ML110030843: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
(One intermediate revision by the same user not shown) | |||
Line 5: | Line 5: | ||
| author name = Chan T | | author name = Chan T | ||
| author affiliation = - No Known Affiliation | | author affiliation = - No Known Affiliation | ||
| addressee name = Michel E | | addressee name = Michel E | ||
| addressee affiliation = NRC/RGN-II | | addressee affiliation = NRC/RGN-II | ||
| docket = 05000269, 05000270, 05000287 | | docket = 05000269, 05000270, 05000287 | ||
Line 16: | Line 16: | ||
=Text= | =Text= | ||
{{#Wiki_filter:t Stamm, Eric From: Chan, Terence Sent: Thursday, September 03, 2009 6:07 PM To: Michel, Eric Cc: Tsao, John; Franke, Mark; Riggs, Eric | {{#Wiki_filter:t Stamm, Eric From: Chan, Terence Sent: Thursday, September 03, 2009 6:07 PM To: Michel, Eric Cc: Tsao, John; Franke, Mark; Riggs, Eric | ||
==Subject:== | ==Subject:== | ||
RE: OC SSF ASW leak Thanks. I'll have John Tsao take a look at it.From: Michel, Eric Sent: Friday, August 28, 2009 9:28 AM To: Chan, Terence Cc: Tsao, John; Franke, Mark; Riggs, Eric | RE: OC SSF ASW leak Thanks. I'll have John Tsao take a look at it. | ||
From: Michel, Eric Sent: Friday, August 28, 2009 9:28 AM To: Chan, Terence Cc: Tsao, John; Franke, Mark; Riggs, Eric | |||
==Subject:== | ==Subject:== | ||
OCO SSF ASW leak Terence, We received the OCO operability determination for their SSF ASW piping leak yesterday. | OCO SSF ASW leak | ||
We'd appreciate someone taking a look at the sections associated with the ASME Code compliance (GL 90-05), and the water hammer evaluation. | : Terence, We received the OCO operability determination for their SSF ASW piping leak yesterday. We'd appreciate someone taking a look at the sections associated with the ASME Code compliance (GL 90-05), and the water hammer evaluation. The overall PDO starts on page 3, the water hammer analysis starts on page 5, and the Code compliance section starts on page 10. Of course, if you find any other areas of concern we'd appreciate your thoughts. Thanks. | ||
The overall PDO starts on page 3, the water hammer analysis starts on page 5, and the Code compliance section starts on page 10. Of course, if you find any other areas of concern we'd appreciate your thoughts. | Eric 1 | ||
Thanks.Eric 1 Y(O""'}} | Y(O""'}} |
Latest revision as of 04:56, 13 November 2019
ML110030843 | |
Person / Time | |
---|---|
Site: | Oconee |
Issue date: | 09/03/2009 |
From: | Chan T - No Known Affiliation |
To: | Eric Michel NRC/RGN-II |
References | |
FOIA/PA-2011-0021 | |
Download: ML110030843 (1) | |
Text
t Stamm, Eric From: Chan, Terence Sent: Thursday, September 03, 2009 6:07 PM To: Michel, Eric Cc: Tsao, John; Franke, Mark; Riggs, Eric
Subject:
RE: OC SSF ASW leak Thanks. I'll have John Tsao take a look at it.
From: Michel, Eric Sent: Friday, August 28, 2009 9:28 AM To: Chan, Terence Cc: Tsao, John; Franke, Mark; Riggs, Eric
Subject:
OCO SSF ASW leak
- Terence, We received the OCO operability determination for their SSF ASW piping leak yesterday. We'd appreciate someone taking a look at the sections associated with the ASME Code compliance (GL 90-05), and the water hammer evaluation. The overall PDO starts on page 3, the water hammer analysis starts on page 5, and the Code compliance section starts on page 10. Of course, if you find any other areas of concern we'd appreciate your thoughts. Thanks.
Eric 1
Y(O""'