{{#Wiki_filter:ARTICLE IWA-2000 EXAMINATION AND INSPECTION IW A-2100 GENERAL A02 IWA-2110 DUTIES OF THE INSPECTOR (a) The Inspector shall review the inspection plan and, as necessary, the implementation schedule (IWA-2420) prior to the start of preservice inspection and each inspection interval.
{{#Wiki_filter:ENT000531 Submitted: August 20, 2012 ARTICLE IWA-2000 EXAMINATION AND INSPECTION IWA-2100 GENERAL                                           the Owner's agent and qualified in accordance with IWA-2300.
The review shall cover any features that are affected by the requirements of this Division, as applicable, and shall include the following: ( 1) examination categories and items (2) test and examination requirements (3) examination methods (4) percentage of parts selected for examination (5) disposition of test results (6) test frequency (7) system pressure tests (8) sequence of successive examinations Shop and field preservice examinations are exempt from prior review. (b) The Inspector shall review any revisions to the inspection plan and, as necessary, the implementation schedule during the preservice inspection or the tion interval. (c) The Inspector shall submit a report to the Owner documenting review of the items identified in IWA-211O(a) and (b). (d) The Inspector shall verify that the required nations and system pressure tests have been performed and the results recorded.
A02 IWA-2110 DUTIES OF THE INSPECTOR (h) The Inspector may require, at any time, requalifi-(a) The Inspector shall review the inspection plan     cation of any procedure or operator if the Inspector and, as necessary, the implementation schedule (IWA-       has reason to believe that the requirements are not 2420) prior to the start of preservice inspection and     being met.
the Owner's agent and qualified in accordance with IWA-2300. (h) The Inspector may require, at any time, cation of any procedure or operator if the Inspector has reason to believe that the requirements are not being met. (i) The Inspector shall certify the examination ords after verifying that the requirements have been met and that the records are correct. (j) The Inspector shall verify that repair /replacement activities are performed in accordance with the ments of the Owner's Repair/Replacement Program. (k) The Inspector shall review the ment Program and its implementation.
each inspection interval. The review shall cover any           (i) The Inspector shall certify the examination rec-features that are affected by the requirements of this     ords after verifying that the requirements have been Division, as applicable, and shall include the following: met and that the records are correct.
IW A-2120 QUALIFICATION OF AUTHORIZED INSPECTION AGENCIES, INSPECTORS, AND SUPERVISORS (a) The inspection required by this Division shall be performed: ( 1) where the plant is in the United States, by an Inspector employed by a State or Municipality of the United States or an Inspector regularly employed by an insurance company authorized to write boiler and pressure vessel insurance in the United States; where the plant is in Canada, by an Inspector a Canadian Province or, if authorized A02 A03 IWA*2120 GENERAL REQUIREMENTS IWA*2213 ( c) The Authorized Inspection Agency shall be credited by AS ME in accordance with the provisions set forth in ASME QAI-l. IWA-2130 ACCESS FOR INSPECTOR The Owner shall arrange for an Inspector to have access to all parts of the plant as necessary to make the required inspections.
( 1) examination categories and items                     (j) The Inspector shall verify that repair /replacement (2) test and examination requirements                 activities are performed in accordance with the require-(3) examination methods                               ments of the Owner's Repair/Replacement Program.
The Owner shall keep the Inspector informed of the progress of the preparatory work necessary to permit inspections and shall notify the Inspector at a time reasonably in advance of when the components will be ready for inspection.
(k) The Inspector shall review the Repair/Replace-(4) percentage of parts selected for examination ment Program and its implementation.
IWA-2200 EXAMINATION METHODS (a) The three types of examinations used during inservice inspection are defined as visual, surface, and volumetric.
(5) disposition of test results (6) test frequency (7) system pressure tests (8) sequence of successive examinations IWA-2120 QUALIFICATION OF Shop and field preservice examinations are exempt from AUTHORIZED INSPECTION prior review.
The examination method to be used is specified in Tables IWB-, IWC-, IWD-, IWE-, IWF-, and IWL-2S00-1.
AGENCIES, INSPECTORS, AND (b) The Inspector shall review any revisions to the                   SUPERVISORS inspection plan and, as necessary, the implementation schedule during the preservice inspection or the inspec-      (a) The inspection required by this Division shall tion interval.                                             be performed:
If a component must be examined in a high radiation area, remotely controlled equipment may be advisable. (b) When preparation of a surface for nondestructive examination is required, the preparation shall be by a mechanical method. Such surfaces shall be blended into the surrounding area as may be required to perform the examination.
(c) The Inspector shall submit a report to the Owner           (1) where the plant is in the United States, by an documenting review of the items identified in IWA-        Inspector employed by a State or Municipality of the 211O(a) and (b).                                          United States or an Inspector regularly employed by an insurance company authorized to write boiler and (d) The Inspector shall verify that the required exami-pressure vessel insurance in the United States; nations and system pressure tests have been performed where the plant is in Canada, by an Inspector and the results recorded.
The wall thickness shall not be reduced below the minimum thickness required by design. mandatory Appendix D may be used for such surface preparation.
a Canadian Province or, if authorized
IWA-2210 VISUAL EXAMINATIONS Visual examinations shall be conducted in accordance with Section V, Article 9, T-941 for Written Procedures, and T-990 for Report of Examination Results. (d) Illumination for examination shall meet the quirements specified in Table IWA-2211-1. (e) It is not necessary to measure the illumination level on each examination surface when the same portable nonbattery-powered light source (e.g., drop light) or similar installed lighting equipment is strated to provide the illumination specified at the maximum examination distance. (f) When a battery-powered light is used, the quacy of the illumination level shall be checked before and after each examination or series of examinations, not to exceed 4 hr between checks. (g) Remote visual examination may be substituted for direct examination.
 
The remote examination dure shall be demonstrated capable of resolving ters in accordance with Table IWA-221l-1. ally, the remote examination system shall be capable of distinguishing the colors applicable to the component examination being conducted.
IWA*2120                                   GENERAL REQUIREMENTS                                         IWA*2213 (c) The Authorized Inspection Agency shall be ac-         (d) Illumination for examination shall meet the re-credited by AS ME in accordance with the provisions      quirements specified in Table IWA-2211-1.
IWA-2212 VT-2 Examination A03 (a) VT-2 examination is conducted to detect evidence of leakage from pressure retaining components, with or without leakage collection systems, as required during the system pressure test. (b) VT-2 examination shall be conducted in ance with IWA-SOOO.
set forth in ASME QAI-l.                                      (e) It is not necessary to measure the illumination level on each examination surface when the same portable nonbattery-powered light source (e.g., drop IWA-2130 ACCESS FOR INSPECTOR                            light) or similar installed lighting equipment is demon-strated to provide the illumination specified at the The Owner shall arrange for an Inspector to have      maximum examination distance.
IWA-2213 VT-3 Examination A03 (a) VT-3 examination is conducted to determine the general mechanical and structural condition of nents and their supports by verifying parameters such as clearances, settings, and physical displacements; to detect discontinuities and imperfections, such as loss of integrity at bolted or welded connections, loose or missing parts, debris, corrosion, wear, or erosion; and to detect conditions that could affect operability or functional adequacy of snubbers and constant load and A02 A03 IWA-2213 2001 SECTION XI, DIVISION 1 IWA-2224 TABLE IWA-221l-1 VISUAL EXAMINATIONS Minimum Maximum Height, in. (mm), Illumination, Maximum Direct for Procedure Visual fc Examination Distance, Demonstration Examination
access to all parts of the plant as necessary to make          (f) When a battery-powered light is used, the ade-the required inspections. The Owner shall keep the        quacy of the illumination level shall be checked before Inspector informed of the progress of the preparatory    and after each examination or series of examinations, work necessary to permit inspections and shall notify    not to exceed 4 hr between checks.
[Note (1)] ft (mm) Characters
the Inspector at a time reasonably in advance of when        (g) Remote visual examination may be substituted the components will be ready for inspection.              for direct examination. The remote examination proce-dure shall be demonstrated capable of resolving charac-ters in accordance with Table IWA-221l-1. Addition-IWA-2200 EXAMINATION METHODS                              ally, the remote examination system shall be capable of distinguishing the colors applicable to the component (a) The three types of examinations used during examination being conducted.
[Note (2)] VT-l 50 2 (600) 0.044 n.O) VT-3 50 N/A 0.105 0.0) NOTES: (1) Resolution ofthe specified characters can be used in lieu of illumination measurement to verify illumination adequacy.
inservice inspection are defined as visual, surface, and volumetric. The examination method to be used is specified in Tables IWB-, IWC-, IWD-, IWE-, IWF-,        IWA-2212 VT-2 Examination                                 A03 and IWL-2S00-1. If a component must be examined in a high radiation area, remotely controlled equipment      (a) VT-2 examination is conducted to detect evidence may be advisable.                                        of leakage from pressure retaining components, with (b) When preparation of a surface for nondestructive  or without leakage collection systems, as required during examination is required, the preparation shall be by a    the system pressure test.
(2) For procedure demonstration, a test chart or card containing text with some lowercase characters, without an ascender or descender (e.g., a, c, e, 0), that meet the specified height requirements is required.
mechanical method. Such surfaces shall be blended              (b) VT-2 examination shall be conducted in accord-into the surrounding area as may be required to perform    ance with IWA-SOOO.
the examination. The wall thickness shall not be reduced below the minimum thickness required by design. Non-IWA-2213 VT-3 Examination                                 A03 mandatory Appendix D may be used for such surface preparation.                                                  (a) VT-3 examination is conducted to determine the general mechanical and structural condition of compo-nents and their supports by verifying parameters such A02 IWA-2210 VISUAL EXAMINATIONS                              as clearances, settings, and physical displacements; to A03                                                          detect discontinuities and imperfections, such as loss Visual examinations shall be conducted in accordance  of integrity at bolted or welded connections, loose or with Section V, Article 9, T-941 for Written Procedures,  missing parts, debris, corrosion, wear, or erosion; and and T-990 for Report of Examination Results.              to detect conditions that could affect operability or functional adequacy of snubbers and constant load and
 
IWA-2213                                             2001 SECTION XI, DIVISION 1                                                 IWA-2224 A02                                                            TABLE IWA-221l-1 A03                                                          VISUAL EXAMINATIONS Minimum                                                   Maximum Height, in. (mm),
Illumination,               Maximum Direct                         for Procedure Visual                   fc               Examination Distance,                       Demonstration Examination             [Note   (1)]                   ft (mm)                       Characters [Note (2)]
VT-l                     50                         2 (600)                             0.044 n.O)
VT-3                     50                         N/A                                 0.105 0.0)
NOTES:
(1) Resolution ofthe specified characters can be used in lieu of illumination measurement to verify illumination adequacy.
(2) For procedure demonstration, a test chart or card containing text with some lowercase characters, without an ascender or descender (e.g., a, c, e, 0), that meet the specified height requirements is required.
Measurements of the test chart or card shall be made once before its initial use with an optical comparator (lax or greater) or other suitable instrument to verify that the height of the lowercase characters without an ascender or descender meets the specified requirements.
Measurements of the test chart or card shall be made once before its initial use with an optical comparator (lax or greater) or other suitable instrument to verify that the height of the lowercase characters without an ascender or descender meets the specified requirements.
light) or similar installed lighting equipment is strated to provide the illumination specified in Table IW A -2211-1 at the maximum examination distance. (f) a battery-powered light is used, the quacy of the illumination level shall be checked before and after each examination or series of examinations, not to exceed 4 hr between checks. (g) Remote visual examination may be substituted for direct examination.
light) or similar installed lighting equipment is demon-                          ( c) Any flaw recorded by ultrasonic examination shall strated to provide the illumination specified in Table                       be compared to the volumetric examination acceptance IW A -2211-1 at the maximum examination distance.                             standards of Table IWB-3514-1 or Table IWB-3514-2 (f) Whl~n a battery-powered light is used, the ade-                      for surface planar flaw.
The remote examination dure shall be demonstrated capable of resolving ters in accordance with Table IWA-2211-1. ally, the remote visual examination system shall be capable of distinguishing the colors applicable to the component examinations being conducted.
quacy of the illumination level shall be checked before and after each examination or series of examinations, not to exceed 4 hr between checks.
IWA-221S Replication Surface replication methods may be used for VT-I and VT-3 examinations when the surface resolution is at least equivalent to that of direct visual observation. ( c) Any flaw recorded by ultrasonic examination shall be compared to the volumetric examination acceptance standards of Table IWB-3514-1 or Table IWB-3514-2 for surface planar flaw. IWA-2221 Magnetic Particle Examination (a) Magnetic particle examination shall be conducted in accordance with Section V, Article 7. ( b) Magnetic particle examination of coated materials shall be conducted in accordance with Section V, Article 7, Appendix I. IW A-2222 Liquid Penetrant Examination Liquid penetrant examination shall be conducted in accordance with Section V, Article 6. IWA-2223 Eddy Current Examination IWA*2230 GENERAL REQUIREMENTS IWA*2231 IWA*2230 VOLUMETRIC EXAMINATION A volumetric examination indicates the presence of discontinuities throughout the volume of material and may be conducted from either the inside or outside surface of a component.
IWA-2221        Magnetic Particle Examination (g) Remote visual examination may be substituted for direct examination. The remote examination proce-                            (a) Magnetic particle examination shall be conducted dure shall be demonstrated capable of resolving charac-                      in accordance with Section V, Article 7.
IWA-2231 Radiographic Examination Radiographic techniques, employing penetrating ation such as X-rays, gamma rays, or thermalized neutrons, may be utilized with appropriate cording devices, such as photographic film or papers, electrostatic systems, direct-image orthicons, or image converters.
ters in accordance with Table IWA-2211-1. Addition-                              ( b) Magnetic particle examination of coated materials ally, the remote visual examination system shall be                         shall be conducted in accordance with Section V, Article capable of distinguishing the colors applicable to the                       7, Appendix I.
For radiographic examinations employing either X-ray equipment or radioactive isotopes and photographic films, the procedure shall be as specified in Article 2 of Section V.
component examinations being conducted.
IWA-221S Replication                                                         IW A-2222 Liquid Penetrant Examination Surface replication methods may be used for VT-I                             Liquid penetrant examination shall be conducted in and VT-3 examinations when the surface resolution is                         accordance with Section V, Article 6.
at least equivalent to that of direct visual observation.
IWA-2223 Eddy Current Examination
 
IWA*2230                                  GENERAL REQUIREMENTS                                        IWA*2231 IWA*2230      VOLUMETRIC EXAMINATION                    neutrons, may be utilized with appropriate image-re-cording devices, such as photographic film or papers, A volumetric examination indicates the presence of electrostatic systems, direct-image orthicons, or image discontinuities throughout the volume of material and converters. For radiographic examinations employing may be conducted from either the inside or outside either X-ray equipment or radioactive isotopes and surface of a component.
photographic films, the procedure shall be as specified in Article 2 of Section V.
IWA-2231      Radiographic Examination Radiographic techniques, employing penetrating radi-ation such as X-rays, gamma rays, or thermalized
 
IWA-2232                                    GENERAL REQUIREMENTS                                        IWA-2311 IWA-2232 Ultrasonic Examination                          to the original schedule of successive inspections of IWB-2410 or IWC-2410, as applicable.
Ultrasonic examination shall be conducted in accord-ance with Appendix I.
IW A-2240 ALTERNA TIVE EXAMINATIONS                        A02 IWA-2233 Eddy Current Examination                           Alternative examination methods, a combination of methods, or newly developed techniques may be substi-Eddy current examination shall be conducted in         tuted for the methods specified in the Construction accordance with Section V, Article 8, Appendix II.        Code or this Division, provided the Inspector is satisfied that the results are demonstrated to be equivalent or superior to those of the specified method.
IWA-2234 Acoustic Emission Examination Acoustic emission may be used in lieu of the succes-sive inspections of IWB-2420(b) or IWC-2420(b) to        IWA-2300 QUALIFICATIONS OF monitor growth of flaws detected by other NDE meth-                      NONDESTRUCTIVE ods. The flaws shall be sized by ultrasonic examination                 EXAMINATION PERSONNEL in accordance with Appendix I, Supplement 12, prior        IW A-2310 GENERAL to initiating use of acoustic emission. Acoustic emission monitoring shall be initiated prior to resuming operation    (a) Personnel performing nondestructive examina-of the system. Acoustic emission shall be conducted       tions (NDE) shall be qualified and certified using a in accordance with Section V, Article 13, with the        written practice prepared in accordance with following additional requirements.                        ANSI! ASNT CP-189, Standard for Qualification and (a) The following flaw growth calculation and accept-  Certification of Nondestructive Testing Personnel, as ance criteria shall be used.                              amended by the requirements of this Division. Certifica-( 1) Every two months during the current inspection tions based on SNT-TC-IA, ANSI N4S.2.6, or earlier period, calculate the flaw growth in accordance with      editions of ANSI! ASNT CP-189 are valid until recerti-Section V, Article 13, Appendix I. Using this growth      fication is required. Recertification shall be in accord-rate, predict the flaw size at the end of the current      ance with the edition of ANSI! ASNT CP-189 referenced inspection period.                                        in IW A-1600 as amended by the requirements of this (2) If the calculated flaw size at the end of the    Division. Outside agencies, as defined in Appendix VII, current inspection period meets the acceptance criteria    may be used to qualify NDE personnel; however, the of IWB-3600 or IWC-3600, as applicable, continue the      Employer shall be solely responsible for the certification two-month monitoring process described in (1) above.      of Levels I, II, and III personnel. Nondestructive and visual examination personnel qualified and certified in (3) If the calculated flaw size at the end of the accordance with the requirements of this Division are current inspection period does not meet the acceptance qualified and certified to perform examinations in ac-criteria of IWB-3600 or IWC-3600, as applicable, the cordance with the requirements of previous Editions following actions shall be performed.
and Addenda.
Calculate the flaw size at the end of the next two-month time span. If this calculated flaw size
 
IWA-2312                                      2001 SECTION XI, DIVISION 1                                      IWA-2321 IW A-2312    NDE Methods Listed in ANSI! ASNT                IWA-2316        Alternative Qualifications of VT-2 CP-189                                                          Visual Examination Personnel (a) Qualifications shall be based on the methods,              (a) In lieu of the requirements of IWA-231O through techniques, procedures, and equipment used for the            IWA-2314, VT-2 visual examination personnel may be NDE required by this Division.                                qualified by satisfying the following requirements:
(b) Training, qualification, and certification of ultra-          ( I) at least 40 hr plant walkdown experience, such sonic examination personnel shall also comply with            as that gained by licensed and nonlicensed operators, the requirements of Appendix VII.                              local leak rate personnel, system engineers, quality (c) Training, qualification, and certification of visual  control personnel, and nondestructive examination per-examination personnel shall comply with the require-          sonnel ments of Appendix VI.                                                (2) at least 4 hr of training in the Section XI (d) The visual examination training and experience        requirements and plant-specific procedures for VT-2 hours specified in CP-189 shall be applied to the              visual examination combined certification of an individual for VT-l, VT-                (3) the vision test requirements of IWA-2321 2, and VT-3 visual examination. Certification in only            (b) These alternative qualification requirements shall one of the VT techniques is a limited certification, and      be described in the Employer's written practice.
the requirements of IW A-2350 apply.
IWA-2317          Alternative Qualifications of VT-3 IW A-2313    NDE Methods Not Listed in                                        Visual Examination Personnel ANSI! ASNT CP-189 (a) In lieu of the requirements of IWA-231O through Personnel using NDE methods not addressed in              IWA-2314, VT-3 visual examination personnel may be ANSI/ASNT CP-189 shall be qualified as defined in            qualified by satisfying the following requirements:
ANSI! ASNT CP-189 or the ACCP and the Employer's                    ( I) at least 40 hours plant experience, such as written practice.                                            that gained by plant personnel involved in installation, maintenance, or examination of pumps, valves, and supports, quality control personnel, and nondestructive IWA-2314      Certification and Recertification              examination personnel (a) Personnel shall be qualified by examination and              (2) at least 8 hr of training in the Section XI shall be certified in accordance with ANSII ASNT CP-          requirements and plant-specific procedures for VT-3 189, except that the ASNT Level III certificate is not        visual examination required. Levels I, II, and III personnel shall be recerti-          (3) the vision test requirements of IWA-2321 fied by qualification examinations every 5 years.                ( b) The alternative qualification requirements shall (b) Personnel qualified in accordance with the ACCP        be described in the Employer's written practice.
shall be recertified by examination every 5 years.
(c) An ACCP certificate with current endorsements obtained by examination satisfies the General and Prac-        IW A-2320        QUALIFICA TION EXAMINATIONS tice Examination requirements for Levels I and II NDE personnel.                                                    IWA-2321          Vision Tests be administered
 
IWA-2321                                              GENERAL REQUIREMENTS                                                   IWA-2323 TABLE IWA-2322-1                                          (3) At least fifteen (IS) questions that are similar NEAR-DISTANCE ACUITY TEST DISTANCES                              to published Level II questions for other NDT methods.
AND CHARACTER HEIGHTS (b) The Method Examination shall consist of at least Maximum Lower Case          65 questions:
Test Distance,                                Character Height,
( 1) At least thirty (30) questions related to funda-in. (mm)                                      in. (mm) mentals and principles that are similar to published 12  (05)                                    0.022  (0.56)          ASNT Level III questions for each method.
13  (30)                                    0.024  (0.61)
(2) At least fifteen (15) questions related to applica-14  (56)                                    0.025  (0.63) 15  (81)                                    0.027  (0.68) tion and establishment of procedures and techniques 16  (406)                                    0.029  (0.73)          that are similar to published ASNT Level III questions for each method.
NOTE: The test distances (eye to chart) and corresponding character (3) At least twenty (20) questions related to capa-heights provide a visual angle of 6.25 minutes, which is equivalent to a Snellen fraction of 20/25.                                          bility for interpreting codes, standards, and specifications related to the method.
(e) The Specific Examination shall contain at least 30 questions covering equipment, techniques, proce-dures, and administration of the Employer's written
( b) Personnel shall demonstrate the capability to dis-              practice. The Specific Examination shall also cover the tinguish the colors applicable to the NDE methods for                    NDE requirements of this Division, including acceptance which certified and to differentiate contrast between                    standards and referenced codes and standards.
these colors.                                                                (d) The Practical Examination shall be in accordance with ANSI/ASNT CP-189 requirements.
(e) An ASNT Level III certificate with current en-IWA-2322 Near-Distance Test Chart                                        dorsements obtained by examination for the applicable Qualification                                          method satisfies the Basic and Method Examination A measurement of one of the near-distance test chart                  requirements.
characters shall be made once before initial use, with                        (j) When an outside agency administers the examina-an optical comparator (lOX or greater) or other suitable                  tion and only a pass or fail grade is issued, the Employer instrument, to verify that the height of a representative                shall assign a grade of 80% for a pass grade.
lower case character, without an ascender or descender                        (g) Level III personnel shall be recertified using the (e.g., a, c, e, 0), for the selected type size, meets the                written Method, Specific, and Practical Examinations requirements of Table IWA-2322-1. This measurement                      and the Demonstration Examination. Alternatively, shall be documented and traceable to the test chart.                    Level III personnel may be recertified using only the written Method and Specific Examinations, provided the following conditions are met:
01 IWA-2323          Level III Personnel                                            ( 1) The Level III candidate was previously certified or recertified using all the written examinations and The qualifications of Level III NDE personnel shall the Demonstration Examination.
be evaluated using written examinations and a Demon-stration Examination. The written examinations shall                                  The Level III candidate is not being recertified service as defined in the 17
 
IWA-2323                                      2001 SECTION XI, DIVISION 1                                    IWA-2420 Practical, and Demonstration examination requirements              (a) Graduate of a 4-year accredited engineering or for Level III NDE personneL                                    science college or university with a degree in engi-neering or science, plus I year experience in NDE in an assignment comparable to that of a Level II in the IWA-2330      LEVEL I RESPONSIBILITIES examination method.
Level I personnel shall use written procedures when              (b) Completion with a passing grade of at least the performing specific setups, calibrations, and examina-          equivalent of 2 full years of engineering or science tions and when recording data, These activities shall            study at a university, college, or technical school, plus be conducted under the guidance of Level II or Level            2 years experience in an assignment comparable to that III personnel. Level I personnel shall not evaluate or           of a Level II in the examination method.
accept the results of a nondestructive examination,                  (c) Four years experience in an assignment compara-ble to that of a Level II in the examination method.
IWA*2340      LEVEL III EDUCATION Level III candidates shall have high school or equiva-      IWA*2380 NDE INSTRUCTOR                                    A02 lent education,                                                    In lieu of the requirements of CP-189, a candidate being considered for qualification as an NDE Instructor IWA-2350        LIMITED CERTIFICATION                            shall satisfy the Level III Basic and Method Examination requirements of IWA-2323 and shall meet one of the Limited certification in a method is permitted for person-  following requirements:
nel who are restricted to performing examinations of lim-            (a) maintain a current teacher or vocational instruc-ited scope, i.e., limited operations or limited techniques      tion certificate issued by a state, municipal, provincial, within the method. Topics that are not relevant to the lim-      or federal authority; or ited certification may be deleted from the ANSI! ASNT                (b) complete a minimum of 40 hr instruction in CP-189, Appendix VI, or Appendix VII training outline            training and teaching techniques.
and may be accompanied by a corresponding reduction in training hours, examination content, and number of exami-nation questions. Only questions related to the limited          IW A*2400 INSPECTION PROGRAM training are required. In addition, the required experience    IWA-2410 APPLICA TION OF CODE EDITION may be reduced by a corresponding amount. The specific                          AND ADDENDA methods and techniques covered by limited certification and the training, examination, and experience require-              The Code Edition and Addenda for preservice inspec-ments for limited certification shall be defined in the writ-    tion and for initial and successive inservice inspection ten practice and documented in the individual's certifica-      intervals shall be in accordance with 10CFR50, Section tion records.                                                    50.55a.
IW A*2360      LEVEL I AND LEVEL II                            IWA-2420        INSPECTION PLANS AND TRAINING AND EXPERIENCE                                          SCHEDULES A candidate may be qualified directly to Level              Inspection plans and schedules shall be prepared for II with no time as a Level [                    the            the preservice inspection, the first inservice inspection and                                  intervals.
 
IWA-2420                                    GENERAL REQUIREMENTS                                            IWA-2430
( 1) identification of the components selected for          (2) That portion of an inspection interval described examination and test, including successive exams from      as an inspection period may be reduced or extended prior periods;                                              by as much as 1 year to enable an inspection to (2) the Code requirements by examination category    coincide with a plant outage. This adjustment shall not and item number for each component and the examina-        alter the rules and requirements for scheduling inspec-tion or test to be performed and the extent of the          tion intervals.
examination or test;                                            (d) For components inspected under Program B, the (3) identification of drawings showing items that    following shall apply:
require examination;                                              ( 1) Each inspection interval may be reduced or (4) list of examination procedures;                  extended by as much as one year. Adjustments shall (5) description of alternative examinations and      not cause successive intervals to be altered by more identification of components to be examined using          than one year from the original pattern of intervals. If alternative methods;                                      an inspection interval is extended, neither the start and end dates nor the in service inspection program for the (6) identification of calibration blocks used for successive interval need be revised.
ultrasonic examination of components.
(2) Examinations may be performed to satisfy the requirements of the extended interval in conjunction IWA*2425        INSPECTION PLAN AND                        with examinations performed to satisfy the requirements SCHEDULE SUPPORTING                        of the successive interval. However, an examination DOCUMENTS                                performed to satisfy requirements of either the extended interval or the successive interval shall not be credited Supporting documents necessary for inspection plan to both intervals.
and schedule implementation such as diagrams or system drawings showing boundaries and system classifications,           (3) That portion of an inspection interval described procedures, specifications, and other documents required  as an inspection period may be reduced or extended for implementation of the inservice examinations and      by as much as one year to enable an inspection to tests shall be available at the plant site.                coincide with a plant outage. This adjustment shall not alter the requirements for scheduling inspection intervals.
(4) The inspection interval for which an examina-IWA*2430          INSPECTION INTERVALS tion was performed shall be identified on examination (a) The inservice examinations and system pressure    records.
tests required by IWB, IWC, IWD, IWE, and inservice              (e) In addition to IWA-2430(c) and (d), for plants examinations and tests of IWF shall be completed            that are out of service continuously for 6 months or during each of the inspection intervals for the service    more, the inspection interval during which the outage lifetime of the plant. The inspections shall be performed  occurred may be extended for a period equivalent to in accordance with the schedule of Inspection Program      the outage and the original pattern of intervals extended A of IWA-2431, or optionally, Inspection Program B          accordingly for successive intervals.
of rw A-2432. It is not required that the inspection            (j) The inspection intervals for items installed by intervals of IWB, IWC, IWD, IWE, and IWF conform            repair !replacement activities shall coincide with re-to the same inspection program.                                                  as determined by the calendar years
 
IWA-2431                                    2001 SECTION XI, DIVISION 1                                  IWA-2641 IWA-2431      Inspection Program A                          IW A-2S00 EXTENT OF EXAMINATION The inspection intervals shall comply with the follow-      Requirements for examination of welds apply only ing, except as may be modified by IW A-2430(c):              to welds joining items and not welds correcting flaws in 1st Inspection Interval - 3 years following initial start    base material (including core closure welds in casting),
of plant commercial service                              unless otherwise stated.
2nd Inspection Interval - 7 years following the 1st inspection interval 3rd Inspection Interval - 13 years following the 2nd          IWA-2600 WELD REFERENCE SYSTEM inspection interval 4th Inspection Interval - 17 years following the 3rd          IWA-2610 GENERAL inspection interval                                          A reference system shall be established for all welds Successive Inspection Intervals - follow IW A-2432            and areas subject to surface or volumetric examination.
Each such weld and area shall be located and identified by a system of reference points. The system shall IWA-2432        Inspection Program B                          permit identification of each weld, location of each The inspection intervals shall comply with the follow-    weld centerline, and designation of regular intervals ing, except as modified by IWA-2430(d):                      along the length of the weld.
i sf Inspection Interval - 10 years following initial start of plant commercial service Successive Inspection intervals - 10 years following        IWA-2620 PIPING the previous inspection interval Requirements for piping are provided in III-4300.
The rules of I1I-4300 may also be applied to piping not within the scope of III-II 00.
IWA-2440 APPLICATION OF CODE CASES IWA-2441 Section XI Code Cases IWA-2630 VESSELS (a) Code Cases to be used during a pre service or inservice inspection shall be identified in the Inspec-          The requirements of Appendix A of Article 4 are tion Plan.                                                    acceptable for vessels examined in accordance with (b) Code Cases shall be applicable to the Edition        Article 4 of Section V.
and Addenda specified in the Inspection Plan.
(c) Code Cases shall be in effect at the time the Inspection Plan is filed with the regulatory and enforce-    IWA-2640 OTHER COMPONENTS ment authorities having jurisdiction at the plant site          A reference system for component welds is given except as provided in IWA-244 I (d).                          in IWA-2641. A different system may be used provided (d) Code Cases issued subsequent to filing the Inspec-    it meets the requirements of IW A-261O.
tion Plan may be proposed for use in amendments to the Inspection Plan.
Code Cases approved                    IWA-2641      Layout of Component Reference continue                Points


IWA-2232 GENERAL REQUIREMENTS IWA-2311 IWA-2232 Ultrasonic Examination Ultrasonic examination shall be conducted in ance with Appendix I. IW A-2233 Eddy Current Examination Eddy current examination shall be conducted in accordance with Section V, Article 8, Appendix II. IWA-2234 Acoustic Emission Examination Acoustic emission may be used in lieu of the sive inspections of IWB-2420(b) or IWC-2420(b) to monitor growth of flaws detected by other NDE ods. The flaws shall be sized by ultrasonic examination in accordance with Appendix I, Supplement 12, prior to initiating use of acoustic emission.
IWA-2641                                    GENERAL REQUIREMENTS                                     IWA-2641 the top of the component. The examination surfaces        of the weld centerline. Zero deg point on the weld shall be identified as above or below the weld.         shall be the top of the nozzle. The 0 deg point for (b) Longitudinal (Vertical) Welds. Longitudinal welds welds of nozzles centered in heads shaH be located at shall be laid out from the center line of circumferential the a deg axis of the vessel. Angular layout of the welds at the top end of the weld. The examination        weld shall be made clockwise on the external surface, surface shaH be identified as clockwise or counterclock-  counterclockwise on the internal surface. Zero, 90, 180, wise as viewed from the top of the component.            and 270 deg lines shall be marked on all nozzle welds (c) Nozzle-fa-Vessel Welds. The external reference    examined; 30 deg increment lines shall be marked on circle shall have a sufficient whole number of inches    nozzle welds greater than 4 in. (102 mm) radius; 15 radius so that the circle falls on the vessel external    deg increment lines shall be marked on nozzle welds surface beyond the weld fillet. The internal reference    greater than 12 in. (305 mm) radius; 5 deg increment circle shall have a sufficient whole number of inches    lines shall be marked on nozzle welds greater than 24 radius so that the circle falls within 1;2 in. (13 mm)    in. (610 mm) radius.}}
Acoustic emission monitoring shall be initiated prior to resuming operation of the system. Acoustic emission shall be conducted in accordance with Section V, Article 13, with the following additional requirements. (a) The following flaw growth calculation and ance criteria shall be used. ( 1) Every two months during the current inspection period, calculate the flaw growth in accordance with Section V, Article 13, Appendix I. Using this growth rate, predict the flaw size at the end of the current inspection period. (2) If the calculated flaw size at the end of the current inspection period meets the acceptance criteria of IWB-3600 or IWC-3600, as applicable, continue the two-month monitoring process described in (1) above. (3) If the calculated flaw size at the end of the current inspection period does not meet the acceptance criteria of IWB-3600 or IWC-3600, as applicable, the following actions shall be performed.
Calculate the flaw size at the end of the next two-month time span. If this calculated flaw size to the original schedule of successive inspections of IWB-2410 or IWC-2410, as applicable.
IW A-2240 ALTERNA TIVE EXAMINATIONS A02 Alternative examination methods, a combination of methods, or newly developed techniques may be tuted for the methods specified in the Construction Code or this Division, provided the Inspector is satisfied that the results are demonstrated to be equivalent or superior to those of the specified method. IWA-2300 QUALIFICATIONS OF NONDESTRUCTIVE EXAMINATION PERSONNEL IW A-2310 GENERAL (a) Personnel performing nondestructive tions (NDE) shall be qualified and certified using a written practice prepared in accordance with ANSI! ASNT CP-189, Standard for Qualification and Certification of Nondestructive Testing Personnel, as amended by the requirements of this Division.
tions based on SNT-TC-IA, ANSI N4S.2.6, or earlier editions of ANSI! ASNT CP-189 are valid until fication is required.
Recertification shall be in ance with the edition of ANSI! ASNT CP-189 referenced in IW A-1600 as amended by the requirements of this Division.
Outside agencies, as defined in Appendix VII, may be used to qualify NDE personnel; however, the Employer shall be solely responsible for the certification of Levels I, II, and III personnel.
Nondestructive and visual examination personnel qualified and certified in accordance with the requirements of this Division are qualified and certified to perform examinations in cordance with the requirements of previous Editions and Addenda.
IWA-2312 2001 SECTION XI, DIVISION 1 IWA-2321 IW A-2312 NDE Methods Listed in ANSI! ASNT CP-189 (a) Qualifications shall be based on the methods, techniques, procedures, and equipment used for the NDE required by this Division. (b) Training, qualification, and certification of sonic examination personnel shall also comply with the requirements of Appendix VII. (c) Training, qualification, and certification of visual examination personnel shall comply with the ments of Appendix VI. (d) The visual examination training and experience hours specified in CP-189 shall be applied to the combined certification of an individual for VT-l, VT-2, and VT-3 visual examination.
Certification in only one of the VT techniques is a limited certification, and the requirements of IW A-2350 apply. IW A-2313 NDE Methods Not Listed in ANSI! ASNT CP-189 Personnel using NDE methods not addressed in ANSI/ASNT CP-189 shall be qualified as defined in ANSI! ASNT CP-189 or the ACCP and the Employer's written practice.
IWA-2314 Certification and Recertification (a) Personnel shall be qualified by examination and shall be certified in accordance with ANSII ASNT CP-189, except that the ASNT Level III certificate is not required.
Levels I, II, and III personnel shall be fied by qualification examinations every 5 years. (b) Personnel qualified in accordance with the ACCP shall be recertified by examination every 5 years. (c) An ACCP certificate with current endorsements obtained by examination satisfies the General and tice Examination requirements for Levels I and II NDE personnel.
IWA-2316 Alternative Qualifications of VT-2 Visual Examination Personnel (a) In lieu of the requirements of IWA-231O through IWA-2314, VT-2 visual examination personnel may be qualified by satisfying the following requirements: ( I) at least 40 hr plant walkdown experience, such as that gained by licensed and nonlicensed operators, local leak rate personnel, system engineers, quality control personnel, and nondestructive examination sonnel (2) at least 4 hr of training in the Section XI requirements and plant-specific procedures for VT-2 visual examination (3) the vision test requirements of IWA-2321 (b) These alternative qualification requirements shall be described in the Employer's written practice.
IWA-2317 Alternative Qualifications of VT-3 Visual Examination Personnel (a) In lieu of the requirements of IW A-231O through IWA-2314, VT-3 visual examination personnel may be qualified by satisfying the following requirements: ( I) at least 40 hours plant experience, such as that gained by plant personnel involved in installation, maintenance, or examination of pumps, valves, and supports, quality control personnel, and nondestructive examination personnel (2) at least 8 hr of training in the Section XI requirements and plant-specific procedures for VT-3 visual examination (3) the vision test requirements of IWA-2321 ( b) The alternative qualification requirements shall be described in the Employer's written practice.
IW A-2320 QUALIFICA TION EXAMINATIONS IWA-2321 Vision Tests be administered 01 IWA-2321 GENERAL REQUIREMENTS IWA-2323 TABLE IWA-2322-1 NEAR-DISTANCE ACUITY TEST DISTANCES AND CHARACTER HEIGHTS Test Distance, in. (mm) 12 (05) 13 (30) 14 (56) 15 (81) 16 (406) Maximum Lower Case Character Height, in. (mm) 0.022 (0.56) 0.024 (0.61) 0.025 (0.63) 0.027 (0.68) 0.029 (0.73) NOTE: The test distances (eye to chart) and corresponding character heights provide a visual angle of 6.25 minutes, which is equivalent to a Snellen fraction of 20/25. ( b) Personnel shall demonstrate the capability to tinguish the colors applicable to the NDE methods for which certified and to differentiate contrast between these colors. IW A-2322 Near-Distance Test Chart Qualification A measurement of one of the near-distance test chart characters shall be made once before initial use, with an optical comparator (lOX or greater) or other suitable instrument, to verify that the height of a representative lower case character, without an ascender or descender (e.g., a, c, e, 0), for the selected type size, meets the requirements of Table IWA-2322-1.
This measurement shall be documented and traceable to the test chart. IWA-2323 Level III Personnel The qualifications of Level III NDE personnel shall be evaluated using written examinations and a stration Examination.
The written examinations shall 17 (3) At least fifteen (IS) questions that are similar to published Level II questions for other NDT methods. (b) The Method Examination shall consist of at least 65 questions: ( 1) At least thirty (30) questions related to mentals and principles that are similar to published ASNT Level III questions for each method. (2) At least fifteen (15) questions related to tion and establishment of procedures and techniques that are similar to published ASNT Level III questions for each method. (3) At least twenty (20) questions related to bility for interpreting codes, standards, and specifications related to the method. (e) The Specific Examination shall contain at least 30 questions covering equipment, techniques, dures, and administration of the Employer's written practice.
The Specific Examination shall also cover the NDE requirements of this Division, including acceptance standards and referenced codes and standards. (d) The Practical Examination shall be in accordance with ANSI/ASNT CP-189 requirements. (e) An ASNT Level III certificate with current dorsements obtained by examination for the applicable method satisfies the Basic and Method Examination requirements. (j) When an outside agency administers the tion and only a pass or fail grade is issued, the Employer shall assign a grade of 80% for a pass grade. (g) Level III personnel shall be recertified using the written Method, Specific, and Practical Examinations and the Demonstration Examination.
Alternatively, Level III personnel may be recertified using only the written Method and Specific Examinations, provided the following conditions are met: ( 1) The Level III candidate was previously certified or recertified using all the written examinations and the Demonstration Examination.
The Level III candidate is not being recertified service as defined in the IWA-2323 2001 SECTION XI, DIVISION 1 IWA-2420 Practical, and Demonstration examination requirements for Level III NDE personneL IWA-2330 LEVEL I RESPONSIBILITIES Level I personnel shall use written procedures when performing specific setups, calibrations, and tions and when recording data, These activities shall be conducted under the guidance of Level II or Level III personnel.
Level I personnel shall not evaluate or accept the results of a nondestructive examination, IWA*2340 LEVEL III EDUCATION Level III candidates shall have high school or lent education, IWA-2350 LIMITED CERTIFICATION Limited certification in a method is permitted for nel who are restricted to performing examinations of ited scope, i.e., limited operations or limited techniques within the method. Topics that are not relevant to the ited certification may be deleted from the ANSI! ASNT CP-189, Appendix VI, or Appendix VII training outline and may be accompanied by a corresponding reduction in training hours, examination content, and number of nation questions.
Only questions related to the limited training are required.
In addition, the required experience may be reduced by a corresponding amount. The specific methods and techniques covered by limited certification and the training, examination, and experience ments for limited certification shall be defined in the ten practice and documented in the individual's tion records. IW A*2360 LEVEL I AND LEVEL II TRAINING AND EXPERIENCE A candidate may be qualified directly to Level II with no time as a Level [ the (a) Graduate of a 4-year accredited engineering or science college or university with a degree in neering or science, plus I year experience in NDE in an assignment comparable to that of a Level II in the examination method. (b) Completion with a passing grade of at least the equivalent of 2 full years of engineering or science study at a university, college, or technical school, plus 2 years experience in an assignment comparable to that of a Level II in the examination method. (c) Four years experience in an assignment ble to that of a Level II in the examination method. IWA*2380 NDE INSTRUCTOR A02 In lieu of the requirements of CP-189, a candidate being considered for qualification as an NDE Instructor shall satisfy the Level III Basic and Method Examination requirements of IWA-2323 and shall meet one of the following requirements: (a) maintain a current teacher or vocational tion certificate issued by a state, municipal, provincial, or federal authority; or (b) complete a minimum of 40 hr instruction in training and teaching techniques.
IW A*2400 INSPECTION PROGRAM IW A-2410 APPLICA TION OF CODE EDITION AND ADDENDA The Code Edition and Addenda for preservice tion and for initial and successive inservice inspection intervals shall be in accordance with lOCFR50, Section 50.55a. IWA-2420 INSPECTION PLANS AND SCHEDULES Inspection plans and schedules shall be prepared for the preservice inspection, the first inservice inspection and intervals.
IWA-2420 GENERAL REQUIREMENTS IWA-2430 ( 1) identification of the components selected for examination and test, including successive exams from prior periods; (2) the Code requirements by examination category and item number for each component and the tion or test to be performed and the extent of the examination or test; (3) identification of drawings showing items that require examination; (4) list of examination procedures; (5) description of alternative examinations and identification of components to be examined using alternative methods; (6) identification of calibration blocks used for ultrasonic examination of components.
IWA*2425 INSPECTION PLAN AND SCHEDULE SUPPORTING DOCUMENTS Supporting documents necessary for inspection plan and schedule implementation such as diagrams or system drawings showing boundaries and system classifications, procedures, specifications, and other documents required for implementation of the inservice examinations and tests shall be available at the plant site. IWA*2430 INSPECTION INTERVALS (a) The inservice examinations and system pressure tests required by IWB, IWC, IWD, IWE, and inservice examinations and tests of IWF shall be completed during each of the inspection intervals for the service lifetime of the plant. The inspections shall be performed in accordance with the schedule of Inspection Program A of IWA-2431, or optionally, Inspection Program B of rw A-2432. It is not required that the inspection intervals of IWB, IWC, IWD, IWE, and IWF conform to the same inspection program. (2) That portion of an inspection interval described as an inspection period may be reduced or extended by as much as 1 year to enable an inspection to coincide with a plant outage. This adjustment shall not alter the rules and requirements for scheduling tion intervals. (d) For components inspected under Program B, the following shall apply: ( 1) Each inspection interval may be reduced or extended by as much as one year. Adjustments shall not cause successive intervals to be altered by more than one year from the original pattern of intervals.
If an inspection interval is extended, neither the start and end dates nor the in service inspection program for the successive interval need be revised. (2) Examinations may be performed to satisfy the requirements of the extended interval in conjunction with examinations performed to satisfy the requirements of the successive interval.
However, an examination performed to satisfy requirements of either the extended interval or the successive interval shall not be credited to both intervals.
(3) That portion of an inspection interval described as an inspection period may be reduced or extended by as much as one year to enable an inspection to coincide with a plant outage. This adjustment shall not alter the requirements for scheduling inspection intervals.
(4) The inspection interval for which an tion was performed shall be identified on examination records. (e) In addition to IWA-2430(c) and (d), for plants that are out of service continuously for 6 months or more, the inspection interval during which the outage occurred may be extended for a period equivalent to the outage and the original pattern of intervals extended accordingly for successive intervals. (j) The inspection intervals for items installed by repair !replacement activities shall coincide with as determined by the calendar years IWA-2431 2001 SECTION XI, DIVISION 1 IWA-2641 IWA-2431 Inspection Program A The inspection intervals shall comply with the ing, except as may be modified by IW A-2430(c):
1 st Inspection Interval -3 years following initial start of plant commercial service 2nd Inspection Interval -7 years following the 1st inspection interval 3rd Inspection Interval -13 years following the 2nd inspection interval 4th Inspection Interval -17 years following the 3rd inspection interval Successive Inspection Intervals
-follow IW A-2432 IWA-2432 Inspection Program B The inspection intervals shall comply with the ing, except as modified by IWA-2430(d):
i sf Inspection Interval -10 years following initial start of plant commercial service Successive Inspection intervals
-10 years following the previous inspection interval IWA-2440 APPLICATION OF CODE CASES IWA-2441 Section XI Code Cases (a) Code Cases to be used during a pre service or inservice inspection shall be identified in the tion Plan. (b) Code Cases shall be applicable to the Edition and Addenda specified in the Inspection Plan. (c) Code Cases shall be in effect at the time the Inspection Plan is filed with the regulatory and ment authorities having jurisdiction at the plant site except as provided in IWA-244 I (d). (d) Code Cases issued subsequent to filing the tion Plan may be proposed for use in amendments to the Inspection Plan. Code Cases approved continue IW A-2S00 EXTENT OF EXAMINATION Requirements for examination of welds apply only to welds joining items and not welds correcting flaws in base material (including core closure welds in casting), unless otherwise stated. IWA-2600 WELD REFERENCE SYSTEM IWA-2610 GENERAL A reference system shall be established for all welds and areas subject to surface or volumetric examination.
Each such weld and area shall be located and identified by a system of reference points. The system shall permit identification of each weld, location of each weld centerline, and designation of regular intervals along the length of the weld. IWA-2620 PIPING Requirements for piping are provided in III-4300.
The rules of I1I-4300 may also be applied to piping not within the scope of III-II 00. IWA-2630 VESSELS The requirements of Appendix A of Article 4 are acceptable for vessels examined in accordance with Article 4 of Section V. IWA-2640 OTHER COMPONENTS A reference system for component welds is given in IWA-2641.
A different system may be used provided it meets the requirements of IW A-261O. IW A -2641 Layout of Component Reference Points IWA-2641 GENERAL REQUIREMENTS IWA-2641 the top of the component.
The examination surfaces shall be identified as above or below the weld. (b) Longitudinal (Vertical)
Welds. Longitudinal welds shall be laid out from the center line of circumferential welds at the top end of the weld. The examination surface shaH be identified as clockwise or wise as viewed from the top of the component. (c) Nozzle-fa-Vessel Welds. The external reference circle shall have a sufficient whole number of inches radius so that the circle falls on the vessel external surface beyond the weld fillet. The internal reference circle shall have a sufficient whole number of inches radius so that the circle falls within 1;2 in. (13 mm) of the weld centerline.
Zero deg point on the weld shall be the top of the nozzle. The 0 deg point for welds of nozzles centered in heads shaH be located at the a deg axis of the vessel. Angular layout of the weld shall be made clockwise on the external surface, counterclockwise on the internal surface. Zero, 90, 180, and 270 deg lines shall be marked on all nozzle welds examined; 30 deg increment lines shall be marked on nozzle welds greater than 4 in. (102 mm) radius; 15 deg increment lines shall be marked on nozzle welds greater than 12 in. (305 mm) radius; 5 deg increment lines shall be marked on nozzle welds greater than 24 in. (610 mm) radius.}}

Latest revision as of 00:35, 12 November 2019

Entergy Pre-Filed Hearing Exhibit ENT000531 - ASME Code, Sec. XI, Art. IWA-2000 (2001)
ML12233A701
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 08/20/2012
From:
- No Known Affiliation
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS 23330, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12233A701 (12)


Text

ENT000531 Submitted: August 20, 2012 ARTICLE IWA-2000 EXAMINATION AND INSPECTION IWA-2100 GENERAL the Owner's agent and qualified in accordance with IWA-2300.

A02 IWA-2110 DUTIES OF THE INSPECTOR (h) The Inspector may require, at any time, requalifi-(a) The Inspector shall review the inspection plan cation of any procedure or operator if the Inspector and, as necessary, the implementation schedule (IWA- has reason to believe that the requirements are not 2420) prior to the start of preservice inspection and being met.

each inspection interval. The review shall cover any (i) The Inspector shall certify the examination rec-features that are affected by the requirements of this ords after verifying that the requirements have been Division, as applicable, and shall include the following: met and that the records are correct.

( 1) examination categories and items (j) The Inspector shall verify that repair /replacement (2) test and examination requirements activities are performed in accordance with the require-(3) examination methods ments of the Owner's Repair/Replacement Program.

(k) The Inspector shall review the Repair/Replace-(4) percentage of parts selected for examination ment Program and its implementation.

(5) disposition of test results (6) test frequency (7) system pressure tests (8) sequence of successive examinations IWA-2120 QUALIFICATION OF Shop and field preservice examinations are exempt from AUTHORIZED INSPECTION prior review.

AGENCIES, INSPECTORS, AND (b) The Inspector shall review any revisions to the SUPERVISORS inspection plan and, as necessary, the implementation schedule during the preservice inspection or the inspec- (a) The inspection required by this Division shall tion interval. be performed:

(c) The Inspector shall submit a report to the Owner (1) where the plant is in the United States, by an documenting review of the items identified in IWA- Inspector employed by a State or Municipality of the 211O(a) and (b). United States or an Inspector regularly employed by an insurance company authorized to write boiler and (d) The Inspector shall verify that the required exami-pressure vessel insurance in the United States; nations and system pressure tests have been performed where the plant is in Canada, by an Inspector and the results recorded.

a Canadian Province or, if authorized

IWA*2120 GENERAL REQUIREMENTS IWA*2213 (c) The Authorized Inspection Agency shall be ac- (d) Illumination for examination shall meet the re-credited by AS ME in accordance with the provisions quirements specified in Table IWA-2211-1.

set forth in ASME QAI-l. (e) It is not necessary to measure the illumination level on each examination surface when the same portable nonbattery-powered light source (e.g., drop IWA-2130 ACCESS FOR INSPECTOR light) or similar installed lighting equipment is demon-strated to provide the illumination specified at the The Owner shall arrange for an Inspector to have maximum examination distance.

access to all parts of the plant as necessary to make (f) When a battery-powered light is used, the ade-the required inspections. The Owner shall keep the quacy of the illumination level shall be checked before Inspector informed of the progress of the preparatory and after each examination or series of examinations, work necessary to permit inspections and shall notify not to exceed 4 hr between checks.

the Inspector at a time reasonably in advance of when (g) Remote visual examination may be substituted the components will be ready for inspection. for direct examination. The remote examination proce-dure shall be demonstrated capable of resolving charac-ters in accordance with Table IWA-221l-1. Addition-IWA-2200 EXAMINATION METHODS ally, the remote examination system shall be capable of distinguishing the colors applicable to the component (a) The three types of examinations used during examination being conducted.

inservice inspection are defined as visual, surface, and volumetric. The examination method to be used is specified in Tables IWB-, IWC-, IWD-, IWE-, IWF-, IWA-2212 VT-2 Examination A03 and IWL-2S00-1. If a component must be examined in a high radiation area, remotely controlled equipment (a) VT-2 examination is conducted to detect evidence may be advisable. of leakage from pressure retaining components, with (b) When preparation of a surface for nondestructive or without leakage collection systems, as required during examination is required, the preparation shall be by a the system pressure test.

mechanical method. Such surfaces shall be blended (b) VT-2 examination shall be conducted in accord-into the surrounding area as may be required to perform ance with IWA-SOOO.

the examination. The wall thickness shall not be reduced below the minimum thickness required by design. Non-IWA-2213 VT-3 Examination A03 mandatory Appendix D may be used for such surface preparation. (a) VT-3 examination is conducted to determine the general mechanical and structural condition of compo-nents and their supports by verifying parameters such A02 IWA-2210 VISUAL EXAMINATIONS as clearances, settings, and physical displacements; to A03 detect discontinuities and imperfections, such as loss Visual examinations shall be conducted in accordance of integrity at bolted or welded connections, loose or with Section V, Article 9, T-941 for Written Procedures, missing parts, debris, corrosion, wear, or erosion; and and T-990 for Report of Examination Results. to detect conditions that could affect operability or functional adequacy of snubbers and constant load and

IWA-2213 2001 SECTION XI, DIVISION 1 IWA-2224 A02 TABLE IWA-221l-1 A03 VISUAL EXAMINATIONS Minimum Maximum Height, in. (mm),

Illumination, Maximum Direct for Procedure Visual fc Examination Distance, Demonstration Examination [Note (1)] ft (mm) Characters [Note (2)]

VT-l 50 2 (600) 0.044 n.O)

VT-3 50 N/A 0.105 0.0)

NOTES:

(1) Resolution ofthe specified characters can be used in lieu of illumination measurement to verify illumination adequacy.

(2) For procedure demonstration, a test chart or card containing text with some lowercase characters, without an ascender or descender (e.g., a, c, e, 0), that meet the specified height requirements is required.

Measurements of the test chart or card shall be made once before its initial use with an optical comparator (lax or greater) or other suitable instrument to verify that the height of the lowercase characters without an ascender or descender meets the specified requirements.

light) or similar installed lighting equipment is demon- ( c) Any flaw recorded by ultrasonic examination shall strated to provide the illumination specified in Table be compared to the volumetric examination acceptance IW A -2211-1 at the maximum examination distance. standards of Table IWB-3514-1 or Table IWB-3514-2 (f) Whl~n a battery-powered light is used, the ade- for surface planar flaw.

quacy of the illumination level shall be checked before and after each examination or series of examinations, not to exceed 4 hr between checks.

IWA-2221 Magnetic Particle Examination (g) Remote visual examination may be substituted for direct examination. The remote examination proce- (a) Magnetic particle examination shall be conducted dure shall be demonstrated capable of resolving charac- in accordance with Section V, Article 7.

ters in accordance with Table IWA-2211-1. Addition- ( b) Magnetic particle examination of coated materials ally, the remote visual examination system shall be shall be conducted in accordance with Section V, Article capable of distinguishing the colors applicable to the 7, Appendix I.

component examinations being conducted.

IWA-221S Replication IW A-2222 Liquid Penetrant Examination Surface replication methods may be used for VT-I Liquid penetrant examination shall be conducted in and VT-3 examinations when the surface resolution is accordance with Section V, Article 6.

at least equivalent to that of direct visual observation.

IWA-2223 Eddy Current Examination

IWA*2230 GENERAL REQUIREMENTS IWA*2231 IWA*2230 VOLUMETRIC EXAMINATION neutrons, may be utilized with appropriate image-re-cording devices, such as photographic film or papers, A volumetric examination indicates the presence of electrostatic systems, direct-image orthicons, or image discontinuities throughout the volume of material and converters. For radiographic examinations employing may be conducted from either the inside or outside either X-ray equipment or radioactive isotopes and surface of a component.

photographic films, the procedure shall be as specified in Article 2 of Section V.

IWA-2231 Radiographic Examination Radiographic techniques, employing penetrating radi-ation such as X-rays, gamma rays, or thermalized

IWA-2232 GENERAL REQUIREMENTS IWA-2311 IWA-2232 Ultrasonic Examination to the original schedule of successive inspections of IWB-2410 or IWC-2410, as applicable.

Ultrasonic examination shall be conducted in accord-ance with Appendix I.

IW A-2240 ALTERNA TIVE EXAMINATIONS A02 IWA-2233 Eddy Current Examination Alternative examination methods, a combination of methods, or newly developed techniques may be substi-Eddy current examination shall be conducted in tuted for the methods specified in the Construction accordance with Section V, Article 8, Appendix II. Code or this Division, provided the Inspector is satisfied that the results are demonstrated to be equivalent or superior to those of the specified method.

IWA-2234 Acoustic Emission Examination Acoustic emission may be used in lieu of the succes-sive inspections of IWB-2420(b) or IWC-2420(b) to IWA-2300 QUALIFICATIONS OF monitor growth of flaws detected by other NDE meth- NONDESTRUCTIVE ods. The flaws shall be sized by ultrasonic examination EXAMINATION PERSONNEL in accordance with Appendix I, Supplement 12, prior IW A-2310 GENERAL to initiating use of acoustic emission. Acoustic emission monitoring shall be initiated prior to resuming operation (a) Personnel performing nondestructive examina-of the system. Acoustic emission shall be conducted tions (NDE) shall be qualified and certified using a in accordance with Section V, Article 13, with the written practice prepared in accordance with following additional requirements. ANSI! ASNT CP-189, Standard for Qualification and (a) The following flaw growth calculation and accept- Certification of Nondestructive Testing Personnel, as ance criteria shall be used. amended by the requirements of this Division. Certifica-( 1) Every two months during the current inspection tions based on SNT-TC-IA, ANSI N4S.2.6, or earlier period, calculate the flaw growth in accordance with editions of ANSI! ASNT CP-189 are valid until recerti-Section V, Article 13, Appendix I. Using this growth fication is required. Recertification shall be in accord-rate, predict the flaw size at the end of the current ance with the edition of ANSI! ASNT CP-189 referenced inspection period. in IW A-1600 as amended by the requirements of this (2) If the calculated flaw size at the end of the Division. Outside agencies, as defined in Appendix VII, current inspection period meets the acceptance criteria may be used to qualify NDE personnel; however, the of IWB-3600 or IWC-3600, as applicable, continue the Employer shall be solely responsible for the certification two-month monitoring process described in (1) above. of Levels I, II, and III personnel. Nondestructive and visual examination personnel qualified and certified in (3) If the calculated flaw size at the end of the accordance with the requirements of this Division are current inspection period does not meet the acceptance qualified and certified to perform examinations in ac-criteria of IWB-3600 or IWC-3600, as applicable, the cordance with the requirements of previous Editions following actions shall be performed.

and Addenda.

Calculate the flaw size at the end of the next two-month time span. If this calculated flaw size

IWA-2312 2001 SECTION XI, DIVISION 1 IWA-2321 IW A-2312 NDE Methods Listed in ANSI! ASNT IWA-2316 Alternative Qualifications of VT-2 CP-189 Visual Examination Personnel (a) Qualifications shall be based on the methods, (a) In lieu of the requirements of IWA-231O through techniques, procedures, and equipment used for the IWA-2314, VT-2 visual examination personnel may be NDE required by this Division. qualified by satisfying the following requirements:

(b) Training, qualification, and certification of ultra- ( I) at least 40 hr plant walkdown experience, such sonic examination personnel shall also comply with as that gained by licensed and nonlicensed operators, the requirements of Appendix VII. local leak rate personnel, system engineers, quality (c) Training, qualification, and certification of visual control personnel, and nondestructive examination per-examination personnel shall comply with the require- sonnel ments of Appendix VI. (2) at least 4 hr of training in the Section XI (d) The visual examination training and experience requirements and plant-specific procedures for VT-2 hours specified in CP-189 shall be applied to the visual examination combined certification of an individual for VT-l, VT- (3) the vision test requirements of IWA-2321 2, and VT-3 visual examination. Certification in only (b) These alternative qualification requirements shall one of the VT techniques is a limited certification, and be described in the Employer's written practice.

the requirements of IW A-2350 apply.

IWA-2317 Alternative Qualifications of VT-3 IW A-2313 NDE Methods Not Listed in Visual Examination Personnel ANSI! ASNT CP-189 (a) In lieu of the requirements of IWA-231O through Personnel using NDE methods not addressed in IWA-2314, VT-3 visual examination personnel may be ANSI/ASNT CP-189 shall be qualified as defined in qualified by satisfying the following requirements:

ANSI! ASNT CP-189 or the ACCP and the Employer's ( I) at least 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> plant experience, such as written practice. that gained by plant personnel involved in installation, maintenance, or examination of pumps, valves, and supports, quality control personnel, and nondestructive IWA-2314 Certification and Recertification examination personnel (a) Personnel shall be qualified by examination and (2) at least 8 hr of training in the Section XI shall be certified in accordance with ANSII ASNT CP- requirements and plant-specific procedures for VT-3 189, except that the ASNT Level III certificate is not visual examination required. Levels I, II, and III personnel shall be recerti- (3) the vision test requirements of IWA-2321 fied by qualification examinations every 5 years. ( b) The alternative qualification requirements shall (b) Personnel qualified in accordance with the ACCP be described in the Employer's written practice.

shall be recertified by examination every 5 years.

(c) An ACCP certificate with current endorsements obtained by examination satisfies the General and Prac- IW A-2320 QUALIFICA TION EXAMINATIONS tice Examination requirements for Levels I and II NDE personnel. IWA-2321 Vision Tests be administered

IWA-2321 GENERAL REQUIREMENTS IWA-2323 TABLE IWA-2322-1 (3) At least fifteen (IS) questions that are similar NEAR-DISTANCE ACUITY TEST DISTANCES to published Level II questions for other NDT methods.

AND CHARACTER HEIGHTS (b) The Method Examination shall consist of at least Maximum Lower Case 65 questions:

Test Distance, Character Height,

( 1) At least thirty (30) questions related to funda-in. (mm) in. (mm) mentals and principles that are similar to published 12 (05) 0.022 (0.56) ASNT Level III questions for each method.

13 (30) 0.024 (0.61)

(2) At least fifteen (15) questions related to applica-14 (56) 0.025 (0.63) 15 (81) 0.027 (0.68) tion and establishment of procedures and techniques 16 (406) 0.029 (0.73) that are similar to published ASNT Level III questions for each method.

NOTE: The test distances (eye to chart) and corresponding character (3) At least twenty (20) questions related to capa-heights provide a visual angle of 6.25 minutes, which is equivalent to a Snellen fraction of 20/25. bility for interpreting codes, standards, and specifications related to the method.

(e) The Specific Examination shall contain at least 30 questions covering equipment, techniques, proce-dures, and administration of the Employer's written

( b) Personnel shall demonstrate the capability to dis- practice. The Specific Examination shall also cover the tinguish the colors applicable to the NDE methods for NDE requirements of this Division, including acceptance which certified and to differentiate contrast between standards and referenced codes and standards.

these colors. (d) The Practical Examination shall be in accordance with ANSI/ASNT CP-189 requirements.

(e) An ASNT Level III certificate with current en-IWA-2322 Near-Distance Test Chart dorsements obtained by examination for the applicable Qualification method satisfies the Basic and Method Examination A measurement of one of the near-distance test chart requirements.

characters shall be made once before initial use, with (j) When an outside agency administers the examina-an optical comparator (lOX or greater) or other suitable tion and only a pass or fail grade is issued, the Employer instrument, to verify that the height of a representative shall assign a grade of 80% for a pass grade.

lower case character, without an ascender or descender (g) Level III personnel shall be recertified using the (e.g., a, c, e, 0), for the selected type size, meets the written Method, Specific, and Practical Examinations requirements of Table IWA-2322-1. This measurement and the Demonstration Examination. Alternatively, shall be documented and traceable to the test chart. Level III personnel may be recertified using only the written Method and Specific Examinations, provided the following conditions are met:

01 IWA-2323 Level III Personnel ( 1) The Level III candidate was previously certified or recertified using all the written examinations and The qualifications of Level III NDE personnel shall the Demonstration Examination.

be evaluated using written examinations and a Demon-stration Examination. The written examinations shall The Level III candidate is not being recertified service as defined in the 17

IWA-2323 2001 SECTION XI, DIVISION 1 IWA-2420 Practical, and Demonstration examination requirements (a) Graduate of a 4-year accredited engineering or for Level III NDE personneL science college or university with a degree in engi-neering or science, plus I year experience in NDE in an assignment comparable to that of a Level II in the IWA-2330 LEVEL I RESPONSIBILITIES examination method.

Level I personnel shall use written procedures when (b) Completion with a passing grade of at least the performing specific setups, calibrations, and examina- equivalent of 2 full years of engineering or science tions and when recording data, These activities shall study at a university, college, or technical school, plus be conducted under the guidance of Level II or Level 2 years experience in an assignment comparable to that III personnel. Level I personnel shall not evaluate or of a Level II in the examination method.

accept the results of a nondestructive examination, (c) Four years experience in an assignment compara-ble to that of a Level II in the examination method.

IWA*2340 LEVEL III EDUCATION Level III candidates shall have high school or equiva- IWA*2380 NDE INSTRUCTOR A02 lent education, In lieu of the requirements of CP-189, a candidate being considered for qualification as an NDE Instructor IWA-2350 LIMITED CERTIFICATION shall satisfy the Level III Basic and Method Examination requirements of IWA-2323 and shall meet one of the Limited certification in a method is permitted for person- following requirements:

nel who are restricted to performing examinations of lim- (a) maintain a current teacher or vocational instruc-ited scope, i.e., limited operations or limited techniques tion certificate issued by a state, municipal, provincial, within the method. Topics that are not relevant to the lim- or federal authority; or ited certification may be deleted from the ANSI! ASNT (b) complete a minimum of 40 hr instruction in CP-189, Appendix VI, or Appendix VII training outline training and teaching techniques.

and may be accompanied by a corresponding reduction in training hours, examination content, and number of exami-nation questions. Only questions related to the limited IW A*2400 INSPECTION PROGRAM training are required. In addition, the required experience IWA-2410 APPLICA TION OF CODE EDITION may be reduced by a corresponding amount. The specific AND ADDENDA methods and techniques covered by limited certification and the training, examination, and experience require- The Code Edition and Addenda for preservice inspec-ments for limited certification shall be defined in the writ- tion and for initial and successive inservice inspection ten practice and documented in the individual's certifica- intervals shall be in accordance with 10CFR50, Section tion records. 50.55a.

IW A*2360 LEVEL I AND LEVEL II IWA-2420 INSPECTION PLANS AND TRAINING AND EXPERIENCE SCHEDULES A candidate may be qualified directly to Level Inspection plans and schedules shall be prepared for II with no time as a Level [ the the preservice inspection, the first inservice inspection and intervals.

IWA-2420 GENERAL REQUIREMENTS IWA-2430

( 1) identification of the components selected for (2) That portion of an inspection interval described examination and test, including successive exams from as an inspection period may be reduced or extended prior periods; by as much as 1 year to enable an inspection to (2) the Code requirements by examination category coincide with a plant outage. This adjustment shall not and item number for each component and the examina- alter the rules and requirements for scheduling inspec-tion or test to be performed and the extent of the tion intervals.

examination or test; (d) For components inspected under Program B, the (3) identification of drawings showing items that following shall apply:

require examination; ( 1) Each inspection interval may be reduced or (4) list of examination procedures; extended by as much as one year. Adjustments shall (5) description of alternative examinations and not cause successive intervals to be altered by more identification of components to be examined using than one year from the original pattern of intervals. If alternative methods; an inspection interval is extended, neither the start and end dates nor the in service inspection program for the (6) identification of calibration blocks used for successive interval need be revised.

ultrasonic examination of components.

(2) Examinations may be performed to satisfy the requirements of the extended interval in conjunction IWA*2425 INSPECTION PLAN AND with examinations performed to satisfy the requirements SCHEDULE SUPPORTING of the successive interval. However, an examination DOCUMENTS performed to satisfy requirements of either the extended interval or the successive interval shall not be credited Supporting documents necessary for inspection plan to both intervals.

and schedule implementation such as diagrams or system drawings showing boundaries and system classifications, (3) That portion of an inspection interval described procedures, specifications, and other documents required as an inspection period may be reduced or extended for implementation of the inservice examinations and by as much as one year to enable an inspection to tests shall be available at the plant site. coincide with a plant outage. This adjustment shall not alter the requirements for scheduling inspection intervals.

(4) The inspection interval for which an examina-IWA*2430 INSPECTION INTERVALS tion was performed shall be identified on examination (a) The inservice examinations and system pressure records.

tests required by IWB, IWC, IWD, IWE, and inservice (e) In addition to IWA-2430(c) and (d), for plants examinations and tests of IWF shall be completed that are out of service continuously for 6 months or during each of the inspection intervals for the service more, the inspection interval during which the outage lifetime of the plant. The inspections shall be performed occurred may be extended for a period equivalent to in accordance with the schedule of Inspection Program the outage and the original pattern of intervals extended A of IWA-2431, or optionally, Inspection Program B accordingly for successive intervals.

of rw A-2432. It is not required that the inspection (j) The inspection intervals for items installed by intervals of IWB, IWC, IWD, IWE, and IWF conform repair !replacement activities shall coincide with re-to the same inspection program. as determined by the calendar years

IWA-2431 2001 SECTION XI, DIVISION 1 IWA-2641 IWA-2431 Inspection Program A IW A-2S00 EXTENT OF EXAMINATION The inspection intervals shall comply with the follow- Requirements for examination of welds apply only ing, except as may be modified by IW A-2430(c): to welds joining items and not welds correcting flaws in 1st Inspection Interval - 3 years following initial start base material (including core closure welds in casting),

of plant commercial service unless otherwise stated.

2nd Inspection Interval - 7 years following the 1st inspection interval 3rd Inspection Interval - 13 years following the 2nd IWA-2600 WELD REFERENCE SYSTEM inspection interval 4th Inspection Interval - 17 years following the 3rd IWA-2610 GENERAL inspection interval A reference system shall be established for all welds Successive Inspection Intervals - follow IW A-2432 and areas subject to surface or volumetric examination.

Each such weld and area shall be located and identified by a system of reference points. The system shall IWA-2432 Inspection Program B permit identification of each weld, location of each The inspection intervals shall comply with the follow- weld centerline, and designation of regular intervals ing, except as modified by IWA-2430(d): along the length of the weld.

i sf Inspection Interval - 10 years following initial start of plant commercial service Successive Inspection intervals - 10 years following IWA-2620 PIPING the previous inspection interval Requirements for piping are provided in III-4300.

The rules of I1I-4300 may also be applied to piping not within the scope of III-II 00.

IWA-2440 APPLICATION OF CODE CASES IWA-2441 Section XI Code Cases IWA-2630 VESSELS (a) Code Cases to be used during a pre service or inservice inspection shall be identified in the Inspec- The requirements of Appendix A of Article 4 are tion Plan. acceptable for vessels examined in accordance with (b) Code Cases shall be applicable to the Edition Article 4 of Section V.

and Addenda specified in the Inspection Plan.

(c) Code Cases shall be in effect at the time the Inspection Plan is filed with the regulatory and enforce- IWA-2640 OTHER COMPONENTS ment authorities having jurisdiction at the plant site A reference system for component welds is given except as provided in IWA-244 I (d). in IWA-2641. A different system may be used provided (d) Code Cases issued subsequent to filing the Inspec- it meets the requirements of IW A-261O.

tion Plan may be proposed for use in amendments to the Inspection Plan.

Code Cases approved IWA-2641 Layout of Component Reference continue Points

IWA-2641 GENERAL REQUIREMENTS IWA-2641 the top of the component. The examination surfaces of the weld centerline. Zero deg point on the weld shall be identified as above or below the weld. shall be the top of the nozzle. The 0 deg point for (b) Longitudinal (Vertical) Welds. Longitudinal welds welds of nozzles centered in heads shaH be located at shall be laid out from the center line of circumferential the a deg axis of the vessel. Angular layout of the welds at the top end of the weld. The examination weld shall be made clockwise on the external surface, surface shaH be identified as clockwise or counterclock- counterclockwise on the internal surface. Zero, 90, 180, wise as viewed from the top of the component. and 270 deg lines shall be marked on all nozzle welds (c) Nozzle-fa-Vessel Welds. The external reference examined; 30 deg increment lines shall be marked on circle shall have a sufficient whole number of inches nozzle welds greater than 4 in. (102 mm) radius; 15 radius so that the circle falls on the vessel external deg increment lines shall be marked on nozzle welds surface beyond the weld fillet. The internal reference greater than 12 in. (305 mm) radius; 5 deg increment circle shall have a sufficient whole number of inches lines shall be marked on nozzle welds greater than 24 radius so that the circle falls within 1;2 in. (13 mm) in. (610 mm) radius.