- ML20087Q074 + (18:47:43, 13 December 2024)
- ML20087Q067 + (18:47:44, 13 December 2024)
- ML20087Q071 + (18:47:44, 13 December 2024)
- AECM-84-0201, Special Rept 84-016/0:on 840301,fire Barriers in U712 Control Room Floor Module LA57-L072 Opened for Planned Maint Activities.Fire Watch Established Until Barriers Restored on 840329 + (18:47:45, 13 December 2024)
- ML20087Q064 + (18:47:46, 13 December 2024)
- 05000259/LER-1984-018-01, :on 840320,following RCIC Steam Leak Repair, Inboard MSIV Would Not Open.Caused by High Pressure Differential Across Valve Disc.Valve Opened When Pressure Equalized + (18:47:48, 13 December 2024)
- ML20087Q060 + (18:47:49, 13 December 2024)
- ML20087Q059 + (18:47:50, 13 December 2024)
- ML20087Q056 + (18:47:51, 13 December 2024)
- ML20087Q057 + (18:47:51, 13 December 2024)
- ML20087Q055 + (18:47:52, 13 December 2024)
- 05000254/LER-1984-003-06, :on 840306,three Full Reactor Scrams Received Due to Erratic Reactor Water Level Indications.Caused by Unusual Temp & Pressure Conditions Resulting from Procedure Allowing Water Cooling W/Reactor Not Vented + (18:47:54, 13 December 2024)
- 0CAN048405, Annual Financial Rept 1983 + (18:47:55, 13 December 2024)
- ML20087Q048 + (18:47:56, 13 December 2024)
- ML20087Q047 + (18:47:57, 13 December 2024)
- ML20087Q044 + (18:47:58, 13 December 2024)
- 05000277/LER-1983-025-03, /03L-0:on 831229,outboard MSIV AO-2-2-86B Fast Closure Time Was 5.5 S.Caused by Insufficient Flow Through Fast Closure Needle Valve on Oil Dashpot.Valve Readjusted & Retested + (18:47:59, 13 December 2024)
- 05000285/LER-1984-004, :on 840303,reactor Coolant Radioactivity Exceeded Tech Spec Limits.Caused by Iodine Spike Following Reactor Power Change.No Corrective Actions Planned + (18:48:02, 13 December 2024)
- 05000251/LER-1984-004-02, :on 840307,while Purging,Spurious Signal to Process Radiation Monitor R-11 Actuated Containment & Control Room Ventilation Sys Logic,Closing Purge Valve & Placing Ventilation Sys in Recirculation Mode + (18:48:04, 13 December 2024)
- 05000335/LER-1984-001-03, :on 840307,design Problem Re Undervoltage Relaying of 480-volt Buses Discovered on Diesel Generator Loading Sequence Under Certain Accident Conditions.Plant Change/Mod Implemented + (18:48:06, 13 December 2024)
- ML20087Q036 + (18:48:07, 13 December 2024)
- ML20087Q032 + (18:48:07, 13 December 2024)
- ML20087Q030 + (18:48:11, 13 December 2024)
- ML20087Q028 + (18:48:13, 13 December 2024)
- 05000269/LER-1984-001-04, :on 840301,boron Concentrations of Two Independent Core Flood Tank 1A Samples Less than Tech Spec Requirements.Caused by Lack of Adequate Mgt Control Over Known Problem.Procedures Revised + (18:48:15, 13 December 2024)
- ML20087Q025 + (18:48:16, 13 December 2024)
- ML20087Q022 + (18:48:17, 13 December 2024)
- RBG-17-486, Interim Deficiency Rept DR-140 Re Engine Mounted Fuel Oil Line in Standby Diesel Generator Supplied by Transamerica Delaval,Inc.Investigation Incomplete.Next Rept Will Be Submitted by 840523 + (18:48:17, 13 December 2024)
- ML20087Q012 + (18:48:18, 13 December 2024)
- ML20087Q011 + (18:48:19, 13 December 2024)
- RBG-17-448, Forwards Supplemental Response to Items Identified by Structural & Geotechnical Engineering Branch.Response in Encl 1 Will Be Included in Future FSAR Amend + (18:48:19, 13 December 2024)
- ML20087Q009 + (18:48:20, 13 December 2024)
- ML20087Q007 + (18:48:21, 13 December 2024)
- ML20087Q004 + (18:48:21, 13 December 2024)
- PY-CEI-NRR-0104, Confirms 840402 Telcon Re Schedule for Onsite Audits by Seismic Qualficiation Review Team & Pump & Valve Operability Review Team.Audits Requested During Wk of 840813 + (18:48:22, 13 December 2024)
- ML20087Q002 + (18:48:23, 13 December 2024)
- ML20087Q001 + (18:48:23, 13 December 2024)
- 05000387/LER-1984-012, :on 840229,discovered Functional Testing of Common Offgas Sys Hydrogen Analyzer Channel B Not Performed on 840225 as Required.Caused by Due Date Omitted from Surveillance Authorization + (18:48:25, 13 December 2024)
- ML20087P999 + (18:48:28, 13 December 2024)
- ML20087P991 + (18:48:30, 13 December 2024)
- ML20087P993 + (18:48:30, 13 December 2024)
- ML20087P990 + (18:48:31, 13 December 2024)
- ML20087P987 + (18:48:32, 13 December 2024)
- ML20087P985 + (18:48:33, 13 December 2024)
- ML20087P984 + (18:48:34, 13 December 2024)
- ML20087P982 + (18:48:35, 13 December 2024)
- ML20087P981 + (18:48:35, 13 December 2024)
- ML20087P977 + (18:48:36, 13 December 2024)
- ML20087P976 + (18:48:37, 13 December 2024)
- AECM-84-0209, Final Deficiency Rept for Unit 1 & Interim Rept for Unit 2 Re Calculated Max Temp for Main Feedwater Movement Guides Exceeding Original Design Limitation for Concrete within Auxiliary Bldg G-line Wall.Also Reportable Per 10CFR21 + (18:48:38, 13 December 2024)
- ML20087P973 + (18:48:39, 13 December 2024)