- RBG-41459, Radiological Environ Operating Rept River Bend Station for Operating Period Jan-Dec 1994 + (11:12:41, 14 December 2024)
- ML20083A947 + (11:12:42, 14 December 2024)
- ML20083A943 + (11:12:42, 14 December 2024)
- 05000364/LER-1983-060-03, /03L-0:on 831116,during Performance of Containment Airlocks Interlock Test FNP-2-STP-607.0,auxiliary Access Airlock Declared Inoperable Due to Failure of Door Interlock.Caused by Misalignment of Linkage + (11:12:44, 14 December 2024)
- ML20083A933 + (11:12:45, 14 December 2024)
- 05000387/LER-1983-149-03, /03L-0:on 831102,emergency Svc Water Pump B Failed to Start Manually,Resulting in Unit Entering Limiting Conditions for Operation.Caused by Failure of Breaker for Essential Svc Water Pump B to Close + (11:12:46, 14 December 2024)
- 05000336/LER-1991-008, :on 910525,reactor Tripped Due to Low Steam Generator Pressure.Caused by Ineffective Coordination Between Reactor & Turbine Shutdown.Cr Operating Shift Completed Applicable Portions of EOP-2525 + (11:12:48, 14 December 2024)
- ML20083A915 + (11:12:49, 14 December 2024)
- ML20083A912 + (11:12:50, 14 December 2024)
- ML20083A909 + (11:12:50, 14 December 2024)
- 05000364/LER-1983-059-03, /03L-0:on 831116,core Axial Flux Difference Determined to Be Outside Target Band by 0.5%.Caused by Personnel Error.Dilution Secured + (11:12:52, 14 December 2024)
- ML20083A888 + (11:12:53, 14 December 2024)
- 05000261/LER-1983-028-01, /01T-0:on 831123,during Review of Steam Generator Eddy Current Insp Data Tapes,Two Tubes Appeared to Need Plugging.All Tubes W/Eddy Current Greater than 47% Mechanically Plugged + (11:12:54, 14 December 2024)
- ML20083A861 + (11:12:56, 14 December 2024)
- 05000327/LER-1983-169-03, /03L-0:on 831117,steam Generator Blowdown Flow Rate Monitor 1-FE-15-25 Declared Inoperable Due to Loss of Recorder.Caused by Ink Pen Not in Contact W/Paper & Out of Ink.Preventive Maint Program Initiated + (11:12:57, 14 December 2024)
- ML20083A849 + (11:12:58, 14 December 2024)
- ML20083A850 + (11:12:58, 14 December 2024)
- ML20083A838 + (11:12:59, 14 December 2024)
- ML20083A829 + (11:13:00, 14 December 2024)
- ML20083A818 + (11:13:00, 14 December 2024)
- ML20083A815 + (11:13:01, 14 December 2024)
- 05000321/LER-1991-015-01, :on 910823,loss of Power to B Reactor Protection Sys (RPS) Bus Due to B RPS motor-generator Set Tripped.Caused by Component Failure & MSL RM Design Inadequacy.Defective Light Bulb Replaced + (11:13:02, 14 December 2024)
- ML20083A812 + (11:13:08, 14 December 2024)
- ML20083A794 + (11:13:15, 14 December 2024)
- ML20083A792 + (11:13:16, 14 December 2024)
- ML20083A778 + (11:13:25, 14 December 2024)
- 3F1183-23, Responds to IE Bulletin 83-04, Failure of Undervoltage Trip Function of Reactor Trip Breakers (GE AK-2). Review of Spare Trip Breaker Installed W/O Required Qualification Documentation Completed + (11:13:26, 14 December 2024)
- ML20083A777 + (11:13:26, 14 December 2024)
- ML20083A765 + (11:13:27, 14 December 2024)
- ML20083A759 + (11:13:28, 14 December 2024)
- ML20083A761 + (11:13:28, 14 December 2024)
- ST-HL-AE-5069, Responds to NRC Re Violations Noted in Insp of Licenses NPF-76 & NPF-80.Corrective Actions:Addl Drawings Affected by Plant Change Form Have Been Revised & All Currently Installed Temporary Mods Have Been Audited + (11:13:29, 14 December 2024)
- ML20083A753 + (11:13:29, 14 December 2024)
- ML20083A747 + (11:13:30, 14 December 2024)
- ML20083A751 + (11:13:30, 14 December 2024)
- NRC-95-0043, Forwards Rev 7 to Fermi 2 Updated FSAR & Fermi 2 Safety Evaluation Summary Rept + (11:13:31, 14 December 2024)
- ML20083A724 + (11:13:32, 14 December 2024)
- ML20083A721 + (11:13:32, 14 December 2024)
- ML20083A715 + (11:13:33, 14 December 2024)
- ML20083A710 + (11:13:33, 14 December 2024)
- ML20083A705 + (11:13:34, 14 December 2024)
- ML20083A684 + (11:13:35, 14 December 2024)
- ML20083A691 + (11:13:35, 14 December 2024)
- ML20083A674 + (11:13:44, 14 December 2024)
- PY-CEI-NRR-1944, Suppl Application for Amend to License NPF-58,App a Tss. Suppl Addresses Minor Discrepancies & Items Needing Clarification + (11:13:45, 14 December 2024)
- ML20083A664 + (11:13:46, 14 December 2024)
- ML20083A662 + (11:13:46, 14 December 2024)
- ML20083A660 + (11:13:47, 14 December 2024)
- ML20083A661 + (11:13:47, 14 December 2024)
- BSEP-95-0219, Plant Mod Wire Lift Results in Isolation of Sys Not Properly Separated from Mod Work + (11:13:48, 14 December 2024)
- ML20083A654 + (11:13:51, 14 December 2024)
- ML20083A653 + (11:13:52, 14 December 2024)