- NLS9100418, Forwards Results of Independent Audit of Decommissioning Trust Fund for Yr Ending 901231,including Statement of Assets & Fund Balance,Statement of Changes in Fund Balance & Schedule of Investments + (12:37:57, 14 December 2024)
- 05000369/LER-1983-093-03, /03L-0:on 830926,Fire Door 819A Found Attached to Door Frame by Top Hinge & Door Closer Mechanism Only.Caused by Damage to Threads of Screw Holes.Screw Holes Retopped & New Screws Installed + (12:37:59, 14 December 2024)
- ML20081M509 + (12:38:00, 14 December 2024)
- ML20081M508 + (12:38:01, 14 December 2024)
- 05000328/LER-1983-133-03, /03L-0:on 831012,auxiliary Feedwater Pump Declared Inoperable Due to Failure of Automatic Control Valve 2-LCV-3-156 to Open on Demand.Caused by Incorrect Air Pressure Supply Regulator Setting + (12:38:03, 14 December 2024)
- 05000327/LER-1983-138-03, /03L-0:on 831013,containment Isolation Valve 1-FCV-43-64,steam Generator Blowdown Sample Isolation Valve,Discovered Leaking.Caused by Broken Bellows.Bellows & Bonnet Assembly Replaced + (12:38:05, 14 December 2024)
- ML20081M503 + (12:38:06, 14 December 2024)
- 05000373/LER-1983-121-03, /03L-0:on 831014,while Performing LOS-AA-W1, Control Rod Drive at Core Location 30-19 Indicated Overtravel When Withdrawn to Full Out Position.Caused by Excessive Crud Buildup on Filter + (12:38:07, 14 December 2024)
- NLS9100416, Rev to 910425 Application for Amend to License DPR-46, Consisting of Updated Tech Spec Page for Proposed Change 79 Re Reactor Water Level 3 Setpoint & Incorporates Changes to License Through Amend 142 Issued 910522 + (12:38:08, 14 December 2024)
- ML20081M492 + (12:38:09, 14 December 2024)
- 05000328/LER-1983-146-03, /03L-0:on 831012,pressurizer Level Channels 2-LT-68-320 & 2-LT-68-335 Found Out of Calibr During Refueling Operations.Probably Caused by Instrument Drift. Transmitter Recalibr & Returned to Svc + (12:38:11, 14 December 2024)
- 05000366/LER-1983-109-03, /03L-0:on 831019,drywell Vent & Purge Isolation Valve 2T48-F340 Gave Double Position Indication & Declared Inoperable.Caused by Unadjusted Closed Position Switch. Switch Adjusted + (12:38:13, 14 December 2024)
- ML20081M485 + (12:38:14, 14 December 2024)
- PLA-1891, Monthly Operating Rept for Sept 1983 + (12:38:15, 14 December 2024)
- 05000280/LER-1983-045-03, /03L-0:on 831010 & 17,core Cooling Monitor a Declared Inoperable Following Erratic Indication.Cause of 831010 Event Not Determined.Event on 831017 Caused by Bad Connector in Power Supply.Supply Replaced + (12:38:17, 14 December 2024)
- ML20081M471 + (12:38:18, 14 December 2024)
- ML20081M469 + (12:38:18, 14 December 2024)
- ML20081M466 + (12:38:19, 14 December 2024)
- 05000321/LER-1981-112-03, Torus to Rx Bldg Differential Pressure Switches 1T48-N210,N211,2T48-N210 & N211 Proof Press Not within Tech Spec Limit.Caused by Switch Misapplication.Also Reported Per Part 21 + (12:38:21, 14 December 2024)
- AECM-83-0699, RO 83-095/0:on 830926,fire-rated Assembly Penetrations AE53D & AE590D Discovered Open.Penetrations Not Listed on Schedule.Fire Watch Established Until Penetrations Sealed. Sealing Completion Expected by 831230 + (12:38:22, 14 December 2024)
- BSEP-83-3540, RO 2-83-84:on 830930,determined Rod Worth Minimizer Inoperable Due to Sequencing Overlap.Further Evaluation Concluded Event Not Reportable.Deletion of LER 2-83-84 Requested + (12:38:22, 14 December 2024)
- 05000281/LER-1983-047-03, /03L-0:on 831005 & 23,w/unit at 100%,pump 2-RS-P-2A Tripped on Overload During Monthly Surveillance Tests,Contrary to Tech Spec 3.4.A.2.Caused by Instantaneous Trip Set Below Specs.Overload Setting Adjusted + (12:38:27, 14 December 2024)
- ML20081M434 + (12:38:28, 14 December 2024)
- ML20081M425 + (12:38:29, 14 December 2024)
- ML20081M428 + (12:38:29, 14 December 2024)
- AECM-83-0717, RO 83-097/0:on 831003,auxiliary Bldg Steam Line Tunnel Temps Exceeded Tech Spec 3.7.8 Limit.Analysis to Demonstrate Continued Operability in Progress.Update Rept Expected by 831120 + (12:38:30, 14 December 2024)
- 2CAN108308, Monthly Operating Rept for Sept 1983 + (12:38:31, 14 December 2024)
- ML20081M417 + (12:38:31, 14 December 2024)
- 05000324/LER-1983-074-03, /03L-0:on 831006,reactor Recirculation Pump 2A Tripped Due to Motor Generator Set High Fluid Drive Temp. Caused by Slight Mechanical Shock of Motor Generator Set Fluid Drive High Temp Trip Device + (12:38:33, 14 December 2024)
- ML20081M373 + (12:38:34, 14 December 2024)
- ML20081M375 + (12:38:34, 14 December 2024)
- 05000289/LER-1983-033-03, /03L-0:on 830928,reactor Bldg High Pressure Switch Setpoint on Reactor Protective Sys Channel a Found Less Conservative than Tech Spec Limit.Caused by Setpoint Drift. Switch Recalibr + (12:38:36, 14 December 2024)
- ML20081M365 + (12:38:37, 14 December 2024)
- 05000387/LER-1983-143-03, /03L-0:on 830929,following Replacement of Common Inlet Filter for Reactor Bldg Zone III Refueling Floor Supply Fans,Fans Tripped After Starting.Caused by Low Flow Signals Due to Failure to Adjust Inlet Damper + (12:38:39, 14 December 2024)
- ML20081M357 + (12:38:41, 14 December 2024)
- ML20081M346 + (12:38:42, 14 December 2024)
- 05000321/LER-1983-102-03, /03L-0:on 831011,standby Liquid Relief Valve C41-F029A Declared Inoprable.Caused by Valve Failure.All Internal Parts Cleaned,Reassembled W/New Gaskets & Reinstalled.Valve Adjusted & Returned to Svc + (12:38:43, 14 December 2024)
- ML20081M342 + (12:38:51, 14 December 2024)
- ML20081M338 + (12:38:52, 14 December 2024)
- ML20081M334 + (12:38:53, 14 December 2024)
- ML20081M336 + (12:38:53, 14 December 2024)
- ML20081M328 + (12:38:54, 14 December 2024)
- ML20081M326 + (12:38:55, 14 December 2024)
- 1CAN108303, Monthly Operating Rept for Sept 1983 + (12:38:56, 14 December 2024)
- ML20081M318 + (12:38:56, 14 December 2024)
- ML20081M308 + (12:38:58, 14 December 2024)
- ML20081M304 + (12:38:59, 14 December 2024)
- ML20081M294 + (12:39:01, 14 December 2024)
- ML20081M285 + (12:39:02, 14 December 2024)
- AECM-83-0724, Forwards Partial Response to Request for Addl Info Re Transamerica Delaval,Inc Diesel Generators Supplied to Facility.Steps Taken to Obtain More Detailed Info on Crankshaft Design Analyses & Testing Done by Lilco + (12:39:04, 14 December 2024)
- ML20081M221 + (12:39:34, 14 December 2024)
- ML20081M223 + (12:39:34, 14 December 2024)