- 05000387/LER-1984-017-01, Updated LER 84-017-01:on 840310,during Performance of Weekly Preventive Maint Activity,Spray Pond Riser Networks A-1 & B-2 Found Frozen.W/Advent of Mild Weather,Networks Thawed & Pumped down.Long-term Fixes Investigated + (04:52:34, 26 May 2025)
- TXX-9203, Interim Deficiency Rept CP-92-03 Re Potential Loss of RHR Due to Flooding of Pump Room.Initially Reported on 911126. Caused by Walkdown Sheet Failing to Address HVAC Vent. Reportability Evaluation Expected by 920227 + (04:52:49, 26 May 2025)
- ML20091P450 + (04:53:01, 26 May 2025)
- ML20091P443 + (04:53:04, 26 May 2025)
- IR 05000329/1982013 + (05:14:14, 26 May 2025)
- 05000416/LER-1984-020-01, Revised LER 84-020-01:on 840423,24 & 0514,during Startup, Five Reactor Water Cleanup Sys Isolations Occurred Due to Feedwater Flow Oscillations + (05:15:45, 26 May 2025)
- ML20091P254 + (05:16:23, 26 May 2025)
- ML20091P252 + (05:16:28, 26 May 2025)
- ML20091P059 + (05:17:04, 26 May 2025)
- ML20091N420 + (05:18:08, 26 May 2025)
- ML20091N387 + (05:18:12, 26 May 2025)
- ML20091N292 + (05:18:31, 26 May 2025)
- ML20091N264 + (05:18:37, 26 May 2025)
- ML20091N259 + (05:18:39, 26 May 2025)
- 05000327/LER-1984-034, :on 840509,valve 1-67-537B Found Mispositioned When Valves 1-FCV-67-123 & 1-FCV-67-124 Opened.Caused by Valve Being Closed Since 840424.Valve Throttled to Proper Position + (05:18:50, 26 May 2025)
- ML20091N215 + (05:19:01, 26 May 2025)
- 05000373/LER-1984-025, :on 840517,trapdoor on Auxiliary Bldg Roof Neither Posted as High Radiation Area Nor Secured to Prevent Unauthorized Entry.Entrance Posted as High Radiation Area, Access Controlled & Door Secured + (05:19:03, 26 May 2025)
- ML20091N203 + (05:19:09, 26 May 2025)
- ML20091N137 + (05:19:17, 26 May 2025)
- ML20091N119 + (05:19:23, 26 May 2025)
- ML20091N103 + (05:19:25, 26 May 2025)
- ML20091N089 + (05:19:27, 26 May 2025)
- ML20091N060 + (05:19:31, 26 May 2025)
- 05000271/LER-1984-006, :on 840508,during Normal Operation,Torus Level Instruments 16-19-46A & 16-19-46B Discovered Reading High. Caused by Hot Slug of Demineralizer Water.Instrument Ref Legs Refilled + (05:19:41, 26 May 2025)
- ML20091N016 + (05:19:45, 26 May 2025)
- ML20091M987 + (05:19:48, 26 May 2025)
- ML20091M974 + (05:19:50, 26 May 2025)
- ML20091M965 + (05:19:54, 26 May 2025)
- ML20091M948 + (05:19:56, 26 May 2025)
- ML20091M917 + (05:20:01, 26 May 2025)
- ML20091M898 + (05:20:03, 26 May 2025)
- ML20091M857 + (05:20:17, 26 May 2025)
- ML20091M845 + (05:20:20, 26 May 2025)
- ML20091M832 + (05:20:27, 26 May 2025)
- ML20091M793 + (05:20:39, 26 May 2025)
- ML20091M791 + (05:20:40, 26 May 2025)
- ML20091M779 + (05:20:43, 26 May 2025)
- ML20091M777 + (05:20:44, 26 May 2025)
- ML20091M772 + (05:20:47, 26 May 2025)
- ML20091M767 + (05:20:49, 26 May 2025)
- 05000311/LER-1984-013, :on 840511,reactor Trip Occurred While Troubleshooting & Calibr Steam Generator narrow-range Level Recorder 22.Caused by Personnel Error.Troubleshooting/Calibr Check Off Sheets Provided to Reduce Accidents + (05:20:51, 26 May 2025)
- ML20091M756 + (05:20:53, 26 May 2025)
- ML20091M737 + (05:20:55, 26 May 2025)
- ML20091M732 + (05:20:57, 26 May 2025)
- ML20091M728 + (05:20:59, 26 May 2025)
- ML20091M708 + (05:21:03, 26 May 2025)
- ML20091M706 + (05:21:04, 26 May 2025)
- ML20091M700 + (05:21:05, 26 May 2025)
- ML20091M690 + (05:21:07, 26 May 2025)
- ML20091M688 + (05:21:08, 26 May 2025)
- 05000374/LER-1984-021-01, :on 840515,during Repair of Filter Demineralizer 2C Post Strainer Section,Outlet Valve Opened & Reactor Water Cleanup Sys Isolated on High Differential Flow.Cause Not Stated + (05:21:12, 26 May 2025)