Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19340E205 + (22:55:16, 24 December 2024)
- 05000155/LER-1980-040-03, /03L-0:on 801202,diesel Fire Pump Unit Did Not Produce Full Discharge Pressure Output Until After Starting Time Acceptance Criteria.Cause Undetermined.Engine Jacket Heater Thermostat Control Setting Increased + (22:55:17, 24 December 2024)
- ML19340E203 + (22:55:18, 24 December 2024)
- ML19340E201 + (22:55:19, 24 December 2024)
- ML19340E200 + (22:55:20, 24 December 2024)
- 05000155/LER-1980-040, Forwards LER 80-040/03L-0 + (22:55:21, 24 December 2024)
- ML19340E196 + (22:55:22, 24 December 2024)
- ML19340E195 + (22:55:23, 24 December 2024)
- ML19340E194 + (22:55:24, 24 December 2024)
- ML19340E192 + (22:55:25, 24 December 2024)
- ML19340E191 + (22:55:26, 24 December 2024)
- 05000237/LER-1980-046-03, /03L-0:on 801202,control Rod Driveline Vol hi-hi Alarm Not Received During Reactor Scram.Caused by Incorrect Cable Length & Routing,Incorrect Transducer Placement & Mounting & Redundant Transducer Signal Interference + (22:55:28, 24 December 2024)
- ML19340E187 + (22:55:29, 24 December 2024)
- ML19340E185 + (22:55:30, 24 December 2024)
- ML19340E180 + (22:55:33, 24 December 2024)
- 05000338/LER-1980-104-99, /99T-0:on 801223,environ Telemetry Channel 6 for Air Temp Found Out of Tolerance High During Calibr.Caused by Printed Circuit Card Failure in Transmitter Multiplexer.Card Removed & Sent to Manufacturer for Repairs + (22:55:34, 24 December 2024)
- ML19340E177 + (22:55:36, 24 December 2024)
- 05000321/LER-1980-122-01, /01T-0:on 801219,QC Insp of Cable Spreading Room & Control Bldg Sprinkler Hangers Installed in 1978 Revealed Deficiencies Which Jeopardize Seismic Qualification of Sprinkler Sys.Caused by Improper Installation + (22:55:37, 24 December 2024)
- ML19340E174 + (22:55:39, 24 December 2024)
- ML19340E173 + (22:55:41, 24 December 2024)
- 05000409/LER-1980-017-01, /01T-0:on 801216,crane Reactor Cavity Purge Check Valve & Bs&B Reactor Vent Header Valve Found Leaking.Caused by Rust & Debris.Valves Replaced + (22:55:42, 24 December 2024)
- 05000321/LER-1980-122, Forwards LER 80-122/01T-0 + (22:55:44, 24 December 2024)
- ML19340E165 + (22:55:48, 24 December 2024)
- ML19340E162 + (22:55:51, 24 December 2024)
- 05000338/LER-1980-104, Forwards LER 80-104/99T-0 + (22:55:52, 24 December 2024)
- ML19340E158 + (22:55:56, 24 December 2024)
- ML19340E156 + (22:55:57, 24 December 2024)
- 05000409/LER-1980-017, Forwards LER 80-017/01T-0 + (22:55:59, 24 December 2024)
- ML19340E151 + (22:56:03, 24 December 2024)
- ML19340E150 + (22:56:04, 24 December 2024)
- ML19340E149 + (22:56:05, 24 December 2024)
- PM-80-126, Special Rept 1-sp-80-3:on 801206,during Routine Survey of Waste Oil Drums,Several Areas on Ground Were Found to Be Contaminated.Caused by Storage of Previous Waste Oil Drums. Addl Controls Re Release of Contaminated Oil Under Review + (22:56:06, 24 December 2024)
- ML19340E147 + (22:56:08, 24 December 2024)
- ML19340E146 + (22:56:12, 24 December 2024)
- ML19340E145 + (22:56:13, 24 December 2024)
- ML19340E144 + (22:56:15, 24 December 2024)
- ML19340E143 + (22:56:16, 24 December 2024)
- ML19340E141 + (22:56:19, 24 December 2024)
- 05000265/LER-1980-036-03, /03L-0:on 801203,electromatic Relief Valve 2-203- 3D Failed to Open During Reactor Pressure Rise Subsequent to Scram.Caused by Excessive Steam Leakage Between Retainer Plug Into Vol Below Main Disc.Valve Replaced + (22:56:21, 24 December 2024)
- ML19340E139 + (22:56:22, 24 December 2024)
- ML19340E138 + (22:56:23, 24 December 2024)
- 05000265/LER-1980-036, Forwards LER 80-036/03L-0 + (22:56:25, 24 December 2024)
- ML19340E134 + (22:56:26, 24 December 2024)
- 05000265/LER-1980-033-03, /03L-0:on 801201,RHR Sys II Supply from Diesel Generator Alarmed.Caused by Blown Fuse F11 Due to Grounded Wire in Unit 2 Diesel Generator to Bus 24-1 Circuit Breaker Auxiliary Contacts.Wire Repaired & Fuse Replaced + (22:56:27, 24 December 2024)
- ML19340E132 + (22:56:28, 24 December 2024)
- 05000327/LER-1980-192-03, /03L-0:on 801201,F14 Control Bank B Rod Position Indicator Deviated by Greater than 12 Steps from Control Bank B Demand Counter.Caused by Shift in Calibr of Control Board Indicator.Indicator Recalibr & Returned to Svc + (22:56:29, 24 December 2024)
- ML19340E130 + (22:56:30, 24 December 2024)
- ML19340E129 + (22:56:33, 24 December 2024)
- 05000265/LER-1980-033, Forwards LER 80-033/03L-0 + (22:56:34, 24 December 2024)
- ML19340E126 + (22:56:35, 24 December 2024)
- 05000327/LER-1980-192, Forwards LER 80-192/03L-0 + (22:56:36, 24 December 2024)