ML19341C594

From kanterella
Jump to navigation Jump to search
Submits Assessment of SEP Topic II-2.A, Severe Weather Phenomena. NRC Consultant Should Make Site Specific Review of Terrain Effects & re-evaluate Potential of Tornadoes & Max Wind Speeds at Site
ML19341C594
Person / Time
Site: Yankee Rowe
Issue date: 02/10/1981
From: Kay J
YANKEE ATOMIC ELECTRIC CO.
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
TASK-02-02.A, TASK-2-2.A, TASK-RR FYR-81-26, NUDOCS 8103030800
Download: ML19341C594 (3)


Text

,

YANKEE ATOMIC ELECTRIC COMPANY m.

J~ u,4 yN D671 Worcester Road, Framingham, Massachusetts 01701 2 C.2.1 Yauxse m 81-26 s

February 10, 1981 e

g C

s U. S. Nuclear Regulatory Commission F

n Washington, D.C. 20555

',D 0 2.1981u,E.

C 3 u.s,Q'%idg%

~.

Attention:

Mr. Dennis M. Crutchfield, Chief g

Operating Reactors Branch #5 g

Division of Licensing

/j Re fe re nc e s :

(a) License No. DPR-3 (Docket No. 50-29)

(b) USNRC Letter to YAEC dated December 17, 1980

Subject:

Yankee Rowe - SEP Topic II-2.A

Dear Sir:

As requested in Reference (b), we are hereby forwarding our assessment of SEP Topic Il-2.A, Sevet: Weather Phenomena, for the Yankee Rowe site.

Since receipt of your letter, our staff has conducted a preliminary review of those meteorological parameters outlined in Enclosure 1, which have been designated as (1) extreme temperatures, (2) thunderstorm / lightning strikes, (3) design wind speed, (4) radial ice thickness, (5) snow loading, and (6) tornado loading.

In general, we concur with the NRC specifics for the first four items.

We do not agree, however, with the NRC's evaluation of tSe snow and tornado loading, items fivs and six.

The snow load, for instance, is based on the maximum winter precipitation derived from Hydrometeorlogical Report No. 33.

But neither this report nor its updated version, Hydrometeorological Report No. 51, is entirely applicable to the Rowe site because, as pointed out in each document, the data have not been evaluated with respect to terrain effects and, therefore, might be deficient in estiinating maximum precipitation.

Our stafi recognized this limitation when responding to SEP Topic II-3.B, Flooding Potential. Work conducted for this topic demonstrated that terrain e ffects must be accounted for at the Rowe site. When applied to maximum precipitation, the terrain effects resulted in values considerably less than those contained in Hydrometeorological Report 33.

Accordingly, we feel that the snow load parameter should be re-evaluated to include information on site specific terrain e ffects.

In a similar light, we feel that the tornado frequency and resultant wind loading on plant structures as derived in Enclosure 2 of your letter may be high. The tornado probability model in Enclosure used tornado data from an area representing tens o ? thousands of square miles in the Northeast.

But our review of National Weather Service tornado data within 125 miles of the Rowe site (see enclosed figure) indicates that tornadoes generally occur less frequently in mountainous terrain.

In addition, howe's location within the steep and narrow Deerfield River Valley should also offer the plant protection from the more intense tornado wind speed s outlined in Enclosure 2.

We therefore feel that by considering site specific terrain characteristics

~P 81osoa0/p0

U. S. Fr". lear Regulatory Commission

[

February 10, 1981 Page 2 not only will the likelihood of a tornado in the valley be reduced considerably, but also its intensity. We feel your consultant should make a site specific review of terrain effects and reevaluate the potential of torr.adoes and maximum wind speeds at the Rowe site.

In this manner, the risks related to the plant and its design parameters may be better established.

If you have any questions or desire additional information, please contact us.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

. /d J. A. Kay Senior Engineer - Licensing JHS/sec

I i

REPORTED TORNADO EVENTS I

125 N. MILE RADIUS NATIONAL k'EATilER DATA SERVICE I,'

I I

/ ',

/'s e

I I I s

j r

r r,

a

$y j

8 i

i s I

\\

l i

\\

i s

g t

I g

s I

ll II

{

j lD.

)

I d

I s

1 I

p

[ p,

(,~,

l*

s' I I t

I

/

2 8

I I

I il I

i

~

y/

)

s I

/

/ I I

CONCORD' 2

I I

al ll 2 9

I I

I

)

I e l1 i

l j

I 121 1

g i

~

)

i

(,'

ROWE 7[g i

i 1

1 2 1 I I

I i

i i

-s I

i

./

,m I

8

/

IO Il 8

f g\\ s ALBANY li g

2 l

t 2

I I

\\

l 3

i II 2

Ill I s_s I

\\

g

)

3 I t

8

\\

12 2

i BOSTON

)

/

) 211 22 i

I I '

f 4

s I

2 2

1 I

ISPRINGFIELD g

i t

g, g

l li 3

3M3I I

g g

i i

I eii 1

2 I

s i i 2I 18 l/ l I

I I

,-s l

l 2 i 3

q

/

I HARTFORh PROVIDENCE

~

s gI i

l 21 2 gg 3

II I

p i

i i I

II I g

1 I

g a

8 I

O M LES 50 I

._ - MOUNTAIN RANGE LIMITS I

( >l640 FT.,500 M.)

2

- - -