| issue date = 05/16/1991
| issue date = 05/16/1991
| title = Forwards Addl Info Re Inservice Testing Program for Plant Per Generic Ltr 89-04
| title = Forwards Addl Info Re Inservice Testing Program for Plant Per Generic Ltr 89-04
| author name = LABRUNA S
| author name = Labruna S
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY
| addressee name =  
| addressee name =  
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:' -\ Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hanccicks Bridge, NJ 08038 609-339-4800 Vice President  
{{#Wiki_filter:- \
-Nuclear Operations  
                                                '              Public Service Electric and Gas Company Stanley LaBruna                       Public Service Electric and Gas Company P.O. Box 236, Hanccicks Bridge, NJ 08038 609-339-4800 Vice President - Nuclear Operations
* &IAY 1 6 1991 NLR-N91063 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
                                                                            * &IAY 1 6 1991 NLR-N91063 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
ADDITIONAL INFORMATION REGARDING INSERVICE TESTING PROGRAM SALEM GENERATING STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 Public Service Electric & Gas Company (PSE&G) hereby submits, in Enclosures 1 and 2 to this letter, a revision to the Inservice Testing (IST) Program for Salem Unit Nos. 1 and 2. The current program for the second ten year cycle, was submitted in response to Generic Letter 89-04, by letter dated, October 3, 1989 (ref: NLR-N89196), and modified by letter dated, March 14, 1991 (ref: NLR-N91015).
ADDITIONAL INFORMATION REGARDING INSERVICE TESTING PROGRAM SALEM GENERATING STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 Public Service Electric & Gas Company (PSE&G) hereby submits, in Enclosures 1 and 2 to this letter, a revision to the Inservice Testing (IST) Program for Salem Unit Nos. 1 and 2. The current program for the second ten year cycle, was submitted in response to Generic Letter 89-04, by letter dated, October 3, 1989 (ref:
This request is submitted in accordance with Section 4.0.5 of Appendix A to Technical Specifications and Section XI of the ASME Boiler and Pressure Vessel Code. There are no additional relief requests included in this revision.
NLR-N89196), and modified by letter dated, March 14, 1991 (ref:
Enclosure 1 contains a list of changes to the IST Program. Enclosure 2 contains the replacement pages for the IST Program. Should there be any questions with regard to this submittal, please do not hesitate to contact us. Enclosures (2) ,' 9105220236 PDR ADOCK 05000272 p PDR Sincerely, 
NLR-N91015). This request is submitted in accordance with Section 4.0.5 of Appendix A to Technical Specifications and Section XI of the ASME Boiler and Pressure Vessel Code.
' . ' ::::= /--:;//, ./
There are no additional relief requests included in this revision.           Enclosure 1 contains a list of changes to the IST Program. Enclosure 2 contains the replacement pages for the IST Program.
Document Control Desk NLR-N91063 c Mr. J. c. Stone Licensing Project Manager Mr. T. Johnson senior Resident Inspector 2 Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Mr. Emanuel Mossa New Jersey Department of Labor and Industry PO Box 1503, Labor and Industry Building Trenton, NJ 08625 M' 1 6 1991 
Should there be any questions with regard to this submittal, please do not hesitate to contact us.
' ENCLOSURE 1 CHANGES TO THE IST PROGRAM 1 I I I I VALVE NUMBER 1AF128 1CC117 1CC195 1cc210 1DA70A 1DA70B 1DA70C 11DF36. 12DF36 11DF66 .12DF66 13DF66
Sincerely, Enclosures (2)
* ADDITIONAL CHANGES IN SALEM IST PROGRAM SUBMITTAL UNIT 1 CHANGES REMOVED VALVE FROM PROGRAM BECAUSE VALVE WAS REMOVED FROM SYSTEM. VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL VALVE 1CC146 WHICH IS KEPT CLOSED. DELETED VALVE FROM PROGRAM. SYSTEM.ISOLATION MAINTAINED BY MANUAL VALVE 1CC145 WHICH IS KEPT CLOSED. VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
,'     9105220236 910516---~
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
PDR         ADOCK 05000272 p                             PDR
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS -AN INTERNAL PUMP PRESSURE REGULATOR.
 
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
' .               ::::=
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
                    /--:;//,
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. *IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
Document Control Desk NLR-N91063
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
                          -----~
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
                                ./
--------------------------------------
2 M' 1 6 1991 c   Mr. J. c. Stone Licensing Project Manager Mr. T. Johnson senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Mr. Emanuel Mossa New Jersey Department of Labor and Industry PO Box 1503, Labor and Industry Building Trenton, NJ 08625
-----lSJlO 11SJ54 12SJ54 13SJ54 14SJ54 1SJ78 1SJ79 11SJ93 12SJ93 13SJ93 14SJ93 1SJ107 1SJ108 11SS93 13SS93. 14SS93
 
* VALVE REMOVED FROM SYSTEM. REMOVED VALVE FROM PROGRAM. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. BORON INJECTION TANK ISOLATED.
1
VALVE REMOVED FROM SYSTEM. BORON INJECTION TANK* ISOLATED.
'                           I I
VALVE REMOVED FROM SYSTEM. VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
I I
VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
ENCLOSURE 1 CHANGES TO THE IST PROGRAM
VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
 
VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
ADDITIONAL CHANGES IN SALEM IST PROGRAM SUBMITTAL UNIT 1 VALVE                               CHANGES NUMBER 1AF128         REMOVED VALVE FROM PROGRAM BECAUSE VALVE WAS REMOVED FROM SYSTEM.
BORON INJECTION TANK ISOLATED.
1CC117        VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
VALVE REMOVED FROM SYSTEM. BORON INJECTION TANK ISOLATED.
1CC195        DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL VALVE 1CC146 WHICH IS KEPT CLOSED.
VALVE REMOVED FROM. SYSTEM. VALVE HAS BEEN REMOVED FROM TECHNICAL  
1cc210        DELETED VALVE FROM PROGRAM. SYSTEM.ISOLATION MAINTAINED BY MANUAL VALVE 1CC145 WHICH IS KEPT CLOSED.
*SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. VALVE HAS BEEN REMOVED FROM TECHNICAL*
1DA70A        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. ,.  
1DA70B        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
-.:,-
1DA70C        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS -AN INTERNAL PUMP PRESSURE REGULATOR.
VALVE NUMBER 2CC117 2CC195 2CC210 2DA70A 2DA70B 2DA70C 21DF36 22DF36 21DF66 22DF66 23DF66
11DF36.        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
* ADDITIONAL CHANGES IN SALEM IST PROGRAM SUBMITTAL UNIT 2 CHANGES VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL VALVE 1CC146 WHICH IS KEPT CLOSED. DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL.VALVE 1CC145 WHICH IS KEPT CLOSED. . VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
12DF36        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
VALVE WAS IMPROPERLY DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
11DF66        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. *IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
.12DF66        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
13DF66        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
* VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
 
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR. -VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT*IS AN INTERNAL PUMP PRESSURE REGULATOR.
lSJlO VALVE REMOVED FROM SYSTEM. REMOVED VALVE FROM PROGRAM.
VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS *REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
11SJ54    VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
. 21SJ54 22SJ54 23SJ54 24SJ54 2SJ78 2SJ79 2SJ87 21SJ93 22SJ93 23SJ93 24SJ93 2SJ107 2SJ108 21SS93 22SS93 23SS93 24SS93
12SJ54   VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
* VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER *rs REMOVED. VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED. BORON INJECTION TANK ISOLATED.
13SJ54    VALVE REMOVED FROM PROGRAM. THE VALVE IS                  ,. ~-*;." - .:,-
VALVE FROM SYSTEM. BORON INJECTION TANK ISOLATED.
ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
VALVE REMOVED FROM SYSTEM. TANK TEMPERATURE MONITORED DAILY. VALVE HAS NO SAFETY FUNCTION.
14SJ54    VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
REMOVED FROM PROGRAM. VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
1SJ78    BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.
VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
1SJ79    BORON INJECTION TANK* ISOLATED. VALVE REMOVED FROM SYSTEM.
VALVE REMOVED FROM.PROGRAM.
11SJ93    VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
VALVE IS* A PASSIVE VALVE WITH NO SAFETY FUNCTION.
12SJ93    VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
13SJ93    VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
BORON INJECTION TANK ISOLATED.
14SJ93    VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
VALVE REMOVED FROM SYSTEM. BORON INJECTION TANK ISOLATED.
1SJ107    BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.
VALVE REMOVED FROM SYSTEM. VALVE HAS BEEN REMOVED FROM TECHNICAL  
1SJ108    BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM.
*SPECIFICATIONS AS A CONTAINMENT ISOLATIQN VALVE. VALVE HAS BEEN REMOVED FROM TECHNICAL  
SYSTEM.
*SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE. *vALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.}}
11SS93    VALVE HAS BEEN REMOVED FROM TECHNICAL
        *SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
12SS9~,_  VALVE HAS BEEN REMOVED FROM TECHNICAL*
SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
13SS93. VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
14SS93    VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
 
ADDITIONAL CHANGES IN SALEM IST PROGRAM SUBMITTAL UNIT 2 VALVE                                CHANGES NUMBER 2CC117        VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
2CC195        DELETED VALVE FROM PROGRAM.                     SYSTEM ISOLATION MAINTAINED BY MANUAL VALVE 1CC146 WHICH IS KEPT CLOSED.
2CC210        DELETED VALVE FROM PROGRAM.                     SYSTEM ISOLATION MAINTAINED BY MANUAL.VALVE 1CC145 WHICH IS KEPT CLOSED.
                                      '>:-~ ~'J.*::r;~ef~~i~J.;ii;i~ ~?. :;:,,.~~ .
2DA70A        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE.             IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
2DA70B        VALVE WAS IMPROPERLY ~DENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE.             IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
2DA70C        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
21DF36        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE.             IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
* 22DF36        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE.             IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
21DF66        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE.             IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
22DF66        -VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE.             IT*IS AN INTERNAL PUMP PRESSURE REGULATOR.
23DF66        VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS
              *REVIEW AS RELIEVE VALVE.             IT IS AN INTERNAL PUMP PRESSURE REGULATOR.
 
.21SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
22SJ54  VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
23SJ54  VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER *rs REMOVED.
24SJ54  VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.
2SJ78  BORON INJECTION TANK ISOLATED. VALVE REMOV~D  FROM SYSTEM.
2SJ79  BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.
2SJ87  TANK TEMPERATURE MONITORED DAILY. VALVE HAS NO SAFETY FUNCTION. REMOVED FROM PROGRAM.
21SJ93  VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
22SJ93  VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
23SJ93  VALVE REMOVED FROM.PROGRAM. VALVE IS* A PASSIVE VALVE WITH NO SAFETY FUNCTION.
24SJ93  VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.
2SJ107  BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.
2SJ108  BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.
21SS93  VALVE HAS BEEN REMOVED FROM TECHNICAL
        *SPECIFICATIONS AS A CONTAINMENT ISOLATIQN VALVE.
22SS93  VALVE HAS BEEN REMOVED FROM TECHNICAL
        *SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE~
23SS93  VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.
24SS93 *vALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.}}

Revision as of 05:47, 3 February 2020

Forwards Addl Info Re Inservice Testing Program for Plant Per Generic Ltr 89-04
ML18095A936
Person / Time
Site: Salem  PSEG icon.png
Issue date: 05/16/1991
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18095A937 List:
References
GL-89-04, GL-89-4, NLR-N91063, NUDOCS 9105220236
Download: ML18095A936 (7)


Text

- \

' Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hanccicks Bridge, NJ 08038 609-339-4800 Vice President - Nuclear Operations

  • &IAY 1 6 1991 NLR-N91063 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

ADDITIONAL INFORMATION REGARDING INSERVICE TESTING PROGRAM SALEM GENERATING STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 Public Service Electric & Gas Company (PSE&G) hereby submits, in Enclosures 1 and 2 to this letter, a revision to the Inservice Testing (IST) Program for Salem Unit Nos. 1 and 2. The current program for the second ten year cycle, was submitted in response to Generic Letter 89-04, by letter dated, October 3, 1989 (ref:

NLR-N89196), and modified by letter dated, March 14, 1991 (ref:

NLR-N91015). This request is submitted in accordance with Section 4.0.5 of Appendix A to Technical Specifications and Section XI of the ASME Boiler and Pressure Vessel Code.

There are no additional relief requests included in this revision. Enclosure 1 contains a list of changes to the IST Program. Enclosure 2 contains the replacement pages for the IST Program.

Should there be any questions with regard to this submittal, please do not hesitate to contact us.

Sincerely, Enclosures (2)

,' 9105220236 910516---~

PDR ADOCK 05000272 p PDR

' .  ::::=

/--:;//,

Document Control Desk NLR-N91063


~

./

2 M' 1 6 1991 c Mr. J. c. Stone Licensing Project Manager Mr. T. Johnson senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Mr. Emanuel Mossa New Jersey Department of Labor and Industry PO Box 1503, Labor and Industry Building Trenton, NJ 08625

1

' I I

I I

ENCLOSURE 1 CHANGES TO THE IST PROGRAM

ADDITIONAL CHANGES IN SALEM IST PROGRAM SUBMITTAL UNIT 1 VALVE CHANGES NUMBER 1AF128 REMOVED VALVE FROM PROGRAM BECAUSE VALVE WAS REMOVED FROM SYSTEM.

1CC117 VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

1CC195 DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL VALVE 1CC146 WHICH IS KEPT CLOSED.

1cc210 DELETED VALVE FROM PROGRAM. SYSTEM.ISOLATION MAINTAINED BY MANUAL VALVE 1CC145 WHICH IS KEPT CLOSED.

1DA70A VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

1DA70B VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

1DA70C VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS -AN INTERNAL PUMP PRESSURE REGULATOR.

11DF36. VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

12DF36 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

11DF66 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. *IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

.12DF66 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

13DF66 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

lSJlO VALVE REMOVED FROM SYSTEM. REMOVED VALVE FROM PROGRAM.

11SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

12SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

13SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ,. ~-*;." - .:,-

ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

14SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

1SJ78 BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.

1SJ79 BORON INJECTION TANK* ISOLATED. VALVE REMOVED FROM SYSTEM.

11SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

12SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

13SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

14SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

1SJ107 BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.

1SJ108 BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM.

SYSTEM.

11SS93 VALVE HAS BEEN REMOVED FROM TECHNICAL

  • SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

12SS9~,_ VALVE HAS BEEN REMOVED FROM TECHNICAL*

SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

13SS93. VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

14SS93 VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

ADDITIONAL CHANGES IN SALEM IST PROGRAM SUBMITTAL UNIT 2 VALVE CHANGES NUMBER 2CC117 VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

2CC195 DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL VALVE 1CC146 WHICH IS KEPT CLOSED.

2CC210 DELETED VALVE FROM PROGRAM. SYSTEM ISOLATION MAINTAINED BY MANUAL.VALVE 1CC145 WHICH IS KEPT CLOSED.

'>:-~ ~'J.*::r;~ef~~i~J.;ii;i~ ~?. :;:,,.~~ .

2DA70A VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

2DA70B VALVE WAS IMPROPERLY ~DENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

2DA70C VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

21DF36 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

  • 22DF36 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

21DF66 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

22DF66 -VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS REVIEW AS RELIEVE VALVE. IT*IS AN INTERNAL PUMP PRESSURE REGULATOR.

23DF66 VALVE WAS IMPROPERLY IDENTIFIED DURING PREVIOUS

  • REVIEW AS RELIEVE VALVE. IT IS AN INTERNAL PUMP PRESSURE REGULATOR.

.21SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

22SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

23SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER *rs REMOVED.

24SJ54 VALVE REMOVED FROM PROGRAM. THE VALVE IS ADMINISTRATIVELY LOCKED OPEN AND POWER IS REMOVED.

2SJ78 BORON INJECTION TANK ISOLATED. VALVE REMOV~D FROM SYSTEM.

2SJ79 BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.

2SJ87 TANK TEMPERATURE MONITORED DAILY. VALVE HAS NO SAFETY FUNCTION. REMOVED FROM PROGRAM.

21SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

22SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

23SJ93 VALVE REMOVED FROM.PROGRAM. VALVE IS* A PASSIVE VALVE WITH NO SAFETY FUNCTION.

24SJ93 VALVE REMOVED FROM PROGRAM. VALVE IS A PASSIVE VALVE WITH NO SAFETY FUNCTION.

2SJ107 BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.

2SJ108 BORON INJECTION TANK ISOLATED. VALVE REMOVED FROM SYSTEM.

21SS93 VALVE HAS BEEN REMOVED FROM TECHNICAL

  • SPECIFICATIONS AS A CONTAINMENT ISOLATIQN VALVE.

22SS93 VALVE HAS BEEN REMOVED FROM TECHNICAL

  • SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE~

23SS93 VALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.

24SS93 *vALVE HAS BEEN REMOVED FROM TECHNICAL SPECIFICATIONS AS A CONTAINMENT ISOLATION VALVE.