Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- L-88-434, Forwards Response to Violations Noted in Insp Repts 50-250/88-20 & 50-251/88-20.Encl Withheld (Ref 10CFR2.790 & 73.21) + (16:41:22, 7 January 2025)
- ML17345A442 + (16:41:32, 7 January 2025)
- ML17345A441 + (16:41:34, 7 January 2025)
- ML17345A439 + (16:41:36, 7 January 2025)
- L-88-433, Responds to Violations Noted in Insp Repts 50-250/88-18 & 50-251/88-18.Corrective Actions:Operators Counselled Re Issue of Inadequate Review of Operator Logs & Shift Info Book Entry Made to Have Issue Discussed at Meetings + (16:41:38, 7 January 2025)
- ML17345A438 + (16:41:38, 7 January 2025)
- ML17345A436 + (16:41:42, 7 January 2025)
- ML17345A435 + (16:41:43, 7 January 2025)
- ML17345A433 + (16:41:44, 7 January 2025)
- ML17345A432 + (16:41:45, 7 January 2025)
- L-88-389, Application for Amends to Licenses DPR-31 & DPR-41,modifying Section 3.0 & 4.0 of Tech Specs Per Generic Ltr 87-09 Re Applicability of Limiting Conditions for Operation & Surveillance Requirements.Fee Paid + (16:41:46, 7 January 2025)
- 05000250/LER-1988-020, :on 880831,control Room Ventilation Sys Shifted to Recirculation Mode While Conducting Routine Test of Channel B Air Intake Radiation Monitor.Caused by Spurious Actuation Signal.Recirculation Mode Verified + (16:41:52, 7 January 2025)
- L-88-406, Forwards mgt-on-shift Weekly Rept for Wk Starting 880902 + (16:41:55, 7 January 2025)
- IR 05000250/1988014 + (16:41:58, 7 January 2025)
- ML17345A422 + (16:42:00, 7 January 2025)
- ML17345A424 + (16:42:00, 7 January 2025)
- ML17345A420 + (16:42:01, 7 January 2025)
- L-88-424, Application for Amends to Licenses DPR-31 & DPR-41, Incorporating Revised Heatup & Cooldown Limit Curves Applicable Up to 20 EFPYs of Svc Life.Westinghouse Ltr Rept MT/SMART/116(88) Encl.Fee Paid + (16:42:02, 7 January 2025)
- 05000250/LER-1988-018-06, :on 880822,determined That Refueling Water Storage Tank Supply to ECCS Isolated from Both Trains of ECCS Sys.Caused by Procedure Inadequacy.Procedure Revised to Exclude Monthly Cycling of Tank Outlet Valves + (16:42:05, 7 January 2025)
- ML17345A415 + (16:42:07, 7 January 2025)
- ML17345A413 + (16:42:08, 7 January 2025)
- ML17345A412 + (16:42:10, 7 January 2025)
- ML17345A410 + (16:42:11, 7 January 2025)
- L-88-394, Forwards Mgt on Shift Weekly Repts for Wk Starting 880826. Plant Supervisor Nuclear Shift Repts Also Being Submitted + (16:42:12, 7 January 2025)
- L-88-413, Forwards Response to NRC Bulleting 88-005 Re Purchasing Documentation & Listing of All Nonconforming Matl,Matl Use Disposition Status & Justification of Continued Operation for All Matls Supplied by West Jersey Mfg Co + (16:42:14, 7 January 2025)
- L-88-402, Forwards Revised Response to Violations Noted in Insp Rept 50-251/88-05.Corrective Actions:Msivs Modified to Utilize safety-related Backup Nitrogen Supply Sys to Ensure Closure in 5 or Less W/O Instrument Air & Steam Flow + (16:42:16, 7 January 2025)
- ML17345A405 + (16:42:17, 7 January 2025)
- 05000250/LER-1988-019, :on 880822,boric Acid Transfer Pump 3A Declared out-of-svc.Caused by Lack of Visible Water Level & Zero Nitrogen Pressure in Seal Pot & Failure of Pump Seal.Seal Replaced & Pump Returned to Svc + (16:42:19, 7 January 2025)
- IR 05000250/1988022 + (16:42:23, 7 January 2025)
- ML17345A400 + (16:42:25, 7 January 2025)
- L-88-403, Forwards Estimated Operator Licensing Exam & Requalification Schedule for FY89-FY92,per Generic Ltr 88-13 + (16:42:26, 7 January 2025)
- 05000250/LER-1988-016, :on 880811,containment Spray Pump out-of-svc for Maint Exceeding Tech Specs Limits.Caused by Lack of Knowledge Re Need for break-in Period for New Bearings. Training Procedures to Be Revised + (16:42:29, 7 January 2025)
- ML17345A397 + (16:42:31, 7 January 2025)
- ML17345A395 + (16:42:33, 7 January 2025)
- ML17345A394 + (16:42:34, 7 January 2025)
- ML17345A392 + (16:42:35, 7 January 2025)
- 05000251/LER-1988-010-01, :on 880819,reactor Trip Occurred Due to lo-lo Steam Generator B Level.Caused by Cognitive Personnel Error. Reactor Control Operator Counseled Re Procedural Compliance & Attention to Details + (16:42:36, 7 January 2025)
- IR 05000250/1988016 + (16:42:38, 7 January 2025)
- ML17345A388 + (16:42:39, 7 January 2025)
- ML17345A387 + (16:42:40, 7 January 2025)
- L-88-405, Forwards Monthly Operating Repts for Aug 1988 for St Lucie & Turkey Point & Corrected Rept of Unit Shutdown & Power Reduction for Jul 1988 for St Lucie Unit 1.Method of Shutting Down Reactor Incorrectly Coded Manual Scram + (16:42:41, 7 January 2025)
- L-88-388, Application for Amends to Licenses DPR-31 & DPR-41,modifying Tech Specs to Require That Operations Superintendent Either Hold or Have Held Senior Operator License (SRO) on Plant or Have Held SRO License on Similar Plant.Fee Paid + (16:42:43, 7 January 2025)
- ML17345A384 + (16:42:43, 7 January 2025)
- 05000250/LER-1988-017, :on 880815,control Room Ventilation Sys Out of Svc in Excess of Tech Spec Time Limit Due to Intermittent Circuit Failure.Caused by Procedural Deficiency.Bridge Circuit Replaced & Plant Mod in Effect + (16:42:46, 7 January 2025)
- L-88-400, Forwards Revised Response to NRC Re Violations Noted in Insp Repts 50-250/86-06 & 50-251/86-06.Corrective Actions:Procedure 3/4-OSP-068.2 Will Be Revised to Establish Requirements for New Ref Values + (16:42:47, 7 January 2025)
- L-88-386, Forwards Summary of mgt-on-shift Weekly Rept Per 871019 Order + (16:42:50, 7 January 2025)
- L-88-409, Forwards Select Sys Assessment Progress Summary for Aug 1988,per 860812 Order + (16:42:55, 7 January 2025)
- 05000251/LER-1988-009, :on 880816,steam Generator Feedwater Pump Tripped During Coating of Condensate Polisher Vessel 4B W/ Resin for Secondary Sys Startup.Caused by Failure of Differential Pressure Switch.Switch Replaced + (16:42:59, 7 January 2025)
- 05000251/LER-1988-008-01, :on 880815,Phase a of Containment Isolation Train a Actuated.Caused by Wire Bundle Bouncing Contacts of Relay 4-SIA2.Actuation Signal Reset + (16:43:02, 7 January 2025)
- 05000251/LER-1988-007-01, :on 880812,while Performing Corrective Maint, Subcritical Reactor Trip Occurred.Caused by Failure of Source Range Neutron Detector N-32.Post-trip Review Performed & Detector Replaced + (16:43:05, 7 January 2025)
- ML17345A374 + (16:43:07, 7 January 2025)