Text
..
- D.S.CRUDEN VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 August 2, 1988 VICE PRESIDENT-NUCLEAR United States Nuclear Regulatory Commission Attention:
Document Control Desk Washington, D.C.
20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT NO. 1 STEAM GENERATOR TUBE PLUGGING REPORT Serial No.88-499 PES/ISI/FPB:vlh Rl Docket No.
50-280 License No.
DPR-32 Surry Unit 1 completed eddy current examination of two steam generators during the recent 1988 refueling outage.
A total of 894 tubes in steam generator 118 11 and 895 tubes in steam generator 11C 11 were inspected.
As required by the provisions of paragraph 4.19(F)(a) of Surry Technical Specifications, this letter provides notification that no tubes were plugged in either of these steam generators. This action is supported by the interpretation of eddy current data which indicates that no tubes required plugging as defined in section 4.19(E)(a).
Very truly yours, cc:
U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.
Suite 2900 Atlanta, GA 30323 Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station