Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- NG-94-3152, Forwards Response to Requests for Info in GL 94-02, Long- Term Solutions & Upgrade of Interim Operating Recommendations for Thermal-Hydraulic Instabilities in Bwrs + (09:14:35, 15 December 2024)
- 05000219/LER-1983-011, Forwards LER 83-011/03L-0.Detailed Event Analysis Encl + (09:14:36, 15 December 2024)
- ML20072U293 + (09:14:37, 15 December 2024)
- ML20072U292 + (09:14:37, 15 December 2024)
- AECM-83-0215, Seventh Interim Deficiency Rept PRD-81/44 Re Valves & Actuators Not Mfg Under QA Program.Initially Reported on 811029.Actuators & Appurtenances Not Mfg Under QA Program Qualified by Tests.Final Rept Expected by 830708 + (09:14:38, 15 December 2024)
- ML20072U275 + (09:14:39, 15 December 2024)
- ML20072U276 + (09:14:39, 15 December 2024)
- ML20072U271 + (09:14:40, 15 December 2024)
- ML20072U264 + (09:14:41, 15 December 2024)
- ML20072U259 + (09:14:42, 15 December 2024)
- ML20072U256 + (09:14:43, 15 December 2024)
- ML20072U248 + (09:14:44, 15 December 2024)
- ML20072U246 + (09:14:45, 15 December 2024)
- ML20072U237 + (09:14:46, 15 December 2024)
- ML20072U241 + (09:14:46, 15 December 2024)
- ML20072U228 + (09:14:47, 15 December 2024)
- ML20072U227 + (09:14:48, 15 December 2024)
- ML20072U222 + (09:14:49, 15 December 2024)
- ML20072U221 + (09:14:50, 15 December 2024)
- ML20072U217 + (09:14:51, 15 December 2024)
- ML20072U214 + (09:14:52, 15 December 2024)
- ML20072U216 + (09:14:52, 15 December 2024)
- ML20072U204 + (09:14:53, 15 December 2024)
- ML20072U212 + (09:14:53, 15 December 2024)
- ML20072U202 + (09:14:54, 15 December 2024)
- ML20072U201 + (09:14:55, 15 December 2024)
- ML20072U200 + (09:14:56, 15 December 2024)
- ML20072U199 + (09:14:56, 15 December 2024)
- ML20072U195 + (09:14:57, 15 December 2024)
- ML20072U192 + (09:14:58, 15 December 2024)
- 05000278/LER-1983-010-03, /03L-0:on 830222,during Refueling Outage,Testing of Recently Installed Fire Detection Sys Mod Revealed Previously Undetected Wiring Errors Between Two Sets of Two Annunciator Circuits.Caused by Wiring Error + (09:15:00, 15 December 2024)
- ML20072U190 + (09:15:01, 15 December 2024)
- ML20072U187 + (09:15:02, 15 December 2024)
- ML20072U183 + (09:15:03, 15 December 2024)
- ML20072U179 + (09:15:03, 15 December 2024)
- ML20072U177 + (09:15:04, 15 December 2024)
- ML20072U169 + (09:15:05, 15 December 2024)
- ML20072U164 + (09:15:06, 15 December 2024)
- 05000315/LER-1983-021-03, /03L-0:on 830304,612-ft Elevation Containment Air Lock Interlock Found Inoperable.Caused by out-of-adjustment Cable.Cable Adjusted + (09:15:07, 15 December 2024)
- 05000315/LER-1983-020-03, /03L-0:on 830306,control Room Access Fire Door 412 Would Not Operate Properly.Caused by Extension Rod Pulling Loose from Door Frame Shoe.Shoe Setscrews & Rod Replaced + (09:15:09, 15 December 2024)
- ML20072U145 + (09:15:11, 15 December 2024)
- 05000361/LER-1983-027-03, /03L-0:on 830224,during Mode 5,control Bldg Lobby Door C3-63 Found Unlatched & Subsequent Attempts at Latching Failed.Caused by Excessive Use.Emergency Maint Performed on Latch Per Special Order 83-18 + (09:15:12, 15 December 2024)
- 05000315/LER-1983-019-03, /03L-0:on 830313,612-ft Elevation Containment Air Lock Interlock Found Inoperable.Caused by out-of-adjustment Cable.Cable Adjusted + (09:15:14, 15 December 2024)
- 05000361/LER-1983-020-03, /03L-0:on 830224,during Mode 5,latch for Door C3-67 Between Control Room & Cable Riser Gallery Discovered Jamming.Caused by Excessive Use.Emergency Maint Performed Per Special Order 83-18 + (09:15:16, 15 December 2024)
- ML20072U125 + (09:15:17, 15 December 2024)
- 05000315/LER-1983-018-03, /03L-0:on 830303,upper Containment Personnel Air Lock Door Leakage Rate Found Excessive.Caused by Dirt & Tape Affixed to Outer Door Seals During Equipment Installation. Dirt & Tape Removed + (09:15:18, 15 December 2024)
- BECO-LTR-94-096, Forwards Comments on NRC Preliminary Accident Sequence Precursor Analysis (ASP) of Events on 930531 & 0910. Recommends Comments Also Be Used for Other Pilgrim Events That May Be Under Consideration as Preliminary ASPs + (09:15:19, 15 December 2024)
- 05000318/LER-1994-004-01, :on 940810,experienced Reactor Trip Due to Main Generator Trip.Caused by Loss of Field Relay.Replacement of Failed Components Completed & Refresher Training Provided for Operators + (09:15:21, 15 December 2024)
- ML20072U107 + (09:15:22, 15 December 2024)
- 05000315/LER-1983-017-03, /03L-0:on 830303,excessive Leakage Rates Noted at Upper & Lower Containment Personnel Air Lock Doors.Caused by Personnel Not Removing Grease Fittings After Lubrication. Fittings Replaced + (09:15:24, 15 December 2024)
- ML20072U105 + (09:15:25, 15 December 2024)
- ML20072U104 + (09:15:26, 15 December 2024)