Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000321/LER-1981-010, Forwards LER 81-010/01T-0 + (21:39:17, 24 December 2024)
- ML19341C643 + (21:39:19, 24 December 2024)
- ML19341C644 + (21:39:19, 24 December 2024)
- ML19341C642 + (21:39:20, 24 December 2024)
- TAC:44830 + (21:39:21, 24 December 2024)
- ML19341C640 + (21:39:21, 24 December 2024)
- ML19341C639 + (21:39:22, 24 December 2024)
- ML19341C636 + (21:39:23, 24 December 2024)
- ML19341C638 + (21:39:23, 24 December 2024)
- 05000271/LER-1981-006-03, /03L-0:on 810127,ATWS/recirculation Pump Trip High Pressure Trip Points from PT-2-3-56Bm,56Cm & 56Dm Tripped Above Tech Spec Level During Surveillance Testing Per Operation Procedure 4342.Caused by Instrument Drift + (21:39:24, 24 December 2024)
- IR 05000320/1980015 + (21:39:27, 24 December 2024)
- PNO-II-81-018, on 810224,notification Received Re Indefinite Const Delay on Facilities.Work on Unit 1 Will Be Reduced & Const on Unit 2 Will Be Stopped.Caused by Financial Problems + (21:39:30, 24 December 2024)
- ML19341C632 + (21:39:32, 24 December 2024)
- 05000271/LER-1981-006, Forwards LER 81-006/03L-0 + (21:39:33, 24 December 2024)
- ML19341C628 + (21:39:39, 24 December 2024)
- ML19341C627 + (21:39:41, 24 December 2024)
- 05000346/LER-1981-009-03, /03L-0:on 810128,diesel Generator 1-2 Could Not Be Started W/Left Side Set of Air Start Motors During Diesel Generator Surveillance Test 5081.01.Caused by Failure of One Air Start Motor Due to Broken Solenoid Drive Shaft + (21:39:42, 24 December 2024)
- ML19341C624 + (21:39:43, 24 December 2024)
- ML19341C623 + (21:39:43, 24 December 2024)
- ML19341C621 + (21:39:44, 24 December 2024)
- ML19341C620 + (21:39:45, 24 December 2024)
- ML19341C619 + (21:39:46, 24 December 2024)
- 05000346/LER-1981-009, Forwards LER 81-009/03L-0 + (21:39:47, 24 December 2024)
- ML19341C616 + (21:39:49, 24 December 2024)
- ML19341C615 + (21:39:50, 24 December 2024)
- 05000346/LER-1981-008-03, /03L-0:on 810127,345 Kv Switchyard Bus K Tripped & Locked out,de-energizing Startup Transformer 02.Caused by Action from Directional Ground Current Relay & Charred Phase Lightning Arrestor C on Startup Transformer + (21:39:51, 24 December 2024)
- ML19341C613 + (21:39:52, 24 December 2024)
- ML19341C611 + (21:39:53, 24 December 2024)
- ML19341C610 + (21:39:54, 24 December 2024)
- ML19341C608 + (21:39:54, 24 December 2024)
- 05000346/LER-1981-008, Forwards LER 81-008/03L-0 + (21:39:56, 24 December 2024)
- ML19341C605 + (21:39:57, 24 December 2024)
- ML19341C603 + (21:39:58, 24 December 2024)
- ML19341C604 + (21:39:58, 24 December 2024)
- ML19341C602 + (21:39:59, 24 December 2024)
- 05000312/LER-1981-003-03, /03L-0:on 810203,during Reactor Bldg Spray Sys Loop B Sfas Test,Reactor Bldg Spray Pump B Started Late. Caused by Incorrect Setting on Model 62B Agastat Timer. Timer Reset + (21:40:01, 24 December 2024)
- ML19341C600 + (21:40:02, 24 December 2024)
- 05000312/LER-1981-003, Forwards LER 81-003/03L-0 + (21:40:03, 24 December 2024)
- ML19341C597 + (21:40:04, 24 December 2024)
- ML19341C596 + (21:40:05, 24 December 2024)
- 05000155/LER-1981-003-03, /03L-0:on 810128,backup Nitrogen Bottle Supply for Containment Vacuum Relief Valve Control Sys Depressurized. Caused by Fractured Bottle Isolation Valve Body Probably Due to Overtightening Bonnet Mounting Nut.Valve Replaced + (21:40:06, 24 December 2024)
- ML19341C594 + (21:40:08, 24 December 2024)
- 05000155/LER-1981-003, Forwards LER 81-003/03L-0 + (21:40:09, 24 December 2024)
- 05000255/LER-1981-002-03, Determined That 125 Volt DC Distribution Panel D21A Mounting Did Not Meet Seismic Restraint Criteria.Caused by Engineering Judgment Error. Frame Holding Panel Modified by Adding Braces + (21:40:11, 24 December 2024)
- ML19341C587 + (21:40:12, 24 December 2024)
- ML19341C586 + (21:40:13, 24 December 2024)
- ML19341C585 + (21:40:14, 24 December 2024)
- AECM-80-254, Deficiency Rept Re Failure of Tack Weld on safety-related Automatic Air Damper Supplied by Pacific Air Products Co, Initially Reported on 800912.Util Working W/Constructor Re Reportability Per 10CFR50.55e & 10CFR21 + (21:40:14, 24 December 2024)
- ML19341C581 + (21:40:17, 24 December 2024)
- ML19341C582 + (21:40:17, 24 December 2024)
- ML19341C579 + (21:40:18, 24 December 2024)