Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20009A967 + (06:38:53, 23 December 2024)
- 05000331/LER-1981-022-03, /03L-0:on 810607,during Testing,Reactor Core Isolation Cooling Turbine Repeatedly Tripped on Overspeed on Fast Starts.Caused by Upward Drift of Flow Controller FIC-2509 High Limit Setpoint.Setpoint Recalibr + (06:38:54, 23 December 2024)
- ML20009A965 + (06:38:56, 23 December 2024)
- ML20009A964 + (06:38:57, 23 December 2024)
- GO2-81-165, Interim Deficiency Rept Re Diesel Generator Bldg Heating Ventilation & Air Conditioning Sys Intake Ductwork Originally Reported 810417.Studies in Progress to Determine Suitable Prevention of Collapse of Ductwork + (06:38:58, 23 December 2024)
- ML20009A960 + (06:39:00, 23 December 2024)
- 05000331/LER-1981-022, Forwards LER 81-022/03L-0 + (06:39:02, 23 December 2024)
- ML20009A957 + (06:39:03, 23 December 2024)
- ML20009A956 + (06:39:05, 23 December 2024)
- 05000295/LER-1981-028-03, /03L-0:on 810615,during Normal Operation,Stack Gas Radiation Monitor ORE-0014 Began Spiking Erratically.Cause Unknown.Gm Tubes,Model 12NB3,replaced + (06:39:06, 23 December 2024)
- ML20009A953 + (06:39:08, 23 December 2024)
- PNO-II-81-049, on 810708,Intl Brotherhood of Electric Workers Commenced Strike Against Util.Watch Turnover from Union Members to Supervisory Staff Completed in Orderly Manner. Region Providing Continuous Inspector Coverage + (06:39:10, 23 December 2024)
- 05000295/LER-1981-028, Forwards LER 81-028/03L-0 + (06:39:12, 23 December 2024)
- 05000255/LER-1981-022-03, /03L-0:on 810531,pump Suction Snubber 43 Found Leaking Oil.Caused by Apparent O-ring Failure.Snubber Disassembled + (06:39:14, 23 December 2024)
- ML20009A946 + (06:39:16, 23 December 2024)
- ML20009A945 + (06:39:17, 23 December 2024)
- ML20009A944 + (06:39:17, 23 December 2024)
- ML20009A942 + (06:39:18, 23 December 2024)
- 05000255/LER-1981-022, Forwards LER 81-022/03L-0 + (06:39:20, 23 December 2024)
- IR 05000341/1981007 + (06:39:25, 23 December 2024)
- 05000305/LER-1981-020-03, /03L-0:on 810606,condensate Water Storage Tank Level Went Below Tech Spec Limit.Caused by Normal Tank Water Usage During Startup & Turbine Testing Coincident W/ Demineralizer Regeneration + (06:39:27, 23 December 2024)
- ML20009A936 + (06:39:29, 23 December 2024)
- ML20009A937 + (06:39:29, 23 December 2024)
- ML20009A935 + (06:39:31, 23 December 2024)
- ML20009A934 + (06:39:31, 23 December 2024)
- 05000305/LER-1981-020, Forwards LER 81-020/03L-0 + (06:39:33, 23 December 2024)
- ML20009A930 + (06:39:35, 23 December 2024)
- IR 05000206/1981018 + (06:39:41, 23 December 2024)
- ML20009A927 + (06:39:42, 23 December 2024)
- ML20009A925 + (06:39:43, 23 December 2024)
- ML20009A922 + (06:39:51, 23 December 2024)
- IR 05000344/1981016 + (06:39:52, 23 December 2024)
- ML20009A919 + (06:39:56, 23 December 2024)
- ML20009A917 + (06:39:57, 23 December 2024)
- ML20009A916 + (06:39:59, 23 December 2024)
- IR 05000361/1981011 + (06:40:01, 23 December 2024)
- ML20009A913 + (06:40:02, 23 December 2024)
- 05000266/LER-1981-006-01, /01T-0:on 810621,spray Additive Isolation Valve 1-831A Found Shut.Caused by Failure of Operator to Position Valve Correctly After Surveillance Testing.Valve Repositioned & Locked Open + (06:40:04, 23 December 2024)
- 05000266/LER-1981-006, Forwards LER 81-006/01T-0 + (06:40:07, 23 December 2024)
- 05000255/LER-1981-023-03, /03L-0:on 810602,during Testing,Diesel Generator 1-1 Unable to Maintain Constant Load.Caused by Generator Droop Setting Being Out of Adjustment.Droop Adjusted + (06:40:09, 23 December 2024)
- 05000255/LER-1981-023, Forwards LER 81-023/03L-0 + (06:40:11, 23 December 2024)
- 05000255/LER-1981-024-03, /03L-0:on 810606,diesel Generator 1-1 Valve CV- 0884 Observed Passing Full Flow W/Actuator in Closed Position.Caused by Sheared Operator to Valve Shaft Key Due to Damaged Liner Permitting Misalignment of Shaft & Disc + (06:40:13, 23 December 2024)
- ML20009A905 + (06:40:22, 23 December 2024)
- 05000315/LER-1981-016-03, /03L-0:on 810601,procedure Review Revealed That Selected Valves Were Not Cycled at Frequency & in Operating Modes Required by Tech Specs.Caused by Personnel Error. Procedures Revised + (06:40:23, 23 December 2024)
- 05000315/LER-1981-016, Forwards LER 81-016/03L-0 + (06:40:28, 23 December 2024)
- ML20009A900 + (06:40:33, 23 December 2024)
- 05000255/LER-1981-024, Forwards LER 81-024/03L-0 + (06:40:35, 23 December 2024)
- ML20009A897 + (06:40:36, 23 December 2024)
- ML20009A896 + (06:40:37, 23 December 2024)
- 05000346/LER-1981-032, Forwards LER 81-032/03L-0 + (06:40:38, 23 December 2024)
- ML20009A893 + (06:40:39, 23 December 2024)