- ML20064M863 + (01:17:43, 17 December 2024)
- ML20064M860 + (01:17:43, 17 December 2024)
- 05000277/LER-1982-021-03, /03L-0:on 820620,combined Leakage for Type B & C Tests Exceeded 0.6 La.Caused by Failure of MSIV Due to Improper Seat Contact Resulting from Damaged Seats,Plugs & Guides.Valves Repaired & Tested + (01:17:49, 17 December 2024)
- 05000413/LER-1994-003-01, :on 940222,determined TS 3.3.1 Table 3.3-1 Action Statement Violations Occurred.Operations,Instrument & Electrical Procedures Revised + (01:17:51, 17 December 2024)
- ML20064M838 + (01:17:52, 17 December 2024)
- 05000255/LER-1982-022-03, /03L-0:on 820730,during Insp of Ess sys,3/4-inch, 200 Psi,Threaded Bronze Valve Found Installed at MV-3420. Cause Undetermined.Bronze Valve Replaced.Current Documentation Methods Would Preclude Recurrence + (01:17:53, 17 December 2024)
- ML20064M827 + (01:17:54, 17 December 2024)
- ML20064M824 + (01:17:55, 17 December 2024)
- ML20064M819 + (01:17:59, 17 December 2024)
- ML20064M821 + (01:17:59, 17 December 2024)
- ML20064M818 + (01:18:01, 17 December 2024)
- ML20064M814 + (01:18:01, 17 December 2024)
- ML20064M809 + (01:18:02, 17 December 2024)
- ML20064M813 + (01:18:02, 17 December 2024)
- 05000255/LER-1982-022, Forwards LER 82-022/03L-0 + (01:18:03, 17 December 2024)
- ML20064M807 + (01:18:03, 17 December 2024)
- 05000361/LER-1982-076-03, /03L-0:on 820725,steam Generator Delta Pressure Indicator 2PD1-0979-1 Failed Channel Check Test & Placed in Bypass Condition.Caused by Indicator Being Valved Out. Correct Valve Lineup Restored + (01:18:05, 17 December 2024)
- ML20064M791 + (01:18:06, 17 December 2024)
- ML20064M786 + (01:18:07, 17 December 2024)
- 05000269/LER-1994-001-04, :on 940221,determined Seismic/Loop Event May Result in Loss of post-accident Cooling Due to Design Deficiency.All Engineering Documents & Training Revised.W/ + (01:18:08, 17 December 2024)
- 05000361/LER-1982-064-03, /03L-0:on 820716,containment Personnel Access Airlock Jammed in Open Position.Caused by Linkage Maladjustment Due to Heavy Personnel Traffic Associated W/Plant Startup Between Initial Fuel Load & Criticality + (01:18:10, 17 December 2024)
- 05000277/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl + (01:18:11, 17 December 2024)
- ML20064M776 + (01:18:12, 17 December 2024)
- 05000416/LER-1983-005-03, /03L-0:on 830111,fire Door OR106 Blocked Opened to Allow Transport of Resin.Fire Watch Established Per Tech Specs.Door Closed When Job Completed on 830112 + (01:18:13, 17 December 2024)
- ML20064M769 + (01:18:14, 17 December 2024)
- ML20064M767 + (01:18:15, 17 December 2024)
- ML20064M766 + (01:18:16, 17 December 2024)
- ML20064M765 + (01:18:16, 17 December 2024)
- ML20064M764 + (01:18:17, 17 December 2024)
- ML20064M758 + (01:18:17, 17 December 2024)
- ML20064M757 + (01:18:18, 17 December 2024)
- 05000416/LER-1983-005, Forwards LER 83-005/03L-0 + (01:18:19, 17 December 2024)
- BSEP-94-0116, Forwards Response to Violations Noted in Insp Repts 50-324/94-01 & 50-325/94-01.Corrective Actions:Comprehensive Task List Will Be Developed for Unit 2 Vessel Reassembly Currently Scheduled for 940604 + (01:18:19, 17 December 2024)
- ML20064M747 + (01:18:20, 17 December 2024)
- ML20064M752 + (01:18:20, 17 December 2024)
- 05000361/LER-1982-076, Forwards LER 82-076/03L-0.Detailed Event Analysis Submitted + (01:18:21, 17 December 2024)
- ML20064M742 + (01:18:22, 17 December 2024)
- ML20064M744 + (01:18:22, 17 December 2024)
- ML20064M741 + (01:18:23, 17 December 2024)
- BSEP-94-0108, Application for Amends to Licenses DPR-71 & DPR-62, Correcting Typographical Errors & Incorporating Matl Implicitly Contained in Footnote to Applicability Statement, Providing Detailed Labels for Items Listed in Table + (01:18:24, 17 December 2024)
- ML20064M738 + (01:18:24, 17 December 2024)
- ML20064M735 + (01:18:25, 17 December 2024)
- ML20064M733 + (01:18:26, 17 December 2024)
- ML20064M730 + (01:18:27, 17 December 2024)
- ML20064M731 + (01:18:27, 17 December 2024)
- ML20064M729 + (01:18:28, 17 December 2024)
- 05000395/LER-1983-003-03, /03L-0:on 830108 & 20,main Control Board Indication for Steam Generator a Feedwater Flow IFI-477 Failed Low.Caused by High Instrument Cabinet Temp.Power Supply Card Replaced & Recalibr + (01:18:29, 17 December 2024)
- ML20064M724 + (01:18:34, 17 December 2024)
- A16402, Irradiation-Induced Creep in Graphite:Review + (01:18:35, 17 December 2024)
- ML20064M720 + (01:18:36, 17 December 2024)
- 05000361/LER-1982-064, Forwards LER 82-064/03L-0.Detailed Event Analysis Submitted + (01:18:37, 17 December 2024)
- ML20064M709 + (01:18:37, 17 December 2024)