- 05000254/LER-1983-040-03, /03L-0:on 831019,11 Instances of Weekly Surveillance Not Performed Identified within Surveillance Interval.Caused by Personnel Error.Shift Engineers Assured Full Compliance for Future Surveillances + (11:59:21, 14 December 2024)
- ML20082J546 + (11:59:22, 14 December 2024)
- ML20082J543 + (11:59:22, 14 December 2024)
- 05000254/LER-1983-042-03, /03L-0:on 831024,station Diesel Fire Pump 1/2A Made Inoperable When Diesel Failed to Start on Battery Bank A.Caused by Battery end-of-life.New Battery Installed + (11:59:25, 14 December 2024)
- 05000373/LER-1983-126-03, /03L-0:on 831027,control Rod Drive at Core Location 30-19 Indicated Overtravel When Withdrawn to Full Out Position During Unit Startup.Caused by Inner Filter Retainer Spring Damage Due to Crud Buildup + (11:59:27, 14 December 2024)
- ML20082J527 + (11:59:28, 14 December 2024)
- LIC-95-0087, Monthly Operating Rept for Mar 1995 for FCS + (11:59:29, 14 December 2024)
- ML20082J524 + (11:59:29, 14 December 2024)
- 05000373/LER-1983-133-03, /03L-0:on 831024,both Personnel Access Doors Opened at Same Time for About 90 S,Allowing Personnel to Exit Drywell.Personnel Could Not Open Outer Airlock Door Due to Slipped Cam.Caused by Two Loose Screws + (11:59:31, 14 December 2024)
- ML20082J509 + (11:59:32, 14 December 2024)
- ML20082J507 + (11:59:33, 14 December 2024)
- ML20082J508 + (11:59:33, 14 December 2024)
- ML20082J501 + (11:59:34, 14 December 2024)
- ML20082J494 + (11:59:34, 14 December 2024)
- ML20082J486 + (11:59:35, 14 December 2024)
- ML20082J488 + (11:59:35, 14 December 2024)
- ML20082J483 + (11:59:36, 14 December 2024)
- ML20082J474 + (11:59:37, 14 December 2024)
- ML20082J470 + (11:59:37, 14 December 2024)
- ML20082J456 + (11:59:38, 14 December 2024)
- ML20082J459 + (11:59:38, 14 December 2024)
- ML20082J445 + (11:59:39, 14 December 2024)
- ML20082J441 + (11:59:40, 14 December 2024)
- ML20082J426 + (11:59:40, 14 December 2024)
- ML20082J423 + (11:59:41, 14 December 2024)
- ML20082J422 + (11:59:42, 14 December 2024)
- ML20082J413 + (11:59:43, 14 December 2024)
- ML20082J407 + (11:59:43, 14 December 2024)
- ML20082J400 + (11:59:44, 14 December 2024)
- ML20082J397 + (11:59:45, 14 December 2024)
- 05000373/LER-1983-132-03, /03L-0:on 831020,HPCS Diesel Air Start Storage Tank Air Pressure Dropped Below Tech Specs & Declared Inoperable.Caused by Air Compressor Failure Due to first- Stage Relief Valve Lifting.Compressor Repaired + (11:59:46, 14 December 2024)
- ML20082J385 + (11:59:47, 14 December 2024)
- ML20082J384 + (11:59:48, 14 December 2024)
- ML20082J378 + (11:59:50, 14 December 2024)
- ML20082J374 + (11:59:51, 14 December 2024)
- ML20082J372 + (11:59:51, 14 December 2024)
- ML20082J368 + (11:59:52, 14 December 2024)
- 05000263/LER-1983-023-03, /03L-0:on 831026,flow Through Train B Standby Gas Treatment Less than Tech Spec Requirement.Caused by Stack Exhaust Flow Incorrectly Adjusted.Stack Flow Corrected + (11:59:54, 14 December 2024)
- ML20082J353 + (11:59:55, 14 December 2024)
- PY-CEI-NRR-0082, Responds to IE Bulletin 83-06 Re Nonconforming Matls Supplied by Tube-Line Corp.Facility Does Not Possess Any Tube-Line Matl Described in Bulletin + (11:59:55, 14 December 2024)
- ML20082J347 + (11:59:56, 14 December 2024)
- ML20082J340 + (11:59:56, 14 December 2024)
- NG-83-3907, Responds to IE Bulletin 83-06 Re Tube-Line Corp Supplies. Documentation Review Revealed Tube-Line Products Not Received at Plant + (11:59:57, 14 December 2024)
- ML20082J336 + (11:59:58, 14 December 2024)
- 05000249/LER-1983-040-03, /03L-0:on 831028,diesel Generator Did Not Close Onto 4-kV Bus 34-1 & Feed Breaker Remained Tripped.Caused by Dirt Buildup on Contact 52H on Bus.Contact Burnished + (11:59:59, 14 December 2024)
- ML20082J331 + (12:00:03, 14 December 2024)
- ML20082J325 + (12:00:04, 14 December 2024)
- ML20082J323 + (12:00:05, 14 December 2024)
- 05000373/LER-1983-131-03, /03L-0:on 831019,reactor Recirculation Sys Jet Pumps Did Not Meet Tech Spec Operability Criteria.Caused by Use of Data Obtained from Test Condition 3 Rather than Test Condition 6.Pumps Retested W/Proper Data + (12:00:07, 14 December 2024)
- ML20082J317 + (12:00:08, 14 December 2024)
- 05000306/LER-1983-026-03, /03L-0:on 831021,sodium Hydroxide Concentration of 11.5% in Spray Additive Tank Exceeded Tech Spec Limit of 11%.Caused by Inadequate Mixing for Design Change.Tank Refilled.Solution Diluted & Recirculated + (12:00:10, 14 December 2024)
- ML20082J309 + (12:00:11, 14 December 2024)