Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19257D896 + (21:39:26, 3 January 2025)
- ML19257D895 + (21:39:27, 3 January 2025)
- ML19257D885 + (21:39:29, 3 January 2025)
- 05000324/LER-1980-009-03, /03L-0:on 800114,during Normal Operation, Containment Atmospheric Monitor CAC-AT-1259-1 Failed Upscale.Caused by Loose Ground Connection on Span Potentiometer.Connection Tightened + (21:40:13, 3 January 2025)
- 05000324/LER-1980-009, Forwards LER 80-009/03L-0 + (21:40:44, 3 January 2025)
- ML19257D874 + (21:40:46, 3 January 2025)
- ML19257D873 + (21:40:49, 3 January 2025)
- ML19257D872 + (21:40:53, 3 January 2025)
- ML19257D870 + (21:40:59, 3 January 2025)
- 05000259/LER-1980-005-01, /01T-0:on 800118,during Refueling Outage,While Performing Insp Per IE Bulletin 79-14,found No Seismic Restraints in Drywell of Reactor Bldg Closed Cooling Water Piping.Restraints Will Be Installed Prior to Startup + (21:41:25, 3 January 2025)
- 05000259/LER-1980-005, Forwards LER 80-005/01T-0 + (21:41:30, 3 January 2025)
- 05000259/LER-1980-004-01, /01T-0:on 800118,during Refueling Outage,Ndt Insp Revealed Linear Indication 7/8 Inch Long in Reactor or Water clean-up Sys Weld DRWC-1-2.Cause Unknown.Defect Will Be Removed & Weld Repaired Prior to Startup + (21:41:35, 3 January 2025)
- 05000324/LER-1980-005-03, /03L-0:on 800105,during Normal Operation,Found Isolation Valve for Pressure Switch 2-E11-PS-N010D Shut. Cause Unknown.Counselled Personnel on Necessity to Follow Procedures to Ensure Proper Instrumentation Svc + (21:41:40, 3 January 2025)
- 05000324/LER-1980-003-03, /03L-0:on 800103,during Reactor Startup,Vessel Conductivity Exceeded 2 Umho for 31-h.Caused by Auxiliary Boilers Being Isolated for Months & Supply Lines Containing Stagnant,High Conductivity Water + (21:41:43, 3 January 2025)
- ML19257D863 + (21:41:46, 3 January 2025)
- 05000324/LER-1980-005, Forwards LER 80-005/03L-0 + (21:41:56, 3 January 2025)
- 05000259/LER-1980-004, Forwards LER 80-004/01T-0 + (21:42:00, 3 January 2025)
- ML19257D858 + (21:42:02, 3 January 2025)
- 05000155/LER-1978-047-03, During Plant Startup, Control Rod Drive Temp on Drive E-2 Exceeded Tech Specs. Caused by Failure of Metal O-Ring Seal at Flange.New Seal Ring Installed Prior to Plant Startup.All O-Rings Replaced + (21:42:07, 3 January 2025)
- 05000324/LER-1980-003, Forwards LER 80-003/03L-0 + (21:42:11, 3 January 2025)
- 05000324/LER-1980-006-03, /03L-0:on 800103,during Normal Startup,Control Rod 26-07 Had No Position Indication at Notch 48.During 800109 Startup,Rod 34-35 Had No Indication at Notch 7.Caused by Faulty Reed Switches in Prototypical Inlet Piping Probes + (21:42:15, 3 January 2025)
- 05000324/LER-1980-006, Forwards LER 80-006/03L-0 + (21:42:18, 3 January 2025)
- ML19257D851 + (21:42:20, 3 January 2025)
- ML19257D848 + (21:42:24, 3 January 2025)
- ML19257D847 + (21:42:25, 3 January 2025)
- ML19257D846 + (21:42:26, 3 January 2025)
- 05000155/LER-1979-022-01, Design Review Revealed That,During Loca,Automatic Initiation of Reactor Scram, Containment Isolation,Core Spray & Reactor Depressurization May Not Function + (21:42:35, 3 January 2025)
- 05000317/LER-1979-081-03, /03L-0:on 791225,containment Air Particulate & Gaseous Radiation Monitor Pump Tripped Off Due to Low Air Flow.Cause Undetermined.Air Flows Realigned & Readjusted. Operating Instructions Being Modified + (21:42:39, 3 January 2025)
- 05000317/LER-1979-081, Forwards LER 79-081/03L-0 + (21:42:43, 3 January 2025)
- ML19257D840 + (21:42:45, 3 January 2025)
- 05000318/LER-1979-050-03, /03L-0:on 791228,during Steady State Operation, Channel B Axial Flux Offset Read Higher than Other Channels. Caused by Detector or Integral Detector Cable Vibration + (21:42:50, 3 January 2025)
- 05000318/LER-1979-050, Forwards LER 79-050/03L-0 + (21:43:02, 3 January 2025)
- ML19257D835 + (21:43:04, 3 January 2025)
- ML19257D833 + (21:43:06, 3 January 2025)
- ML19257D832 + (21:43:07, 3 January 2025)
- ML19257D831 + (21:43:08, 3 January 2025)
- ML19257D830 + (21:43:10, 3 January 2025)
- ML19257D829 + (21:43:11, 3 January 2025)
- ML19257D828 + (21:43:13, 3 January 2025)
- ML19257D827 + (21:43:14, 3 January 2025)
- 05000325/LER-1980-002-03, /03L-0:on 800106,during Normal Operation,Point 4 of Chloride Intrusion Monitor 1-CO-CR24 Was Reading Downscale.Caused by Defective Relay & Dirty Contacts.Relay Replaced,Contacts Cleaned & Recorder Returned to Svc + (21:43:46, 3 January 2025)
- ML19257D825 + (21:43:49, 3 January 2025)
- ML19257D824 + (21:43:51, 3 January 2025)
- ML19257D823 + (21:43:52, 3 January 2025)
- ML19257D821 + (21:43:54, 3 January 2025)
- 05000325/LER-1980-002, Forwards LER 80-002/03L-0 + (21:44:25, 3 January 2025)
- ML19257D816 + (21:44:54, 3 January 2025)
- ML19257D815 + (21:44:58, 3 January 2025)
- ML19257D814 + (21:44:59, 3 January 2025)
- ML19257D813 + (21:45:00, 3 January 2025)
- ML19257D810 + (21:45:06, 3 January 2025)