- ML20028B468 + (00:16:38, 21 December 2024)
- 05000298/LER-1982-022-03, /03L-0:on 821025,RHR Time Delay Relay 10A-K45A Failed to Operate within Required Time Limits.Caused by Setpoint Being Set Too Conservatively.Relay Readjusted & Correct Operation Verified + (00:16:40, 21 December 2024)
- 05000298/LER-1982-021-03, /03L-0:on 821023,relay 917-16A-K44B Failed to Open Contacts When de-energized.Cause Not Determined.Relay Replaced & Correct Operation Verified.Monitoring Program Implemented to Determine Need for Generic Replacement + (00:16:42, 21 December 2024)
- ML20028B464 + (00:16:43, 21 December 2024)
- IR 05000244/1982022 + (00:16:46, 21 December 2024)
- 05000298/LER-1982-022, Forwards LER 82-022/03L-0.Detailed Event Analysis Submitted + (00:16:48, 21 December 2024)
- 05000298/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Submitted + (00:16:49, 21 December 2024)
- ML20028B457 + (00:16:51, 21 December 2024)
- ML20028B455 + (00:16:52, 21 December 2024)
- ML20028B452 + (00:16:53, 21 December 2024)
- IR 05000322/1982020 + (00:16:55, 21 December 2024)
- ML20028B448 + (00:16:56, 21 December 2024)
- IR 05000333/1982021 + (00:16:57, 21 December 2024)
- IR 05000387/1982038 + (00:16:59, 21 December 2024)
- ML20028B444 + (00:17:00, 21 December 2024)
- ML20028B442 + (00:17:01, 21 December 2024)
- ML20028B441 + (00:17:01, 21 December 2024)
- ML20028B439 + (00:17:02, 21 December 2024)
- ML20028B437 + (00:17:03, 21 December 2024)
- ML20028B436 + (00:17:04, 21 December 2024)
- GO2-82-938, Final Deficiency Rept 216 Re RHR Relief Valve Vent.Initially Reported by Burns & Roe Under Part 21.Dual Reporting Not Required.Part 21 Repts Will Adequately Address Problem & Corrective Action + (00:17:10, 21 December 2024)
- ML20028B429 + (00:17:12, 21 December 2024)
- ML20028B431 + (00:17:12, 21 December 2024)
- ML20028B428 + (00:17:13, 21 December 2024)
- ML20028B426 + (00:17:13, 21 December 2024)
- ML20028B424 + (00:17:15, 21 December 2024)
- ML20028B423 + (00:17:16, 21 December 2024)
- ML20028B422 + (00:17:17, 21 December 2024)
- ML20028B421 + (00:17:18, 21 December 2024)
- ML20028B419 + (00:17:18, 21 December 2024)
- ML20028B418 + (00:17:19, 21 December 2024)
- ML20028B417 + (00:17:20, 21 December 2024)
- ML20028B416 + (00:17:21, 21 December 2024)
- 05000266/LER-1982-017-01, /01T-0:on 821030,four Tubes in Steam Generator a & Three Tubes in Steam Generator B Indicated Degradation Greater than 40% Plugging Limit.Caused by Intergranular Attack.Tubes Mechanically Plugged + (00:17:22, 21 December 2024)
- ML20028B414 + (00:17:23, 21 December 2024)
- IR 05000361/1982037 + (00:17:24, 21 December 2024)
- IR 05000341/1982010 + (00:17:26, 21 December 2024)
- ML20028B408 + (00:17:28, 21 December 2024)
- ML20028B406 + (00:17:31, 21 December 2024)
- ML20028B404 + (00:17:32, 21 December 2024)
- ML20028B401 + (00:17:33, 21 December 2024)
- ML20028B402 + (00:17:33, 21 December 2024)
- ML20028B400 + (00:17:35, 21 December 2024)
- ML20028B397 + (00:17:36, 21 December 2024)
- ML20028B396 + (00:17:36, 21 December 2024)
- ML20028B395 + (00:17:37, 21 December 2024)
- 05000272/LER-1982-084-99, /99X-0:on 821011,diesel Generator Area Low Pressure Carbon Dioxide Sys Automatic Actuation Feature Disabled & Tagged Out for Planned Maint.Continuous Fire Watch W/Backup Fire Suppression Equipment Established + (00:17:39, 21 December 2024)
- IR 05000298/1982022 + (00:17:41, 21 December 2024)
- IR 05000020/1982002 + (00:17:43, 21 December 2024)
- ML20028B390 + (00:17:44, 21 December 2024)
- 05000311/LER-1982-126-03, /03L-0:on 821019,analysis of Sample Charging Pump 21 Lube Oil Revealed That water-oil Mixture Existed. Caused by Lube Oil Cooler Failure Due to Excessive Corrosion & Erosion.Cooler Replaced + (00:17:45, 21 December 2024)