drew, As discussed, here is one additional questions to be answered on the docket so that the staff can complete its review of your emergency request for an amendment date December 3, 2015.
- 7. On page 19 of 22 of your December 3, 2015, emergency amendment request, you state that 10 CFR 50.62(c)(3) concerning an alternate rod injection system as stated in Standard Review Plan, Section 4.6 are for boiling water reactors and do not apply to the South Texas Project Unit 1. The staff agrees that the BWR portion of the Anticipated Transient Without Scram (ATWS) rule, 10 CFR 50.62(c)(3), does not apply; however, the remainder of the ATWS rule, 10 CFR 50.62, should be considered by STP since it does apply to pressurized water reactors. Provide the impact on ATWS for STP considering the removal of control rod D6
- Thanks, Lisa Lisa Regner Sr. PM NRR/DORL/LPL4-1 301-415-1906 O8D08 1
Hearing Identifier: NRR_PMDA Email Number: 2620 Mail Envelope Properties (8aa2982b0d2b4caca27aa1404d28016e)
Subject:
Additional STP RAI for Emergency CR Amendment Sent Date: 12/9/2015 9:47:13 AM Received Date: 12/9/2015 9:47:00 AM From: Regner, Lisa Created By: Lisa.Regner@nrc.gov Recipients:
"Michael Murray" <mpmurray@STpegs.com>
Tracking Status: None "Sterling, Lance (lsterling@STPEGS.COM)" <lsterling@STPEGS.COM>
Tracking Status: None "cralbury@stpegs.com" <cralbury@stpegs.com>
Tracking Status: None "Richards, Drew (amrichards@STPEGS.COM)" <amrichards@STPEGS.COM>
Tracking Status: None "Brost, Wendy (webrost@STPEGS.COM)" <webrost@STPEGS.COM>
Tracking Status: None Post Office: HQPWMSMRS01.nrc.gov Files Size Date & Time MESSAGE 912 12/9/2015 9:47:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received:
NRR-PMDAPEm Resource From: Regner, Lisa Sent: Wednesday, December 09, 2015 9:47 AM To: Richards, Drew (amrichards@STPEGS.COM); Brost, Wendy (webrost@STPEGS.COM)
Cc: Michael Murray; Sterling, Lance (lsterling@STPEGS.COM); cralbury@stpegs.com
Subject:
Additional STP RAI for Emergency CR Amendment
- Drew, As discussed, here is one additional questions to be answered on the docket so that the staff can complete its review of your emergency request for an amendment date December 3, 2015.
- 7. On page 19 of 22 of your December 3, 2015, emergency amendment request, you state that 10 CFR 50.62(c)(3) concerning an alternate rod injection system as stated in Standard Review Plan, Section 4.6 are for boiling water reactors and do not apply to the South Texas Project Unit 1. The staff agrees that the BWR portion of the Anticipated Transient Without Scram (ATWS) rule, 10 CFR 50.62(c)(3), does not apply; however, the remainder of the ATWS rule, 10 CFR 50.62, should be considered by STP since it does apply to pressurized water reactors. Provide the impact on ATWS for STP considering the removal of control rod D6
- Thanks, Lisa Lisa Regner Sr. PM NRR/DORL/LPL4-1 301-415-1906 O8D08 1
Hearing Identifier: NRR_PMDA Email Number: 2620 Mail Envelope Properties (8aa2982b0d2b4caca27aa1404d28016e)
Subject:
Additional STP RAI for Emergency CR Amendment Sent Date: 12/9/2015 9:47:13 AM Received Date: 12/9/2015 9:47:00 AM From: Regner, Lisa Created By: Lisa.Regner@nrc.gov Recipients:
"Michael Murray" <mpmurray@STpegs.com>
Tracking Status: None "Sterling, Lance (lsterling@STPEGS.COM)" <lsterling@STPEGS.COM>
Tracking Status: None "cralbury@stpegs.com" <cralbury@stpegs.com>
Tracking Status: None "Richards, Drew (amrichards@STPEGS.COM)" <amrichards@STPEGS.COM>
Tracking Status: None "Brost, Wendy (webrost@STPEGS.COM)" <webrost@STPEGS.COM>
Tracking Status: None Post Office: HQPWMSMRS01.nrc.gov Files Size Date & Time MESSAGE 912 12/9/2015 9:47:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received: