- ML20091F335 + (17:30:25, 13 December 2024)
- 05000339/LER-1991-011-02, :on 911103,plant Shutdown Required by Technical Specifications Due to RHR Valve Packing Failure.Caused by Failure of Packing RHR Sys Inlet Isolation Motor Operated Valve.Valve Packing Repaired + (17:30:27, 13 December 2024)
- ML20091F312 + (17:30:30, 13 December 2024)
- 05000333/LER-1991-021, :on 910904,exhaust Ventilation Fan for One of Two safety-related Pump Rooms Tripped on Thermal Overload. Caused by Restricted Ventilation Air Supply to Pump Rooms. Fire Watch Posted & Damper Procedure Revised + (17:30:32, 13 December 2024)
- ML20091F302 + (17:30:34, 13 December 2024)
- 05000266/LER-1991-014, :on 911103,20% Runback of Turbine Generator Occurred.Caused by Output Transient on power-range Nuclear Instrumentation Channel N44.On 911105,voltage Spike Occurred.Power Supply Replaced + (17:30:36, 13 December 2024)
- ML20091F296 + (17:30:43, 13 December 2024)
- ML20091F293 + (17:30:46, 13 December 2024)
- ML20091F289 + (17:30:47, 13 December 2024)
- 05000413/LER-1991-028, :on 911024,Tech Spec Violation Occurred Due to Exceeding Liquid Waste Release Limits as Result of Inappropriate Actions.Chemistry Specialist Counseled.W/ 911120 1tr + (17:30:56, 13 December 2024)
- 05000458/LER-1991-019, :on 911026,discovered That Surveillance Test Procedure for Radwaste Bldg Ventilation Exhaust Duct Noble Gas Activity Monitor Not Completed in TS Time Frame.Caused by Personnel Error.Personnel Briefed + (17:30:58, 13 December 2024)
- 05000445/LER-1991-026, :on 911030,discovered That Pressurizer Safety Valves Inoperable.On 911028,valves Found to Have Setpoints 1% to 4% Less than TS Setpoint Tolerance.Caused by Inadequate Methodology.Valves Reset + (17:31:01, 13 December 2024)
- NLS9100767, Discusses Loading of Addl Lattice Fuel Bundle Type (GE8x8NB) Into Core for Cycle 15 Operation.Addl Bundle Description Encl Withheld (Ref 10CFR2.790) + (17:31:02, 13 December 2024)
- ML20091F273 + (17:31:04, 13 December 2024)
- ML20091F269 + (17:31:05, 13 December 2024)
- ML20091F262 + (17:31:07, 13 December 2024)
- ML20091F253 + (17:31:08, 13 December 2024)
- ML20091F250 + (17:31:09, 13 December 2024)
- ML20091F244 + (17:31:11, 13 December 2024)
- ML20091F237 + (17:31:14, 13 December 2024)
- ML20091F230 + (17:31:16, 13 December 2024)
- ML20091F225 + (17:31:18, 13 December 2024)
- ML20091F219 + (17:31:19, 13 December 2024)
- ML20091F217 + (17:31:20, 13 December 2024)
- ML20091F216 + (17:31:21, 13 December 2024)
- RA-20-0045, RA-20-0045, Request for Alternative to Examination Category B-N-1 (VT-3) Visual Examination of Accessible Areas of the Reactor Vessel Interior + (17:31:22, 13 December 2024)
- ML20091F209 + (17:31:26, 13 December 2024)
- ML20091F204 + (17:31:28, 13 December 2024)
- ML20091F205 + (17:31:28, 13 December 2024)
- ML20091F203 + (17:31:29, 13 December 2024)
- ELV-03150, Application for Amends to Licenses NPF-68 & NPF-81,revising TS 4.5.2.d & 4.4.9.3.2 to Allow Removal of RHR Sys Suction Valve Autoclosure & Forwards WCAP-12927, RHR Sys Autoclosure Interlock Removal Rept for Vogtle Electric.. + (17:31:31, 13 December 2024)
- ML20091F198 + (17:31:31, 13 December 2024)
- ML20091F190 + (17:31:36, 13 December 2024)
- ML20091F189 + (17:31:37, 13 December 2024)
- ML20091F182 + (17:31:38, 13 December 2024)
- ML20091F178 + (17:31:39, 13 December 2024)
- ML20091F164 + (17:31:40, 13 December 2024)
- 05000321/LER-1992-007, :on 920316,HPCI Sys Isolation Annunicator Alarmed in Main Control Room,Resulting in Automatic Closure of Valve 1E41-F002.Caused by Technician Bumping Actuating Arm of Relay.Individual Counseled & Trained + (17:31:42, 13 December 2024)
- ML20091F150 + (17:31:43, 13 December 2024)
- 05000318/LER-1992-002, :on 920305,both Independent Containment Spray Sys Declared Inoperable.Caused by Failed Air Filter in Air Start Sys & Loss of EDG 21.Adequate Flow Restored & New Style Air Filters Installed + (17:31:45, 13 December 2024)
- 05000277/LER-1992-003-01, :on 920313,determined That RHR Pumps 2B & 2D Could Have Potentially Been Placed in Inoperable Condition Had Low Energy Pipe Failed in RHR Rooms.Cause Not Determined.Discharge Check Valves Installed + (17:31:47, 13 December 2024)
- 05000277/LER-1992-002-02, :on 920311,EDG E-3 Started in 13 Instead of 10 Requirement in Updated Fsar.Caused by Improperly Primed Oil Filter After Filter Replacement.Info Tags Hung on All EDG Fuel Oil Filters & Training Held + (17:31:49, 13 December 2024)
- ML20091F139 + (17:31:50, 13 December 2024)
- ML20091F128 + (17:31:56, 13 December 2024)
- IR 05000329/1983008 + (17:32:14, 13 December 2024)
- ML20091F096 + (17:32:17, 13 December 2024)
- ML20091F095 + (17:32:18, 13 December 2024)
- ML20091F092 + (17:32:32, 13 December 2024)
- ML20091F043 + (17:32:34, 13 December 2024)
- ML20091F052 + (17:32:34, 13 December 2024)
- ML20091F040 + (17:32:35, 13 December 2024)