Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18136A440 + (02:42:23, 6 January 2025)
- ML18136A439 + (02:42:23, 6 January 2025)
- 05000280/LER-1980-003-03, /03L-0:on 800107,during Prestartup Testing, Feedwater Bypass Valve HCV-FW-155B Did Not Fail Closed Upon Loss of Instrument Air as Per Design.Caused by Sticking, Dirty Pilot Valve.Valve Cleaned & Returned to Svc + (02:42:25, 6 January 2025)
- 05000280/LER-1980-002-03, /03L-0:on 800106,during Routine Release of Lwtt 80-95,LW Effluent Flow Recorder Paper Did Not Rotate & Thus No Record of Flow Note Was Obtained.Caused by Inadequate Mesh Between Recorder Drive Gears & Recorder Paper Roll + (02:42:27, 6 January 2025)
- ML18136A435 + (02:42:28, 6 January 2025)
- 05000280/LER-1980-001-03, /03L-0:on 800101,w/unit at Cold Shutdown,Snubber 1-WFPD-HSS-14 Found W/Empty Reservoir & Declared Inoperable Per Tech Spec.Caused by Leakage Around Pipe Nipple Threads on Valve Block & Extended Seal Washers.Snubber Replaced + (02:42:29, 6 January 2025)
- 05000280/LER-1980-001, Forwards LER 80-001/03L-0 + (02:42:31, 6 January 2025)
- ML18136A430 + (02:42:32, 6 January 2025)
- ML18136A426 + (02:42:33, 6 January 2025)
- OIG-16-A-15, Status of Recommendations: Independent Evaluation of Security of NRCs Publicly Accessible Web Applications Dated May 16, 2018 + (02:42:34, 6 January 2025)
- ML18136A424 + (02:42:36, 6 January 2025)
- ML18136A422 + (02:42:37, 6 January 2025)
- ML18136A421 + (02:42:38, 6 January 2025)
- ML18136A418 + (02:42:40, 6 January 2025)
- ML18136A420 + (02:42:40, 6 January 2025)
- ML18136A416 + (02:42:41, 6 January 2025)
- 05000280/LER-1979-043-03, /03L-0:on 791220,during Cold Shutdown,Radiation Recorder RR-175 Stopped Printing.Caused by Control String Disengaging from Drive Wheel.String Replaced + (02:42:43, 6 January 2025)
- ML18136A414 + (02:42:44, 6 January 2025)
- 05000280/LER-1979-043, Forwards LER 79-043/03L-0 + (02:42:49, 6 January 2025)
- 05000280/LER-1980-004-01, /01T-0:on 800108,during Routine Startup,Check Valve 1-FW-89 in Discharge Line of Auxiliary Feed Pump Stuck Open.Cause to Be Evaluated by Vendor.Feed Pump & Motor Operated Valves Cycled to Close Valve + (02:42:51, 6 January 2025)
- 05000280/LER-1980-004, Forwards LER 80-004/01T-0 + (02:42:53, 6 January 2025)
- ML18136A403 + (02:42:54, 6 January 2025)
- ML18136A404 + (02:42:54, 6 January 2025)
- ML18136A401 + (02:42:55, 6 January 2025)
- 05000280/LER-1979-044-03, /03L-0:on 791230,during Cold Shutdown,Emergency Diesel Generator 3 Started for Operability Test.Noise Detected in Turbocharger.Cause Under Investigation. Turbocharger Replaced & Returned to Reconditioning + (02:42:57, 6 January 2025)
- 05000280/LER-1979-044, Forwards LER 79-044/03L-0 + (02:42:58, 6 January 2025)
- ML18136A394 + (02:43:00, 6 January 2025)
- ML18136A393 + (02:43:01, 6 January 2025)
- ML18136A392 + (02:43:02, 6 January 2025)
- ML18136A391 + (02:43:03, 6 January 2025)
- ML18136A390 + (02:43:05, 6 January 2025)
- IR 05000280/1979060 + (02:43:06, 6 January 2025)
- ML18136A388 + (02:43:08, 6 January 2025)
- ML18136A387 + (02:43:09, 6 January 2025)
- ML18136A385 + (02:43:10, 6 January 2025)
- 05000280/LER-1979-039-03, /03L-0:on 791214,during Normal Operation,Boric Acid Transfer Pump Strip Heater 2B on Heat Tracing Circuit 26A Failed.Caused by Water Damage to Heat Tracing Circuit. Replaced Strip Heater & Repaired Boric Acid Leak + (02:43:18, 6 January 2025)
- 05000280/LER-1979-039, Forwards LER 79-039/03L-0 + (02:43:20, 6 January 2025)
- ML18136A378 + (02:43:21, 6 January 2025)
- ML18136A377 + (02:43:22, 6 January 2025)
- IR 05000280/1979063 + (02:43:23, 6 January 2025)
- ML18136A374 + (02:43:25, 6 January 2025)
- ML18136A368 + (02:43:26, 6 January 2025)
- ML18136A370 + (02:43:26, 6 January 2025)
- ML18136A367 + (02:43:27, 6 January 2025)
- ML18136A363 + (02:43:28, 6 January 2025)
- ML18136A365 + (02:43:28, 6 January 2025)
- ML18136A362 + (02:43:30, 6 January 2025)
- 05000280/LER-1979-038-03, /03L-0:on 791214,two Manual Isolation Valves for Refueling Water Storage Tank Chemical Addition Tank Outlet Valve MOV-CS-102B Found Closed.Caused by Operator Procedural Error.Operators Instructed + (02:43:31, 6 January 2025)
- 05000280/LER-1979-038, Forwards LER 79-038/03L-0 + (02:43:33, 6 January 2025)
- 05000280/LER-1979-041-21, /21X-0:on 791219,low Reactor Coolant Flow in Loop a Caused Reactor Trip & Safety Injection.Caused by Ground Fault within Reactor Coolant Pump Motor 1A.Motor Replaced + (02:43:34, 6 January 2025)
- 05000280/LER-1979-041, Forwards LER 79-041/21X-0 + (02:43:36, 6 January 2025)