- 05000278/LER-1982-024-03, /03L-0:on 821209,fire Alarm Received from Core Spray Pump Rooms B & D & RHR Pump Room C.Caused by Reversed Wiring in B & D Core Spray & RHR Pump Room C.Wiring Corrected + (14:15:15, 16 December 2024)
- ML20070Q456 + (14:15:17, 16 December 2024)
- 05000327/LER-1982-143, Forwards LER 82-143/03L-0 + (14:15:18, 16 December 2024)
- 05000335/LER-1982-064-03, /03L-0:on 821216,w/B Charging Pump Out of Svc for Maint,Control Room Received Charging Pump 1A Safety Injection Actuation Signal Autostart Failure Alarm.Alarm Cleared & Did Not Restart.Caused by Misadjustment + (14:15:19, 16 December 2024)
- ML20070Q441 + (14:15:21, 16 December 2024)
- ML20070Q433 + (14:15:22, 16 December 2024)
- 05000339/LER-1982-086-03, /03L-0:on 821221,outside & Inside Containment Isolation Valves in Steam Generator Wet Layup Sys Found Open,Unlocked & Unattended.Caused by Procedural Inadequacy. Valves Locked & Containment Integrity Checklist Revised + (14:15:24, 16 December 2024)
- ML20070Q429 + (14:15:25, 16 December 2024)
- 05000277/LER-1982-042-03, /03L-0:on 821210,while Performing Snubber Surveillance Test,Feedwater Snubber & HPCI Exhaust Line Snubber Discovered Detached.Caused by Improper Installation. Snubbers Properly Reinstalled + (14:15:27, 16 December 2024)
- 05000335/LER-1982-064, Forwards LER 82-064/03L-0 + (14:15:28, 16 December 2024)
- ML20070Q404 + (14:15:28, 16 December 2024)
- 05000339/LER-1982-086, Forwards LER 82-086/03L-0 + (14:15:29, 16 December 2024)
- ML20070Q368 + (14:15:30, 16 December 2024)
- ML20070Q358 + (14:15:32, 16 December 2024)
- ML20070Q340 + (14:15:33, 16 December 2024)
- ML20070Q347 + (14:15:33, 16 December 2024)
- HL-1542, Special Rept:On 910301,battery-powered Emergency Lighting Units Inoperable for Period Greater than 72 H.Caused by Personnel Error.Units Restored to Operable Status on 910302 & Surveillance Procedure 42SV-FPX-003-0S Revised + (14:15:34, 16 December 2024)
- ML20070Q334 + (14:15:34, 16 December 2024)
- 05000321/LER-1991-006-01, :on 910225,unplanned ESF Actuation Occurred. Caused by Personnel Error.Counseling of Involved Personnel, Surveillance Procedure & Verifying That Surveillance Results Were Satisfactory Initiated + (14:15:36, 16 December 2024)
- NRC-94-4120, Rev 0 to in Situ Check Valve Test Rept (Fall Outage 93) + (14:15:37, 16 December 2024)
- 05000416/LER-1982-174-03, /03L-0:on 821227,diesel Generator 12 & Div 2 ECCS Declared Inoperable Due to Diesel Generator Failure to Start Alarm.Caused by Failed Circuit Card.New Card Installed in Local Annunciator Panel & Failed Card Repaired + (14:15:39, 16 December 2024)
- 05000395/LER-1982-061-03, /03L-0:on 821218,diesel Generator B (XEG001B) Failed Monthly Operability Test by Tripping on Low Lube Oil Pressure.Cause Unknown.Diesel Generator B Satisfactorily Restarted within 30 Minutes + (14:15:41, 16 December 2024)
- 05000498/LER-1991-006, :on 910224,class 1E 120 Volt AC Distribution Panel Energized by Alternate Power Source Violating Tech Spec.Caused by Personnel Error.Reactor Operator Counseled Re Event + (14:15:43, 16 December 2024)
- 05000271/LER-1991-003, :on 910227,missed Diesel Fire Pump Fuel Oil Surveillance.Caused by Inadequate Procedure.Review of Chemistry Dept Tech Spec Surveillances & Training for All Chemistry Dept Personnel Being Performed + (14:15:45, 16 December 2024)
- ML20070Q283 + (14:15:46, 16 December 2024)
- 05000395/LER-1991-001, :on 910219,missed Surveillance for Axial Flux Difference.Caused by Personnel Error.Review Made of Two Computer Generated Alarms Required by Tech Spec & Software Changes Made to Eliminate Synchronization + (14:15:48, 16 December 2024)
- ML20070Q276 + (14:15:49, 16 December 2024)
- 05000278/LER-1991-003-02, :on 910225,high Pressure Coolant Injection Sys Inoperable.Caused by Inadequate Procedure.Weekly Surveillance Revised & New Design to Replace Existing Tappet Assembly + (14:15:50, 16 December 2024)
- ML20070Q271 + (14:15:51, 16 December 2024)
- ML20070Q265 + (14:15:52, 16 December 2024)
- 05000416/LER-1983-003-01, /01T-0:on 830108,limiting Condition for Operation Entered Due to Intermediate Range Monitor Functional Test Not Being Performed within Required Time Period.Caused by Personnel Error.Personnel Made Aware of Error + (14:15:54, 16 December 2024)
- ML20070Q247 + (14:15:55, 16 December 2024)
- ML20070Q244 + (14:15:56, 16 December 2024)
- TXX-9107, Forwards Info on Re Auxiliary Feedwater Sys Check Valves Causing Overheating & Provides Update Re Completed & Planned Actions + (14:15:57, 16 December 2024)
- ML20070Q235 + (14:15:58, 16 December 2024)
- ML20070Q231 + (14:15:59, 16 December 2024)
- ML20070Q230 + (14:16:00, 16 December 2024)
- ML20070Q228 + (14:16:00, 16 December 2024)
- ML20070Q225 + (14:16:01, 16 December 2024)
- 05000395/LER-1982-061, Forwards LER 82-061/03L-0.Detailed Event Analysis Encl + (14:16:02, 16 December 2024)
- ML20070Q220 + (14:16:02, 16 December 2024)
- ST-HL-AE-3727, Forwards Response to Inadequacy & Concerns Identified During Regulatory Effectiveness Review Conducted at Plant from 910107-10.Response Withheld + (14:16:03, 16 December 2024)
- ML20070Q211 + (14:16:03, 16 December 2024)
- ML20070Q202 + (14:16:04, 16 December 2024)
- ML20070Q191 + (14:16:05, 16 December 2024)
- ML20070Q184 + (14:16:09, 16 December 2024)
- ML20070Q181 + (14:16:10, 16 December 2024)
- ML20070Q178 + (14:16:10, 16 December 2024)
- ML20070Q177 + (14:16:11, 16 December 2024)
- SNRC-1803, Requests Extension Until 910411 to Respond to NRC 910226 Request for Info Re Accumulation of Funds for Decommissioning + (14:16:12, 16 December 2024)
- SNRC-1800, Forwards Rev to Environ Protection Plan Submitted in 900105 Application for possession-only License,Reflecting Defueled Status of Facility + (14:16:13, 16 December 2024)