IR 05000361/1982037

From kanterella
Jump to navigation Jump to search
Corrected IE Safeguards Insp Repts 50-361/82-37 & 50-362/82-25 on 820927-1005.No Noncompliance Noted.Major Areas Inspected:Security Plan,Records & Repts,Testing & Maint,Locks & Keys.Details Withheld (Ref 10CFR73.21)
ML20028B413
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 11/09/1982
From: Ervin N, Mcqueen A, Mortensen W, Norderhaug L, Schaefer D, Schuster M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML20028B405 List:
References
50-361-82-37, 50-362-82-25, NUDOCS 8211300361
Download: ML20028B413 (2)


Text

-

-[k~

3bEGUARDS INFORMATIOb

... -,.

.

.

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Report Nos. 50-361/82-37, 50-362/82-25 (IE-V-530)

Docket Nos. 50-361, 50-362 License Nos. NPF-10, None Licensee: Southern California Edison Company P. O. Box 800 2244 Walnut Grove Avenue Rosemead, California 91770 Facility Name: San Onofre Nuclear Generating Station, Units 2 & 3 Inspection at: Camp Pendleton, California Inspection Conducted: September 27, 1982 through October 5, 1982 Date of Last Physical Security Inspection Visit: None Type of Inspection: Announced, Preoperational, Physical Security Inspectors:D@

edsb i, /o/12 M. D. Schuster, Chief, Physical Security Section Date Signed and Inspection Team Leader e

d Ilk /n

~~"

W. P.

46rtenisen, ' Physical SeEurity Inspector Ddtd Signed IvDh.D. hA $

,, l9 J+ -> -

D. W. Schaefer, Physical Security Inspector Date Signed

,

on 0.

bu$

i,10l0 V N. E. Ervin, Physical Security Inspector Date Signed 0.W)a'<0 w

//l9l9&

A. D. Mc,Que s'c 1 S'ecurity spector Date Signed

,

,

//

/

M^m

///v/#2_.

Approved by:/

'

L. RYNordgr'hiatrg yfrsafeguards fleaud Date Signed

-

Inspection Summary Areas Inspected: Security Plan; Security Organization-Management; Security Organization-Personnel; Semrity Organization-Response; Records and Reports; Testing and Maintenance; Locks, Keys, and Combinations; Physical Barriers -

Protected Area; Physical Barriers - Vital Areas; Security System Power Supply; EEC.0SW2 CONTAINS SAFEOUARDS INFORMATION.

UPON SEPARATION T!!IS PAGE IS DSCONTROILED.

R A CEGUARDS INFORMATION ggg3g g

PDR ADOCK 05000361 a

PDR

<-

-

,.

,

lI'~

(

(.'

-

,

,*

o'

'..

.

Inspection Summary-2-Lighting; Assessoent Aids; Access Control - Personnel; Access Control - Packages; Access Control - Vehicles; Detection Aids - Protected Area; Detection Aids -

Vital Areas; Alarm Stations; Communications; and Independent Effort.

The inspection involved 345 hours0.00399 days <br />0.0958 hours <br />5.704365e-4 weeks <br />1.312725e-4 months <br /> on site by the inspection team. The inspection-was begun during regular hours; of the total on-site inspection hours, 95 were accomplished during off-shift periods.

Findings: The licensee was-found to be in compliance with their operating license requirements, within the areas inspected, except for the following three items:

1.

Failure to search all personnel prior to protected area access (Severity Level IV).

2.

Failure to search personnel in conformance with approved security plan (Severity Level IV).

,

3.

Unsecure vital area portal (Severity Level IV).

.

t

w S * D 4% e4 -

vet

.4