Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19305E555 + (10:18:49, 2 January 2025)
- ML19305E554 + (10:18:51, 2 January 2025)
- ML19305E552 + (10:18:52, 2 January 2025)
- ML19305E550 + (10:18:53, 2 January 2025)
- ML19305E549 + (10:18:54, 2 January 2025)
- ML19305E548 + (10:18:55, 2 January 2025)
- IR 05000321/1980007 + (10:18:59, 2 January 2025)
- ML19305E546 + (10:19:00, 2 January 2025)
- PNO-III-80-082, on 800501,util Notified Resident Inspector That Test Results of Samples of Pipe Whip Restraint Bolts Indicated Lower than Acceptable Strength in Two of Four Bolts.Caused by Manufacturer Defect.Problem Under Review + (10:19:02, 2 January 2025)
- ML19305E544 + (10:19:03, 2 January 2025)
- ML19305E543 + (10:19:04, 2 January 2025)
- ML19305E542 + (10:19:05, 2 January 2025)
- ML19305E540 + (10:19:06, 2 January 2025)
- PNO-I-80-068, on 800501,four Plant Workers Were Taken by Ambulance to Local Hosp for Observation After Becoming Nauseous While Using Isopentyl Alcohol.Caused by Attempt to Decontaminate Spent Fuel Shipping Cask + (10:19:08, 2 January 2025)
- ML19305E537 + (10:19:09, 2 January 2025)
- ML19305E535 + (10:19:10, 2 January 2025)
- ML19305E534 + (10:19:11, 2 January 2025)
- IR 05000508/1980002 + (10:19:14, 2 January 2025)
- ML19305E530 + (10:19:16, 2 January 2025)
- ML19305E531 + (10:19:16, 2 January 2025)
- ML19305E529 + (10:19:17, 2 January 2025)
- ML19305E528 + (10:19:18, 2 January 2025)
- ML19305E527 + (10:19:19, 2 January 2025)
- ML19305E525 + (10:19:20, 2 January 2025)
- ML19305E523 + (10:19:21, 2 January 2025)
- ML19305E522 + (10:19:22, 2 January 2025)
- ML19305E521 + (10:19:23, 2 January 2025)
- ML19305E520 + (10:19:23, 2 January 2025)
- IR 05000338/1980010 + (10:19:25, 2 January 2025)
- ML19305E518 + (10:19:26, 2 January 2025)
- ML19305E516 + (10:19:27, 2 January 2025)
- ML19305E514 + (10:19:28, 2 January 2025)
- ML19305E513 + (10:19:29, 2 January 2025)
- ML19305E512 + (10:19:30, 2 January 2025)
- ML19305E510 + (10:19:31, 2 January 2025)
- ML19305E507 + (10:19:32, 2 January 2025)
- PNO-III-80-081, on 800430,while Entering Area Under Reactor Vessel to Survey for Possible Water Leaks,Three of Plant Personnel Received Estimated Doses of 3-8 Rems.Possibly Caused by Faulty Radiation Survey Meter + (10:19:34, 2 January 2025)
- ML19305E505 + (10:19:35, 2 January 2025)
- ML19305E504 + (10:19:36, 2 January 2025)
- ML19305E503 + (10:19:37, 2 January 2025)
- ML19305E501 + (10:19:38, 2 January 2025)
- ML19305E500 + (10:19:39, 2 January 2025)
- ML19305E498 + (10:19:43, 2 January 2025)
- ML19305E497 + (10:19:44, 2 January 2025)
- ML19305E496 + (10:19:45, 2 January 2025)
- ML19305E494 + (10:19:46, 2 January 2025)
- PNO-II-80-060, on 800415,Unit 2 Tripped When Instrument Mechanic Created Open Circuit on Three Element Feed/Steam Flow Circuit Due to Low Reactor Water Level.Unit 2 Reactor Trip,Electrical Shutdown Bus 2 Overheated + (10:19:48, 2 January 2025)
- TAC:10473 + (10:19:49, 2 January 2025)
- ML19305E492 + (10:19:49, 2 January 2025)
- ML19305E491 + (10:19:50, 2 January 2025)
- PNO-II-80-057, on 800410,licensee Reported Two Electricians Fatally Injured When Bucket Lift Truck Overturned.One Electrician Transported to Local Hospital & Pronounced Dead on Arrival;Second Died in Onsite Infirmary + (10:19:52, 2 January 2025)