50.55(e) Report Docket Nos. 50-361/362 Southem Califomia Edison Company l/ ?

=n

[Og7

p. o. sox e00 2244 WALNUT GROVE AVENUE

- Q, #C.y g ROSEMEAD, CALIFORNIA 91770 vice persiount 3 572 1474 July 1, 1.981 (t. ~/s

~

1 Y

Mr. R. H. Engelken, Director

[c# ((

t Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission

{

Region V

)._ JUL 13 793y,,,

3 Suite 202, Walnut Creek Plaza d "d'",ggra 1990 North California Boulevard V

Walnut Creek, California 94596 M

N' m

Dear Mr. Engelken:

Subject:

Docket Nos. 50-361 and 50-362 San Onofre Nuclear Generating Station, Units 2 and 3 By letter to your office dated May 18, 1981 we traus-mitted a final report in accordance with 10CFR50.55(e) regard-ing noncompliance with ASME Code NCA-3867.4a on chemical analysis verification of material used for manufacture of ASME Code bolts with nominal diameter exceeding one inch.

That report stated that ASME Code Case N242 would be invoked by the Project for these bolts.

The purpose of this letter is to advise you that Code Case N-310, which deals specifically with bolting materials and which w9.s confirmed by publication June, 1981, will be in-voked instead of Code Case N-242.

l If you have any questions regarding this supplement to the report, we would be pleased to discuss them with you at your convenience.

Very trul

yours,

\\

/~ L. T. Papay

/

l cc:

Victor Stello (NRC, Director I&E)

{

R. J. Pate (NRC, San Onofre, Units 2 and 3 l

8107140501 810701 t

PDR ADOCK 05000361 S

PDR BHol

.