Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18153B517 + (00:11:27, 6 January 2025)
- ML18153B515 + (00:11:28, 6 January 2025)
- PNO-II-88-061, during Wk of 880919,util Identified Some Pipe Wall Thinning in Main Feedwater Piping.On or About 880926, Util Identified Main Feedwater Piping Below Min Code Requirements for Acceptability.Nrc Being Kept Informed + (00:11:30, 6 January 2025)
- ML18153B513 + (00:11:31, 6 January 2025)
- ML18153B512 + (00:11:32, 6 January 2025)
- ML18153B510 + (00:11:33, 6 January 2025)
- 05000280/LER-1988-035, :on 880914,specific Activity Sample of Reactor Coolant Showed Dose Equivalent I-131 Level of 1.04 Microcuries/Cc,Exceeding Tech Spec Limits.Caused by Iodine Spike Due to Fuel Element Defects + (00:11:35, 6 January 2025)
- 05000281/LER-1988-019-03, :on 880901,steam Generator a Inside Containment Steam Valve Closed for No Apparent Reason Due to Actuation of High Flow Trip Solenoid.Solenoid Reset,Blowdown Flow Established & Trip Valve & Solenoid Verified + (00:11:37, 6 January 2025)
- ML18153B506 + (00:11:38, 6 January 2025)
- ML18153B507 + (00:11:38, 6 January 2025)
- ML18153B505 + (00:11:40, 6 January 2025)
- ML18153B503 + (00:11:41, 6 January 2025)
- IR 05000280/1988003 + (00:11:42, 6 January 2025)
- ML18153B501 + (00:11:43, 6 January 2025)
- 05000281/LER-1988-016-02, :on 880731,discovered That Individual Rod Position Indicators (Irpis) Differed from Group Step Demand Counter by Greater than 12 Steps.Caused by Drift in Irpi Indication.Irpis Adjusted + (00:11:45, 6 January 2025)
- ML18153B499 + (00:11:46, 6 January 2025)
- IR 05000280/1988011 + (00:11:47, 6 January 2025)
- 05000280/LER-1988-021, :on 880728,PORV Cycled Open & Then Closed. Caused by Overly Conservative Setpoint.Setpoint Changed + (00:11:49, 6 January 2025)
- ML18153B494 + (00:11:51, 6 January 2025)
- ML18153B495 + (00:11:51, 6 January 2025)
- ML18153B493 + (00:11:52, 6 January 2025)
- ML18153B491 + (00:11:52, 6 January 2025)
- ML18153B490 + (00:11:53, 6 January 2025)
- 05000280/LER-1988-020, :on 880628,control/relay Room Chiller Condenser Svc Water (SW) Pumps & Unit 2 Charging Pump SW Pumps Lost Suction.Caused by Inadequate Procedure.Filling of SW Supply Line Secured & Supply Header Vented + (00:11:54, 6 January 2025)
- IR 05000280/1988022 + (00:11:57, 6 January 2025)
- ML18153B486 + (00:11:59, 6 January 2025)
- ML18153B484 + (00:12:00, 6 January 2025)
- ML18153B485 + (00:12:00, 6 January 2025)
- ML18153B483 + (00:12:01, 6 January 2025)
- 05000281/LER-1988-015-02, :on 880626,rod Urgent Failure Annunciator Activated in Control Room.Caused by Failed Circuit Card & Blown Fuse.Failed Circuit Card & Blown Fuse Replaced & Rod Control Sys Tested Satisfactorily + (00:12:03, 6 January 2025)
- ML18153B481 + (00:12:04, 6 January 2025)
- ML18153B478 + (00:12:06, 6 January 2025)
- ML18153B479 + (00:12:06, 6 January 2025)
- ML18153B477 + (00:12:07, 6 January 2025)
- ML18153B475 + (00:12:08, 6 January 2025)
- IR 05000280/1988023 + (00:12:09, 6 January 2025)
- ML18153B472 + (00:12:18, 6 January 2025)
- IR 05000280/1988017 + (00:12:20, 6 January 2025)
- ML18153B469 + (00:12:22, 6 January 2025)
- ML18153B467 + (00:12:22, 6 January 2025)
- ML18153B466 + (00:12:23, 6 January 2025)
- TAC:M88107 + (00:12:24, 6 January 2025)
- ML18153B465 + (00:12:25, 6 January 2025)
- 05000281/LER-1994-001-01, :on 940124,both Auxiliary Exhaust Filter Trains Declared Inoperable Due to Excessive flow.Six-h Action Statement to Hot Shutdown of Facility Entered Until Normal 1J Bus Alignment Restored + (00:12:26, 6 January 2025)
- IR 05000280/1993026 + (00:12:31, 6 January 2025)
- ML18153B461 + (00:12:32, 6 January 2025)
- ML18153B460 + (00:12:34, 6 January 2025)
- ML18153B459 + (00:12:36, 6 January 2025)
- IR 05000280/1993030 + (00:12:37, 6 January 2025)
- IR 05000280/1993028 + (00:12:38, 6 January 2025)
- ML18153B454 + (00:12:39, 6 January 2025)