Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20140A892 + (22:29:48, 11 December 2024)
- ML20140A889 + (22:29:49, 11 December 2024)
- 05000482/LER-1985-086, :on 851220,discovered That Required Fire Dampers Not Installed in Ventilation Penetrations Through 3-h Fire Walls in Auxiliary Bldg.Caused by Design Oversight. Design Change to Require Fire Dampers Prepared + (22:29:50, 11 December 2024)
- 05000348/LER-1997-006-01, :on 970401,SG Tube Degradation & Tube Status Was Reported.Caused by Defects in Tube Sheet & Expansion Transition Degradation.Sg Tubes Have Been Plugged or Repaired + (22:29:52, 11 December 2024)
- PNO-III-97-053, on 970602,Unit 1 Experienced Automatic Reactor Trip from 100% Power,Due to Electrical Failure in One of Three Control Rod Control Cabinets.All Safety Sys Functioned as Designed & Reactor Stabilized in Hot Shutdown + (22:29:54, 11 December 2024)
- ML20140A878 + (22:29:55, 11 December 2024)
- SNRC-1222, Responds to Concerns Re Concerning Fire Protection.Control of Safety Relief Valves Not Maintained by Disabling ECCS in Event of Fire.Ie Info Notice 85-009 Re Lack of Fuses in Alternate Shutdown Sys Not Applicable + (22:29:55, 11 December 2024)
- ML20140A874 + (22:29:56, 11 December 2024)
- ML20140A868 + (22:29:59, 11 December 2024)
- ML20140A862 + (22:30:00, 11 December 2024)
- ML20140A860 + (22:30:01, 11 December 2024)
- RBG-22-740, Responds to Violations Noted in Insp Rept 50-458/85-71. Corrective Actions:All Procedures Identified as Having Calibr Limits Outside Tech Spec Requirements Being Revised to Incorporate Correct Requirements + (22:30:02, 11 December 2024)
- 05000271/LER-1997-002, :on 970221,inadequate Design Allowed Util to Be Vulnerable to Flooding During Max Postulated Flood Conditions.Caused by Failure to Identify Design Vulnerability.Event Rept,Initiated + (22:30:04, 11 December 2024)
- U-600404, Responds to SER Outstanding Issue 7ii & Unresolved Items Identified by Sqrt During 850827-30 Visit.Responses to Sqrt Open Item NSSS 10.1 & Generic Item 8 Also Encl.Encl Withheld + (22:30:05, 11 December 2024)
- ML20140A847 + (22:30:08, 11 December 2024)
- ST-HL-AE-1579, Requests Draft SER Items 44A,B & C Re Surveillance Program for Insp of post-irradiated Fuel Assemblies Be Considered Closed,Based on Encl Response + (22:30:08, 11 December 2024)
- ML20140A840 + (22:30:10, 11 December 2024)
- ML20140A841 + (22:30:10, 11 December 2024)
- 05000259/LER-1985-052, :on 850924,fuse Labelling Discrepancies Found in Variations of Fuse Amp Rating,Fuse Type & Class & Fuse Block Type.Caused by Lack of Comprehensive Fuse Control Program.Fuse Control Procedure Established + (22:30:12, 11 December 2024)
- ML20140A836 + (22:30:13, 11 December 2024)
- IR 05000458/1985071 + (22:30:17, 11 December 2024)
- ML20140A835 + (22:30:17, 11 December 2024)
- ML20140A832 + (22:30:18, 11 December 2024)
- ML20140A830 + (22:30:19, 11 December 2024)
- ML20140A829 + (22:30:19, 11 December 2024)
- ML20140A827 + (22:30:20, 11 December 2024)
- ML20140A821 + (22:30:21, 11 December 2024)
- ML20140A818 + (22:30:22, 11 December 2024)
- ML20140A816 + (22:30:23, 11 December 2024)
- ML20140A811 + (22:30:24, 11 December 2024)
- ML20140A810 + (22:30:24, 11 December 2024)
- ML20140A801 + (22:30:32, 11 December 2024)
- ML20140A794 + (22:30:33, 11 December 2024)
- ML20140A790 + (22:30:34, 11 December 2024)
- ML20140A784 + (22:30:35, 11 December 2024)
- 05000443/LER-1997-005, :on 970314,misposition of Main Steam Line Radiation Monitors Was Discovered.Caused by Human & Misjudgement Errors.Design Change Was Implemented to Relocate MSLRMs Approx 24 Inches Upstream + (22:30:37, 11 December 2024)
- ML20140A781 + (22:30:38, 11 December 2024)
- ML20140A777 + (22:30:39, 11 December 2024)
- ML20140A775 + (22:30:40, 11 December 2024)
- ML20140A774 + (22:30:41, 11 December 2024)
- 05000454/LER-1986-008, :on 860217,turbine Generator & Reactor Trips Occurred Due to Phase Differential Current Sensed by Main Transformer.Caused by Ice Buildup on Transmission Line Tower During Ice Storm.Transformer Replaced + (22:30:42, 11 December 2024)
- ML20140A770 + (22:30:43, 11 December 2024)
- ML20140A766 + (22:30:44, 11 December 2024)
- SNRC-1223, Forwards License Change Application 3 for Amend to License NPF-36,changing Tech Specs to Eliminate Performing Sampling Analysis If No Waste Batch Released During Month & Correcting Error in Basis for Milk Control Sample.Fee Paid + (22:30:45, 11 December 2024)
- ML20140A762 + (22:30:46, 11 December 2024)
- ML20140A759 + (22:30:47, 11 December 2024)
- ML20140A758 + (22:30:48, 11 December 2024)
- ML20140A751 + (22:30:49, 11 December 2024)
- ML20140A747 + (22:30:50, 11 December 2024)
- LIC-97-0070, Forwards Revs to USAR for Fort Calhoun Station. Attachment B Is Provided to Describe Revs to USAR Other than Revs Resulting from 10CFR50.59 Changes + (22:30:51, 11 December 2024)
- ML20140A738 + (22:30:55, 11 December 2024)