Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20059N793 + (05:35:29, 17 December 2024)
- ML20059N788 + (05:35:30, 17 December 2024)
- ML20059N790 + (05:35:30, 17 December 2024)
- ML20059N787 + (05:35:31, 17 December 2024)
- ML20059N782 + (05:35:32, 17 December 2024)
- ML20059N779 + (05:35:32, 17 December 2024)
- ML20059N776 + (05:35:33, 17 December 2024)
- JSP-746-90, Forwards Rev 2 to Updated FSAR for Clinton Power Station & 10CFR50.59 Rept for Apr 1989 - Mar 1990 + (05:35:34, 17 December 2024)
- ML20059N772 + (05:35:34, 17 December 2024)
- B13650, Submits Addl Info Re NRC 900925-27 Review of Util fitness- for-duty Incidents + (05:35:35, 17 December 2024)
- NLS9000444, Forwards Rev 13 to Emergency Plan & Rev 12 to EPIP 5.7.1 Re Emergency Classification + (05:35:48, 17 December 2024)
- ML20059N760 + (05:35:48, 17 December 2024)
- LIC-90-0776, Lists Open Items Categories in Design Basis Reconstitution Program for Containment Cooling + (05:36:27, 17 December 2024)
- ML20059N751 + (05:36:27, 17 December 2024)
- ML20059N748 + (05:36:28, 17 December 2024)
- ML20059N747 + (05:36:28, 17 December 2024)
- ML20059N744 + (05:36:29, 17 December 2024)
- ML20059N743 + (05:36:29, 17 December 2024)
- PNO-III-90-067, on 901003,small Unplanned Release of Noble Gases Occurred While Personnel Collecting Gas Sample from Vol Control Tank.Release Apparently Occurred as Result of Seal Failure on Gas Analyzer Sample Pump + (05:36:30, 17 December 2024)
- ML20059N740 + (05:36:30, 17 December 2024)
- ML20059N738 + (05:36:32, 17 December 2024)
- ML20059N736 + (05:36:33, 17 December 2024)
- ML20059N731 + (05:36:37, 17 December 2024)
- ML20059N733 + (05:36:37, 17 December 2024)
- ML20059N729 + (05:36:38, 17 December 2024)
- ML20059N727 + (05:36:41, 17 December 2024)
- PY-CEI-NRR-1227, Forwards Rept of Unsatisfactory Licensee Blind Performance Test Procedure Result Received from Lab + (05:36:42, 17 December 2024)
- ML20059N725 + (05:36:42, 17 December 2024)
- ML20059N724 + (05:36:43, 17 December 2024)
- NRC-90-0156, Forwards Revised Response to NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount. Determined That Time at Pressure for Failed Transmitters Listed on Page 10 of Encl Incorrectly Calculated.Time Was 4 Months Too Long + (05:36:44, 17 December 2024)
- NLS9000373, Discusses Util 890724 & 900430 Responses to Generic Ltr 88-01 Re RWCU Sys Piping & Welds.List of Welds in Question Encl.Remaining RWCU Piping & Welds within Scope of Generic Ltr Were Replaced During 1990 Refueling Outage + (05:36:44, 17 December 2024)
- ML20059N718 + (05:36:45, 17 December 2024)
- ML20059N716 + (05:36:46, 17 December 2024)
- ML20059N715 + (05:36:47, 17 December 2024)
- 05000374/LER-1990-010-06, :on 900912,reactor Scram on Generator Lockout During Surveillance Testing Due to Short to Ground on Phase B Current Transformer in Main Power Transformer 2E.Cause Not Determined.Surveillance Reperformed + (05:36:48, 17 December 2024)
- ML20059N712 + (05:36:49, 17 December 2024)
- 05000328/LER-1990-013-02, :on 900911,loss of RHR Shutdown Cooling Due to Inadvertent Deenergization Occurred.Caused by Oversight During Impact Evaluation.Event Reviewed W/Personnel + (05:36:51, 17 December 2024)
- 05000306/LER-1990-006-02, :on 900912,excessive Leakage Through Containment Isolation Valve Due to Valve Malfunction Occurred.Caused by Inadequate Work Instructions.Valve Travel Stop Adjusted + (05:36:53, 17 December 2024)
- ML20059N704 + (05:36:54, 17 December 2024)
- IR 05000456/1990016 + (05:37:26, 17 December 2024)
- 05000353/LER-1990-015-02, :on 900910,reactor Scram Occurred Due to Spurious Trip Signal from Steam Leak Detection Sys Temp Switch.Caused by Equipment Failure.Temp Switch TTS-25-216D Was Replaced + (05:37:28, 17 December 2024)
- NUREG-5055, Notification of 901017 Meeting W/Util in Rockville,Md,To Discuss Proposed Mods to Control Bldg Per NUREG-5055 + (05:37:29, 17 December 2024)
- ML20059N700 + (05:37:29, 17 December 2024)
- ML20059N698 + (05:37:30, 17 December 2024)
- ML20059N697 + (05:37:32, 17 December 2024)
- 05000344/LER-1990-037, :on 900907,lightning Strike on Distribution Sys Grid Resulted in Momentary Undervoltage on Secondary Side of Startup Transformers & Emergency Diesel Generator Start. No Corrective Actions Necessary + (05:37:33, 17 December 2024)
- ML20059N695 + (05:37:34, 17 December 2024)
- ML20059N691 + (05:37:39, 17 December 2024)
- ML20059N690 + (05:37:40, 17 December 2024)
- ML20059N687 + (05:37:40, 17 December 2024)
- ML20059N686 + (05:37:41, 17 December 2024)
- IR 05000254/1990014 + (05:37:48, 17 December 2024)