- ML20071G684 + (11:37:25, 15 December 2024)
- 05000301/LER-1983-006-03, /03L-0:on 830419,time Delay Setpoint of Contact from Time Delay Relay 2-TDRC/A06 & 4,160-volt Degraded Grid Voltage Relay 2-275/A06 Set Above Tech Spec Limit.Caused by Bumping or Mispositioning Time Set Knob + (11:37:27, 15 December 2024)
- 05000315/LER-1983-035-03, /03L-0:on 830414,deluge Valves for Instrument Room Purge Exhaust 1-HV-CIPX-1 & Control Room Cleanup Sys 1-HV-ACRF-1 Would Not Open Upon Actuation Signal.Caused by Failure of Time Delay Circuit Boards + (11:37:28, 15 December 2024)
- 05000315/LER-1983-034-03, /03L-0:on 830413,pyralarm Detector Alarmed & Found Unplugged,Rendering Fire Zone 4 Detectors Inoperable.Caused by Failure to Plug in Alarm After Conduit Installation. Pyralarm Reinstalled & Sys Verified Operable + (11:37:30, 15 December 2024)
- 05000285/LER-1979-015-01, /01T-0 on 790511:seismic Support Appeared Inadequate for Component Cooling Water piping-to-containment Cooling & Filtering Unit VA-3A.Analyses Indicated That Clamping piping-to-cooling Unit Will Provide Needed Support + (11:37:32, 15 December 2024)
- 05000285/LER-1979-015, Forwards LER 79-015/01T-0 + (11:37:33, 15 December 2024)
- ML20071G667 + (11:37:34, 15 December 2024)
- ML20071G665 + (11:37:34, 15 December 2024)
- 05000254/LER-1983-018-03, /03L-0:on 830412,excessively High Discharge Pressure & Low Flow Observed from RHR Svc Water Pump 1-1001-65C.Caused by anti-rotation Pin Falling Out of Valve Operator.Pin Replaced & Screw Tightened + (11:37:36, 15 December 2024)
- ML20071G660 + (11:37:37, 15 December 2024)
- 05000373/LER-1983-036-03, /03L-0:on 830414,welding Procedures Wps 1-5-A & 5-5-A Discovered in Conflict W/Asme Code.Repairs to Main Steam Drain Line Welds Made Using Subj Procedures.Evaluation of Procedures in Process + (11:37:38, 15 December 2024)
- 05000254/LER-1983-017-03, /03L-0:on 830412,RHR Svc Water Pump 1-1001-65C Taken Out of Svc to Facilitate Repair of Broken Coupling on RHR Svc Water Vault Room Cooler 1-5745-C Drain Line.Caused by Overpressurization of Piping + (11:37:40, 15 December 2024)
- ML20071G654 + (11:37:41, 15 December 2024)
- ML20071G650 + (11:37:42, 15 December 2024)
- ML20071G643 + (11:37:42, 15 December 2024)
- ML20071G640 + (11:37:43, 15 December 2024)
- ML20071G606 + (11:37:43, 15 December 2024)
- ML20071G599 + (11:37:44, 15 December 2024)
- ML20071G587 + (11:37:45, 15 December 2024)
- ML20071G573 + (11:37:45, 15 December 2024)
- ML20071G566 + (11:37:46, 15 December 2024)
- ML20071G570 + (11:37:46, 15 December 2024)
- ML20071G551 + (11:37:47, 15 December 2024)
- ML20071G564 + (11:37:47, 15 December 2024)
- ML20071G534 + (11:37:48, 15 December 2024)
- ML20071G522 + (11:37:49, 15 December 2024)
- ML20071G516 + (11:37:50, 15 December 2024)
- ML20071G519 + (11:37:50, 15 December 2024)
- ML20071G515 + (11:37:51, 15 December 2024)
- ML20071G513 + (11:37:51, 15 December 2024)
- NRC-2019-0241, Declaration of Authorized Officer of Citizenss Resistance at Ferm 2 (Craft) to File as Pro Se Counsel + (11:37:52, 15 December 2024)
- ML20071G507 + (11:37:55, 15 December 2024)
- ML20071G504 + (11:37:56, 15 December 2024)
- ML20071G500 + (11:37:57, 15 December 2024)
- ML20071G501 + (11:37:57, 15 December 2024)
- ML20071G496 + (11:37:58, 15 December 2024)
- ML20071G491 + (11:37:59, 15 December 2024)
- ML20071G486 + (11:38:00, 15 December 2024)
- 05000331/LER-1983-010-03, /03L-0:on 830411,during Refueling Outage,One Snubber Found Inoperable,One Indeterminant,One Had Missing Bushing & One W/Bushing Disengaged.Caused by Procedure Error During Previous Maint + (11:38:02, 15 December 2024)
- ML20071G463 + (11:38:03, 15 December 2024)
- 05000373/LER-1983-038-03, /03L-0:on 830207,during Performance of LIS-HP-09, Head Correction Omitted from Calibr Test Pressure,Leaving Instrument 1E22-N013 Out of Tolerance.Caused by Misunderstanding of Procedures + (11:38:04, 15 December 2024)
- ML20071G457 + (11:38:05, 15 December 2024)
- ML20071G451 + (11:38:06, 15 December 2024)
- 05000331/LER-1983-012-01, /01T-0:on 830425,full Scram Should Have Been Received When Mode Switch Moved from Refuel to Shutdown, However,Sys a Did Not Trip.Caused by Faulty Solder Connection on Rectifier.Connections Resoldered + (11:38:07, 15 December 2024)
- ML20071G446 + (11:38:08, 15 December 2024)
- 05000346/LER-1983-017-03, /03L-0:on 830411,spent Fuel Pool (SFP) Level Verification Surveillance Test Ordered Later than Tech Spec Requirement.Caused by Personnel Error.Sfp Level Verified. Memo on Schedules Planned + (11:38:10, 15 December 2024)