- ML20082U032 + (11:21:24, 14 December 2024)
- ML20082U016 + (11:21:25, 14 December 2024)
- ML20082U031 + (11:21:25, 14 December 2024)
- JAFP-91-0578, Responds to NRC Re Violations Noted in Insp Rept 50-333/91-08 on 910425-0503.Corrective Actions:Maint Dept Established Time Goal & Instrument & Control Dept Reviewed Procedures + (11:21:26, 14 December 2024)
- ML20082U015 + (11:21:26, 14 December 2024)
- ML20082U012 + (11:21:27, 14 December 2024)
- NRC-91-0109, Responds to NRC Re Violations Noted in Insp Rept 50-341/91-15.Corrective Actions:Memo Issued to All Site Personnel Re Operating Authority Notification Prior to Opening Energized Cabinet + (11:21:28, 14 December 2024)
- ML20082U002 + (11:21:28, 14 December 2024)
- ML20082U000 + (11:21:29, 14 December 2024)
- ML20082T999 + (11:21:30, 14 December 2024)
- ML20082T996 + (11:21:30, 14 December 2024)
- 05000265/LER-1991-009-03, :on 910817,Tech Spec 3.5.A.6 Entered Due to Core Spray Room Check Valves 2A & 2B Leaking by & Failing Quarterly Surveillance Testing.Caused by Foreign Matl Lodged in Valves.Drain Line Plugs Installed + (11:21:32, 14 December 2024)
- ML20082T988 + (11:21:33, 14 December 2024)
- ML20082T975 + (11:21:34, 14 December 2024)
- ML20082T974 + (11:21:34, 14 December 2024)
- ML20082T970 + (11:21:35, 14 December 2024)
- ML20082T953 + (11:21:36, 14 December 2024)
- BECO-95-027, Marine Ecology Studies Re Operation of Pilgrim Station Semiannual Rept 45 Jan-Dec 1994 + (11:21:37, 14 December 2024)
- ML20082T947 + (11:21:37, 14 December 2024)
- 05000260/LER-1983-072-03, /03L-0:on 831108,during Performance of High Flow Steam Line Calibr Functional test,Pdis-1-36B,1-13B & 1-050B Experienced Setpoint Drift.Barton Model 278 Pressure Switches Also Experienced Setpoint Drift + (11:21:39, 14 December 2024)
- ML20082T938 + (11:21:40, 14 December 2024)
- 05000370/LER-1983-075-03, /03L-0:on 831027,during Performance of Isolation Valve Leak Rate Testing,Mechanical Penetration M456 Failed to Meet Leakage Criteria.Caused by Design Deficiency Due to Poor Valve sealing.T-ring Adjusted + (11:21:43, 14 December 2024)
- ML20082T922 + (11:21:47, 14 December 2024)
- AECM-83-0780, RO 83-107/0:on 831101,Fire-Rated Door OC501 Inoperable. Latching Mechanism on Door Damaged as Result of Heavy Use. Fire Watch Established.Repairs Expected to Be Complete by 840315 + (11:21:48, 14 December 2024)
- ML20082T917 + (11:21:48, 14 December 2024)
- 05000366/LER-1983-127-03, /03L-0:on 831108,sump Discharge Valve 2G11-F018 Would Not Open.Caused by Blown Fuse in Valve Control Circuit.Fuse Replaced.W/Undated Ltr + (11:21:50, 14 December 2024)
- ML20082T902 + (11:21:51, 14 December 2024)
- ML20082T903 + (11:21:51, 14 December 2024)
- ML20082T899 + (11:21:52, 14 December 2024)
- ML20082T891 + (11:21:53, 14 December 2024)
- ML20082T875 + (11:21:54, 14 December 2024)
- ML20082T858 + (11:21:55, 14 December 2024)
- 05000370/LER-1983-062-03, /03L-0:on 831015,during Rapid Power Reduction Due to Problems W/Steam Generator Feedwater Isolation Valve,Rcs Average Temp Fell Below Min Temp for Criticality.Caused by Excessive Boration of RCS by Control Operator + (11:21:56, 14 December 2024)
- ML20082T822 + (11:21:57, 14 December 2024)
- ML20082T815 + (11:21:58, 14 December 2024)
- ML20082T821 + (11:21:58, 14 December 2024)
- ML20082T792 + (11:21:59, 14 December 2024)
- BSEP-83-3846, Advises That LER 1-83-28 Has Been Canceled + (11:22:00, 14 December 2024)
- NLS9100483, Forwards Rev 4 to Emergency Plan for Facility.W/O Encl + (11:22:00, 14 December 2024)
- 2CAN118303, Forwards Responses to SER Re Inadequate Core Cooling (NUREG-0737,Item II.F.2) Outstanding Questions.Updated Schedule for Fourth Refueling Outage Will Be Provided by 840601 + (11:22:01, 14 December 2024)
- ML20082T786 + (11:22:01, 14 December 2024)
- ML20082T778 + (11:22:02, 14 December 2024)
- 05000370/LER-1983-076-03, /03L-0:on 831031,while in Mode 5,one of Four Upper Head Injection Level Switch Setpoints Found Out of Tolerance.Caused by Design Deficiency.Calibr Frequency Increased Until Switches Replaced + (11:22:03, 14 December 2024)
- HL-1828, Monthly Operating Repts for Aug 1991 for Plant Hatch,Units 1 & 2 + (11:22:04, 14 December 2024)
- ML20082T773 + (11:22:05, 14 December 2024)
- ML20082T772 + (11:22:06, 14 December 2024)
- 05000369/LER-1983-108-03, /03L-0:on 831103,bad Universal Logic Card Found Which Would Not Provide Feedwater Isolation After Reactor Trip.Caused by Component Failure.Card Replaced.Train a Tested & Declared Operable + (11:22:08, 14 December 2024)
- ML20082T767 + (11:22:09, 14 December 2024)
- 05000389/LER-1983-071-03, /03L-0:on 831108,two Pinhole Leaks Noted on Charging Pump 2B Discharge Valve.Cause Unknown.Valve & Section of Line Replaced + (11:22:10, 14 December 2024)
- NRC-91-2485, Monthly Operating Rept for Aug 1991 for Callaway Plant,Unit 1 + (11:22:11, 14 December 2024)
- ML20082T753 + (11:22:12, 14 December 2024)