- 05000322/LER-1985-042, :on 850912,low Level Reactor Trip Occurred During Operational Condition 2.Caused by Operator Opening & Closing Test Valve,Producing Pressure Oscillation in Narrow Range Variable Leg A.Operator Counseled + (13:07:12, 12 December 2024)
- ML20133H452 + (13:07:14, 12 December 2024)
- 05000454/LER-1985-089, :on 850913,both Trains of Control Room Ventilation Inoperable.Caused by Workers Misreading HVAC Ductwork Drawings.Project Const Dept Will Review HVAC Drawing Conventions W/Personnel Responsible + (13:07:16, 12 December 2024)
- 05000361/LER-1985-048, :on 850915,w/unit in Mode 3,containment Purge Initiated,Requiring Collection of Iodine & Particulate Sample.Sample Collected Late Due to Failure of Chemistry Technician to Follow Direction + (13:07:17, 12 December 2024)
- ML20133H448 + (13:07:19, 12 December 2024)
- 05000322/LER-1985-039, :on 850909 & 18,while Performing Surveillance Procedure on Reactor Bldg Standby Ventilation Sys Filter Trains,Control Room Air Conditioning Initiations Occurred Due to Low Differential Pressure Condition + (13:07:21, 12 December 2024)
- ML20133H445 + (13:07:22, 12 December 2024)
- ML20133H441 + (13:07:23, 12 December 2024)
- ML20133H443 + (13:07:23, 12 December 2024)
- ML20133H439 + (13:07:24, 12 December 2024)
- ML20133H436 + (13:07:25, 12 December 2024)
- ML20133H438 + (13:07:25, 12 December 2024)
- ML20133H433 + (13:07:28, 12 December 2024)
- ML20133H432 + (13:07:29, 12 December 2024)
- W3P85-1442, Final Potentially Reportable Deficiency Rept 180 Re Failure to Maintain Adequate Control of Vendor Manuals.Initially Reported on 840918.Preventive Maint Program Implemented.Item Not Reportable Per 10CFR50.55(e) + (13:07:36, 12 December 2024)
- ML20133H425 + (13:07:38, 12 December 2024)
- IR 05000397/1985034 + (13:07:40, 12 December 2024)
- ML20133H420 + (13:07:41, 12 December 2024)
- ML20133H421 + (13:07:41, 12 December 2024)
- ML20133H419 + (13:07:42, 12 December 2024)
- ML20133H418 + (13:07:42, 12 December 2024)
- ML20133H417 + (13:07:44, 12 December 2024)
- RBG-22303, Submits Weekly Status Rept Identifying License Conditions & Other Commitments Completed During Previous Wk & Cumulatively Since Issuance of Low Power License.Cummulative Listing & Commitments Encl + (13:07:44, 12 December 2024)
- ML20133H414 + (13:07:45, 12 December 2024)
- ML20133H415 + (13:07:45, 12 December 2024)
- ML20133H411 + (13:07:46, 12 December 2024)
- ML20133H409 + (13:07:47, 12 December 2024)
- ML20133H410 + (13:07:47, 12 December 2024)
- ML20133H408 + (13:07:48, 12 December 2024)
- IR 05000930/2010001 + (13:07:49, 12 December 2024)
- ML20133H405 + (13:07:49, 12 December 2024)
- IR 05000219/1985023 + (13:07:56, 12 December 2024)
- ML20133H401 + (13:07:57, 12 December 2024)
- ML20133H400 + (13:07:58, 12 December 2024)
- IR 05000701/2008018 + (13:07:59, 12 December 2024)
- ML20133H398 + (13:08:00, 12 December 2024)
- IR 05000730/2008002 + (13:08:02, 12 December 2024)
- ML20133H395 + (13:08:03, 12 December 2024)
- ML20133H394 + (13:08:04, 12 December 2024)
- ML20133H393 + (13:08:05, 12 December 2024)
- ML20133H388 + (13:08:06, 12 December 2024)
- ML20133H391 + (13:08:06, 12 December 2024)
- 05000278/LER-1985-011, :on 850621,discovered That Fire Watch Not Established for Fire Barriers Between MSIV Room & Torus Room,Per Tech Specs.Caused by Error in Design Drawings & Personnel Oversight.All Drawings Reviewed + (13:08:09, 12 December 2024)
- ML20133H384 + (13:08:10, 12 December 2024)
- ML20133H383 + (13:08:10, 12 December 2024)
- ML20133H382 + (13:08:11, 12 December 2024)
- ML20133H380 + (13:08:12, 12 December 2024)
- ML20133H381 + (13:08:12, 12 December 2024)
- ML20133H378 + (13:08:13, 12 December 2024)
- ML20133H375 + (13:08:14, 12 December 2024)
- ML20133H373 + (13:08:15, 12 December 2024)
- 05000220/LER-1985-015, :on 850911,personnel Informed of Three Instances of Cable Routing Discrepancies.Operators Informed. Mods Designed & Will Be Installed in Timely Manner + (13:08:16, 12 December 2024)